My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36428 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36428 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:58:25 PM
Creation date
2/18/2025 3:20:26 PM
Metadata
Fields
Template:
Building Plans
Street #
36428
Location
Garden Wall Way
Contractor
Lennar Home
Building Plans - Permit #
5694
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />Fff <br />0W.P. <br />G.F.I. <br />$3 <br />?4 <br />$R <br />P.C. <br />CH <br />PB <br />DB <br />SD <br />0 <br />USB <br />a <br />❑TV 2 <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />150A/200A INDOOR <br />PANEL CENTER <br />10 #14 to lights 8 outlets <br />NEMA 1 P #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 #10 to WH <br />#8 to Range <br />10 #6 to HVAC <br />.7R—T <br />MO <br />200 amp <br />150 amp <br />UNDERGROUND 1Dis <br />SERVICE BY POWER CO.—� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />150=2/0 <br />200=4/0 in 2" Conduit <br />Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250,52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1.5" VTR <br />I <br />,II <br />I <br />I <br />—111 3" VTR <br />I � � <br /><� I I <br />I I I 141t VTR <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN SWITCH <br />DISP( <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) / { <br />TELEPHONE (OPTIONAL) <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) \ <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />PLUMBING RISER <br />SCALE: NTS <br />KITCHE <br />.It il�llllll'rrr�x>Cs� <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />DEDICATED <br />RECEPTACLE FOR <br />ICROWAVE RANGE <br />HOOD PER SPECS <br />A/C PAD <br />GFI WP DISC. <br />A <br />/ I <br />I <br />'IENTR�P <br />DB &GFI TO I GFI <br />BE ALIGNED — — — — — — — <br />VERTICALL <br />I <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />COACH LIGHTS COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS \ �. PER SPECS <br />ROUGH -IN FOR OPT. CEILING FAN I SPEC 3&' 4 KITCHEN FIRST FLOOR ELECTRICAL PLAN - ELEV-B <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />SCALE: %4"=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />L----------- I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1 I <br />1 I <br />I I <br />I I <br />I I <br />I 1 <br />I I <br />I 1 <br />I I <br />I I <br />I i <br />I I <br />L-------------------------------------- J <br />SECOND FLOOR ELECTRICAL PLAN <br />ELEV-B <br />eN , <br />-a ;� <br />Q <br />wUj <br />_01. <br />c"V N <br />em u- n <br />Ut <br />vi; <br />W- A=c <br />w <br />1r <br />L <br />IV a�'• S8 <br />u...sa <br />c � <br />N <br />0 <br />N <br />C.0 <br />0 <br />CV <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W <br />4 <br />E <br />$ <br />0 <br />S <br />M <br />tA�r <br />M <br />Q <br />C <br />04 CD <br />th V <br />C J LL W <br />o LL LL a <br />— 'S ` <br />Z <br />°' <br />L <br />Q <br />Y O <br />W <br />3�n�_ o <br />Z <br />IL <br />inm <br />Cl)Z Q J <br />Z <br />N <br />OU < v <br />W <br />El 0 <br />0 Cl) <br />N (h <br />o g <br />V <br />a <br />QW <br />N <br />Ln <br />M <br />v <br />0 a <br />w <br />to <br />U� <br />0111CD <br />0 <br />V1 � <br />�N <br />� <br />U <br />W <br />J <br />z <br />U o <br />C U) <br />�Q <br />Q vaO o <br />N rn <br />�m <br />o <br />CDz <br />Z <br />Cy'3 <br />M <br />¢ <br />zo <br />ILL. <br />E <br />-K <br />° <br />QO <br />iZ <br />ECU 0 <br />o <br />Z® <br />p a <br />U <br />OU <br />p <br />Z�: <br />N ro <br />a <br />wo <br />K a <br />ww <br />It¢ <br />o <br />o <br />ro <br />f0 <br />fn C <br />z z <br />01 <br />o <br />o� <br />z <br />Jz <br />a) <br />S< <br />Z <br />3°0 <br />Q 3 <br />W <br />a <br />�w <br />W <br />U <br />as <br />0 <br />aE <br />=Of <br />�- <br />Z <br />=3 <br />7� <br />O <br />C.0 <br />a <br />C <br />zlaT�U <br />C O <br />0 <br />i <br />;nM <br />co <br />m <br />m <br />U <br />0 <br />co <br />cc <br />Y <br />(o <br />;— <br />m <br />C <br />^ <br />L / <br />..� <br />0 <br />-P <br />o N <br />.� <br />00 o <br />N <br /><< <br />`_' <br />Y <br />M N <br />o <br />M <br />Z <br />E T <br />m <br />m <br />11 <br />ECc 0 <br />U <br />Q p <br />c <br />JOB <br />NO: <br />22-12359 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />- -- - <br />, i T�7-TT-- iFtni: 1 a,,i I I r ra: mn ial i 1 auui. - <br />-�ii at inn-- II i i 1-1 _-- --- - I-- l - - - - - - - - - - - - - - - T— In - <br />