My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7866 Gall Blvd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
7866 Gall Blvd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:02:07 AM
Creation date
2/18/2025 3:46:18 PM
Metadata
Fields
Template:
Building Plans
Street #
7866
Location
Gall Blvd
Contractor
IConstructors LLC
Building Plans - Permit #
6055
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
It <br />0 <br />9 <br />(>1/4m <br />NORTH SCALE: 1/4" = 1'-0" <br />rn <br />r <br />I NOTES TO PLAN REVIEWER I <br />THIS PROJECT HAS BEEN DESIGNED MECHANICALLY TO COMPLY WITH THE 2020 FLORIDA <br />BUILDING CODE (SEVENTH EDITION) — MECHANICAL AS WELL AS THE 2020 FLORIDA BUILDING <br />CODE (SEVENTH EDITION) — EXISTING BUILDING. THE FOLLOWING SECTIONS ARE INDICATED FOR <br />REFERENCE. <br />SECTION 408 MECHANICAL <br />408.1 GENERAL. EXISTING MECHANICAL SYSTEMS UNDERGOING REPAIR SHALL NOT MAKE <br />THE BUILDING LESS CONFORMING THAN IT WAS BEFORE THE REPAIR WAS UNDERTAKEN. <br />PER FLORIDA BUILDING CODE — MECHANICAL <br />SECTION 301 GENERAL <br />301.14 REPAIR. DEFECTIVE MATERIAL OR PARTS SHALL BE REPLACED OR REPAIRED IN <br />SUCH A MANNER SO AS TO PRESERVE THE ORIGINAL APPROVAL OR LISTING. <br />IT IS THE INTENT OF PENINSULA ENGINEERING, INC. TO BRING NEW AND/OR RENOVATED <br />MECHANICAL SYSTEMS TO COMPLIANCE WITH CURRENT CODE REQUIREMENTS. EXISTING <br />MECHANICAL SYSTEMS NOT BEING RENOVATED, REPAIRED, OR ALTERED SHALL BE LEFT IN <br />AS —IS CONDITION WITH THE UNDERSTANDING THAT SUCH CONDITIONS MET CODE REQUIREMENTS <br />AT THE TIME OF INSTALLATION AND, THEREFORE, DO NOT REQUIRE ALTERATIONS FOR THE <br />PURPOSE OF THE SCOPE OF THIS PROJECT. <br />KEY NOTES <br /><D NEW SUPPLY AND RETURN DUCTWORK UP TO NEW ROOFTOP PACKAGE UNIT ABOVE. <br />EXHAUST DUCT UP THROUGH ROOF TO GOOSENECK. <br />CEILING MOUNTED CABINET EXHAUST FAN. PROVIDE NTH INTEGRAL MOTION SENSOR. <br />CEILING MOUNTED CABINET EXHAUST FAN. FAN SHALL RUN CONTINUOUSLY, INTERLOCK WITH <br />ASSOCIATED AIR HANDLING UNIT. <br />ALL THERMOSTATS SHOWN ARE TEMPERATURE SENSORS ONLY. SENSORS SHALL REPORT <br />BACK TO MAIN TEMPERATURE CONTROL PANEL LOCATED IN MANAGER'S OFFICE. <br />MAIN TEMPERATURE CONTROL PANEL PANEL SHALL BE CAPABLE OF ILLUSTRATING THE <br />TEMPERATURE AT EACH SENSOR AS WELL AS SETTING THE TEMPERATURE AT EACH <br />SENSOR. <br />(D DUCTLESS SPLIT AC UNIT HIGH ON WALL PROVIDE CONDENSING UNIT ON -ROOF AND ROUTE <br />CONDENSATE TO NEAREST CONDENSATE REMOVAL LOCATION (STORM WATER SYSTEM). <br />ILFA <br />I q_l <br />F <br />F F <br />F <br />0 0 <br />00 0 00 1 <br />00 0 0 00 <br />oe 0 <br />100 <br />CAMPBELL + VAN DUSEN <br />IARCHITECTURE INTERIOR DESIGN <br />wvvw.CVDstudio.com <br />CAMPBELL + VAN DUSEN Design Studio, LLC. <br />255 South Orange Avenue Suite # 1240 <br />Orlando, Florida 32801 <br />Phone: 407.930.6016 <br />FL. Lic. No. AA26003339 <br />ARCHITECT OF RECORD <br />FRANK W. CAMPBELL AIA <br />FL LIC NO. AR001 6053 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ARCHITECT OF RECORD <br />o\1111111//111, <br />................ <br />C E IV <br />No. 90018 <br />'AO I. STATE OF <br />,4V- -Z <br />ip 4 0 R I <br />............ .... <br />0 A If A L' <br />Ta�or J. Lewis, PE, <br />FL Reg. No. 90018 <br />COPY OF THIS PLAN IS NOT VALID UNLESS SIGNED, <br />SEALED AND DATED BY THE ENGWEER OF RECORD <br />—1 <br />Ll- <br />c/i <br />_j <br />0 <br />F— <br />CL <br />CL <br />ry <br />U <br />< <br />ci <br />C/) <br />Uj <br />LU <br />> <br />_j <br />0 <br />co <br />+ <br />L0 <br />_j <br />__j <br />U <br />"o <br />< <br />LU <br />LLj <br />I <br />0 <br />0 <br />> <br />I <br />0 <br />LU <br />'0 Lf) <br />W <br />< <br />3�-' <br />or-2 (('Y'r)) <br />CL <br />ru-J4 <br />CONSTRUCTION DOCUMENTS <br />03.24.2023 <br />IPTI <br />PRINCIPAL IN CHARGE <br />F. CAMPBELL <br />. ................. ................................................ <br />PROJECT MANAGER <br />M. TORRES <br />............................... .................... I .......... <br />ADVENT HEALTH <br />WELL 65+ <br />ZEPHYRHILLS <br />22-0328-01 <br />MECHANICAL <br />RENOVATION <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.