Laserfiche WebLink
Toilet Layout <br />SCALE: 1/2" =1'-0' <br />RESTROOM <br />UNISEX RESTROOM SIGN <br />PROVIDE (1) SIGN COMPLYING WITH ADA LOCAL CODE. <br />SIGN TO HAVE RAISED AND BRAILLE CHARACTERS AND <br />PICTORIAL SYMBOL OF ACCESSIBILITY. MOUNT CENTER <br />OF SIGN 5'-0" AFF ON THE WALL ON THE STRIKE SIDE OF <br />THE DOOR. SIGN TO BE GRAY WITH WHITE CHARACTERS. <br />6Accessible Signage <br />SCALE: 3" =1'-0" <br />Door Schedule <br />DOOR <br />FRAME <br />HARD <br />WARE <br />TYPE <br />MATERIAL <br />SIZE <br />MATERIAL <br />DETAILS <br />SET <br />A <br />ALUM <br />3'-0" X 7'" <br />ALUM <br />N/A <br />N/A <br />X 1 3l4 <br />B <br />HM <br />T-0" X T-0" <br />HM <br />N/A <br />N/A <br />X 1 3/4" <br />C <br />WOOD <br />3'-0" X6'-8' <br />WOOD <br />H1, J1, S1 <br />1 <br />X 1 3/4" <br />NOTES: <br />TYPES A & B ARE EXISTING TO REMAIN AS IS. <br />TYPE C IS A NEW HOLLOW CORE PREHUNG DOOR W/ REINFORCED <br />PANEL TO ACCEPT CLOSER. THE INTERIOR SHALL BE PAINTED TO <br />MATCH THE RESTROOM WALLS. EXTERIOR SHALL BE PAINT READY. <br />Hardware Notes <br />1. ADJUST ALL CLOSERS TO A 5 LB MAX OPENING FORCE. <br />2. ALL LOCK & PASSAGE SETS TO BE SCHLAGE GRADE OR BETTER. <br />LOCKS NEED TO BE REKEYABLE. <br />3. ALL DOORS & HARDWARE TO COMPLY WITH NFPA 101-5-2.1.5. <br />4. ALL DOORS & HARDWARE TO COMPLY WITH THE FLORIDA <br />ACCESSIBILITY CODE AND THE ADA FEDERAL REGULATION <br />CODES, UTILIZING A LEVER LATCH OR LOCKSET. <br />5. FINAL CORE PROCESS FOR LOCKSETS & KEYING SHALL BE: <br />THE SUBCONTRACTORS WILL INSTALLALL DOORS, FRAMES, <br />HARDWARE & LOCKSETS. <br />Hardware Schedule <br />HARDWARE SET # 1: (RESTROOM DOOR) <br />(3) - HAGER 4-1/2" X 4-1/2" BUTT FULL MORTISE <br />HINGES NO. BB1191 (NRP). STAINLESS <br />STEEL HINGES W/ STAINLESS STEEL PINS <br />(1) - LOCKSET SCHLAGE AL40S "PRIVACY LOCK' <br />FINISH 626 (US 26D) SATIN CHROME <br />(1) - CLOSER - LCN NO.4040. STANDARD POWDER <br />COAT ALUMINUM FINISH. STANDARD PLASTIC <br />COVER. MOUNTED ON INSIDE OF ROOM <br />(1) - WALL STOP <br />(3) - SILENCERS <br />\N <br />DIMENSIONS ARE FROM INSIDE FACE OF FINISH <br />Interior Elevation <br />SCALE: 1/2" = V-0" <br />DIMENSIONS ARE FROM INSIDE FACE OF FINISH <br />FLUSH CONTROL HANDLES TO BE <br />MOUNTED ON SIDE FURTHEST <br />FROM WALL TO COMPLY WITH <br />FBC 11-4.16.5 <br />5 <br />2 1 <br />7 <br />4 A <br />o � � <br />CV <br />-t <br />1'-6" 1'-3' <br />MIN MIN <br />3 Interior Elevation <br />SCALE: 1/2" =1'-0" <br />KEY <br />DESCRIPTION <br />BOBRICK MODEL <br />BRADLEY MODEL <br />ASI MODEL <br />REMARKS <br />1O <br />36" GRAB BAR <br />6806 <br />8120-001360 <br />3800-36 <br />STAINLESS STEEL, SATIN FINISH <br />1 1/4" -1 1/2" DIAMETER, PROVIDE <br />2O <br />42" GRAB BAR <br />6806 <br />8120-001420 <br />3800-42 <br />1 1/4" SPACE BETWEEN BAR & WALL <br />3O <br />MIRROR UNIT <br />B-294 <br />782 <br />0600TA <br />16" X 30" TILT MIRROR W/ STAINLESS STEEL FIRM. <br />4O <br />TOILET TISSUE DISPENSER <br />B-2888 <br />5402 <br />0030 <br />STAINLESS STEEL, MULTI ROLL -SURFACE MOUNTED <br />O <br />PAPER TOWEL DISPENSER <br />B-262 <br />250-150000 <br />0210 <br />STAINLESS STEEL SURFACE MOUNTED <br />6O <br />SOAP DISPENSER <br />STAINLESS STEEL SURFACE MOUNTED <br />O7 <br />WATER CLOSET <br />RE: ELEVATIONS ABOVE FOR FIXTURE MOUNTING HEIGHTS <br />88 <br />LAVATORY <br />RE: PLUMBING DRAWINGS FOR FIXTURE TYPE <br />9O <br />HI -LOW DRINKING FOUNTAIN <br />7 Toilet Accessory Schedule <br />SCALE: NTS <br />HEAD DETAIL - H1 <br />1 2" <br />JAMB DETAIL - A <br />SILL DETAIL - S1 <br />9 Door Details <br />SCALE. 3"1 0 <br />RE: WALL TYPES FOR <br />FRAMING, SHEATHING, & <br />INSULATION INFORMATION <br />CONT. 2X WOOD BLOCKING <br />AT ENTIRE PERIMETER OF <br />ROUGH OPENING <br />SOLID WOOD DOOR <br />FRAME, PAINT FINISH <br />RE: DOOR SCHEDULE <br />FLUSH HOLLOW CORE <br />WOOD DOOR <br />RE: DOOR SCHEDULE <br />RE: WALL TYPES FOR <br />FRAMING, SHEATHING, & <br />INSULATION INFORMATION <br />CONT. 2X WOOD BLOCKING <br />AT ENTIRE PERIMETER OF <br />ROUGH OPENING <br />FLUSH HOLLOW CORE <br />WOOD DOOR <br />RE: DOOR SCHEDULE <br />SOLID WOOD DOOR <br />FRAME, PAINT FINISH <br />RE: DOOR SCHEDULE <br />CAST IN PLACE CONCRETE FLOOR SLAB ON GRADE <br />DIMENSIONS ARE FROM INSIDE FACE OF FINISH <br />rRvv wr= rwn %.v1V1rL1r%N 1 nvOUuv iviv vrc uw <br />GUARD TO PROTECT FROM CONTACT. REFER <br />TO FIXTURE SCHEDULE ON PLUMBING DRAWINGS <br />4 Interior Elevation <br />SCALE: 1/2" = V-0" <br />5 Drinking Fountains <br />SCALE: 1/2" =1'-0" <br />GENERAL NOTES: <br />1. ALLACCESSORIES ARE TO BE MOUNTED IN ACCORDANCE WITH THE ACCESSIBILITY CRITERIA OF AMERICAN <br />WITH DISABILITIES ACTAS WELL AS WITH ANYAPPLICABLE STATE AND LOCAL ACCESSIBILITY CODES. <br />2. UNLESS OTHERWISE NOTED, THE FINISH SCHEDULE FOR ALL RESTROOMS SHALL BE AS FOLLOWS: <br />FLOORING - VCT; WALL BASE - 6" VINYL; WALLS - ENAMEL PAINT OVER WATER PROOF TYPE GYPSUM <br />BOARD; CEILINGS -ACOUSTICAL TILE. <br />3. INSTALL SUPPORT BLOCKING IN WALLS WHERE NECESSARY FOR TOILET ACCESSORIES, INCLUDING GRAB <br />BARS. REFER TO MANUFACTURING INSTALLATION INSTRUCTIONS. <br />4. PROVIDE INSULATION ON DRAINS AND HOT WATER LINES AT HANDICAP LAVATORIES. <br />5. UNLESS OTHERWISE NOTED, ALL RESTROOM CEILINGS TO BE AT 10'-0" ABOVE THE FINISHED FLOOR. <br />6. REFER TO Al01 FOR ALL WALL TYPE INFORMATION. <br />General Notes <br />SCALE: NTS <br />A. CONCRETE WORK SHALL CONFORM TO ACI-05 SPECIFICATIONS, CODES AND STANDARDS. <br />B. CONCRETE SHALL BE PORTLAND CEMENT PER ASTM C150. CONCRETE SHALL BE PROPORTIONED <br />FOR MAXIMUM ALLOWABLE UNIT SHRINKAGE OF 0.03%AND SHALL BE 25% MAXIMUM FLYASH BY <br />WEIGHT. <br />C. CONCRETE SHALL BE 4" THICK, 3,000 PSI 28-DAY COMPRESSIVE STRENGTH, NORMAL WEIGHT, <br />MAXIMUM AGGREGATE SIZE OF 1", 0.55 MAX. W/C, 4"-5" SLUMP. <br />D. CONCRETE SHALL HAVE 6 X 6X2.1 X 2.1 WWF AND BE PLACED OVER A 6 MIL VAPOR BARRIER ON <br />TERMITE TREATED COMPACTED SOIL. <br />E. CONCRETE SHALL HAVE MINUNUM 1 1/2" COVER OVER REBAR SIZED #3 - #5. <br />F. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. <br />G. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. WIRE FABRIC SHALL BE CONTINUOUS, <br />LAPPED ONE CROSS WIRE SPACING PLUS 2" MINIMUM. <br />H. CONTRACTOR SHALL EMPLOYA QUALIFIED TESTING LABORATORY TO PREPARE ONE SET OF FOUR <br />TEST CYLINDERS PER DAY OR ONE SET FOR EACH 50 CUBIC YARDS POURED, MAXIMUM. <br />LABORATORY REPORT SHALL BE FURNISHED TO THE STRUCTURAL ENGINEER SHOWING STRENGTH <br />OF CONCRETE AT 7 (1 CYLINDER) AND 28 (2 CYLINDERS) DAYS. FINAL CYLINDER SHALL BE HELD IN <br />RESERVE. <br />I. SAW CUT CONTROL JOINTS SHALL BE LOCATED @ 16 O.C. MAXIMUM, U.O.N. WITH LENGTH TO WIDTH <br />RATIO NOT TO EXCEED 2:1. NEW CONTROL JOINTS SHALL BE ALIGNED WITH EXISTING. <br />J. ALL EPDXYANCHORS USED AT REINFORCED CONCRETE SHALL BE HILTI HVA, U.O.N. <br />K. POWDER ACTUATED FASTENERS (PAFS) NOT PERMITTED AT CONCRETE. <br />L. ANY FILL REQUIRED TO BACKFILL EXCAVATED AREA OR ACHIEVE FINISHED GRADE IN STRUCTURAL <br />AREAS SHALL BE AS INDICATED BY GEOTECHNICAL REPORT PROVIDED BY OWNER. THE FILL SHALL <br />BE PLACED IN LEVEL LIFTS NOT TO EXCEED 12 INCHES LOOSE THICKNESS AND COMPACTED TO A <br />MINIMUM OF 95% OF THE SOIL'S MODIFIED PROCTOR MAXIMUM DRY DENSITYAS DETERMINED BY <br />ASTM SPECIFICATION D-1557. <br />M. AN IN -PLACE DENSITY TESTS SHALL BE PERFORMED BYAN EXPERIENCED ENGINEERING TECHNICIAN <br />IN THE AREA OF THE SLAB POUR. <br />N. REMOVE FREE WATER FROM EXCAVATIONS BEFORE PLACING CONCRETE. <br />0. CAUTION SHOULD BE USED WHEN OPERATING VIBRATORY COMPACTING EQUIPMENT NEAR THE <br />EXISTING STRUCTURE TO AVOID THE RISK OF DAMAGE TO THE STRUCTURE. <br />P. THE CONTRACTOR SHALL SUBMIT COPIES OF THE CONCRETE MIX DESIGN AS WELL AS COPIES OF <br />ANY TEST REPORTS. <br />Q. SUBMITTALS SHALL BE APPROVED, SIGNED, AND DATED BY THE GENERAL CONTRACTOR PRIOR TO <br />SUBMITTAL TO ENGINEER AND ARCHITECT OF RECORD. <br />10 Slab Notes <br />SCALE: N / A <br />OUTSIDE <br />1 N <br />1 <br />EXISTING CMU BELOW - <br />GRADE TO REMAIN <br />EXISTING FOUNDATION <br />TO REMAIN <br />NE <br />SLJ <br />WI, <br />EXISTING CMU WALL <br />OPENING / RE-ENTRANT CORNER, <br />PROVIDE (2) #4 REBAR X 4'-0" LONG <br />EACH SIDE AT MID -HEIGHT OF <br />SLAB AS SHOWN <br />1/8' TO 16" WIDE X V DEEP GROOVE <br />W/ HIGH TRAFFIC SEALANT FILLER <br />W.W.F. <br />(1) #5 CONT.¢ ww LU LL <br />'U >z <br />to 3 #5 VERT. BARS. ONE AT <br />CENTER OF OPENING AND <br />ONE EACH 4" FROM SIDES. <br />DRILL AND EPDXY SET 6" INTO <br />EXISTING CMU BASE. <br />New Slab at Existing CMU Wall Opening <br />New Slab at Existing CMU Wall <br />CONT. EXPANSION <br />JOINT AT WALL <br />EXISTING CMU <br />WALL TO REMAIN <br />EXISTING <br />FOUNDATION TO <br />REMAIN <br />EXISTING # 3 BAR @ 24" OC. NEW SLAB <br />SLAB DRILL & EPDXY SET <br />INTO EXISTING SLAB. <br />X X=17 i X <br />4" 12' <br />Construction Joint <br />1/8 TO 3/16 WIDE X 1" DEEP SAW CUTS TO BE MADE WITHIN 24 HOURS <br />GROOVE W/ HIGH TRAFFIC OF POUR, WWF SHALL BE CONTINUOUS @ <br />SEALANT FILLER ALL C.J.S. U.O.N. ON PLANS <br />X X X X X <br />Sawcut Joint <br />11 SlabSDetails <br />SCALE: <br />System No. W-L-1001 (June 15, 2005) <br />F Ratings —1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings — 0, 1, 2, 3, and 4 Hr (See Item 3) <br />L Rating At Ambient — less than 1 CFM/sq ft L Rating At 400 F — less than 1 CFM/sq ft <br />SECTION A -A <br />1. Wall Assembly — The 1, 2, 3 or 4 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed <br />of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition <br />Designs in the UL Fire Resistance Directory and shall include the following construction features; <br />A. Studs — Wall framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel <br />studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC with <br />nom 2 by 4 in. (51 by 102 mm) lumber end plates and cross braces. Steel studs to be min 3-5/8 in. (92 <br />mm) wide by 1-3/8 in. (35 mm) deep channels spaced max 24 in. (6 10 mm) OC. <br />B. Gypsum Board* — Nom 1/2 or 5/8 in. (13 or 16 mm) thick, 4 ft. (122 cm) wide with square or tapered <br />edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall <br />be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max <br />diam of opening is 26 in. (660 mm). <br />2. Through -Penetrant — One metallic pipe, conduit or tubing installed either concentrically or eccentrically <br />within the firestop system. The annular space between pipe, conduit or tubing and periphery of opening <br />shall be min of 0 in / (0 mm). (point contact) to max 2 in. (51 mm) Pipe, conduit or tubing to be rigidly <br />supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or <br />tubing may be used: <br />A. Steel Pipe — Nom 24 in. (6 10 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. <br />B. Iron Pipe — Nom 24 in. (6 10 mm) diam (or smaller) service weight (or heavier) cast iron soil pipe, nom <br />12 in (305 mm) diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe. <br />C. Conduit — Nom 6 in. (152 mm) diam (or smaller) steel conduit or nom 4 in (102 mm) diam (or smaller) <br />steel electrical metallic tubing <br />D. Copper Tubing —Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing <br />E. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. <br />F. Through Penetrating Product* — Flexible Metal Piping The following types of steel flexible metal gas <br />piping may be used: <br />1. Nom 2 in. (51 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may <br />or may not be removed on both sides of floor or wall assembly. OMEGA FLEX INC <br />2. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may <br />or may not be removed on both sides of floor or wall assembly. GASTITE, DIV OF TITEFLEX <br />3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may <br />or may not be removed on both sides of floor or wall assembly. WARD MFG INC <br />3. Fill, Void or Cavity Material* — Caulk or Sealant — Min 5/8. , 1-1/4,1-7/8 and 2-1/2 in. (16, 32, 48 and <br />64 mm) thickness of caulk for 1, 2, 3 and 4 hr rated assemblies, respectively, applied within annulus, flush <br />with both surfaces of wall. Min 1/4 in. (6 mm) diam bead of caulk applied to gypsum board/penetrant <br />interface at point contact location on both sides of wall. The hourly F Rating of the firestop system is <br />dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following <br />table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit <br />and the hourly fire rating of the wall assembly in which it is installed, as tabulated below: <br />Max Pipe F T <br />or Conduit Rating Rating <br />Diam In (mm) Hr Hr <br />1 (25) 1 or 2 0+, 1 or 2 <br />1 (25) 3 or 4 3 or 4 <br />4 (102) 1 or 2 0 <br />6(152) 3or4i! 0= <br />12 (305) 1 or 2 0 <br />+When copper pipe is used, T Rating is 0 h. <br />3M COMPANY — CP 25 WB+ or FB-3000 WT. <br />*Bearing the UL Classification Mark <br />UL System No. W-J-1055 <br />THROUGH PENETRATION FIRESTOP SYSTEM - NOT TO SCALE <br />DECEMBER 02, 1997 <br />F RATING - 2 HR <br />T RATING - 0 HR <br />Iv SECTION A -A <br />1. WALL ASSEMBLY MIN" THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF) <br />CONCRETE. WALL MAYALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE BLOCKS*. <br />MAX DIAM OF OPENING IS 26". <br />SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR <br />2. MANUFACTURER NAMES. <br />THROUGH PENETRANT ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED EITHER CON- <br />CENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN <br />PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN 0" (POINT CONTACT) TO MAX <br />1-3/4" PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALLASSEMBLY. <br />THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUIT OR TUBING MAY BE USED: <br />A. STEEL PIPE NOM 24" DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. <br />B. IRON PIPE NOM 24" DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br />C. CONDUIT NOM 4" DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING, NOM 6' DIAM <br />(OR SMALLER) STEEL CONDUIT OR NOM 1 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. <br />D. COPPER TUBING NOM 6" DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. <br />3. E. COPPER PIPE NOM 6" DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. <br />FILL, VOID OR CAVITY MATERIAL* - SEALANT MIN 5/8"THICKNESS OF FILL MATERIALAPPLIED <br />WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. AT THE POINT CONTACT LOCATION <br />BETWEEN THROUGH PENETRANT AND CONCRETE, A MIN 3/8' DIAM BEAD OF FILL MATERIAL <br />SHALL BE APPLIED AT THE CONCR. / THRU PENETRANT INTERFACE ON BOTH WALL SURFACES. <br />SPECIFIED TECHNOLOGIES INC - SPECSEAL 100,101,102 OR 105 SEALANT <br />*BEARING THE UL CLASSIFICATION MARKING <br />12 UL Details <br />PENETRATIONSALL EXISTING FIRE RATED WALLS MUST BE <br />SEALED SO AS TO MAINTAIN THEIR MINIMUM REQUIRED FIRE RATING <br />E <br />52 <br />Vw <br />U <br />U <br />U <br />U <br />O <br />0 <br />ram^ <br />W <br />�z00 <br />Q T_ <br />co <br />r) <br />WQ� <br />Q Ewa <br />z ' � CD <br />w I..L (M IQ- <br />J <br />0 <br />Cn <br />C <br />0 <br />E <br />E <br />0 <br />U <br />L_ <br />C_ <br />N <br />-4--0 <br />CU <br />(DE" <br />0o <br />Ln J <br />O mm <br />C� Q <br />Co ...IJt <br />♦♦ /X�5cd <br />v,mJ <br />J = <br />CU(.92 <br />�LO LOa <br />o <br />F—�N <br />a <br />�a s <br />C/) <br />.ICU <br />a) <br />0 <br />LO <br />w C) <br />J ICUI_ � V <br />w <br />w v, <br />x <br />41,11 <br />cn <br />Z <br />j o <br />w Cn <br />J � <br />m <br />Q< <br />z '¢ •_ <br />> J <br />w "- <br />w <br />w <br />- <br />a. <br />VV <br />= <br />v <br />0 <br />o <br />Uw <br />o <br />W <br />N <br />J <br />w <br />N <br />Q <br />rn <br />( <br />O <br />I <br />C) <br />CD <br />L) <br />co0 <br />Z <br />m <br />N <br />w <br />o <br />CD <br />U <br />Al 02 <br />