Laserfiche WebLink
CROSS BRACING DETAIL (TYP.) <br />SCALE: N.T.S. <br />TRUSS NOTES: <br />CONY. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE 1N ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER &SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />rvr c-rvu r rII rr�u <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX & EACH END ALTERNATE A CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />----LWOOD TRUSS - <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: N.T.S. <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />4" t <br />1-4" <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/ <br />#3 STIRRUPS AT 4'-0" <br />WHEN DEPTH <br />EXCEEDS 30" <br />GRADE <br />(V <br />T <br />PORCH SILL 15 <br />SCALE: N.T.S. <br />DIAGONAL <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 (2) #7X 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 RAFTERS FOR SPANS 4FT TO 8FT <br />2X4 RAFTERS FOR SPANS LESS THAN <br />4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO BEAM <br />2X4 CONT. AT--/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SEE FLOOR PLAN SEE PLAN FOR <br />FOR BRG. OR REQ'D STAIR INFO. <br />NON-BRG. WALL IF CONCRETE STAIRS <br />FORMED & POURED <br />W/ (1) #5 EACH STEP <br />121- <br />w <br />4,r <br />z <br />U <br />N <br />PORCH SLAB SEE <br />FOUNDATION PLAN <br />(2) #5's CONT. T&B <br />iw <br />% <br />w z <br />W/ #3 STIRRUPS AT <br />iv z <br />--�, <br />4'-0" WHEN DEPTH <br />. <br />T <br />EXCEEDS 30" <br />LOWER OR <br />GARAGE SLAB <br />1, <br />SEE PLAN <br />LARGE STEP <br />DOWN <br />�jj <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />ES <br />(2) 12D NAILS —' <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />SCALE: N.T.S. <br />WOOD POST. SEE FLR__T <br />PLAN FOR SIZE & BASE <br />CONNECTION SEE <br />PLAN <br />EXTEND <br />SLAB 1 1/2" <br />-,k <br />(2) #5's CONT. T&B w/ <br />4" <br />#3 STIRRUPS AT 4'-0" <br />PORCH SLAB SEE WHEN DEPTH <br />FOUNDATION PLAN EXCEEDS 30" <br />GRADE <br />HIP - <br />G.T ' r <br />1'-4° <br />ENTRY PORCH SILL 14 <br />SCALE: N.T.S. <br />WOOD OR MASONRY ABOVE <br />MASONRY PIER SEE FLOOR PLAN <br />FOR COLUMN INFO WOOD OR MASONRY —\I <br />INTEGRATE MASONRY ABOVE MASONRY <br />I KNEEWALL INTO CMU BASE OR PLAN FOR COLUMN <br />PIER SEE FLOOR <br />MAIN HOUSE PER ELEVATION IF I <br />REQUIRED INFO <br />1 1 MASONRY KNEE WALL MAX 3 = <br />1 ' 1 COURSES w/ TOP K.O. COURSE CMU BASE W/ (1) #5 1 I 1 <br />z <br />O <br />w <br />J <br />w <br />=7 <br />w <br />w <br />. FILLED CELL VERTICAL EACH <br />SPAN MAX 6'-8" CORNER FILLED 1 1 <br />MAX 3 SOLID. SEE ELEV. <br />COURSE FOR BASE SIZE <br />(3) #5's EA. WAY <br />1 1 <br />8° <br />Ak SLAB PORCH SLAB SEE <br />LEVEL FOUNDATION PLAN <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />—#5 REBAR CONT <br />@ SLAB LEVEL <br />—EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/, z <br />CONTRACTOR TO INSTALL SEE CUT #3 STIRRUPS AT 4'-0" <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" 1'4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />1 <br />TOP COURSE TO <br />BE CHAIR BLOCKS. <br />ENTIRE BASE TO <br />BE FILLED SOLID <br />SEE ELEV. FOR <br />BLK HGT. <br />—#5 REBAR CONT <br />@ SLAB LEVEL <br />—EXTEND SLAB <br />1 1/2" BEYOND <br />BLOCK FACE <br />EXTEND <br />SLAB 1 1/2" <br />(2) #5's CONT. T&B w/, z <br />CONTRACTOR TO INSTALL SEE CUT #3 STIRRUPS AT 4'-0" <br />MIN 3" x 3" WEEP HOLE SECTION FOR WHEN DEPTH <br />ALONG w/ PITCHING SLAB MORE INFO EXCEEDS 30" 1'4" <br />TO DRAIN WATER <br />KNEEWALL OPT. (ELEV TO INDICATE) MASONRY COLUMN <br />ENTRY PORCH SILL 16 <br />SCALE: N.T.S. <br />1 <br />I w/(1)#5CONT <br />SIMPSON LSTA18 <br />W/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />----------� <br />-- <br />SEE PLAN <br />SIMPSON HUC410 w/ (14) <br />FOR CANT. <br />16d INTO HEADER & (6) <br />1 1 <br />I <br />I 10d INTO BEAM - SEE <br />I <br />I <br />I <br />I ROOF PLAN FOR MORE <br />I <br />I <br />I <br />I <br />l <br />I INFO <br />I <br />1 <br />SEE FLOOR PLAN FOR <br />i <br />COLUMN SIZE & BASE <br />1 <br />I <br />I <br />I <br />.. — 7/16" OSB FLITCH PLATE <br />CONNECTION INFO <br />i <br />i <br />REQ'D ONLY WHEN <br />---- — <br />— <br />--_j <br />1 <br />L__ <br />INDICATED ON BM. <br />SCHEDULE/PLAN <br />7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN <br />COLUMN SIZE & BASE <br />OPTION <br />A INDICATED ON <br />OPTION <br />B <br />CONNECTION INFO <br />OPTION <br />SC EDULE/PLANM <br />C <br />i v <br />EXTERIOR SHEATHING COMMON -BM. TO POST ATTACHMENT ('_A� <br />2X4 STUDS w/ SIMPSON <br />ATTACHED PER <br />NAILING SCHEDULE <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />SP1 w/ (10) 10d NAILS <br />, <br />CONNECTION INFO. <br />AT BASE SEE J/S6 FOR <br />MORE INFO. <br />l <br />ti <br />2x4 BASE PLATE W/ <br />` <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR <br />I <br />SIMPSON MTS12 w/ <br />(14) 10d x 1 1/2 NAILS SIMPSON (2) HTS20 w/ (14) <br />TO FLOOR GIRDER 10d NAILS TYP. U.N.O. <br />BELOW @ 16" O.C. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />A A <br />SEE PLAN FOR <br />TOP OF WAM <br />I <br />—J <br />SEE PLAN FOR <br />CANT. IF <br />INDICATED <br />CORNER -- SEE FOUNDATION <br />SECTION @ FLOOR <br />CONNECTION 22 <br />SCALE: N.T.S. <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />TRUSS OR <br />/ <br />/ ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL 7 <br />SCALE: N.T.S. <br />2x4 #2 SYP NAILER. NA <br />TO STUDS w/ (3) 16d @ <br />EACH STUD - TOENAIL <br />EACH TRUSS TO <br />NAILER w/ (3) 10d <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY w/ <br />(3) ROWS OF 16d NAILS <br />AT 24" O.C. <br />ROOF AND EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />VERIFY FLOOR JOIST W/ RIM <br />BOARD OR FLOOR GABLE W/ <br />FRAMING PLAN <br />SIMPSON LUS26 w/ (8) 10d / • <br />NAILS OR IF 2 PLY TRUSS SIMPSON LUS26-2 w/ (8) 16d SEE FLOOR FRAMING PLANAND J/S6 FOR MORE INFO. <br />NAILS TO LEDGER VERIFY WITH PLAN FOR <br />2X8 #2 SYP CONT. LEDGER W/ LOCATION AND DIRECTION <br />(4) 16d NAILS ATTACH NAILS (IF PARALLE SEE 2/D2 FOR <br />INTO END OF EACH FLOOR BLOCKING INFO) <br />TRUSS, 24" O.C. MAX. (AT EACH <br />SIDE OF G.T. INSTALL (4) NAILS MASONRY WALL <br />EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: 1/2" = 1'-0" <br />Y2' CDX PLYWOOD OR <br />SHEATHING REQ'D FR <br />OF WALL TO ROOF SH <br />ABOVE W/ 8d NAILS @ <br />FIELD, EDGES & BOLIN <br />2x4 #2 SPF STUDS @ <br />—'� 12" O.C. W/ USP SPT22 <br />ti @ BASE & SPT24 @ <br />ti TOP <br />v <br />2x4 #2 SYP P.T. PLATE W/ <br />V8" EPDXY ANCHOR OR <br />2„ J-BOLT OR Y TITEN HD <br />ANCHOR @ 24" O.C. W/ <br />SEE PLAN MAX. MIN. 6" EMBEDMENT <br />- 24" STEPS <br />X �°- X d , � ' X <br />SEE PLAN FOR OPT. - - "- <br />STAIR INFO. IF 1 <br />CONCRETE STAIRS MAIN HOUSE <br />FORMED & POURED <br />SLAB <br />W/ (1) #5 EACH STEP <br />141 <br />(2) #5's CONT. T&B <br />w/ #3 STIRRUPS AT <br />4'-0" WHEN DEPTH <br />° .. ° .a. c . EXCEEDS 30" <br />GARAGE OR <br />LOWER SLAB <br />SEE PLAN <br />SECTION GARAGE MONO 21 <br />SCALE: N.T.S. <br />M <br />cv <br />c <br />tV <br />C" <br />o <br />cn <br />W <br />=� <br />>� <br />t/5 ro O <br />N_ . <br />V7 C <br />Q cam+ Y <br />�ss� <br />z <br />3 ra <br />c o <br />N G <br />c E <br />o <br />a <br />o <br />4 Q .r- <br />�: <br />F 1.O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />�8 <br />V <br />N N m <br />N r <br />_Co <br />N <br />0 <br />- w <br />3 Q <br />0 <br />1 <br />-i <br />m w w <br />Jwii a <br />w <br />�o — a Sc <br />Z <br />L Nj 2� <br />�2p <br />. �• <br />Wcin2O <br />> 'rN CO o <br />u <br />w <br />LC Z <br />coz - & <br />s <br />Z <br />N OU 0 <br />W <br />❑ ❑ <br />z � M <br />z a'o13 <br />z a <br />o <br />Q <br />a <br />— N <br />�Q) <br />w <br />�_ <br />r6 <br />� <br />C, <br />� <br />U <br />Ow$ <br />�Ln <br />N <br />C <br />U <br />_w J <br />f— <br />$ <br />m I �. <br />.. <br />� <br />• � � <br />sm <br />ti <br />o <br />Cl)Z <br />w <br />o <br />Q <br />O E <br />n. E <br />❑a <br />Z <br />I`° <br />O <br />10 <br />U❑ <br />as <br />Wz <br />0° <br />o< <br />Nw2 <br />�im� <br />.0 <br />w <br />�'� <br /><o <br />N>z <br />o� <br />Z�i <br />_l <br />7 <br />g N <br />[7_ � <br />o <br />LLa <br />go W <br />N <br />W <br />$LL <br />=3 <br />�r <br />�CD <br />O <br />v <br />w <br />z< <br />a� <br />°3 <br />0 <br />C)2 <br />= <br />> Lo <br />0 <br />m <br />CU <br />ns <br />c� <br />L <br />(10 <br />m <br />0 <br />O <br />O <br />a <br />m <br />C <br />Lf <br />co <br />C� N <br />0 <br />c0 O <br />Ln <br />T' <br />M L <br />r <br />E <br />2 <br />cn <br />M N <br />Z <br />l4 <br />E O <br />m T <br />a <br />.. <br />U <br />Q cc 0 <br />d) <br />JOB <br />NO : <br />22-12355 <br />SCALE: <br />AS NOTED <br />SHEET NO. <br />D 1 <br />