My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36420 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36420 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:57:20 PM
Creation date
2/18/2025 3:19:58 PM
Metadata
Fields
Template:
Building Plans
Street #
36420
Location
Garden Wall Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A1200A INDOOR <br />PANEL CENTER <br />10 s14 to lights 8 outlets <br />NEMA 1 10 N12 to appliances and GFI <br />150 AMPI <br />200 AMP 10 #10 to wH <br />10 N8 to Range <br />10 a6 t0 HVAC <br />METER <br />150=2/0 <br />200=4/0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />ND <br />D <br />ne <br />ct <br />__,i <br />SERVICE BY POWER <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />04 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />. Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />GENERAL ELECTRICAL NOTES <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type Installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI ILL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the Installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would Include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The Width of the sink or range is not to be included In the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FITT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />rwl <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />CH <br />PB <br />SD <br />USB <br />02 <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />1.5" VTR III 3" VTR <br />III I, <br />I <br />I I <br />I I <br />I � I <br />\ III3" VTR <br />I Off I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ITCH FOR <br />POSAL <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANC <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />A/C PAD <br />DISC. WP <br />GFI <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />FI `1--DB & GFI TO <br />------- I BE ALIGNED <br />VERTICALLY <br />I <br />I <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / '� PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I---------- <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L--------------------------------------j <br />SECOND FLOOR ELECTRICAL PLAN <br />FIRST FLOOR ELECTRICAL PLAN — ELEV—A <br />ELEV—A <br />a+7 <br />cv <br />0 <br />ca <br />— <br />.o <br />Q <br />• <br />V) 'C� N t <br />Vf O <br />3 d w <br />co c r� <br />c E <br />ea m <br />a � <br />0 <br />N <br />N <br />cg <br />c2 <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. <br />Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages beating <br />Engineers signature and seal. <br />W <br />M <br />gam$ N <br />0 <br />0 <br />n 0 <br />� at <br />M v ,e <br />Qu-'.u- 3 <br />. a <br />— a 4 <br />0 <br />W <br />_ <br />�pjQ' <br />ILL <br />W <br />m w <br />0 <br />0 <br />Y <br />04 <br />O U U <br />W <br />Cfii <br />Cp <br />0 <br />Z(14 <br />o <br />z Go <br />ti <br />2 <br />(n V) <br />a <br />Z: <br />3 <br />ty <br />_U' <br />(10 <br />LL <br />N�U <br />LU <br />V) <br />V) <br />c <br />0 <br />w <br />LL_ <br />E <br />zo <br />aLL <br />>iy <br />z0 <br />EE <br />E U <br />Z <br />- <br />as <br />&� <br />a; �$g <br />� <br />< <br />y <br />RZ <br />ms <br />h K <br />2 <br />yy C <br />>t5 <br />Z <br />VJ � <br />ab <br />fy <br />dz <br />U <br />�ii <br />J <br />15 <br />oL <br />U Ti <br />M <br />J <br />M <br />0 <br />CID <br />Q <br />(n <br />o <br />N <br />m <br />c <br />I� <br />.� <br />O O <br />V) <br />NQ <br />I <br />r <br />CM N <br />o <br />Z <br />Z <br />E <br />0 <br />c <br />a <br />rJ <br />JOB <br />NO: <br />22-12358 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.