Laserfiche WebLink
POST TENSION SLAB (OPTION) POST TENSION SLAB (CONT.) JUGENERAL <br />N <br />0 <br />0 <br />N <br />0 <br />a <br />0 <br />a <br />0 <br />0 <br />M <br />0 <br />SS <br />C <br />0 <br />U <br />3 <br />-a <br />0 <br />a <br />co <br />N <br />n • <br />01 CONTRACTOR HAS THE OPTION OF PROVIDING A POST -TENSION SLAB SYSTEM IN LIEU OF THE MONOLITHIC 32 ALL FIELD ELONGATIONS SHOULD BE SUBMITTED TO THE ENGINEER OF RECORD PRIOR TO CUTTING THE <br />SLAB SYSTEM SHOWN IN THESE DRAWINGS. IF THE CONTRACTOR CHOOSES TO TAKE THIS OPTION, THE TENDON TAILS. <br />CONTRACTOR MUST SUBMIT COMPLETE POST -TENSION DESIGN DRAWINGS WITH DETAILS, SIGNED AND <br />SEALED BY AN ENGINEER REGISTER IN THE STATE WHERE THE PROJECT IS LOCATED, TO THE ARCHITECT AND 33 STRAND SHALL BE COATED WITH A PERMANENT RUST PREVENTATIVE COATING AND ENCLOSED WITHIN AN <br />STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. EXTRUDED PLASTIC SHEATHING. FIELD TAPE ANY TEARS IN THE SHEATHING AND UP TO THE STRESSING <br />ANCHORAGE PRIOR TO CONCRETE PLACEMENT. <br />02 PROVIDE ALL NECESSARY BAR SUPPORT AND TIES IN ACCORDANCE WITH THE LATEST A.C.I. DETAILING <br />MANUAL. <br />03 PROVIDE 3/4" COVER TOP AND BOTTOM FOR POST -TENSION CABLE AND 3/4" COVER FOR MILD STEEL <br />REINFORCEMENT. <br />04 ADD HOOK LENGTHS TO BARS SHOWN THUS: L <br />05 FREE MOVEMENT OF THE BEAMS IN THE FORM MUST BE INSURED DURING PRE -STRESSING <br />06 REINFORCING LENGTH MAY VARY BY A MAXIMUM OF 3 INCHES TO ELIMINATE WASTE. <br />07 HEIGHTS OF STRANDS ARE MEASURED FROM BOTTOM OF THE SLAB TO THE CENTERLINE OF STRAND, OR <br />CENTROID OF STRAND GROUP. <br />08 STRANDS MAY BE STRESSED WHEN CONCRETE ACHIEVES 75% OF THE REQUIRED 28 DAY STRENGTH. <br />09 THE POST -TENSION CONTRACTOR SHALL PREPARE SHOP DRAWINGS AND STRESSING CALCULATIONS, BOTH <br />CERTIFIED BY A PROFESSIONAL ENGINEER IN THE STATE OF THE PROJECT TO BE SUBMITTED TO THE <br />ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL, PRIOR TO CONSTRUCTION. NO <br />PLACEMENT OF TENDONS SHALL COMMENCE WITHOUT APPROVED DRAWINGS. REVIEW OF SHOP DRAWINGS <br />IS FOR GENERAL DETAIL AND ARRANGEMENT ONLY. CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR <br />DIMENSIONS AND FIT. THEIR APPROVAL BY THE STRUCTURAL ENGINEER AND ARCHITECT IS NOT TO BE <br />CONSTRUED AS A WAIVER OF CONSTRUCTION CONTRACT REQUIREMENTS OR RESPONSIBILITIES, UNLESS THE <br />CONTRACTOR HAS REQUESTED A DEVIATION IN WRITING. <br />10 SHOP DRAWINGS ARE TO INDICATE STRAND SPACING, PROFILE, CHAIR HEIGHTS AND SPACINGS, STRESSING <br />FORCES AND ANTICIPATED ELONGATION. <br />11 POST -TENSION CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER AND ARCHITECT THREE (3) <br />COPIES OF ELONGATIONS AND FORCES BOTH CALCULATED AND MEASURED, IMMEDIATELY AFTER WORK IS <br />COMPLETE. <br />12 THE FORCES SHOWN ON ANY DRAWING SHALL BE THE EFFECTIVE FORCES AT ANY POINT ALONG THE STRAND <br />LINE AFTER ALL LOSSES HAVE OCCURRED. <br />13 ALL FORM WORK SHORING MUST BE LEFT IN PLACE UNTIL STRESSING IS COMPLETED. <br />14 A MINIMUM OF TWO STRANDS SHALL PASS THROUGH EACH COLUMN OR VERTICAL SUPPORT. <br />15 ALL POCKETS REQUIRED FOR ANCHORAGES SHALL BE ADEQUATELY REINFORCED NOT TO DECREASE THE <br />STRENGTH OF THE STRUCTURE. ALL POCKETS SHALL BE WATERPROOFED TO ELIMINATE WATER LEAKAGE <br />THROUGH THE POCKET. <br />16 TENDONS SHALL BE DRAPED TO A DOUBLE PARABOLIC PROFILE BETWEEN SUPPORTS AND SHALL CONFORM <br />TO THE CONTROL POINTS SHOWN IN THE TENDON OR GROUP OF TENDONS. LOW POINTS ARE AT MID SPAN <br />UNLESS OTHERWISE NOTED. ADEQUATE SUPPORT BARS AND CHAIRS SHALL BE FURNISHED TO ADEQUATELY <br />HOLD THE TENDONS DURING THE CONCRETE PLACEMENT. <br />17 IN ACCORDANCE WITH A.C.I., ALL CONCRETE SHALL BE PRE -STRESSED TO PROVIDE A MINIMUM AVERAGE <br />COMPRESSIVE STRESS OF 100 PSI ON GROSS CONCRETE AREA, USING EFFECTIVE PRE -STRESS AFTER <br />LOSSES. CONTRACTOR SHALL PROVIDE MINIMUM FORCE IN ALL CONCRETE WHETHER OR NOT SPECIFICALLY <br />IDENTIFIED ON DRAWINGS. <br />18 ALL DESIGN, MATERIAL, AND WORKMANSHIP FOR THE POST -TENSIONED SLAB ON GROUND SHALL CONFORM <br />TO: "DESIGN AND CONSTRUCTION OF POST -TENSIONED SLABS -ON -GROUND" PUBLISHED BY THE <br />P80ST-TENSIONING INSTITUTE. <br />19 THIS SLAB -ON -GROUND DESIGN IS IN ACCORDANCE WITH ACCEPTABLE ENGINEERING PRACTICES FOR THE <br />PROJECT SPECIFICALLY STATED ON THESE DRAWINGS. THESE DRAWINGS MAY NOT BE USED FOR ANY OTHER <br />LOCATION. <br />20 THE SLAB -ON -GROUND DESIGN SHALL BE DESIGNED IN ACCORDANCE WITH THE GEOTECHNICAL <br />INVESTIGATION PERFORMED BY: FAULKNER ENGINEERING SERVICES DATED SEPTEMBER 24, 2007 <br />1. BEARING PRESSURE = 2,000 PSF <br />2. SUBGRADE MODULUS =150 PCI <br />21 THE DESIGN SHALL BE ONLY APPLICABLE IF THE SUPPORTING SOILS ARE PREPARED IN ACCORDANCE WITH <br />THE RECOMMENDATIONS IN THE GEOTECHNICAL REPORT. <br />22 THIS SLAB -ON -GROUND SHALL BE DESIGNED TO CONTROL TEMPERATURE AND SHRINKAGE CRACKS. INITIALLY, <br />IT MAY SUSTAIN SHRINKAGE AND TEMPERATURE CRACKS DURING NORMAL CONCRETE CURING. <br />23 FINAL GRADE AND A REASONABLY UNIFORM MOISTURE CONTENT SHALL BE MAINTAINED FOR THE LIFE OF THE <br />STRUCTURE, INCLUDING DURING CONSTRUCTION. <br />24 SUBGRADE PREPARATION SHALL BE AS DEFINED AS NOTED IN THE SOIL REPORT. <br />25 A CONTINUOUS 6 MIL POLYETHELENE SHEET SHALL BE PROVIDED BELOW THE SLAB -ON -GROUND (USE 12" <br />LAPS). <br />26 ALL DIMENSIONS, BRICKLEDGES, DROPS, OFFSETS, OPENINGS, INSERTS, ETC., SHALL BE FIELD VERIFIED W <br />ARCH./ STRUCTURAL PLANS PRIOR TO THE PLACEMENT OF THE SLAB -ON -GROUND. <br />27 ALL CONCRETE SHALL COMPLY WITH ACI-318 AND HAVE A MAXIMUM SLUMP OF 4" AND HAVE A MINIMUM <br />SPECIFIED 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. CALCIUM CHLORIDE OR ANY ADMIXTURES <br />CONTAINING CALCIUM CHLORIDE SHALL NOT BE USED. <br />28 CONCRETE SHALL BE WELL CONSOLIDATED, ESPECIALLY IN THE VICINITY OF POST -TENSIONING ANCHORAGES. <br />FORMS SHALL BE STRIPPED WITHIN 5 DAYS OF CONCRETE PLACEMENT, BUT NO LESS THAN 24 HOURS. <br />29 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 AND BE INSTALLED PER ACI-318. ALL <br />REINFORCING SHALL BE SECURED AND SUPPORTED TO SUFFICIENTLY MAINTAIN THEIR POSITIONS UNTIL THE <br />CONCRETE HAS CURED. <br />30 WHERE REINFORCING STEEL IS SHOWN IN EXTERIOR BEAMS, PROVIDE MATCHING CORNER BARS LAPPED A <br />MINIMUM OF 30 BAR DIAMETERS. <br />34 FULLY STRESSED TENDONS SHALL BE CUT 1" WITHIN THE FACE OF THE CONCRETE. AFTER THE TENDON TAILS <br />HAVE BEEN CUT OFF, A RUST PREVENTATIVE MATERIAL SHALL BE COATED ON THE EXPOSED ANCHOR AND <br />TAIL. THE STRESSING POCKETS SHALL THEN BE FILLED WITH A STIFF, NON -SHRINK GROUT. <br />35 SEE STRUCTURAL DRAWINGS FOR ATTACHMENT OF STUD WALLS TO FOUNDATION. INTERIOR FOOTINGS SHALL <br />BE CENTERED UNDER LOAD BEARING WALLS TO DISTRIBUTE LOAD EVENLY TO FOUNDATION. SEE <br />STRUCTURAL DRAWINGS FOR DIMENSIONS. <br />36 THESE SLABS SHALL BE DESIGNED USING THE PROPERTIES OF THE ABOVE REFERENCED GEOTECHNICAL <br />REPORT. ENGINEER OF RECORD IS NOT RESPONSIBLE FOR DIFFERENTIAL SETTLEMENT, SLAB CRACKING, OR <br />OTHER FUTURE DEFECTS RESULTING FROM UNREPORTED CONDITIONS, OR CONDITIONS VARYING FROM <br />THOSE SPECIFIED IN GEOTECHNICAL REPORT. <br />01 THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL <br />CHAPTERS OF THE 2007 FLORIDA BUILDING CODE (FBC). ALL WORK SHALL BE PERFORMED IN ACCORDANCE <br />WITH THIS CODE AND ALL LOCAL REQUIREMENTS. <br />02 DESIGN LOADS: <br />A. SEE DESIGN CRITERIA ON STRUCTURAL DRAWING S4.01. <br />B. FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. <br />C. WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />D. COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS <br />E. DESIGN ROOF SNOW LOAD: N/A <br />F. SEISMIC: N/A <br />03 ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE ARCHITECT PRIOR TO <br />CONSTRUCTION OF WORK. <br />04 THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY <br />ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY THE <br />ARCHITECT / ENGINEER OF ANY DISCREPANCIES. <br />05 IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY <br />CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE <br />MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. <br />06 REFER TO SHEET S4.00 FOR FRAMING GENERAL NOTES <br />® FOUNDATION PREPARATION CONCRETE <br />01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF BASED ON A <br />GEOTECHNICAL REPORT BY FAULKNER ENGINEERING SERVICES DATED SEPTEMBER 24, 2007. SHOULD <br />CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF <br />WORK. <br />02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL. <br />03 CONCRETE FOR FOUNDATIONS: <br />A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: <br />FOOTINGS 3000 PSI <br />SLAB ON GRADE 3000 PSI <br />WALLS 3500 PSI <br />B MAXIMUM CONCRETE SLUMP SHALL BE 4". <br />C SLAB ON GRADE SHALL BE 4" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN <br />ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY <br />CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89. <br />D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS <br />318, 304 AND 301. <br />E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. <br />F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM Al85. <br />G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS. <br />H REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: <br />SLAB ON GRADE 1-1/2" <br />WALLS 2" <br />FOOTINGS 3" <br />I GRADE BEAMS SHALL BE FORMED ON SIDES. <br />04 ALL FILL SHALL BE PLACED IN 12 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL <br />MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS <br />SELECT, WITH LESS THAN 12% PASSING THROUGH THE NO.200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE <br />CONTENT AND ENERGY TO PROVIDE 95% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE. THE UPPER <br />1-FOOT BELOW PAVEMENTS SHOULD BE COMPACTED TO 98% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY. <br />IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 10,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL, <br />AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED <br />TO FALL BELOW 90% COMPACTION. <br />05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF T-6" BELOW FINAL GRADE WHEN BEARING ON SOIL, <br />UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS. <br />06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2 <br />HORIZONTAL. <br />07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH <br />OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING <br />AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95% <br />DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF V-6" TO BOTTOM OF CONCRETE. <br />08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY <br />BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK <br />WITH #6 x T-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING V-6" INTO ROCK. NO <br />FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION <br />BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS. <br />09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE <br />EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE. <br />10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING <br />OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY <br />BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF <br />BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL. <br />11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION. <br />ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO <br />HORIZONTAL. <br />12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND <br />OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED. <br />13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP <br />OF THE COMPACTED SUBGRADE SHALL BE INSTALLED. <br />01 ALL CONCRETE WORK TO COMPLY WITH ACI 301 AND 304 RECOMMENDED PRACTICE FOR MEASURING, <br />MIXING, TRANSPORTING AND PLACING CONCRETE. <br />02 EXTEND BOTTOM OF ALL FOUNDATIONS AT PERIMETER OF BUILDING 12" MINIMUM BELOW FINISHED GRADE, <br />U.N.O. <br />03 MINIMUM CONCRETE STRENGTH SHALL BE 3000 PSI AFTER 28 DAYS, U.N.O. PROVIDE TEST REPORTS ON <br />EACH BUILDING TO THE OWNER AND THE ARCHITECT. <br />04 PROVIDE STEEL TROWEL FINISH FOR ALL INTERIOR SLAB AREAS. PROVIDE BROOM FINISH TEXTURE FOR ALL <br />EXTERIOR SLAB AREAS U.N.O. ALL HANDICAPPED RAMPS SHALL BE BROOM FINISHED PERPENDICULAR TO <br />THE SLOPE. <br />05 PROVIDE CONCRETE SLAB FOR AIR CONDITIONER COMPRESSOR AS REQUIRED BY EQUIPMENT <br />MANUFACTURER. COORDINATE PLACEMENT OF SLAB WITH FINISH GRADING AT COMPRESSOR LOCATION. <br />06 ALL SIDEWALKS SHALL SLOPE AWAY FROM BUILDING. <br />SUBMITTALS <br />01 THE FOLLOWING ITEMS REQUIRE SUBMITTAL OF SHOP AND ERECTION DRAWINGS FOR REVIEW: (IF <br />APPLICABLE) <br />A REINFORCING STEEL FOR CAST -IN -PLACE CONCRETE <br />B CONCRETE DESIGN MIXES <br />02 THE FOLLOWING ITEMS REQUIRE SUBMITTAL OF SHOP AND ERECTION DRAWINGS AND STRUCTURAL <br />CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THIS <br />PROJECT: <br />A STEEL STAIRS <br />B TIMBER TRUSSES AND/OR WOOD I -JOISTS, STRUCTURAL AND TIMBER FABRICATIONS <br />C PRE -STRESSING TENDONS <br />•%•� wren <br />=lllclll �� <br />11=III= Oki / ENGINEERING <br />r11=U1 ti GROUP <br />FL CofA #7992 <br />5728 Major Blvd., Suite 603, Orlando, FL 32819 <br />Tel. (407) 354-5411 Fax (407) 354-3466 <br />Web Site: www.mgmdaren.com <br />F. <br />a <br />Ba <br />` FORUME <br />I? <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />0 <br />c 745 orienta avenue, suite 1121 <br />m altamonte springs, tl 32701 <br />f phone: 407.830.1400 <br />05 fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />0 <br />a <br />Q <br />Fort King <br />Colony <br />Apartments <br />City of Zephyrhills, FL <br />SET DISTRIBUTIONS: <br />EDITED BY: JT <br />z PROJECT NO. 10-2651 <br />z <br />rn <br />General Notes - <br />Structural <br />z <br />U.. U <br />z 31 PRESTRESSING STEEL: PRESTRESSING STEEL USED IN TSI MONOSTRAND UNBONDED POST -TENSIONING OF <br />TENDONS SHALL BE 7-WIRE STRAND AND BE CLEAN AND FREE FROM CORROSION. STEEL WILL CONFORM TO "d. R10t.•' :5 <br />ASTM A-416, GRADE 270 LOW RELAXATIONU. <br />ar R. '41 0 <br />L . <br />S3.00 <br />