Laserfiche WebLink
% A 1/G! <br />EN*, <br />►d <br />N <br />t` <br />d- <br />co <br />v <br />H <br />v <br />v <br />Q <br />0. <br />RECEPTACLES <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />(� <br />DUPLEX RECEPTACLE 120V, 20A <br />18" AFF OR AS NOTED <br />,y <br />DUPLEX RECEPTACLE 120V, 20A <br />44" AFF OR 6" ABOVE <br />t� <br />(COUNTER HEIGHT (TYP•)) <br />COUNTER <br />QUAD RECEPTACLE 120V, 20A <br />18" AFF OR AS NOTED <br />DUPLEX RECEPTACLE W/ USB PORTS <br />18" AFF OR AS NOTED <br />120V, 20A <br />DUPLEX RECEPTACLE <br />AS NOTED <br />V <br />(EXISTING TO REMAIN) <br />DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED <br />(HALF SWITCHED) 120V, 20A <br />DUPLEX RECEPTACLE 120V, 20A <br />CONDUIT ON FLOOR <br />(PEDESTAL BOX) <br />SERVICE FITTING <br />QUADRAPLEX RECEPTACLE <br />CONDUIT ON FLOOR <br />120V, 20A (PEDESTAL BOX) <br />SERVICE FITTING <br />® <br />SPECIAL PURPOSE RECEPTACLE <br />SEE POWER SHEET <br />FOR DETAIL <br />CORD DROP RECEPTACLE <br />SEE POWER SHEET <br />FOR DETAIL <br />DUPLEX <br />EK <br />QUAD <br />FLOOR 120V AND DATA SQUARE <br />FLUSH WITH FLOOR <br />® <br />I CEILING 120V DUPLEX SQUARE <br />FLUSH WITH CEILING <br />RECEPTACLE NOTATIONS <br />GFCI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GFCl/WP <br />GROUND FAULT CIRCUIT INTERRUPTER / WEATHERPROOF <br />WP <br />WEATHERPROOF <br />F <br />FLUSH W/FLOOR <br />ETR <br />EXISTING TO REMAIN <br />LIGHTING CONTROLS <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />SINGLE POLE SWITCH <br />(INDICATES LIGHTS CONTROLLED) <br />48" AFF OR AS NOTED <br />3 WAY SWITCH <br />48" AFF OR AS NOTED <br />DIMMER SWITCH <br />48" AFF OR AS NOTED <br />tic <br />LOW VOLTAGE SWITCH. "LVD" TO <br />48" AFF OR AS NOTED <br />DENOTE LOW VOLTAGE DIMMER. <br />OCCUPANCY SENSOR SWITCH <br />48" AFF OR AS NOTED <br />® <br />OCCUPANCY SENSOR <br />ON CEILING OR <br />AS NOTED <br />E <br />POWER PACK <br />ABOVE CEILING <br />CEILING MOUNTED INTERIOR <br />ON CEILING OR <br />(�} <br />DAYLIGHT HARVESTING <br />AS NOTED <br />V <br />PHOTOCELLSENSOR <br />FIRE ALARM <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />HEAT DETECTOR <br />ON CEILING OR <br />AS NOTED <br />FIRE ALARM SMOKE DETECTOR <br />ON CEILING OR <br />AS NOTED <br />FIRE ALARM SMOKE <br />WALL MTD. 6" <br />DETECTOR (WALL MOUNTED) <br />BELOW CLG. <br />DUCT TYPE SMOKE DETECTOR <br />IN HVAC <br />DUCTWORK <br />FACP <br />FIRE ALARM CONTROL PANEL <br />60" AFF TO TOP <br />OR AS NOTED <br />FAAP <br />FIRE ALARM ANNUNCIATOR <br />60" AFF TO TOP <br />OR AS NOTED <br />® <br />SMOKE DAMPER <br />IN HVAC <br />DUCTWORK <br />(�--� <br />FLOW AND TAMPER SWITCH <br />AS NOTED <br />80" AFF <br />( <br />FIRE ALARM VISUAL STROBE <br />SEE NOTE BELOW <br />FIRE ALARM SPEAKER/VISUAL <br />80" AFF OR <br />STROBE <br />SEE NOTE BELOW <br />FIRE ALARM HORNNISUAL <br />80" AFF OR <br />STROBE <br />SEE NOTE BELOW <br />FIRE ALARM SPEAKER ONLY <br />80" AFF OR <br />SEE NOTE BELOW <br />m <br />FIRE ALARM MANUAL PULL <br />48" AFF OR AS NOTED <br />STATION <br />® <br />DUCT DETECTOR REMOTE <br />48" AFF OR <br />TEST / RESET SWITCH <br />AS NOTED <br />® <br />RELAY MODULE <br />AS NOTED <br />® <br />MONITOR MODULE <br />AS NOTED <br />® <br />DUAL MONITOR MODULE <br />AS NOTED <br />LOW VOLTAGE & DATA <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />NWAP <br />WIRELESS ACCESS POINT <br />AS NOTED <br />LOW VOLTAGE DUPLEX RECEPTACLE <br />(NUMBER DENOTES QUANTITY OF <br />18" AFF OR AS NOTED <br />2 <br />PORTS) <br />• <br />COUNTER HEIGHT, LOW VOLTAGE <br />DUPLEX RECEPTACLE (NUMBER <br />ABOVE COUNTER <br />2 <br />DENOTES QUANTITY OF PORTS <br />TTB <br />TELEPHONE TERMINAL BOARD <br />AS NOTED <br />CABLE TV WALL JACK <br />AS NOTED <br />SECURITY <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />® <br />CARD READER <br />AS NOTED <br />0 <br />DOOR CONTACT <br />72" AFF OR AS NOTED <br />® <br />KEYPAD <br />48" AFF OR AS NOTED <br />® <br />MOTION DETECTOR <br />AS NOTED <br />® <br />ELECTRIC STRIKE <br />AS NOTED <br />INTERIOR LUMINAIRES <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />2x2 LAY -IN FIXTURE <br />SEE FIXTURE <br />EMERGENCY POWER <br />SCHEDULE <br />2x2 LAY -IN FIXTURE <br />SEE FIXTURE <br />(NL - DENOTES NIGHTLIGHT) <br />SCHEDULE <br />2x4 LAY -IN FIXTURE <br />SEE FIXTURE <br />EMERGENCY POWER <br />SCHEDULE <br />2x4 LAY -IN FIXTURE <br />SEE FIXTURE <br />INL <br />(NL - DENOTES NIGHTLIGHT) <br />SCHEDULE <br />®1x4FT <br />STRIP FIXTURE <br />SEE FIXTURE <br />EMERGENCY POWER <br />SCHEDULE <br />® <br />1x4FT STRIP FIXTURE <br />SEE FIXTURE <br />SCHEDULE <br />SEE FIXTURE <br />EMERGENCY FIXTURE <br />SCHEDULE <br />EMERGENCY EXIT <br />SEE FIXTURE <br />COMBINATION FIXTURE <br />SCHEDULE <br />® <br />EXIT FIXTURE - DIRECTION <br />SEE FIXTURE <br />DENOTED <br />SCHEDULE <br />REMOTE EMERGENCY HEAD <br />SEE FIXTURE <br />SCHEDULE <br />SEE FIXTURE <br />-L <br />PENDANT FIXTURE <br />SCHEDULE <br />Q <br />6" DOWN LIGHT (RECESSED) <br />SEE FIXTURE <br />EMERGENCY FIXTURE <br />SCHEDULE <br />4 <br />6 DOWN LIGHT (RECESSED) <br />SEE FIXTURE <br />SCHEDULE <br />LIGHT FIXTURE, WALL BRACKET <br />SEE FIXTURE <br />' Y <br />SCHEDULE <br />LIGHT FIXTURE (EXISTING) <br />--- <br />SEE FIXTURE <br />WALL WASH FIXTURE <br />SCHEDULE <br />SEE FIXTURE <br />ES <br />TRACK FIXTURE <br />SCHEDULE <br />EXHAUST FAN / LIGHT COMBO <br />SEE FIXTURE <br />SCHEDULE <br />EXHAUST FAN <br />SEE FIXTURE <br />SCHEDULE <br />O <br />HIGH BAY FIXTURE (ROUND) <br />SEE FIXTURE <br />SCHEDULE <br />HIGH BAY FIXTURE (RECTANGLE) <br />SEE FIXTURE <br />SCHEDULE <br />CEILING FAN WITH LIGHT <br />5SC FIXTURE <br />SCHEDULE <br />HANGING FIXTURE <br />SEE FIXTURE <br />(CHANDELIER) <br />SCHEDULE <br />EXTERIOR LUMINAIRES <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />SEE FIXTURE <br />POLE MOUNTED LIGHT FIXTURE <br />SCHEDULE <br />SEE FIXTURE <br />I-¢- <br />WALL PACK FIXTURE <br />SCHEDULE <br />® <br />BOLLARD / PATHWAY FIXTURE <br />SEE FIXTURE <br />SCHEDULE <br />((( <br />FLOODLIGHT FIXTURE <br />SEE FIXTURE <br />SCHEDULE <br />I <br />POWER DISTRIBUTION <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />fft <br />METER <br />AS NOTED <br />-in <br />PANELBOARD. 120/208V OR 120/240V <br />SEE PANEL <br />SCHEDULE <br />!� <br />PANELBOARD. 277/480V <br />SEE PANEL <br />SCHEDULE <br />TRANSFORMER <br />AS NOTED <br />DISCONNECT SWITCH <br />AS NOTED <br />-� <br />FUSED DISCONNECT SWITCH. <br />AS NOTED <br />(SIZE / FUSE / # OF POLES) <br />® <br />ENCLOSED CIRCUIT BREAKER. <br />AS NOTED <br />EP <br />DISCONNECT SWITCH WITH <br />AS NOTED <br />MOTOR STARTER. <br />® <br />MOTOR STARTER. <br />AS NOTED <br />Sn <br />MOTOR STARTER SWITCH WITH <br />AS NOTED <br />OVERLOAD RELAYS AS REQUIRED. <br />C� <br />MOTOR. <br />AS NOTED <br />® <br />ELECTRIC DUCT HEATER. <br />AS NOTED <br />® <br />POWER POLE <br />AS NOTED <br />ATS <br />AUTOMATIC TRANSFER SWITCH. <br />AS NOTED <br />FEE <br />MANUAL TRANSFER SWITCH. <br />AS NOTED <br />® /® <br />JUNCTION BOX OR 4 SQUARE BOX. <br />AS NOTED <br />CONDUIT / WIRING AND GROUNDING <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />11 <br />DRIVEN ROD <br />-- <br />(UNLESS NOTED OTHERWISE) <br />CONDUIT CONCEALED IN <br />NUMBER OF WIRES INDICATED <br />f <br />CEILING SPACE OR WALL <br />AS FOLLOWS <br />HOT NEUTRAL <br />CONDUIT CONCEALED IN <br />TWO WIRES i <br />/ <br />CEILING SPACE OR WALL <br />Ho L <br />THREE WIRES -�-�.� "���� <br />HOME RUN TO PANEL <br />(HASH MARKS INDICATE <br />FOUR WIRES H� 4RAL <br />NUMBER OF WIRESI <br />CONDUIT RUN EXPOSED --- <br />LOW VOLTAGE WIRING <br />O CONDUIT RUN UP AS SHOWN <br />• CONDUIT RUN DOWN AS SHOWN <br />MECHANICAL UNITS <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />114/11 <br />AIR HANDLER <br />AS NOTED <br />CU-f <br />1 l <br />h - <br />CONDENSING UNIT <br />AS NOTED <br />RECIRCULATING PUMP <br />AS SHOWN <br />• • <br />INSTA-HOT WATER HEATER <br />AS SHOWN <br />CC ELECTRICAL DEVICES TO BE REMOVED OR RELOCATED <br />ELECTRICAL DEVICES TO REMAIN <br />NEW ELECTRICAL DEVICES <br />OO REFERS TO LIKE NUMBER KEY NOTES <br />NOTE: <br />ALL ITEMS IN LEGEND MAY NOT NECESSARILY APPEAR ON THE PLANS. <br />ABBREVIATIONS <br />AFC <br />- AVAILABLE FAULT CURRENT <br />AFF <br />- ABOVE FINISHED FLOOR <br />AHU <br />- AIR HANDLING UNIT <br />BFG <br />- BELOW FINISHED GRADE <br />C <br />- CONDUIT <br />CW <br />- COOL WHITE <br />CU <br />- CONDENSING UNIT <br />CKT <br />- CIRCUIT <br />DACP <br />- DOOR ALARM CONTROL PANEL <br />DN <br />- DOWN <br />EF <br />- EXHAUST FAN <br />EG <br />- EQUIPMENT GROUND <br />ENCL <br />-ENCLOSURE <br />EWC <br />- ELECTRIC WATER COOLER <br />EWH <br />- ELECTRIC WATER HEATER <br />ETR <br />- EXISTING TO REMAIN <br />PNL <br />-PANEL <br />EOP <br />- EDGE OF PAVEMENT <br />EXP <br />- EXPLOSION PROOF <br />FCU <br />- FAN COIL UNIT <br />FHP <br />- FRACTIONAL HORSE POWER <br />FLA <br />- FULL LOAD AMPERES <br />G <br />-GROUND <br />GFI <br />- GROUND FAULT INTERRUPTER <br />HID <br />- HIGH INTENSITY DISCHARGE <br />HORIZ <br />- HORIZONTAL <br />IG <br />- ISOLATED GROUND <br />LW <br />- LIGHT WHITE <br />HP <br />- HORSEPOWER / HEAT PUMP <br />HVAC <br />- HEATING, VENTILATING, AIR CONDITIONING <br />JB <br />- JUNCTION BOX <br />LRA <br />- LOCKED ROTOR AMPERES <br />MCB <br />- MAIN CIRCUIT BREAKER <br />MLO <br />- MAIN LUGS ONLY <br />N <br />-NEUTRAL <br />NL <br />- NIGHT LIGHT <br />OB <br />- OUTLET BOX <br />PB <br />- PULL BOX, PUSHBUTTON <br />PS <br />- PAY STATION <br />RECEPT <br />-RECEPTACLE <br />SF <br />- SUPPLY FAN <br />SPEC <br />- SPECIFICATIONS <br />SPD <br />- SURGE PROTECTION DEVICE <br />SWECS <br />- SMOKE WARNING EMERGENCY CALL SYSTEM <br />TL <br />- TWISTLOCK <br />TTB <br />- TELEPHONE TERMINAL BOARD <br />TVTB <br />- TELEVISION TERMINAL BOARD <br />VERT <br />- VERTICAL <br />WM <br />- WATT MISER <br />WP <br />- WEATHERPROOF <br />WW <br />- WARM WHITE <br />XFMR <br />- TRANSFORMER <br />GENERAL NOTES <br />1. ALL WORK IS TO COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE AND THE 7TH EDITION, <br />2020 FLORIDA BUILDING CODE, AND ALL LOCAL CODES OR REGULATIONS THAT MAY APPLY TO <br />THE PROJECT, <br />2. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MAKING A SITE VISIT IN ORDER TO <br />IDENTIFY EXISTING CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />THAT ANY ELECTRICAL SYSTEMS TO REMAIN ARE CODE COMPLIANT. <br />3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY POWER AND <br />TEMPORARY LIGHTING AS REQUIRED FOR THE DURATION OF THE PROJECT. <br />4. THE ELECTRICAL CONTRACTOR IS REQUIRED TO PROVIDE A WORKMANSHIP WARRANTY OVER <br />THE PERIOD OF ONE YEAR AFTER PROJECT COMPLETION THAT IS SUFFICIENT TO COMPLY WITH <br />THE PROJECT CONTRACT. <br />5. THE ELECTRICAL CONTRACTOR IS TO PROVIDE A COMPLETE SET OF MARKED UP ELECTRICAL <br />"AS BUILT" DRAWINGS TO THE GENERAL CONTRACTOR UPON COMPLETION OF THE PROJECT. <br />6. THE ELECTRICAL CONTRACTOR IS TO PROVIDE AN OPERATION AND MAINTENANCE MANUAL <br />FOR ALL EQUIPMENT REQUIRING MAINTENANCE ASSOCIATED WITH THE PROJECT. <br />7. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL WORK WITH OTHER <br />TRADES IN ORDER TO NOT INTERFERE WITH THE OVERALL PROJECT SCHEDULE, <br />8. IF A DISCREPANCY IS FOUND BETWEEN THE ELECTRICAL PLANS AND THE SPECIFICATIONS, THE <br />MOST STRINGENT REQUIREMENT SHALL GOVERN UNLESS WRITTEN APPROVAL IS GRANTED <br />FROM THE ARCHITECT OR ENGINEER. <br />9. ALL BREAKER, DISCONNECT AND WIRE SIZING MUST BE CONFIRMED BY THE ELECTRICAL <br />CONTRACTOR PRIOR TO ROUGHIN. <br />SUBMITTALS AND SHOP DRAWINGS <br />1. PRIOR TO PROCUREMENT, THE CONTRACTOR IS REQUIRED TO PROVIDE SUBMITTALS AND <br />SHOP DRAWINGS TO THE GENERAL CONTRACTOR, ENGINEER, AND ARCHITECT FOR <br />APPROVALS. <br />2. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO ENSURE THE SUBMITTED <br />PRODUCTS WILL FORM A COMPLETE, FUNCTIONAL, AND CODE COMPLIANT ELECTRICAL <br />SYSTEM. <br />WIRING AND RACEWAYS <br />1. NO WIRING IS TO BE SMALLER THAN #12 AWG UNLESS OTHERWISE NOTED. <br />2. EACH BRANCH CIRCUIT FOR LIGHTING AND RECEPTACLES SHALL BE INSTALLED WITH <br />DEDICATED NEUTRAL. ALL OTHER CIRCUITS SHALL BE INSTALLED WITH DEDICATED NEUTRAL <br />UNLESS EQUIPMENT DOES NOT REQUIRE A NEUTRAL CONNECTION. <br />3. THE CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS COMBINED SHALL BE SIZED FOR A <br />MAXIMUM AT 5% VOLTAGE DROP TOTAL PER FBC C405.5.3, <br />4. TYPE MC CABLING IS ACCEPTABLE UNLESS PROHIBITED BY THE SPECIFICATIONS OF THE <br />PROJECT, OR THE NATIONAL ELECTRIC CODE DUE TO THE OCCUPANCY TYPE OF THE PROJECT. <br />5. NONMETALLIC CABLING (ROMEX) SHALL NOT BE USED. <br />6. ALL WIRING IS TO BE SIZED ACCORDING TO THE NEC. <br />7. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO UPSIZE ALL CONDUIT AND <br />WIRING WHEN REQUIRED DUE TO VOLTAGE DROP POSED BY ONSITE CONDITIONS. <br />8. PROVIDE COMPLETE RACEWAYS FOR ALL SYSTEMS AS REQUIRED BY THE NEC AND LOCAL <br />CODES. TYPE PVC, EMT, AND RMC ARE PERMITTED AS REQUIRED BY THE LOCAL CODE. <br />9. A GROUND CONDUCTOR IS TO BE SUPPLIED IN ALL RACEWAYS. SIZE THE GROUND <br />CONDUCTOR PER THE NEC, OR AS SHOWN ON THE PLAN, WHICHEVER IS LARGER. <br />10. RACEWAYS ARE TO BE CONCEALED AND EQUIPMENT IS TO BE FLUSH MOUNTED, UNLESS <br />OTHERWISE NOTED, OR WHEN ONSITE CONDITIONS MAKE CONCEALING OR FLUSH MOUNTING <br />IMPOSSIBLE. <br />11. WHEN A RACEWAY PENETRATES A FIRE WALL OR FLOOR, THE RACEWAY IS TO BE SEALED IN A <br />MANNER WHICH WILL MAINTAIN THE RATING OF THE WALL OR FLOOR. <br />12. MINIMUM CONDUIT SIZE IS TO BE 3/4 INCH, UNLESS OTHERWISE NOTED. <br />13. FLEXIBLE CONDUIT IS ALLOWABLE IN LENGTHS OF 6' OR LESS, WHEN IT IS MORE PRACTICAL TO <br />MAKE CONNECTIONS TO EQUIPMENT, <br />14. SEALTITE FLEXIBLE CONDUIT IS TO BE USED IN OUTDOOR APPLICATIONS. <br />15. THE RACEWAY SYSTEM AS A WHOLE IS REQUIRED TO COMPLY WITH ALL NEC AND LOCAL <br />CODE REQUIREMENTS. <br />GROUNDING <br />1. THE ELECTRICAL SYSTEM IS TO BE GROUNDED IN ITS ENTIRETY PER THE NEC. <br />2. THE TELEPHONE / NETWORK BOARD IS TO HAVE NO. 6 AWG GROUND WIRE TO THE MAIN <br />SERVICE GROUND. <br />3. ALL METALLIC EQUIPMENT INCLUDING RACEWAYS, PANELBOARDS, DISCONNECTS, BOXES, <br />ARE TO BE CONNECTED TO THE GROUNDING SYSTEM PER NEC REQUIREMENTS. <br />4. THE SERVICE GROUND IS TO BE SIZED ACCORDING TO NEC REQUIREMENTS AND IS TO BE <br />CONNECTED TO BUILDING STEEL, COLD WATER PIPING, CONCRETE ENCASED STEEL, AND GAS <br />PIPING IF REQUIRED. <br />DEVICES <br />1. LIGHT SWITCHES ARE TO BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO THE TOP OF <br />THE DEVICE, UNLESS OTHERWISE NOTED, <br />2. RECEPTACLES ARE TO BE MOUNTED 18 INCHES ABOVE FINISHED FLOOR TO THE CENTERLINE <br />OF THE DEVICE, UNLESS OTHERWISE NOTED. <br />3. THE COLOR AND STYLE OF OUTLETS AND SWITCHES ARE TO BE DETERMINED BY THE CLIENT, <br />4. RECEPTACLES ARE TO BE GFCI TYPE WHERE NOTED. <br />5. PROVIDE TAMPER -RESISTANT RECEPTACLES IN OCCUPANCIES WHERE REQUIRED BY NEC 2017, <br />406.12. <br />6. RECEPTACLES AND SWITCHES ARE TO BE FLUSH MOUNTED UNLESS OTHERWISE NOTED. <br />7. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO ENSURE COMPATIBILITY OF <br />SPECIAL RECEPTACLES WITH THE EQUIPMENT THEY ARE INTENDED TO SERVE. <br />8. ALL EXTERIOR RECEPTACLES AND RECEPTACLES SUBJECT TO MOISTURE MUST BE OF GFCI <br />TYPE REGARDLESS OF THE TYPE SHOWN ON THE ELECTRICAL PLANS. <br />9. ALL EXTERIOR RECEPTACLES AND SWITCHES ARE REQUIRED TO BE INSTALLED WITH <br />WEATHERPROOF "IN USE" TYPE COVERS. <br />10. DEVICES ARE SHOWN ON THE ELECTRICAL PLANS FOR A REFERENCE LOCATION ONLY. <br />COORDINATE EXACT LOCATION WITH ARCHITECTURAL PLANS AND OTHER TRADES. NOTE ANY <br />CHANGES ON THE "AS BUILT" SET OF ELECTRICAL PLANS. <br />SWITCHGEAR21 * ''U° ' <br />L PANELBOARDS AND LOAD CENTERS ARE TO BE SQUARE D OR APPROVED EQUAL. <br />2. PANELBOARDS AND LOAD CENTERS ARE TO BE PROVIDED WITH TRANSIENT VOLTAGE SURGE <br />SUPPRESSION AS DESCRIBED IN THE ELECTRICAL PLANS. <br />3. DISCONNECTS ARE TO BE HEAVY DUTY TYPE AND ARE TO BE FUSED WHERE THE EQUIPMENT IS <br />NOT SUPPLIED BY THE APPROPRIATE BREAKER. <br />4. ALL NEW BREAKERS ADDED TO EXISTING PANELS ARE TO MATCH THE EXISTING PANEL <br />MANUFACTURER AND AIC RATING OF THE EXISTING BREAKERS, <br />5. THE LOCATIONS OF ALL SWITCHGEAR, PANELS, DISCONNECTS, MCC'S, ETC. IS APPROXIMATE. <br />CONSULT OWNER PRIOR TO ROUGH IN OF EQUIPMENT. <br />6. PROVIDE TYPED PANEL SCHEDULES/DIRECTORIES FOR ALL PANELS UPON COMPLETION OF THE <br />PROJECT. ENSURE THAT THE SCHEDULES PROVIDED REFLECT THE "AS BUILT" CONDITION AND <br />ARE NOT SIMPLY COPIES OF THE PANEL SCHEDULES FROM THESE PLANS. IF AN EXISTING <br />PANEL IS MODIFIED, IT IS ACCEPTABLE TO ADD THE MODIFICATION TO THE EXISTING <br />SCHEDULE IN THE MANNER THE EXISTING SCHEDULE WAS ORIGINALLY CREATED. <br />7. PROVIDE ENGRAVED PLASTIC LAMINATE NAME TAGS ON THE FRONT OF ALL PANELS, <br />DISCONNECTS, TRANSFORMERS AND OTHER SWITCHGEAR. LABEL THE EQUIPMENT TO MATCH <br />THE AS BUILT DRAWINGS TO ENSURE MAINTENANCE PERSONNEL ARE PROVIDED THE <br />INFORMATION THEY NEED TO QUICKLY IDENTIFY THE ELECTRICAL SYSTEM. <br />8. PROVIDE ALL OTHER IDENTIFICATION AS REQUIRED PER ANSI, NEC, AND ANY OTHER <br />APPLICABLE STANDARDS / SPECIFICATIONS. <br />9. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY ALL NEC CLEARANCE <br />REQUIREMENTS ARE MET BEFORE THE ROUGH -IN OF ANY EQUIPMENT. THE LAYOUT OF <br />SWITCHGEAR AND OTHER EQUIPMENT ON THE PLANS IS DIAGRAMMATICAL ONLY. <br />10, IT IS THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO ENSURE THE METERING <br />SCHEME SHOWN ON THESE PLANS CONFORM TO THE SPECIFICATIONS OF THE LOCAL UTILITY <br />COMPANY GOVERNING THIS PROJECT. THE LOCAL UTILITY'S METERING STANDARDS BOOK <br />NEEDS TO BE RESEARCHED BY THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING OF <br />MATERIALS. <br />11. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE AVAILABLE FAULT <br />CURRENT CALCULATIONS ON THIS PLAN SET. CALCULATIONS WITHIN THIS PLAN SET ARE <br />BASED ON TRANSFORMER, AND CONDUCTOR INFORMATION THAT MAY OR MAY NOT REFLECT <br />THE ACTUAL INSTALLATION ON THE PROJECT SITE. ANY DESCREPANCIES INCLUDING THE <br />AVAILABLE FAULT CURRENT AT UTILITY TRANSFORMERS MUST BE BROUGHT TO THE <br />ENGINEER'S ATTENTION PRIOR TO ORDERING ANY EQUIPMENT. <br />T T!'-iLTTTAT("_ <br />1. CONNECT ALL EXIT SIGNS, EGRESS FIXTURES, AND NIGHT LIGHTS ON THE UNSWITCHED LEG <br />OF A LOCAL LIGHTING CIRCUIT. <br />2. MINIMUM EMERGENCY ILLUMINATION OF I FOOTCANDLE AT FLOOR LEVEL ALONG THE PATH <br />OF EGRESS FOR 90 MINUTES IS REQUIRED. EMERGENCY LIGHTING FIXTURES SHALL BE <br />ARRANGED BY THE CONTRACTOR TO ACCOMPLISH THIS REQUIREMENT. <br />3. REFER TO THE ARCHITECTURAL CEILING PLAN FOR EXACT FIXTURE LOCATIONS. <br />4. MULTIPLE FIXTURES MAY HAVE OPTIONS FOR MOUNTING IN GRID, OR DRYWALL CEILINGS. IT <br />IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THE PROPER MOUNTING HARDWARE <br />AND TRIM PIECES ARE ORDERED BASED ON THE CEILING TYPES SHOWN IN THE <br />ARCHITECTURAL PLANS. <br />5. ALL FIXTURES AND CONTROLS ARE FURNISHED AND INSTALLED BY THE ELECTRICAL <br />CONTRACTOR, UNLESS OTHERWISE NOTED. <br />PROFESSIONAL STATEMENT <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND <br />SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING <br />CODES AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINED <br />BY THE LOCAL AUTHORITY IN ACCORDANCE WITH FLORIDA STATUTES. <br />0: F <br />01 <br />�l ON4L 4\_ <br />CORY GLASS <br />STATE OF FLORIDA REGISTERED <br />PE #80467 <br />SIGNATURE <br />v <br />� M <br />00 <br />+, <br />n <br />Z <br />4 <br />moo°' <br />+� <br />Iwo <br />O N <br />O M <br />X <br />tai <br />W.c_cJ``o <br />t ■ ■ Q) Q <br />Yr <br />Oco <br />W <br />O <br />o0 <br />� <br />n <br />N � <br />110 <br />m <br />O) <br />� <br />w <br />�WU <br />(n <br />w <br />W <br />Z <br />W•��0Q <br />j�ic- <br />W Q <br />O <br />Z <br />� � <br />� <br />z <br />- � <br />n <br />N <br />Z-0 <br />z <br />v <br />N <br />I <br />Q <br />C) =3 <br />W <br />rn <br />Z <br />O <br />V) <br />5 <br />w <br />x <br />N n * Nt0 � <br />I- <br />fn <br />Q <br />W <br />( <br />N <br />z <br />0 Q <br />z <br />- <br />Q <br />ir <br />V J <br />af J <br />� <br />0 <br />3:�`' <br />Ll:� <br />Z J <br />0 <br />O 0 2 <br />W <br />0O <br />~Lo NX <br />0 <br />W <br />J = LLJ <br />N <br />z <br />,L. <br />o <br />C0 <br />G <br />O <br />O F- <br />NU <br />Z <br />O <br />F- <br />U <br />W <br />0 <br />ELECTRICAL DESIGN <br />3 <br />Y N <br />ri <br />w <br />o <br />2150 Range Road <br />�� <br />Z <br />z <br />O <br />Clearwater, FL 33765 <br />rw <br />0 <br />w <br />(727) 243-7043 1 www.GCElectricalDesign.com <br />W <br />Florida Board of Professional Engineers #33905 <br />z <br />0 <br />Z <br />W <br />w <br />a a <br />o <br />v <br />W <br />= <br />oflo--.)(n <br />V) <br />