Laserfiche WebLink
FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />co <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />12 <br />5 5 <br />FLASHING <br />- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -- — — — -------------------------------------------------------- -- ------ — <br />CJ / WEEP <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />------ I-- <br />35 SH <br />SCORED <br />STUCCO <br />BANDS <br />r <br />" <br />SILL DETAIL <br />SCALE: 3/4" = V-0" <br />SCORED <br />STUCCO <br />BANDS <br />HEAD DETAIL <br />SCALE: 3/4" = 1'-0" <br />2ND F <br />_T.O.M. <br />------------ ---- <br />_T.00.M. (cry GAR. <br />/ENTRY <br />_HDR_ HGT., <br />SCORED <br />STUCCO <br />BANDS <br />----------------------------I--------1------------------------I--- FIN. FLR. <br />LEFT ELEVATION - ELEV-B. <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.xl-1/2" long (3/4"-1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />� o <br />a -� �- <br />�-cc nX <br />«,ci- <br />cc cp <br />' <br />c <br />E <br />o <br />x`ittlOW <br />1V,,��fJ�ir <br />�� <br />.. <br />< <br />_ <br />1.0•s <br />�°� �FE SS <br />(/"' TllQ!llilkst?�"`�� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W �oE <br />4 8 <br />U N <br />0 °' _ <br />ai ejM V i <br />Q U LL LL , u! <br />Lu EL <br />a W <br />0 <br />Z Farn <br />i .0 R 9 O <br />w <br />� � c � <br />W <br />W m <br />Z N M Z Q <br />L U <br />Z OU <br />L) o <br />U <br />� N M <br />z S <br />z o <br />J <br />M <br />to <br />C <br />^ 1 <br />VJ O <br />VJ <br />W <br />� <br />I` <br />U <br />0 -� <br />w o <br />N c w <br />U <br />w <br />E <br />aim 8 <br />I <br />¢ Y <br />sm <br />C <br />W <br />M <br />Cl) <br />y¢ <br />o <br />Z <br />J <br />LL <br />E <br />zo <br />>ry <br />Q o <br />E U <br /><� <br />(a <br />_ <br />g� <br />U <br />�¢ <br />UO <br />0 <br />0Q <br />C <br />O C <br />N ruo <br />¢z <br />Q <br />wZ <br />L <br />c j CY <br />Z <br />U <br />'0 <br />o� <br />N <br />�0 <br />QW <br />�w <br />o <br />Q <br />o<U <br />LL <br />a <br />ww <br />son <br />a� <br />=S <br />Q <br />Z¢ <br />a <br />OUP <br />0 <br />� O <br />> M <br />Orn <br />may„ <br />v <br />m <br />� <br />0 <br />O <br />7� <br />IQ �I--. c <br />T <br />7-3 O <br />^ <br />Cr �L M <br />O <br />^ <br />v / <br />N <br />L�L <br />I� <br />m <br />C: <br />LO <br />CID <br />O <br />O <br />00 <br />LO <br />N <br /><C <br />T- <br />CD <br />E <br />M N <br />C <br />o <br />t6 <br />T <br />7 in <br />E r T <br />= <br />LL <br />iv <br />U J Q <br />J <br />JOB <br />NO: 22-12359 <br />SCALE : AS NOTED <br />SHEET NO. <br />2.1 <br />l ! 11 T f11- l Ir , - __-T <br />