111111111 CABINETS & COUNTERTOPS GYPSUM BOARD GENERAL NOTES <br />01 BATHROOM VANITY CABINETS SHALL BE 21" DEEP WITH 22" TOPS, UNO. REFER TO INTERIOR ELEVATIONS <br />FOR HEIGHTS <br />02 KITCHEN CABINETS SHALL BE 24" DEEP WITH 25" TOPS, UNO. REFER TO INT. ELEVATIONS FOR HEIGHTS <br />03 G.C. TO FIELD VERIFY FINISH TO FINISH DIMENSIONS PRIOR TO FABRICATION OF CABINETS. <br />04 FINISH ALL EXPOSED CABINET ENDS. ALL EXPOSED FINISHED ENDS SHALL MATCH THE EXTERIOR COLOR <br />OF THE ADJACENT CABINETS. <br />05 UNIT COUNTERTOPS: <br />A. LAVATORIES: POST FORMED P.L. WITH INTEGRAL BACKSPLASH <br />B. UNIT Al, B1, B3, C1, C3 KITCHEN: POST FORMED P.L. WITH INTEGRAL BACKSPLASH. RAISED P.L. BARTOP <br />TO BE SQUARE EDGE <br />C. UNIT A2, B2, B4, C2 KITCHEN: DUE TO STEPS IN THE COUNTERTOP, PROVIDE POST FORMED P.L. <br />COUNTERTOP WITH SEPARATE APPLIED BACKSPLASH (ROUND FRONT EDGE ONLY). APPLIED P.L. <br />BACKSPLASH 4"/6" PER INTERIOR ELEVATIONS. RAISED P.L. BARTOP TO BE SQUARE EDGE. <br />D. CLUBHOUSE PER CLUBHOUSE DRAWINGS <br />APPLIANCES <br />01 ENERGY STAR RATING REQUIRED FOR ALL REFRIGERATORS, DISHWASHERS AND WASHING MACHINES <br />PROVIDED. <br />n <br />m <br />0 <br />0 <br />N <br />co <br />0 <br />m0 <br />a <br />I <br />M <br />0 <br />0 <br />U) <br />co <br />0 <br />a <br />N, <br />01 ALL INTERIOR NON -RATED WALL CONSTRUCTION TO HAVE MIN.1/2" REGULAR GYPSUM BOARD, UNO <br />02 ALL INTERIOR FRAMED FIRE -RATED WALL CONSTRUCTION TO HAVE 5/8" FIRE -RATED GYPSUM BOARD, UNO <br />03 GYPSUM BOARD INSTALLATION SHALL BE IN CONFORMANCE WITH THE GYPSUM ASSOCIATIONS <br />RECOMMENDED PRACTICES FOR THICKNESS, ATTACHMENT, TAPING, FINISHING AND STUD SPACING. <br />04 GYPSUM BOARD USED IN A FIRE RATED ASSEMBLY SHALL CONFORM EXACTLY TO THE REQUIREMENTS OF <br />THE ASSEMBLY LISTED. <br />05 PROVIDE WATER RESISTANT TILE BACKER BOARD BEHIND ALL CERAMIC TILE IN TUBS AND SHOWERS. SEE <br />DETAILS. <br />■ WINDOWS & DOORS <br />01 ALL EXTERIOR WINDOWS AND DOORS SHALL BE SEALED AND WEATHER STRIPPED. WINDOW UNITS SHALL <br />DISPLAY LABELS SHOWING COMPLIANCE WITH THE STATE ENERGY CODE. <br />02 HINGES ON EXTERIOR OUT -SWINGING DOORS SHALL HAVE NON -REMOVABLE PINS AND NON -EXPOSED <br />SCREWS. <br />03 GLASS AT EXTERIOR DOORS SHALL COMPLY WITH ANSI 297.1. <br />04 VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATING <br />DEVICE OF LOOSE AND SWING DOORS SHALL COMPLY WITH THE ANSI 297.1. <br />05 FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS. UFAS UNIT <br />ENTRY DOORS SHALL HAVE AN ADDITIONAL PEEPHOLE @ 4'-10" AFF. <br />06 INDIVIDUAL GLAZED AREAS, INCLUDING GLASS MIRRORS, IN HAZARDOUS LOCATIONS AS DEFINED BY THE <br />BUILDING CODE SHALL HAVE SAFETY GLAZING MATERIAL IN COMPLIANCE WITH THE BUILDING CODE. <br />07 HARDWARE: ALL EQUIPMENT AND HARDWARE, WHERE APPLICABLE, SHALL MEET ALL FEDERAL, STATE, <br />AND LOCAL GUIDELINES FOR HANDICAP ACCESSIBILITY. FORCE REQUIRED TO OPERATE ALL EQUIPMENT <br />SHALL BE NO GREATER THAN 5 LBS. <br />08 EMERGENCY ESCAPE AND RESCUE OPENING: EACH SLEEPING ROOM SHALL CONTAIN AT LEAST ONE <br />OPENING WINDOW OR DOOR THAT MUST BE OPERABLE FROM INSIDE WITHOUT THE USE OF TOOLS. THE <br />OPENING MUST BE ACCESSIBLE TO FIRE DEPARTMENT RESCUE APPARATUS OR BE WITHIN 20 FT. OF <br />GRADE. MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES AND MINIMUM NET CLEAR OPENING <br />HEIGHT SHALL BE 24 INCHES. MINIMUM NET CLEAR OPENING AREA SHALL BE 5.7 SQ. FT. MINIMUM SILL <br />HEIGHT SHALL BE AT LEAST 24" AND MAXIMUM SILL HEIGHT SHALL BE 44 INCHES ABOVE FINISHED FLOOR. <br />09 ALL WINDOWS SHALL BEAR THE APPROVED LABEL WITH CORRECT PRESSURES LISTED, AND BEAR A WDMA <br />OR OTHER APPROVED LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND <br />APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENT OF <br />AAMA/WOMA 101/I.S.2/NAFS. <br />10 ENERGY STAR RATING IS REQUIRED FOR ALL WINDOWS AND GLASS DOORS IN EACH UNIT. <br />01 CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />PROCEEDING WITH THE WORK. <br />02 DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND <br />IDENTIFICATION OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS <br />REGARDING EXACT REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF <br />WORK, AND CLASSIFICATIONS. <br />03 ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A <br />REVIEW OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />04 DO NOT SCALE DRAWINGS. USE ONLY PRINTED DIMENSIONS. <br />05 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING <br />TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO <br />PROCEEDING WITH THE PROJECT. <br />06 THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION <br />MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS <br />AND PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />07 ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT <br />THE NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE <br />NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY <br />THE OWNER AND OTHER AUTHORITIES. <br />08 DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, <br />OR ROUGH OPENING AT STUD WALLS. <br />09 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND <br />DATA TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY <br />PRODUCT SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT <br />ORIGINALLY SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE <br />NEW PRODUCT DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED <br />PRODUCT APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. <br />10 ANY ERRORS, OMISSIONS OR INCONSISTENCIES DISCOVERED IN THE DOCUMENTS, OR ANY VARIATION OR <br />AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS AND/OR <br />REQUIREMENTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IF A DISCREPANCY IS FOUND <br />IN THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING. <br />11 THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING AN IDENTIFYING SYMBOL ON <br />STRUCTURES CONSTRUCTED WITH A LIGHT -FRAME TRUSS COMPONENT IN A MANNER SUFFICIENT TO <br />COMPLY WITH THE STATE OF FLORIDA FIRE MARSHAL'S OFFICE IN ACCORDANCE WITH FLORIDA STATUTE <br />633.027, PER THE REQUIREMENTS OF THE FLORIDA ADMINISTRATIVE CODE RULE 69A-60.0081, AND AS <br />DETERMINED BY THE AUTHORITY HAVING JURISDICTION. CONTRACTOR TO VERIFY FINAL LOCATION WITH I <br />AHJ. <br />0 FIRE EXTINGUISHER SITE WORK <br />01 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH BUILDING AS REQUIRED AND SPECIFIED IN <br />NFPA 10, CHAPTER 3. PORTABLE FIRE EXTINGUISHER SHALL BE INSTALLED IN LOCATIONS INDICATED ON <br />THE DRAWINGS OR AT A MINIMUM OF (1) FIRE EXTINGUISHER PER BREEZEWAY, CORRIDOR, OR OVERALL <br />GENERAL BUILDING AREA. FIRE EXTINGUISHERS SHALL BE LOCATED (1) PER FLOOR, WITH A MAXIMUM <br />TRAVEL DISTANCE OF 75 FEET TO THE EXTINGUISHER OR AS REQUIRED BY LOCAL AUTHORITIES HAVING <br />JURISDICTION. EACH EXTINGUISHER SHOULD HAVE A MINIMUM RATING OF 2A:10-B:C, LINO <br />02 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH INDIVIDUAL RESIDENTIAL DWELLING UNIT AS <br />RECOMMENDED BY NFPA 10, ANNEX F AND INSTALLED AS INDICATED ON THE DRAWINGS OR AT A MINIMUM <br />OF (1) FIRE EXTINGUISHER PER FLOOR LEVEL OF A LIVING UNIT WITH A MAXIMUM TRAVEL DISTANCE OF 40 <br />FEET TO THE EXTINGUISHER OR AS REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. EACH <br />EXTINGUISHER SHOULD HAVE A MINIMUM RATING OF 2A:10-B:C, UNO <br />PAINT <br />01 SEE INTERIOR FINISH SCHEDULE FOR PAINTING. REFER TO INTERIOR DESIGN DRAWINGS FOR PAINT SPEC. <br />AND COLORS. <br />02 ALL EXTERIOR VENTS AND EQUIPMENT THAT ARE VISIBLE ON EXTERIOR OF BUILDING SHALL BE PAINTED A <br />COLOR TO MATCH THE ADJACENT SURFACE, UNO <br />03 ALL COLOR TRANSITIONS SHALL BE ON THE INSIDE CORNERS, UNLESS OTHERWISE SPECIFIED IN COLOR <br />ELEVATIONS. <br />04 CONTACT THE OWNER OR ARCHITECT IF THERE ARE ANY QUESTIONS PRIOR TO PAINTING <br />05 PROVIDE LOW VOC PAINT IN ALL UNITS & INTERIOR COMMON AREAS <br />01 SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR <br />ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. <br />FOUNDATIONS AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED <br />NON -EXPANSIVE SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING <br />LOADS, AND COMPARE WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE <br />OBSERVATIONS SHOW THAT FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE <br />CONTACTED IMMEDIATELY FOR REVISED DESIGNS. <br />02 THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: <br />SITE UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR <br />REQUIRED AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, <br />ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY <br />WITH ALL UTILITY COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY <br />COMPANIES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY <br />COMPANY. <br />03 REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED <br />GRADES, FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. <br />04 REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT <br />FIXTURES, ETC. <br />05 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING <br />SHALL NOT BE LESS THAN 6 INCHES, LINO <br />TERMITE PROTECTION <br />■ FLOOR COVERING 01 ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION PROTECTION AGAINST SUBTERRANEAN TERMITES <br />01 SEE INTERIOR FINISH SCHEDULE FOR FLOOR FINISHES. APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-0" OF THE PRIMARY STRUCTURE SIDE <br />WALLS AS REQUIRED BY THE APPLICABLE BUILDING CODE. <br />02 ALL INTERIOR FLOOR FINISHES SHALL NOT BE LESS THAN CLASS II PER NFPA 253. <br />03 PROVIDE CARPET & RUG INSTITUTE GREEN LABEL CERITIFIED CARPET & PAD FOR ALL CARPETING <br />04 STC AND IIC SOUND RATINGS SHALL BE MAINTAINED BETWEEN THE FLOOR / CEILING OF DIFFERENT <br />TENANTS TO MEET THE CODE REQUIREMENTS IN FBC SECTION 1207. SOUND MAT SHALL BE PROVIDED <br />UNDER FINISHED FLOORING AS NECESSARY TO MEET THESE REQUIREMENTS. <br />SHELVING <br />01 ALL SHELVING TO BE VINYL COATED WIRE SHELVING, UNO <br />02 PROVIDE (1)12" DEEP SHELF W/ HANGING BAR AT BEDROOM CLOSETS, (5)16" DEEP SHELVES IN PANTRY <br />AND LINEN, AND (1)12" DEEP SHELF OVER WASHER AND DRYER, UNO <br />02 THE CONTRACTOR IS RESPONSIBLE TO PROVIDE AND INSTALL TERMITE PROTECTION AS REQUIRED BY ALL <br />APPLICABLE CODES AND PER MANUFACTURER'S RECOMMENDATIONS. <br />03 A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE <br />WATER HEATER OR ELECTRICAL PANEL. <br />04 CONDENSATE DRAINS, WATER HEATER DRAINS, AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST <br />1'-0" AWAY FROM BUILDING SIDE WALLS. <br />a <br />FORUME <br />Q <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />0 <br />0 745 orienta avenue, suite 1121 <br />altamonte springs, tl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />M0002731 <br />www.forumarchitecture.com <br />i <br />0 <br />Fort King <br />Colony <br />Apartments <br />City of Zephyrhills, FL <br />T DISTRIBUTIONS: <br />08/18/10.. Bid 8 Permit Set <br />EDITED BY: JT <br />PROJECT NO. 10-2651 <br />z <br />General Notes <br />I <br />W <br />z <br />W <br />w <br />U <br />W <br />F <br />I <br />U <br />0 <br />A1.03 <br />a <br />0 <br />