FINISHED GRADE <br />[COVER PER TRENCH DETAIL <br />10' MIN 10' MIN . /- PROPOSED UTILITY <br />FULL LENGTH OF �--SEE MIN VERTICAL <br />PIPE CENTERED SEPARATION <br />AT CROSSING —+ - REQUIREMENTS <br />EXISTING UTILITY <br />gPIPE <br />OPTION 1 (SUFFICIENT COVER AND SEPARATION AVAILABLE) <br />/- FINISHED GRADE <br />A <br />COVER PER <br />TRENCH DETAIL <br />`1.;. 6" MIN <br />12" MIN <br />(TYP) <br />EXISTING UTILITY <br />10'-0" MIN <br />� A� <br />PIPE <br />\-SAND CUSHION <br />10'-0" MIN <br />11.25' ELB (TYP) <br />SEE NOTE <br />PROPOSED UTILITY <br />NOTE: <br />WITH APPROVAL OF THE ENGINEER, CONTRACTOR MAY DEFLECT PIPE INSTEAD OF USING FITTINGS. <br />ALTERNATE OPTION 1 (SUFFICIENT COVER OR SEPARATION NOT AVAILABLE) <br />PROPOSED UTI <br />PROPOSED UTILITY <br />OVER PER TRENCH DETAIL <br />FULL LENGTH OF <br />PIPE CENTERED <br />AT CROSSING <br />DEPTH VARIES <br />-EXISTING UTILITY <br />SEE MIN VERTICAL <br />SEPARATION <br />REQUIREMENTS <br />I <br />10' MIN 10' MIN <br />PIPE <br />NOTE: <br />WITH APPROVAL OF ENGINEER, CONTRACTOR MAY DEFLECT PIPE <br />INSTEAD OF USING FITTINGS. <br />OPTION 2 (SUFFICIENT SEPARATION AVAILABLE) <br />PER TRENCH DETAIL <br />B <br />SAND CUSHION <br />10'-0" MIN T B <br />DEPTH VARIES <br />EXISTING UTILITY <br />12" MIN <br />(TYP) <br />6" MINI <br />CONCRETE ENCASEMENT W/ <br />-11.25* ELB (TYP) MINIMUM 6" COVER PROPOSED UTILITY <br />SEE NOTE <br />a <br />SAND CUSHION <br />EXISTING UTILITY <br />FINISHED GRADE <br />10'-0" MIN <br />J <br />SECTION A -A <br />EXISTING UTILITY <br />`�'" SAND CUSHION <br />11.25' ELB (TYP) PROPOSED UTILITY <br />SEE NOTE 2 I <br />gPIPE <br />NOTES: <br />1. FOR PROPOSED WATER MAINS, THIS OPTION IS ONLY ALLOWED WITH APPROVAL OF FDEP AND <br />THE ENGINEER. <br />2. WITH APPROVAL OF THE ENGINEER, CONTRACTOR MAY DEFLECT PIPE INSTEAD OF USING FITTINGS. <br />ALTERNATE OPTION 2 (SUFFICIENT SEPARATION NOT AVAILABLE) <br />EXISTING UTILITY <br />PROPOSED UTILITY <br />POTABLE <br />GRAVITY <br />SEWAGESEWAGE <br />STORM <br />RECLAIMED <br />ELECTRIC <br />COMMENTS <br />WATER <br />FORCE MAIN <br />WATER <br />TELECOMMUNICATIONS <br />SEWER <br />POTABLE WATER <br />1'-0" <br />1'-6" <br />1'-6" <br />1'-0" <br />1'-0" <br />1'-0" <br />SEE NOTE 1 <br />GRAVITY SANITARY SEWER <br />1 r <br />1 r -Orr <br />1 r-O» <br />11-6n <br />11 -6u <br />1$ <br />1I-0if <br />SEWAGE FORCE MAIN <br />r-6n <br />1 -6" <br />1 r -0rr <br />1 r -On <br />1 ' -0" <br />1 -6,r <br />1' -0 <br />SEE NOTE 2 <br />STORM <br />1'-0" <br />1'-6" <br />1'-6" <br />1'-0" <br />1'-6" <br />1'-0" <br />RECLAIMED WATER <br />1'-6" <br />1'-6" <br />1'-6" <br />1'-0" <br />1'-0" <br />1'-0" <br />SEE NOTE 2 <br />ELECTRIC <br />1'-0" <br />1'-0" <br />1'-0" <br />1'-0" <br />1'-0" <br />1'-0" <br />TELECOMMUNICATIONS <br />NOTES: <br />1. ONLY OPTION 1 CONSTRUCTION IS ALLOWED WITHOUT APPROVAL OF THE ENGINEER. <br />2. ONLY OPTION 2 CONSTRUCTION IS ALLOWED WITHOUT APPROVAL OF THE ENGINEER. <br />MINIMUM VERTICAL SEPARATION REQUIREMENTS <br />CONCRETE ENCASEMENT W/ <br />MINIMUM 6" COVER <br />SECTION B-B <br />EXISTING UTILITY <br />PROPOSED UTILITY <br />POTABLE <br />GRAVITY <br />SEWAGESEWAGE <br />STORM <br />RECLAIMED <br />ELECTRIC <br />TREE <br />WATER <br />SEWER <br />FORCE MAIN <br />WATER <br />TELECOMMUNICATIONS <br />POTABLE WATER <br />1'—O" <br />6'-O" <br />6'-0" <br />3'-O" <br />3'-0" <br />3'-0" <br />GRAVITY SANITARY SEWER <br />10f -0» <br />1f -0» <br />f <br />3 -0» <br />5r -0» <br />5r -0» <br />3r -0» <br />SEWAGE FORCE MAIN <br />10'-0" <br />1'-0" <br />1'-0" <br />3'-0" <br />3'-0" <br />3'-0" <br />STORM <br />3'-0" <br />5'-0" <br />3'-0" <br />1'-0" <br />3'-0" <br />3'-0" <br />1 D'-0" <br />RECLAIMED WATER <br />3'-O" <br />5'-0" <br />3'-0" <br />3'-O" <br />1'-0" <br />3'-O" <br />ELECTRIC <br />3'-0" <br />3'-0" <br />3'-0" <br />3'-0" <br />3'-0" <br />2'-O" <br />TELECOMMUNICATIONS <br />NOTE: <br />UTILITIES SHALL NOT BE INSTALLED WITHIN THE DRIP LINE OF TREES WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. <br />TYPICAL UTILITY CROSSING DETAIL �1\ <br />NTS <br />MINIMUM HORIZONTAL SEPARATION REQUIREMENTS <br />PROPOSED UnL" Iq <br />SEE MIN <br />HORIZONTAL <br />SEPARATION <br />REQUIREMENTS <br />i EXISnNG Unuw <br />PLAN VIEW <br />0 <br />J <br />J <br />� <br />� <br />= <br />Z <br />a <br />W <br />=0 <br />= <br />O <br />W <br />Z <br />NLL <br />Q <br />0 <br />W <br />i <br />W <br />00 <br />0 <br />N <br />o <br />oo <br />C <br />Vppao�aomw <br />V o <br />= N M� M N 1 <br />ti <br />W_j M J g 0 <br />3 xtiJu.w- ti <br />3 CO <br />L <br />o <br />c c'w <br />_ <br />.v <br />YaY x <br />W40.m°,.° <br />J N J <br />Go <br />N <br />Engineer Sheet <br />WCT <br />Date <br />7/16/18 <br />Scale 7 <br />NA <br />
The URL can be used to link to this page
Your browser does not support the video tag.