Laserfiche WebLink
1 IIL 1 I Ay E*Ii i"II'1 LI I! <br />CROSS BRACING DETAIL (TYP.) <br />SCALE:NTS <br />TRUSS NOTES: <br />CONY. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. Cg <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX & EACH END ALTERNATE CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. , <br />----LWOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE:NTS <br />DIAGONAL <br />AT 8'-0" <br />MAX <br />2X4 CON <br />T & B CF- <br />WOOD <br />TRUSS <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDINGPACK <br />MAX 24" SPAN (EITHER USSES HIP <br />SIDE OR BOTH IF REQ'D) C. <br />(2) 12D NAILS AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 (2) #7 x 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />,k 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO TIE BEAM <br />CONC.MASONRY <br />STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SCALE:NTS <br />SIMPSON LSTA18 <br />w/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />SCALE: NTS <br />(2) 2x8 #2 SYP w, <br />O.S.B. FLITCH PI <br />TOP @ TRUSS E <br />U.N.O. ON ROOF <br />PLAN <br />TYPIC <br />WALL <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN w/ (2) SIMPSON <br />HTS20 w/ (24) 10d x 1 1/2" <br />NAILS EACH <br />SIMPSON HU46/HUC46 w/ (8) <br />16d NAILS TO POST & (4) 10d <br />NAILS TO BEAM <br />SUPPORT COLUMN BUILT-UP <br />(2) 2x4's OR 4x4 w/ (2) 10d <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />(2) SIMPSON HETA20 w/ (8) 10d <br />x 1 1/2" NAILS EACH - OR (2) <br />SIMPSON MSTAM36 w/ (7) 10d <br />& (4) 1/4"x2 1/4" TITENS EACH <br />TIE BEAM <br />BEAM @ RAISED ENTRY <br />MASONRY WALL 4 <br />SCALE: NTS <br />SIMPSON HUC410 w/ (14) <br />SEE PLANFOR CANT. <br />16d INTO HEADER & (6) <br />10d INTO BEAM - SEE <br />ROOF PLAN FOR MORE <br />i <br />INFO <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE <br />OSB FLITCH PLATE <br />CONNECTION INFO <br />REQ'D ONLY WHEN <br />INDICATED ON BM. <br />SCHEDULE/PLAN <br />7/16" OSB FLITCH PLATE <br />SEE FLOOR PLAN <br />FOR <br />REQ'D ONLY WHEN <br />COLUMN SIZE & BASE <br />OPTION A INDICATED ON <br />SC EDU E/PLANM OPTION B CONNECTION INFO OPTION C <br />COMMON BM. TO POST ATTACHMENT K*� a� <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />SIMPSON MTS18 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A A <br />SEE PLAN FOR <br />SEE PLAN FOR <br />CANTILEVER IF <br />INDICATED <br />CORNER SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE:NTS <br />SCALE: 3/4"=V-0" <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />EXTERIOR <br />ATTACHED <br />SCHEDULE <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE PLAN <br />FOR BEAM SIZE <br />2x SPF #2 <br />AT 16" O.C. <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />KNEEWALL @ ENTRY FRONT WALL <br />SCALE:NTS <br />2X4 #2 SYP NAILER. NAIL <br />TO STUDS w/ (3) 16d AT <br />EACH STUD -TOENAIL ROOF AND EXTERIOR <br />EACH TRUSS TO NAILER SHEATHING ATTACHED <br />W/ (3) 10d PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />W/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY <br />W/ (3) ROWS OF 16d <br />NAILS AT 24" O.C. <br />SIMPSON LUS26 w/ (8) 10d NAILS <br />OR IF 2 PLY TRUSS SIMPSON <br />LUS26-2 w/ (8) 16d NAILS TO <br />SEE FLOOR FRAMING PLAN <br />LEDGER <br />AND J/S6 FOR MORE INFO. <br />2X10 #2 SYP CONT. LEDGER w/ (3) <br />VERIFY WITH PLAN FOR <br />LOCATION AND DIRECTION <br />1/2" X 41/2" LAG SCREWS ATTACH <br />(IF PARALLEL SEE 2/D2 FOR <br />LAG SCREWS INTO END OF EACH <br />BLOCKING INFO) <br />FLOOR TRUSS, 24" O.C. MAX. (AT <br />EACH SIDE OF G.T. INSTALL (4) LAG <br />MASONRY WALL <br />SCREWS EACH SIDE) <br />(TYPICAL) <br />SECTION AT LOW <br />ROOF g <br />SCALE:NTS <br />0 <br />VARIES <br />X—Amr - 2x STUDS @16" O.C. <br />,,r w/SSIMPSON w/ <br />ROOF SHEATHING SEE 1/S5 FOR (10) 10d <br />ATTACHED PER Y ADDITIONAL SEE PLAN FOR NAILS AT BASE & SIMPSON <br />Y 8d NAILS AT VALLEY TRUSS <br />NAILING SCHEDULE OUTLOOKER SP2 w/ (12) 10d NAILS AT TOP <br />4" O.C. INFO. <br />2x4 #2 SPF BRACING @ EXTERIOR SHEATHING INFO. <br />16" O.C. W/ (4) 12d COMMON TRUSSES. ATTACHED PER 2x BLOCKING BETWEEN STUDS <br />TOENAILS TO TOP —�/��— SEE TRUSS PLAN 2X4 STUDS w/ SIMPSON NAILING SCHEDULE TO TRUSS W/ (2) 12d TOENAILS <br />PLATE & (2) 12d END MIN. (2) 2x4 FOR CONNECTION SP1 w/ (10) 10d NAILS h EACH END (BETWEEN TRUSSES <br />STRUCTURAL SHEATHING p <br />ATTACHED PER NAILING NAILS TO TRUSS SPF TOP INFORMATION. AT BASE SEE J/S6 FOR <br />BOTTOM CHORD GABLE LOW ROOF/WALL S D) NAILS TO EACH VERTICAL <br />SCHEDULE PLATE MORE INFO. TRUSS STUD) <br />SHEATHING ATTACHED ; <br />VARIES SEE PLAN PER NAILING SCHEDULE 2x BASE PLATE W/ (2) 12d <br />VARIES W/ -- 2x4 BASE PLATE W/ NAILS @ 16" O.C. ALONG W/ <br />ROOF SLOPE FOR WALL LOCATION 1/2 PLYWOOD 1. SIMPSON MTS12 w/ (14) 10d x <br />SIMPSON LSTA30 w/ <br />(22) 10d NAILS OR (2) 16d NAILS TO , r� 1 1/2" NAILS TO BLOCKING <br />SIMPSON MTS12 w/ EACH COMMON BELOW 16" O.C. <br />WOOD WALL TRUSS/ FRAMING @ <br />MIN. 2X4 #2 SPF STUDS @ (14) 10d x 1 1/2" NAILS y / <br />OR TRUSS. 2X4 CONT. W/ (2) — ,� TYP TOP & BOTTOM l 1 <br />SEE PLAN 16d COMMONS 16 L.C. W/ EXTERIOR BE FLOOR GIRDER r,- <br />NAILS EACH ti SHEATHING ATTACHED BELOW @ 16" O.C. 1 > l�(Y,(\ - <br />STUD TYP. T&B PER NAILING SCHEDULE & <br />(3) 12d TOENAILS TO • MASONRY WALL BELOW: SIMPSON � <br />SEE PLAN FOR PLATE BELOW ° HETA16 w/ (9) 10d x 1 1/2" NAILS @ FLOORING <br />TRUSS OR MASONRY WALL 4'-0" O.C. TO GABLE TRUSS <br />ROOF SYSTEM TOP OF WALL ; OR BEAM • BEAM BELOW: SIMPSON HTS20 w/ <br />SEE TRUSS PLAN a 24 lOd x 1 1/2" NAILS 4'-0" O.C. <br />MIN. 2X4 #2 SYP P.T. PLATE 16" FLOOR SYSTEM FLOOR GIRDER ° ( ) @ (2) 2x6 BLO W/ 1/2"X8" EPDXY ANCHOR SEE PLAN FOR SEE PLAN FOR TO GABLE TRUSS LOW ROOF TRUSS W/ CKING UNDER FLOOR G.T. <br />MASONRY WALL SEE @ 3" FROM EACH END & DIRECTION CONNECTION COMMON TRUSS RAISED BOTTOM CHORD 2nd FLOOR WALL w/ SEE PLAN <br />PLAN FOR MORE 16" O.C. MAX. �° SEE ROOF PLAN <br />EXTENSION SEE TRUSS SIMPSON LUS24-2 w/ (16) <br />SHEAR TRANSFER INFO. SECTION @ FLOOR FOR CONNECTION CONNECTIONS TO G.T. 16d NAILS AT EACH END <br />EXTERIOR. WALL 7 SECTION ENTRY 8 CONNECTIONK*�22 SECTION AT HIP GABLErj_2`�SECTION BUMP OUT 39 <br />SCALE:NTS SCALE:NTS SCALE:NTS SCALE:NTS <br />SCALE: NTS <br />DETAILS & SECTIONS <br />N <br />> O <br />r O <br />cm <br />o <br />-_' <br />0- CD X <br />N <br />M LL <br />O L <br />c 7- <br />(D <br />V ;_ Q <br />t !. r <br />_41e <br />o <br />U <br />U N <br />f Q-0 <br />E 1= <br />(n O O <br />< C: U :T <br />~ In " V <br />>>CL �W <br />`. ;S E <br />— j • r J` <br />, N 1�1F <br />_; <br /><� 04 Q <br />= <br />- <br />< <br />. z <br />`yo <br />' <br />F <br />A1*?OF <br />E SS`O�`,,\�,�� <br />��''nlrtlllt�il�`,�• <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />4 <br />w <br />0v E <br />LL <br />0 <br />n� <br />0 <br />M 0 ik Q LL <br />a <br />6 -'Q Lu <br />J LLB S d <br />W��n <br />Z <br />m e a 013 <br />� <br />W <br />� °� � 5 <br />04 �0c <br />U) m W <br />Z <br />W <br />0 <br />CID M Z Q J <br />N <br />Z <br />OU J <br />r'i W <br />❑�❑ <br />z N <br />z � S <br />z <br />� <br />Q <br />J <br />a <br />0 <br />Nto <br />z <br />C1 <br />0 <br />+� <br />J <br />O <br />W S <br />ulun <br />C y <br />ra <br />� <br />= <br />� in <br />w J <br />I <br />_. <br />U o 0 <br />Q N 0 <br />• <br />CO <br />C13 <br />Cl)< <br />z < <br />o <br />z <br />U_ <br />� <br />E <br />¢ <br />zo <br />2o <br />� <br />aR <br />n <br />E OV <br />o <br />z® <br />a <br />_ <br />VO <br />Q <br />O0 <br />z <br />� <br />o <br />N � <br />a= <br />o <br />az <br />�w <br />d i <br />I <br />¢moo <br />x <br />mo <br />O <br />='z <br />z <br />J <br />0 <br /><w <br />cq <br />�, 3 <br />F <br />2< <br />z z <br />Z <br />g° <br />a <br />w <br />W <br />o_ 3 <br />w0 <br />j � <br />m <br />F r <br />jT <br />w z w <br />w< <br />;0 <br />O <br />CD <br />d r <br />0 <br />0 <br />= <br />tll <br />> Cfl <br />0 <br />6 <br />2 <br />F— <br />L00 <br />cc C <br />�-- <br />_11 <br />T <br />m <br />T <br />� <br />N <br />¢I <br />cV <br />cV <br />Ln <br />CN <br />f <br />� <br />T <br />E <br />r <br />Z <br />ccz <br />Z <br />E T <br />y <br />N <br />v <br />c <br />a <br />E <br />U <br />ai <br />Q p <br />JOB <br />NO: <br />22-04746 <br />SCALE: <br />AS NOTED <br />SHEET NO. <br />D 1 <br />