Laserfiche WebLink
5/8 GYP BOARD <br />SOUND BATT INSULATIO <br />WATER HEATER - SEE MEP <br />FLOOR PLAN SYMBOLS <br />° <br />DRAWINGS FOR REQUIREMENTS. <br />® <br />ROOM NUMBER <br />SECTION <br />3 5/8" 25 GA MTL — <br />STUDS @16" O.C. <br />NEW WALL FURRING OVE <br />INTERIOR OF EXISTING CMU <br />WALL SYSTEMS <br />5/8 GYP BOARD <br />SOUND BATT INSULATION <br />3 5/8" 25 GA MTL <br />STUDS @16" O.C. <br />METAL CORNER BEAD <br />LOW WALL SUPPORT <br />BRACKET 1 /8" STEEL <br />METAL STUDS @ 16" O.C. <br />0 <br />® <br />3/4" PLYWOOD SHELF <br />2"x4" P.T. WD FRAMEING <br />O <br />WINDOW TYPE* <br />DETAIL <br />HE)DOOR <br />SYMBOL- SEE DOOR SCHEDULE * <br />�•� <br />DOOR CONTACT <br />_ <br />FINISHED CLEARANCE <br />C.R. <br />CARD READER <br />MINIMUM DIMENSION MAY BE <br />METAL CORNER <br />®� <br />= <br />C.o. <br />CASED OPENING* <br />VERIFY DIMENSION COMBINED <br />BEAD <br />I ° <br />° <br />N <br />WALL TYPE - SEE WALL LEGEND & SHEET AO.5 <br />R <br />i -� <br />RADIUS OF CLEARANCE <br />_ AL _ _ <br />ALIGNMENT LINE <br />ITEM ABOVE OR FURNITURE/EQUIPMENT N.I.0 <br />CENTERLINE <br />o <br />x <br />METAL <br />CORNER BEA <br />° <br />BOTTOM CHANNEL <br />e <br />2"x4" P.T. WD BRACE <br />ITEM BELOW <br />— — <br />POB <br />POINT OF BEGINNING FOR LAYOUT <br />INTERIOR &CABINET ELEVATIONS <br />*NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES <br />® <br />WALL <br />EXISTING EXTERIOR WALL SYSTEMS <br />EXISTING STOREFRONT SYSTEMS <br />CONNECT WALL BRACKET 0 <br />SUPPORT TO FLOOR, AT <br />EACH END OF WALL, W/ (2) �7f2r� <br />1 /4" EXPANSION BOLT <br />NOTE: SHELF MOUNTING HT. SHALL BE <br />DETERMINED ON SITE. BASED ON REQUIRED <br />SPACE FOR EQUIPMENT BELOW <br />EXISTING EXTERIOR <br />WINDOW EXISTING WINDOW MULLION <br />D-1 FRAMING DETAIL - AT EXT. WINDOW JAMB <br />D-2 FRAMING DETAIL - AT EXT. WINDOW <br />D-3 LOW WALL SUPPORT BRACKET <br />p-4 WATER HEATER SHELF DETAIL <br />*NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES <br />AZ.O sc ALE: N.T.s. <br />AZMULL. sc�LE: u.r_s. <br />SCALE: N.I.S.N..s. <br />AZ.O TYPICAL AT ENDS OF LOW WALLSZ.O <br />PROVIDER WORK <br />ROOM <br />132 <br />119 SF <br />1 CONSTRUCTION PLAN <br />A2.0 1 /4" = 1'-0" <br />PLAN NOTES: <br />(BOXED NOTE NUMBERS ARE KEYED TO PLAN) <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK WITH THE BUILDING OWNER <br />WITH REFERENCE TO ROOF WARRANTIES AND/OR THE PRESCRIBED <br />REQUIREMENTS FOR NEW ROOF PENETRATIONS. IN NO CASE SHOULD <br />CONTRACTOR DO ANYTHING TO VOID ROOF WARRANTIES. CONTRACTOR IS <br />REQUIRED TO HAVE BUILDING OWNER'S ROOFING CONTRACTOR MAKE, <br />SUPERVISE, OR APPROVE ALL NEW ROOF PENETRATION. <br />lA THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL MAKE REDLINE <br />AS -BUILT NOTES ON THE DRAWINGS OF ALL DEVIATIONS FROM THE PLANS MADE <br />DURING THE COURSE OF CONSTRUCTION. CONTRACTOR SHALL SUBMIT REDLINE <br />NOTES AND DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF <br />CONSTRUCTION. IF NO DEVIATIONS OR CHANGES HAVE BEEN MADE DURING <br />CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ARCHITECT <br />STATING THAT NO CHANGES WERE MADE. <br />1 B SUBCONTRACTORS SHALL GIVE TO CONTRACTOR PRODUCT LITERATURE FOR <br />INSTALLED EQUIPMENT AND PRODUCTS THAT REQUIRE MAINTENANCE OF ANY <br />TYPE (INCLUDING RELAMP OF LIGHT FIXTURES) AND ANY MAINTENANCE <br />INSTRUCTIONS OR WARRANTIES AND THE CONTRACTOR SHALL OBTAIN PHONE <br />NUMBERS AND ADDRESSES OF CONTACTS FOR REPAIR/MAINTENANCE AND BIND <br />ALL OF THIS INFORMATION IN AN 8 1 /2 X i 1 NOTEBOOK. THIS MANUAL SHALL <br />ALSO INCLUDE A COMPLETE LISTING OF IDENTIFICATION FOR ALL FINISH <br />MATERIALS INCLUDING CEILING TILE, FLOOR TILE AND CARPET, AND PLASTIC <br />LAMINATE AND PAINT. CONTRACTOR SHALL DELIVER THIS PROJECT <br />MAINTENANCE MANUAL TO OWNER AT COMPLETION OF PROJECT. <br />I THIS IS EQUIPMENT OR FURNITURE, NOT CONSTRUCTION. SEE EQUIPMENT/MEP <br />DRAWINGS FOR PREPARATION AND COORDINATION REQUIRED BY <br />CONTRACTOR. ALL SUBCONTRACTORS SHALL CONTACT AND COORDINATE <br />WITH EQUIPMENT SUPPLIER FOR LAYOUT TEMPLATES AND VERIFICATION/REVIEW <br />OF ROUGH -INS. <br />5K GRAB BARS @ HANDICAP TOILETS: <br />1 1 /2" DIA., 1 1 /2" CLEAR FROM WALL. 33"-36" ABOVE FINISHED FLOOR <br />ANCHORED TO SUPPORT 250 LBS. <br />ONE 42" LONG AT SIDE OF TOILET. <br />ONE 36" LONG BEHIND TOILET. <br />(SEE TOILET ROOM DETAILS FOR PLACEMENT.) <br />6A INFILL EXISTING WINDOW OPENING WITH 3 5/8" 25 GA METAL STUDS 24" O.C. W/ 5/8" <br />DRYWALL FINISH. <br />6C SEE DRAWING Al.1 SLAB PLAN FOR NEW WALK EXTENSIONS. <br />6D CHASE WALLS: SEE PARTITION TYPES FOR WALL CONSTRUCTION. <br />6F PROVIDE 3 1 /2" WIDE 12 GA. MTL BLOCKING STRIPS @ MOUNTING LOCATIONS OF <br />ALL RAILINGS, CURTAIN TRACKS, AND OTHER BUILT-IN OR SURFACE -MOUNTED <br />ACCESSORIES. AT CABINETS, PROVIDE 1 X6 FIRE -RETARDANT -TREATED WOOD <br />BACKING. VERIFY SIZE AND LOCATION OF THIS BLOCKING WITH <br />PRODUCT/EQUIPMENT/CABINET INSTALLATION RECOMMENDATIONS OR NEEDS. <br />6K ALL WOOD FRAMING SHALL BE KILN -DRIED AND HAVE A MINIMUM FIBER STRESS <br />OF 1200 PSI. <br />6Q CEILING: SEE SECTIONS AND DETAILS ON REFLECTED CEILING PLAN. DIMENSIONS <br />AND ELEVATIONS SHOWN ON THESE SHEETS ARE FINISHED. ALL CEILING FRAMING <br />TO BE @ 24" O.C. W/GYPSUM BOARD FINISH. <br />6R ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE <br />PRESSURE -TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. <br />6V THE INTENT OF DESIGN IS TO ALIGN NEW WALLS WITH FRAMING AND FINISH OF <br />EXISTING WALLS <br />6X PROVIDE 5/8" THICK, 24" X 24" FIRE RETARDANT TREATED PLYWOOD BEHIND GYP. <br />BOARD FOR WALL HUNG TVs. CENTER TVs ON PLYWOOD. <br />7A SEALANT: APPLY SEALANT AT JOINING OF ALL DISSIMILAR MATERIALS EXPOSED <br />TO WEATHER AND AT GAPS EXPOSED TO VIEW. <br />7B SEALANT: PROVIDE A FULL BED OF SEALANT AT WINDOW AND DOOR FRAMES <br />(INCLUDING THRESHOLD) AND A CONTINUOUS BEAD AT PERIMETER OF EXTERIOR <br />AND INTERIOR WINDOWS AND DOORS. <br />7H SOUND BATT INSULATION IN INTERIOR WALLS AS INDICATED. SEE WALL LEGEND, <br />THIS SHEET, AND WALL TYPES, SHEET AO.4 AND AO.5 <br />8A ALL GLASS IN DOORS OR SIDELIGHTS SHALL BE TEMPERED AND SHALL COMPLY <br />WITH THE FLORIDA BUILDING CODE 2017, SECTION 2406, SAFETY GLAZING. GLASS <br />IN RATED DOORS SHALL COMPLY W/RATING OF DOOR. <br />8B ALL DOOR HARDWARE SHALL MEET CURRENT ADA AND FLORIDA ACCESSIBILITY <br />CODES. <br />8C ALL WINDOW AND DOOR FRAMES SHALL BE SECURED TO SURROUNDING WALL <br />PER MANUFACTURER RECOMMENDATION FOR WIND ZONE. <br />8D EXISTING DOOR TO REMAIN. DOOR TO BE LOCKED & HARDWARE TO BE <br />REMOVED AND OPENINGS CAPPED. CONTINUOUSLY SEAL DOOR USING BASF <br />MASTERSEAL NP 100, INSTALL PER MFG. RECOMMENDATIONS. COLOR TO MATCH <br />DOOR AS CLOSE AS POSSIBLE. <br />8F EXIST ROOF LADDER AND ACCESS HATCH. <br />9B 1 /2" GYP BOARD MAY BE USED ON SIDES AND BOTTOM OF DROPPED SOFFITS <br />UNLESS NOTED OTHERWISE. <br />9C AT ALL CHANGES IN FLOOR MATERIAL, PROVIDE APPROPRIATE ADA-COMPLIANT <br />TRANSITION STRIP. IF AT DOOR, LOCATE DIRECTLY UNDER DOOR. <br />9E WHEN NOT INDICATED ON PLANS, VERIFY COLOR AND PATTERN SELECTIONS <br />WITH OWNER. <br />9K FILL IN DRYWALL AT DEMOLISHED WALL LOCATIONS. TAPE AND FINISH NEW <br />DRYWALL TO BE FLUSH WITH ADJACENT REMAINING WALL. <br />9Y LEAVE 1/2" GAP BETWEEN FINISH FLOOR AND BOTTOM EDGE OF GYPSUM BOARD. <br />9Z PREPARE ALL WALLS FOR PAINT, TO A GA 216 LEVEL 4 DRYWALL FINISH. <br />9N ALL TOILETS: USE 5/8" MOISTURE RESISTANT GYPSUM BOARD ON BATHROOM SIDE OF <br />ALL WALLS BEHIND A TOILET AND/OR LAVATORY. <br />9Q ALL NEW CARPET & WALLPAPER SHALL BE ANTIMICROBIAL TREATED FROM THE <br />FACTORY. <br />IOA PROVIDE AND INSTALL TYPE 2A10 BC FIRE EXTINGUISHER (S) WHERE SHOWN ON <br />PLAN. THE TOP OF FIRE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE <br />FLOOR (3 1 /2 FT. IF FIRE EXTINGUISHER'S GROSS WEIGHT IS MORE THAN 40 LBS) <br />AND BOTTOM NOT LESS THAN 4 INCHES ABOVE THE FLOOR. <br />1 OB RAISED/BRAILLED CHARACTERS & PRACTICAL SYMBOL SIGNS <br />LETTERS AND NUMERALS SHALL BE RAISED 1 /32 IN, UPPER CASE, SANS SERIF OR <br />SIMPLE SERIF TYPE, AND SHALL BE ACCOMPLISHED WITH GRADE 2 BRAILLE. <br />RAISED CHARACTERS SHALL BE AT LEAST 5/8 IN (16 MM) HIGH, BUT NO HIGHER <br />THAN 2 IN (50 MM). PICTOGRAMS SHALL BE ACCOMPLISHED BY THE EQUIVALENT <br />VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER <br />DIMENSION OF THE PICTOGRAM SHALL BE 6 IN (152 MM) MINIMUM IN HEIGHT. <br />MOUNTING LOCATIONS AND HEIGHT <br />SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE <br />TOILET RM DOORS. MOUNTING HEIGHT SHALL BE 60 IN. (1525 MM) ABOVE FINISH <br />FLOOR TO THE CENTERLINE OF THE SIGN. (IF LATCHSIDE UNAVAILABLE USE <br />NEAREST ADJACENT WALL FOR SIGN). OWNER TO PROVIDE. <br />IOC CONTRACTOR TO INSTALL OWNER PROVIDED AED SEMI -RECESSED CABINET <br />11 A CABINETS AND CASE WORK: SEE ALL DRAWINGS FOR CABINET SIZES, FINISHES, <br />HARDWARE AND MATERIALS SPECIFICATIONS. THE CONTRACTOR SHALL SUBMIT <br />SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. <br />1 1 B CABINETS AND CASE WORK PROVIDED BY OWNER, CONTRACTOR TO <br />COORDINATE INSTALLATION W/ OWNER. <br />IIC AT ALL WALLS RECEIVING CABINETS AND CASE WORK, PROVIDE 4'x8'xl /2" FIRE <br />RESISTANT PLYWOOD BACKING ON ALL 4 WALLS. AS REQUIRED. <br />1 1 D TELCOM CLOSET: PROVIDE AND MOUNT (1) SHEET OF 4' X 8' X 1 /2" <br />FIRE -RETARDANT TREATED BC PLYWOOD WITH TOP AT 8'-0" AFF. AT ALL WALLS. <br />12A N/A, <br />12B PROVIDE CAP SHEET FILM TO GLAZING (SOLYX SXWF-WB WHITE BLACK OPAQUE) AT ALL <br />SPANDREL CONDITIONS WHERE INTERIOR WALLS COVER EXTERIOR STOREFRONTS. <br />15A CONTRACTOR TO INSTALL OWNER PROVIDED SOAP DISPENSERS AT EACH SINK <br />AND LAVATORY. <br />15B CONTRACTOR TO INSTALL OWNER PROVIDED DIAGNOSTIC BOARDS IN ALL <br />WELLNESS SUITES. CONTRACTOR TO INSTALL DIAGNOSTIC WALL BOARD BRACKET. SEE <br />DET 2/AO.5 FOR DIAGNOSTIC BOARD NICHE. <br />15C CONTRACTOR TO INSTALL OWNER PROVIDED SHARP CONTAINERS IN ALL <br />WELLNESS SUITES, LAB AND MED ROOM <br />15D CONTRACTOR TO INSTALL OWNER PROVIDED PAPER TOWEL DISPENSERS AT <br />BREAK ROOM AND COMMUNITY ROOM <br />15E CONTRACTOR TO INSTALL OWNER PROVIDED REFRIGERATOR LINES FOR ICE <br />MAKERS IN BREAK ROOM <br />15F CLOSE AND LOCK EXISTING EXTERIOR DOOR. REMOVE LEVER HARDWARE AND CAP. <br />CAULK WITH EXTERIOR RATED BUTYL CAULK. PROVIDE CONTNNIOUS BEAD ALL SIDES <br />AND THRESHOLD INTERIOR AND EXTERIOR. <br />15G PROVIDE RECESSED SPECIMEN PASS -THROUGH CABINET - BOBRICK B-505 <br />CAMPBELL + <br />ARCHITECTURE INTERIOR DESIGN <br />www.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC, <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. LEC. No. AR0016053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />J <br />J <br />J <br />rV <br />a-- <br />n <br />= <br />W <br />F_ <br />IV <br />J <br />J <br />LI_1 <br />W <br />m <br />+ <br />J <br />Zo <br />Q <br />UJ <br />LZLJ�— <br />i <br />Q <br />LLj <br />Cl— <br />O �00 <br />co <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />........................... <br />PROJECT MANAGER <br />M. TORRES <br />......................................... I.......................... <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />CONSTRUCTION PLAN <br />A290 <br />Fgq-&Ejlmll M-10-FN <br />"ma.1, <br />SEMI <br />