Laserfiche WebLink
r- - - - - - - - - - - - - - - - - - - - <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />L- - - - - - - - - - - - - - - - - - - - <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />F(2) <br />- 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 114 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 4 <br />S.H. <br />13 <br />20X38J <br />184X37i <br />S.H. <br />14 <br />20X50J <br />18JX50 <br />S.H. <br />15 <br />20 X 63 <br />18 J X 62 4 <br />S.H. <br />16 <br />20X72 <br />18}X71J <br />S.H. <br />14.12 <br />27 1/4 X 26 <br />26 X 25 J <br />S.H. <br />11-13 <br />271/4X38i <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 501 <br />26 x 50 <br />S.H. <br />1H5 <br />277'X63 <br />26X62112 <br />S.H. <br />1H6 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 J X 37 314 <br />S.H. <br />24 <br />37 J X 501 <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 i <br />S.H. <br />33 <br />54 X 38 J <br />52 J X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 4 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S. H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />SECOND FLOOR PLAN - ELEV-Al <br />SCALE: %4"=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Ed. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Ed. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />DA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />O <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WALL LEGEND <br />11111111111111111 � - -= <br />MASONRY HGT. @ 9'-4" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />FIRST FLOOR LIVING 1816 <br />SECOND FLOOR LIVING 1510 <br />LIVING TOTAL 3326 <br />GARAGE 453 <br />ENTRY 37 <br />TOTAL AREA 3816 <br />PATIO 24 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />c-i <br />O <br />ev <br />c <br />a <br />� W <br />C%A <br />o L <br />X <br />y.: C W G1 <br />y R O L <br />N © f0 <br />lV � <br />N d <br />0.1 <br />c <br />CD <br />ao A Q <br />rs ' 3 � <br />m y as .oi <br />• w as <br />_C2 <br />N d- <br />c E <br />o <br />a U <br />ae'�519i � k'i € a l 11 r id��pp <br />ow <br />` <br />" <br />*i lb <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />W <br />a <br />v E <br />8 <br />V <br />0 <br />N <br />0 C: U r <br />00w <br />N <br />U) Z <br />Ni <br />Q <br />Qj CNM0 � u' <br />C <br />J LL L LL W <br />a <br />Z <br />Lu <br />- '�� o- , <br />m <br />.� <br />W <br />C 9 o <br />=1 (6 N <br />m <br />Z <br />IL <br />U) w <br />L MZ a <br />N <br />O <br />O U <br />U <br />INNA W <br />D D <br />z � M <br />o g <br />z N <br />z � � <br />� <br />Q <br />IN <br />z a <br />o <br />�_ <br />+J <br />rsi <br />� w <br />_ g <br />'O^ <br />Iv I <br />w o <br />N <br />wa <br />(J <br />� <br />U <br />1- <br />L $ <br />y�1 <br />C) <br />N <br />Q <br />• <br />N <br />o <br />w <br />M <br />M <br />J <br />z <br />� <br />z <br />Z <br />Q <br />g <br />wE <br />ce <br />w� <br />Mo <br />zo <br /><R <br />Q O <br />E_ <br />oI <br />z© <br />p E <br />20 <br />-U <br />O¢ <br />00 <br />10 <br />0 w <br />L <br />wo <br />1z <br />Qp <br />m� <br />O F <br />? <br />m J <br />U <br /><° <br />Q W <br />�z <br />�� <br />5Z <br />a <br />agocn <br />C <br />w <br />4 0 <br />w <br />F r <br />m <br />hz <br />z. <br />�� <br />O <br />J <br /><F <br />>�I 0 <br />Cl) <br />ct <br />oIQ <br />2 <br />o � <br />2 r <br />= <br />w / <br />//L0 <br />N <br />m <br />co <br />Q <br />co <br />M <br />co <br />:3C:) <br />3: <br />C:) <br />r <br />Yco <br />r <br />C0 <br />m <br />c <br />' /� <br />u i <br />T <br />a-+ <br />a) M <br />Q0I <br />C:) <br />M <br />M N <br />Ln <br />M <br />Q <br />T' <br />w <br />co <br />M r <br />0 <br />z <br />z <br />E Q <br />v; <br />B <br />r`a <br />EL <br />U J <br />Q p <br />J <br />JOB <br />NO : <br />23-00523 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />