My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7866 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7866 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:00:29 AM
Creation date
2/18/2025 3:45:42 PM
Metadata
Fields
Template:
Building Plans
Street #
7866
Location
Gall Blvd
Contractor
IConstructors LLC
Building Plans - Permit #
6055
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�1161661� 1 - 6"'MA .311M I"Ut ",U "L- � 6 1 dA1_ <br />NOTE: ALL PLAN DIMENSIONS ARE TO FACE OF G.W.B. AS <br />ELOOR <br />PLAN SYMBOLS <br />SHOWN BELOW, UNLESS SPECIFICALLY NOTED OTHERWISE. <br />F_#__1 <br />ROOM NUMBER <br />SECTION <br />WINDOW TYPE* <br />ED <br />DOOR SYMBOL- SEE DOOR SCHEDULE <br />5/8" GYP WALL BOARD <br />6 X 6 WELDED WIRE MESH <br />IF MORE THAN 24'WIDE <br />ISTI NG SLAB A MAN 14� WIDIIi <br />DETAIL <br />DOOR CONTACT <br />FINISHED CLEARANCE <br />—ACTUAL <br />L 4 1/2" MAX <br />(2) 3-5/8" METAL STUDS TIGHT TO <br />ADJACENT WALL OR CORNER <br />CHANNEL ANCHOR HOLLOW METAL <br />FRAME TO STUD <br />DOOR OPENING TO BEGIN A <br />MAXIMUM OF 4 1/2" FROM ADJACENT <br />STUD LINE <br />DIMENSIONS ARE TO <br />FACE OF G.W.B. U.N.O. <br />GYP WALL BOARD-�� <br />METAL RUNNERS <br />TOP & BOTT <br />5/8" MTL STUDS <br />U.N.O. <br />J_ <br />4" CONCRETE INFILL <br />'TEx <br />-7 <br />< <br />`0 INSURE STABILITY AT SLAB CONNECTION <br />VAPOR BARRIER <br />—APPLY NEW <br />TERMITE TREATMENT <br />AT ALL AREAS THAT <br />SOIL IS DISTURBED. <br />COMPACTED SOIL <br />CARD READER <br />MINIMUM DIMENSION MAY BE <br />Fc.o. <br />CASED OPENING* <br />VERIFY DIMENSION COMBINED <br />WALL TYPE - SEE WALL LEGEND & SHEET AO.5 <br />�R <br />RADIUS OF CLEARANCE <br />AL <br />ALIGNMENT LINE <br />ITEM ABOVE OR FURNITURE/EQUIPMENT N.I.0 <br />ITEM BELOW <br />F N <br />C_ TERLINE <br />POB <br />POINT OF BEGINNING FOR LAYOUT <br />INTERIOR & CABINET ELEVATIONS <br />*NOTE: SEE SHEET A2.3 FOR DOOR & WINDOW TYPES <br />(1) SIMPSON STRONG -TIE TITEN HD 1" X 4" (MIN.) <br />4 <br />@ 16" O.C. 2" INTO EXISTING SLAB AND EXTEND <br />2" INTO NEW <br />DOOR FRAMING DETAIL - TYPICAL <br />'D- LAYOUT DIMENSION DETAIL <br />(D_4� SLAB INFILL DETAIL <br />*NOTE: SEE SHEET A2.3 FOR DOOR <br />& WINDOW TYPES <br />HINGE SIDE (�d_) DOORS SHOWN SCALE: N.T.S. <br />HORIZONTAL SEC TION SCALE- N.T.S. <br />SIC: 3" - 1'-0" <br />IN CORNER OF ROOM <br />rl'� DIMENSION PLAN <br />1/411 = 1 1-011 <br />PLAN NOTES: <br />(BOXED NOTE NUMBERS ARE KEYED TO PLAN) <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK WITH THE BUILDING OWNER <br />WITH REFERENCE TO ROOF WARRANTIES AND/OR THE PRESCRIBED <br />REQUIREMENTS FOR NEW ROOF PENETRATIONS. IN NO CASE SHOULD <br />CONTRACTOR DO ANYTHING TO VOID ROOF WARRANTIES. CONTRACTOR IS <br />REQUIRED TO HAVE BUILDING OWNER'S ROOFING CONTRACTOR MAKE, <br />SUPERVISE, OR APPROVE ALL NEW ROOF PENETRATION. <br />I A THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL MAKE REDLINE <br />AS -BUILT NOTES ON THE DRAWINGS OF ALL DEVIATIONS FROM THE PLANS MADE <br />DURING THE COURSE OF CONSTRUCTION. CONTRACTOR SHALL SUBMIT REDLINE <br />NOTES AND DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF <br />CONSTRUCTION. IF NO DEVIATIONS OR CHANGES HAVE BEEN MADE DURING <br />CONSTRUCTION, THE CONTRACTOR SHALL SUBMIT A LETTER TO THE ARCHITECT <br />STATING THAT NO CHANGES WERE MADE. <br />I B SUBCONTRACTORS SHALL GIVE TO CONTRACTOR PRODUCT LITERATURE FOR <br />INSTALLED EQUIPMENT AND PRODUCTS THAT REQUIRE MAINTENANCE OF ANY <br />TYPE (INCLUDING RELAMP OF LIGHT FIXTURES) AND ANY MAINTENANCE <br />INSTRUCTIONS OR WARRANTIES AND THE CONTRACTOR SHALL OBTAIN PHONE <br />NUMBERS AND ADDRESSES OF CONTACTS FOR REPAIR/MAINTENANCE AND BIND <br />ALL OF THIS INFORMATION IN AN 8 1/2 X 11 NOTEBOOK. THIS MANUAL SHALL <br />ALSO INCLUDE A COMPLETE LISTING OF IDENTIFICATION FOR ALL FINISH <br />MATERIALS INCLUDING CEILING TILE, FLOOR TILE AND CARPET, AND PLASTIC <br />LAMINATE AND PAINT. CONTRACTOR SHALL DELIVER THIS PROJECT <br />MAINTENANCE MANUAL TO OWNER AT COMPLETION OF PROJECT. <br />I C THIS IS EQUIPMENT OR FURNITURE, NOT CONSTRUCTION. SEE EQUIPMENT/MEP <br />DRAWINGS FOR PREPARATION AND COORDINATION REQUIRED BY <br />CONTRACTOR. ALL SUBCONTRACTORS SHALL CONTACT AND COORDINATE <br />WITH EQUIPMENT SUPPLIER FOR LAYOUT TEMPLATES AND VERIFICATION/REVIEW <br />OF ROUGH -INS. <br />5K GRAB BARS @ HANDICAP TOILETS: <br />1 1/2" DIA., 1 1/2" CLEAR FROM WALL. 33"-36" ABOVE FINISHED FLOOR <br />ANCHORED TO SUPPORT 250 LBS. <br />ONE 42" LONG AT SIDE OF TOILET. <br />ONE 36" LONG BEHIND TOILET. <br />(SEE TOILET ROOM DETAILS FOR PLACEMENT.) <br />6A INFILL EXISTING WINDOW OPENING WITH 3 5/9'25 GA METAL STUDS 24" O.C. W/ 5/8" <br />DRYWALL FINISH. <br />6C PROVIDE 4" REINFORCED CONCRETE WALK PAD FROM EXTERIOR TO BACK OF CURB IF <br />NOT ALREADY PROVIDED. <br />6D CHASE WALLS: SEE PARTITION TYPES FOR WALL CONSTRUCTION. <br />6F PROVIDE 3 1/2" WIDE 12 GA. MTL BLOCKING STRIPS @ MOUNTING LOCATIONS OF <br />ALL RAILINGS, CURTAIN TRACKS, AND OTHER BUILT-IN OR SURFACE -MOUNTED <br />ACCESSORIES. AT CABINETS, PROVIDE 1X6 FIRE-RETA RDA NT-TREATED WOOD <br />BACKING. VERIFY SIZE AND LOCATION OF THIS BLOCKING WITH <br />PROD U CT/EQU IPMENT/CA BIN ET INSTALLATION RECOMMENDATIONS OR NEEDS. <br />6K ALL WOOD FRAMING SHALL BE KILN -DRIED AND HAVE A MINIMUM FIBER STRESS <br />OF 1200 PSI. <br />6Q CEILING: SEE SECTIONS AND DETAILS ON REFLECTED CEILING PLAN. DIMENSIONS <br />AND ELEVATIONS SHOWN ON THESE SHEETS ARE FINISHED. ALL CEILING FRAMING <br />TO BE @ 24" O.C. W/GYPSUM BOARD FINISH. <br />6R ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE <br />PRESSURE -TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. <br />6V THE INTENT OF DESIGN IS TO ALIGN NEW WALLS WITH FRAMING AND FINISH OF <br />EXISTING WALLS <br />6X PROVIDE 5/9'THICK, 24" X 24" FIRE RETARDANT TREATED PLYWOOD BEHIND GYP. <br />BOARD FOR WALL HUNG TVs. CENTER TVs ON PLYWOOD. <br />7A SEALANT: APPLY SEALANT AT JOINING OF ALL DISSIMILAR MATERIALS EXPOSED <br />TO WEATHER AND AT GAPS EXPOSED TO VIEW. <br />7B SEALANT: PROVIDE A FULL BED OF SEALANT AT WINDOW AND DOOR FRAMES <br />(INCLUDING THRESHOLD) AND A CONTINUOUS BEAD AT PERIMETER OF EXTERIOR <br />AND INTERIOR WINDOWS AND DOORS. <br />7H SOUND BATT INSULATION IN INTERIOR WALLS AS INDICATED. SEE WALL LEGEND, <br />THIS SHEET, AND WALL TYPES, SHEET AO.4 AND AO.5 <br />8A ALL GLASS IN DOORS OR SIDELIGHTS SHALL BE TEMPERED AND SHALL COMPLY <br />WITH THE FLORIDA BUILDING CODE 2017, SECTION 2406, SAFETY GLAZING. GLASS <br />IN RATED DOORS SHALL COMPLY W/RATING OF DOOR. <br />8B ALL DOOR HARDWARE SHALL MEET CURRENT ADA AND FLORIDA ACCESSIBILITY <br />CODES. <br />8C ALL WINDOW AND DOOR FRAMES SHALL BE SECURED TO SURROUNDING WALL <br />PER MANUFACTURER RECOMMENDATION FOR WIND ZONE. <br />8D EXISTING DOOR TO REMAIN. DOOR TO BE LOCKED & HARDWARE TO BE <br />REMOVED AND OPENINGS CAPPED. CONTINUOUSLY SEAL DOOR USING BASF <br />MASTERSEAL NP 100, INSTALL PER MFG. RECOMMENDATIONS. COLOR TO MATCH <br />DOOR AS CLOSE AS POSSIBLE. <br />8F PROVIDE WINDOW SILLS (MATCH EXISTING BUILDING STANDARD) @ INTERIOR OF <br />EACH WINDOW UNIT NOTED. <br />9B 1/2" GYP BOARD MAY BE USED ON SIDES AND BOTTOM OF DROPPED SOFFITS <br />UNLESS NOTED OTHERWISE. <br />9C AT ALL CHANGES IN FLOOR MATERIAL, PROVIDE APPROPRIATE ADA-COMPLIANT <br />TRANSITION STRIP. IF AT DOOR, LOCATE DIRECTLY UNDER DOOR. <br />9E WHEN NOT INDICATED ON PLANS, VERIFY COLOR AND PATTERN SELECTIONS <br />WITH OWNER. <br />9K FILL IN DRYWALL AT DEMOLISHED WALL LOCATIONS. TAPE AND FINISH NEW <br />DRYWALL TO BE FLUSH WITH ADJACENT REMAINING WALL. <br />9Y LEAVE 1/2" GAP BETWEEN FINISH FLOOR AND BOTTOM EDGE OF GYPSUM BOARD. <br />9z PREPARE ALL WALLS FOR PAINT, TO A GA 216 LEVEL 4 DRYWALL FINISH. <br />9N ALL TOILETS: USE 5/8" MOISTURE RESISTANT GYPSUM BOARD ON BATHROOM SIDE OF <br />ALL WALLS BEHIND A TOILET AND/OR LAVATORY. <br />9Q ALL NEW CARPET & WALLPAPER SHALL BE ANTIMICROBIAL TREATED FROM THE <br />FACTORY. <br />I OA PROVIDE AND INSTALL TYPE 2A 10 BC FIRE EXTINGUISHER (S) WHERE SHOWN ON <br />PLAN. THE TOP OF FIRE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE <br />FLOOR (3 1/2 FT. IF FIRE EXTINGUISHER's GROSS WEIGHT IS MORE THAN 40 LBS) <br />AND BOTTOM NOT LESS THAN 4 INCHES ABOVE THE FLOOR. <br />IOB RAISED/BRAILLED CHARACTERS & PRACTICAL SYMBOL SIGNS <br />LETTERS AND NUMERALS SHALL BE RAISED 1/32 IN, UPPER CASE, SANS SERIF OR <br />SIMPLE SERIF TYPE, AND SHALL BE ACCOMPLISHED WITH GRADE 2 BRAILLE. <br />RAISED CHARACTERS SHALL BE AT LEAST 5/8 IN (16 MM) HIGH, BUT NO HIGHER <br />THAN 2 IN (50 MM). PICTOGRAMS SHALL BE ACCOMPLISHED BY THE EQUIVALENT <br />VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER <br />DIMENSION OF THE PICTOGRAM SHALL BE 6 IN (152 MM) MINIMUM IN HEIGHT. <br />MOUNTING LOCATIONS AND HEIGHT <br />SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE <br />TOILET RM DOORS. MOUNTING HEIGHT SHALL BE 60 IN. (1525 MM) ABOVE FINISH <br />FLOOR TO THE CENTERLINE OF THE SIGN. (IF LATCHSIDE UNAVAILABLE USE <br />NEAREST ADJACENT WALL FOR SIGN). OWNER TO PROVIDE. <br />10C CONTRACTOR TO INSTALL OWNER PROVIDED AED SEMI -RECESSED CABINET <br />11A CABINETS AND CASE WORK: SEE ALL DRAWINGS FOR CABINET SIZES, FINISHES, <br />HARDWARE AND MATERIALS SPECIFICATIONS. THE CONTRACTOR SHALL SUBMIT <br />SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. <br />11B CABINETS AND CASE WORK PROVIDED BY OWNER, CONTRACTOR TO <br />COORDINATE INSTALLATION W/ OWNER. <br />1IC AT ALL WALLS RECEIVING CABINETS AND CASE WORK, PROVIDE 4'x8'xl /2" FIRE <br />RESISTANT PLYWOOD BACKING ON ALL 4 WALLS. AS REQUIRED. <br />11D TELCOM CLOSET: PROVIDE AND MOUNT (1) SHEET OF WX 8'X 1/2" <br />FIRE -RETARDANT TREATED BC PLYWOOD WITH TOP AT 8'-0" AFF. AT ALL WALLS. <br />12A PROVIDE NEW WINDOW TREATMENTS, ROLLER SHADE SYSTEM. SEE FINISH LEGEND. <br />12B PROVIDE CAP SHEET FILM SOLYX SXWF-WB WHITE BLACK OPAQUE AT EXISTING <br />WINDOW INTERIOR <br />15A CONTRACTOR TO INSTALL OWNER PROVIDED SOAP DISPENSERS AT EACH SINK <br />AND LAVATORY. <br />15B CONTRACTOR TO INSTALL OWNER PROVIDED DIAGNOSTIC BOARDS IN ALL <br />WELLNESS SUITES. CONTRACTOR TO INSTALL DIAGNOSTIC WALL BOARD BRACKET. SEE <br />DET 2/AO.5 FOR DIAGNOSTIC BOARD NICHE. <br />15C CONTRACTOR TO INSTALL OWNER PROVIDED SHARP CONTAINERS IN ALL <br />WELLNESS SUITES, LAB AND MED ROOM <br />15D CONTRACTOR TO INSTALL OWNER PROVIDED PAPER TOWEL DISPENSERS AT <br />BREAK ROOM AND COMMUNITY ROOM <br />15E CONTRACTOR TO INSTALL OWNER PROVIDED REFRIGERATOR LINES FOR ICE <br />MAKERS IN BREAK ROOM <br />15F CLOSE AND LOCK EXISTING EXTERIOR DOOR. REMOVE LEVER HARDWARE AND CAP. <br />CAULK WITH EXTERIOR RATED BUTYL CAULK. PROVIDE CONTINIOUS BEAD ALL SIDES <br />AND THRESHOLD INTERIOR AND EXTERIOR. <br />CAMPBELL + VAN DUSEN <br />ARCHITECTURE INTERIOR DESIGN <br />www.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC. <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AR001 6053 <br />A, <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FLLIC NO. AR0016053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />_j <br />LL_ <br />CL <br />LU <br />c) <br />r) <br />Uj <br />LLJ <br />+ <br />LO <br />LU <br />LLj <br />0 <br />n <br />LU <br />NO 'q- <br />'0 Lo <br />0:� <br />0- <br />LU <br />r_4 <br />00 (y) <br />r1_1 (y) <br />CONSTRUCTION DOCUMENTS <br />03.24.2023 <br />DESCRIPTION <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />.................................................................... <br />PROJECT MANAGER <br />M. TORRES <br />.................................................................... <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />DIMENSION PLAN <br />A2.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.