7866 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
7866 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:00:29 AM
Creation date
2/18/2025 3:45:42 PM
Metadata
Fields
Template:
Building Plans
Street #
7866
Location
Gall Blvd
Contractor
IConstructors LLC
Building Plans - Permit #
6055
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FILL VOID WITH BATT INSULATION. <br />PROVIDE 2 LAYERS 5/8" GYP. BOARD <br />AS VERTICAL SOUND WALL I I <br />BETWEEN ROOF DECK AND RTU. COMPRESSOR <br />2X6 P.T. WOOD CURB FRAMING ALL SECTION <br />Su <br />E <br />m <br />CT' <br />10 <br />N <br />J" <br />AROUND BASE OF CURB BOLTED THROUGH CURB <br />r W <br />ROOF DECK AND STRUCTURE BELOW 14"MIN. <br />.0 <br />DO NOT REMOVE ROOF DECK IN ANY <br />AREAS OTHER THAN WHERE DUCTS <br />PENETRATE ROOF. ROOF DECK MUST N'_ <br />REMAIN UNDER COMPRESSOR SECTION. <br />SUPPLY DUCT. SIZE �) _j <br />AS SHOWN ON PLANS <br />INSTALL ALL TRUNK DUCTS TIGHT TO BASE OF BAR <br />JOISTS WELL CLEAR OF ALL LIGHTS <br />PLUMBING AND <br />DOFTOP UNITAS SPECIFIED <br />OUTSIDE AIR HOOD WITH DAMPER <br />ROOF CURB WITH P.T. WOOD NAILER <br />WELDED 18 Ga. GALVANIZED SHELL <br />1 1/2"THK. 3 LB. RIGID INSULATION <br />REFER TO TYPICAL CURB FLASHING <br />DETAIL FOR ADDITIONAL REQUIREMENTS <br />INSULATION AND METAL DECKING AS <br />SPECIFIED BY ARCH. <br />ROOF SURFACE AS SPECIFIED BY ARCH. <br />BAR JOISTS <br />---TRANSITION RETURN DUCT. SIZE AS <br />SHOWN ON PLANS <br />CEILING SPECIFIED <br />Ile BY ARCH. <br />. <br />NOTE: <br />ELEC. CONFLICTS. SUPPORT ALL DUCTS FROM BAR <br />JOISTS OR STRUCTURAL BEAMS ABOVE. REFER TO CURBS TO BE CONSTRUCTED TO MATCH SLOPE OF ROOF AND PROVIDE LEVEL TOP SURFACE. MINIMUM HEIGHT (MEASURED <br />SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. FROM SHORTEST DIMENSION) SHALL BE 14' ABOVE ROOF INSULATION. CURBS TO BE INSTALLED I.A.W. MANUFACTURERS <br />INSTRUCTIONS. CURB SIZES TO BE COORDINATED BY CURB MANUFACTURER, GENERAL CONTRACTOR AND MECHANICAL <br />PROVIDE DUCT MOUNTED SMOKE DETECTOR IN THE CONTRACTOR. CURB LOCATIONS ARE TO BE AS SHOWN ON PLANS. COORDINATE ROOF OPENINGS WITH DUCTWORK AND <br />SUPPLY AIR DUCTWORK OF ALL UNITS IN EXCESS OF ROOFTOP UNIT ORIENTATION. MECHANICAL CONTRACTOR TO PROVIDE ROOFTOP UNIT, ROOF CURB, AND ALL DUCTING. <br />2000 CFM. ROOFING CONTRACTOR TO INSTALL FLASHING AND COUNTERFLASHING FOR ROOFING. <br />ROOFTOP UNIT AND CURB DETAIL <br />SCALE: NTS <br />ROOF MOUNTED CONDENSING UNIT <br />-EXISTING STEEL BEAM <br />SUPPORT (TYPICAL) <br />"EXISTING WELDS <br />(TYPICAL) <br />#10 SELF -TAPPING <br />SCREW 2 PER <br />CORNER (TOTAL OF 8) <br />2"x2mxl 6 GAUGE <br />ANGLE IRON MIN. <br />3/8p BOLT, NUT AND <br />WASHERS 2 PER <br />CORNER (TOTAL OF 8) <br />EXISTING PIPE <br />COLUMN SUPPORT <br />/-EXISTING ROOF <br />NOTE: <br />IT IS THE INTENT OF THIS DETAIL THAT THE <br />CONTRACTOR PROPERLY INSTALL THE <br />CONDENSER TO COMPLY WITH 140 MPH WIND <br />LOADING PER 2017 FLORIDA BUILDING AND <br />MECHANICAL CODES. <br />ROOF MOUNTED CONDENSING UNIT DETAIL <br />WIDTH OF <br />MECHANICALUNIT- <br />MINIMUM CLEARANCE <br />ABOVE ROOF SURFACES <br />< 24" 24" <br />14" <br />< 36" 36" <br />18" <br />< 48"48" <br />24" <br />< 60"> <br />30" <br />60" <br />48" <br />PROVIDE MOUNTING BRACKET AND <br />BLOCKING AS REQUIRED FOR <br />SUPPORT OF UNIT <br />AIR FLOW <br />I LCIVULIL I <br />FIELD VERIFY <br />CONTINUATION OF <br />CONDENSATE PIPING <br />RETURN <br />DUCTWORK <br />1/2"CONDENSATE LINE WITH <br />INSULATION DOWN IN WALL <br />AND THRU FLOOR <br />CONDENSATE LINE <br />THRU WALL <br />PROVIDE P-TRAP FOR <br />CONDENSATE REMOVAL. <br />REFER TO DETAIL. <br />MIN[ -CONDENSATE PUMP <br />IANT OR APPROVED EQUAL <br />FILL WITH FOAM AND <br />URETHANE AFTER PIPE <br />INSTALLATION <br />PIPING PENTHOUSE DETAIL <br />DUCTLESS SPLIT SYSTEM AHU DETAIL <br />bL;ALt: NlZ5 <br />Lt�YVUL I ZjL;ALt: NIb <br />SEE BEAM CLAMP DETAIL <br />SEE BEAM CLAMP DETAIL <br />SEE BEAM CLAMP DETAIL SEE BEAM CLAMP DETAIL <br />SPIN -IN COLLAR <br />DUCT <br />1-1/2"MIN. <br />SEAL ALL JOINTS. <br />#8 WIRE OR 1-1/2" <br />STRAP HANGER <br />MIN. STRAP <br />FLEX DUCT <br />HANGER <br />SPIN -IN COLLAR <br />SEAL ALL JOINTS. <br />2"x7x4" 13Y 22GA. <br />---------------- <br />DUCT--,, <br />-------- <br />ANGLE AT BOTTOM CORNERS <br />MINIMUM OF THREE <br />FASTENERS, NO. 10, 3/4" <br />SCREWS WITH TWO INSTALLED <br />CHANNEL MAY BE USED IN LIEU <br />ON SIDES AND ONE ON BOTTOM <br />FLEX DUCT <br />RIGID RECTANGULAR DUCT <br />OF SHEETMETAL ANGLES <br />FASTENING STRAP <br />NO FASTENERS PERMITTED IN DUCT FIBROUS RECTANGULAR DUCT <br />FASTENING STRAP <br />SEE BEAM CLAMP DETAIL <br />SEE BEAM CLAMP DETAIL <br />SE E <br />2" MIN. SUPPORT STRAP <br />2" MI <br />11 <br />1-1/2" MIN. SUPPORT <br />OT To <br />FLEXIBLE DUCT SHALL NOT TO <br />18"MA <br />18"MAX. FROM DEVICE <br />T <br />STRAP 18"MAX. FROM <br />AX <br />EXCEED 1/2" PER FOOT MAX <br />M <br />AND 5'-0" ON CENTER <br />AND 51 <br />DEVICE. <br />DE <br />MAXIMUM ALLOWABLE <br />LENGTH OF FLEX DUCT <br />6 <br />1 <br />9 <br />"11�61�0" <br />" <br />FLEX DUCT <br />DUCT <br />MAINTAIN RADIUS OF BEND <br />TO NOT LESS THAN ONE <br />DUCT DIAMETER FLEX DUCT <br />DUCTWORK SUPPORT DETAILS <br />SCALE: NTS <br />WHERE W/H 4 <br />R/H 1 <br />UH 1.5 <br />RETANGULAR DUCT WITH 4-900 SMOOTH <br />RADIUS ELLS TO AVOID OBSTRUCTION <br />VELOCITY <br />FPM <br />800 <br />1200 <br />1600 <br />2000 <br />2400 <br />(M/S) <br />(4) <br />(6) <br />(8) <br />(10) <br />(12) <br />C <br />0.18. <br />0.22 <br />1 0.24 <br />0.25 <br />0.26 <br />W"l< <br />L <br />B <br />WHERE W/H 1.0 TO 3.0 <br />B = 12" TO 24" <br />RETANGULAR DUCT WITH 4-900 MITERED ELL TO AVOID OBSTRUCTION <br />COEFFICIENT C <br />UH RATIO <br />0.5 <br />1.0 <br />1.5 <br />2 <br />SINGLE BLADE TURNING VANES <br />- <br />0.86 <br />0.83 <br />0.77 <br />DOUBLE BLADE TURNING VANES <br />- <br />1.85 <br />2.84 <br />2.91 <br />"S" TYPE SPUTTER VANES <br />0.61 <br />0.65 <br />- <br />- <br />NO VANES - UP TO 1200 FPM M/S <br />0.88 <br />5.26 <br />6.92 <br />7.56 <br />NO VANES - OVER 1200 FPM M/S) <br />1.26 <br />6.22 <br />8.82 <br />9.24 <br />TYPICAL DUCTWORK OFFSETS FOR OBSTRUCTIONS <br />SCALE: NTS <br />FASTENERS NOT PERMITTED <br />TO PENETRATE EXHAUST OR <br />DRYER VENT DUCTS. <br />RETANGULAR DUCT, DEPRESSED <br />TO AVOID AN OBSTRUCTION <br />COEFFICIENT C <br />W/H <br />UH <br />0.121%1 <br />0.15 <br />0.25 <br />0.30 <br />1 1.0 <br />0.26 <br />0.30 <br />0.33 <br />035 <br />0.10, <br />0.14 <br />0.22 <br />0.30 <br />PAINT INTERIOR OF DUCT BLACK. <br />USE NON -TOXIC PAINT <br />N <br />EQUAL TO NECK SIZE <br />T-BAR 'N--ACOUSTICAL <br />RETURN/EXHALIST AIR CEILING TILE <br />DEVICE (SEE SCHEDULE) <br />RETURN GRILLE DETAIL <br />SCALE: NTS <br />16 OZ. COPPER OR 24 <br />GA. ST. STEEL OR 040 <br />ALUMINUM <br />GOOSENECK <br />SEAL ALL EDGES <br />AFTER PIPE <br />INSTALLATION <br />ALL JOINTS TO BE <br />SOLDERED OR <br />HELIARCH WELDED <br />FSEE SPECS. FOR <br />TYPE OF ROOF <br />CEILING CABINET <br />EXHAUST FAN <br />INTEGRAL <br />BACKDRAFT <br />DAMPER <br />WIRE SUPPORTS <br />TYPICAL OF 4. <br />CEILING <br />SEE PLAN FOR <br />DUCT SIZE. <br />CEILING CABINET EXHAUST FAN DETAIL <br />La)voutl SCALE: NTS <br />I Lavbutl <br />Lid FLEXIBLE DUCT SAG NOT TO SEAL AIRTIGHT WITH GLASS <br />EXCEED 1/2" PER 10 FEET MAX. FAB AND MASTIC (TYPICAL) <br />CONICAL TYPE <br />SPIN -IN FITTING WITH HANGER (TYP.) <br />INSULATION VOLUME DAMPER <br />SUPPORT <br />STRAP FLEX DUCT <br />DUCT AXIMUM ALLOWABLE <br />M <br />LENGTH OF FLEX. DUCT <br />61-0" <br />SEAL AIRTIGHT <br />ONTRACTOR SHALL PROVIDE A CEILING DIFFUSER <br />STAND-OFF SPIN -IN SO THE <br />INSULATE BACK AS <br />BALANCING DAMPER HANDLE IS <br />EASILY ACCESSIBLE FROM THE PER SPECIFICATIONS <br />EXTERIOR OF THE INSULATION. <br />CEILING <br />LAY -IN CEILING T-BAR FRAME <br />THROAT TO BE DIFFUSER AND HANGER <br />A MINIMUM OF <br />NOTE: 1 x DIAMETER <br />PROVIDE TAPERED RECTANGULAR TO ROUND SIDE TAKEOFF FITTINGS WHERE DUCT DIMENSION <br />DOES NOT PERMIT CONICAL FITTING. <br />LAY -IN CEILING DIFFUSER DETAIL <br />La)voutl SCALE: NTS Lavouti <br />SEAL AIRTIGHT WITH GLASS FAB AND MASTIC <br />CONICAL TYPE <br />SPIN -IN FITTING WITH <br />VOLUME DAMPER <br />DRAWBAND CLAMP <br />INSULATED FLEX DUCT <br />CLASS1 <br />TO AIR DEVICE <br />'j- <br />MAIN BRANCH SEAL DUCT INSULATION TO INSULATED <br />FLEX DUCT WITH GLASS FAB AND MASTIC <br />CONTRACTOR SHALL PROVIDE A STAND-OFF SPIN -IN SO <br />ACCESSIBLE FROM THE EXTERIOR OF THE INSULATION. <br />THE BALANCING DAMPER HANDLE IS EASILY <br />SPIN -IN COLLAR FITTING DETAIL W/ STAND-OFF <br />T-La)voUtl SCALE: NTS <br />BRANCH DUCT <br />x <br />PIVOT DAMPER (VD) 10- Uj <br />(0 W <br />BEARING QUADRANT <br />LOCKING LEVER <br />TRUNK DUCT ANGULAR TAP <br />COLLAR <br />EAIR FLOW (SUPPLY) <br />AIR�FLOW (RETURN/EXHAUST) <br />0 A <br />DUCTWORK BRANCH DETAIL <br />SCALE: NTS M4 <br />I Lavbutl <br />MEP CONSULTING <br />ENGINEERS <br />SINCE 1977 <br />FL REG NO. 3W9 <br />2016 ALDEN RD. <br />ORLANDO, FL <br />32803 <br />(407) 2M-16M <br />WWW.PEIFLA.COM <br />PEI PROJECT f <br />22121 <br />CAMPBELL + VAN DUSEN <br />A R C. H I I F (7 Y 1, 1 � F 1',JT=Plr.R r)Fc,l_r4N <br />www.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC. <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AA26003339 <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FL LIC NO. AR001 6053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />Ile . ..... ........ <br />0 <br />E N 8��� <br />No. 900" -k <br />TATE OF <br />1% s <br />vb�%. V, / <br />.......... N <br />�%NA\- \\N <br />Taylor J. Lewis, PE, <br />FL Reg. No. 9W18 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGINEER OF RECORD <br />LL_ <br />I <br />V) <br />Z <br />>_ <br />0 <br />0- <br />Uj <br />C) <br />< <br />0 <br />C.") <br />LjLj <br />L.0 <br />> <br />__j <br />+ <br />Lr) <br />-'0 <br />cle <br />< <br />LU <br />LU <br />I <br />0 <br />> <br />I <br />LU <br />"o <br />No LO <br />13e <br />CL <br />< <br />LU <br />or-01 (C'2) <br />r14 <br />CONSTRUCTION <br />DOCUMENTS <br />03.24.2023 <br />PRINCIPAL IN CHARGE <br />F... CAM . P.BE.L.L ................................................... <br />. ...... . .. . <br />PROJECT MANAGER <br />M. TORRES <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />MECHANICAL <br />DETAILS <br />M490 <br />