PLUMBING LE6END
<br />SANITARY, WASTE BELOW FLOOR -5, W, SAN, 55
<br />SANITARY, WASTE ABOVE FLOOR - 5, W, SAN, 55
<br />STORM BELOW FLOOR - ST
<br />STORM ABOVE FLOOR - 5T
<br />- - - - - VENT PIPING - V
<br />GOLD WATER PIPING - GW
<br />- - - HOT WATER PIPING - HW
<br />- - - - - HOT WATER RETURN PIPING - HWR
<br />PIPING BELOW FLOOR - B/F
<br />-
<br />EXISTING GW
<br />- - -
<br />EXISTING HW
<br />- - - - -
<br />EXISTING HWR
<br />EXISTING PIPING
<br />PIPING TO BE REMOVED OR ABANDONED
<br />---II -O
<br />GLEANOUT5 - GO, WGO, FGO, GCO
<br />--D4-
<br />GATE VALVE - GV
<br />r
<br />BALL VALVE - BV
<br />-
<br />PRE55U E REDUCING VALVE - PRY
<br />-ham
<br />CHECK VALVE
<br />M
<br />CIRCUIT SETTER
<br />-1-
<br />GIRGUIT SETTER ASSEMBLY
<br />® a
<br />FLOOR DRAIN - FD, FD-*
<br />® 13
<br />AREA DRAIN - AD, AD-*
<br />®
<br />ROOF DRAIN - RD, RD-*
<br />WHA
<br />WATER HAMMER ARRESTOR
<br />VTR
<br />VENT THRU ROOF
<br />W-0
<br />WATER HEATER
<br />P-*
<br />PLUMBING FIXTURE
<br />0
<br />IN -LINE BAGKFLOW PREVENTER
<br />�-o-
<br />TRAP PRIMER - TP
<br />$
<br />AIR ADMITTANCE VALVE (AAV)
<br />ADA GOMPL I ANGE
<br />1. VERIFY FIXTURES THAT ARE INTENDED FOR HANDICAP USE WITH
<br />GURRENT ARCHITECTURAL DRAWINGS.
<br />2. PLUMBING FIXTURES DE51 GNATED FOR HANDICAP USE SHALL COMPLY
<br />WITH ADA AND ALL STATE, CITY, AND LOCAL REQUIREMENTS
<br />PERTAINING TO HANDICAP ACCESSIBILITY.
<br />3. FIXTURE INSTALLATION SHALL COMPLY WITH ADA AND ANY STATE,
<br />CITY, AND LOCAL REQUIREMENTS PERTAINING TO HANDICAP
<br />ACCESSIBILITY.
<br />4. THE CONTRACTOR SHALL BE RE5PON51BLE FOR COMPLYING WITH
<br />ADA AND ALL STATE, CITY, AND LOCAL REQUIREMENTS PERTAINING TO
<br />PLUMBING FIXTURE5 AND PLUMBING FIXTURE INSTALLATION FOR USE
<br />BY THE HANDICAPPED.
<br />SPRINKLER HEAD NOTES
<br />I. LAY -IN TILE CEILINGS:
<br />SMALL FRAME GLASS ELEMENT, 5EMI-RECE55ED QUICK RESPONSE
<br />PENDENT SPRINKLERS. TEMPERATURE RATING SHALL BE 1550-1650.
<br />SPRINKLER AND ESCUTCHEON SHALL BE POL 15HED CHROME.
<br />2. GYP CEILINGS:
<br />QUICK RESPONSE CONGEALED SPRINKLER. COORDINATE COVER
<br />FINISH WITH ARCHITECT. TEMPERATURE RATING SHALL BE 1550-1650.
<br />3. NO CEILING:
<br />SMALL FRAME GLASS ELEMENT, UPRIGHT QUICK RESPONSE PENDENT
<br />SPRINKLERS. TEMPERATURE RATING SHALL BE 1650 UNLE55 HIGHER 15
<br />REQUIRED. SPRINKLER SHALL BE ROUGH BRA55 FINISH.
<br />FLUMBIN6 FIXTURE SGHEDULE
<br />MARK
<br />DESCRIPTION
<br />MANUFACTURER,
<br />FITTINGS/AGGE550RIE5
<br />REMARKS
<br />FIXTURE CONNECTIONS
<br />MODEL NUMBER
<br />GW
<br />HW
<br />WASTE
<br />VENT
<br />WATER GL05ET
<br />AMERICAN STANDARD
<br />P-IA
<br />ELONGATED, TANK TYPE
<br />2467.016
<br />SEAT: CHURCH #g500C
<br />I.6 GPF, ELONGATED, PRESSURE ASSISTED, ADA
<br />1/2"
<br />--
<br />4"
<br />2"
<br />ADA
<br />CADET
<br />LAVATORY
<br />AMERICAN STANDARD
<br />FAUCET: DELTA 252q-HOF
<br />HALL HUNG, 4" CENTERS, WRI5T BLADES, ADA,
<br />P-3A
<br />WALL HUNG
<br />0355.012
<br />P-TRAP, DRAIN RISER 4 WATER SUPPLY SHALL BE PVC,
<br />JAY R. SMITH 0723 LAVATORY SUPPORT
<br />1/2
<br />1/2
<br />1-1/4
<br />1-1/211
<br />ADA
<br />LUCERNE
<br />GRID DRAIN, TRUEBRO LAV GUARD OR LAV SHIELD
<br />LAVATORY
<br />AMERICAN STANDARD
<br />FAUCET: DELTA/CAMBRIDGE 2-IC 425
<br />WALL HUNG 4" CENTERS 6" WRIST BLADES LAMINAR FLOW, ADA
<br />P-35
<br />WALL HUNG
<br />0355.012
<br />P-TRAP, DRAIN R15M 4 WATER SUPPLY SHALL BE PVC,
<br />6 DIA. GOOSENECK BEND, JAY R SMITH 0723 LAVATORY SUPPORT
<br />1/2"
<br />1/2"
<br />1-1/4"
<br />1-1/2"
<br />ADA
<br />LUCERNE
<br />GRID DRAIN, TRUEBRO LAV GUARD OR LAV SHIELD
<br />P-3G
<br />COUNTERTOP
<br />FAUCET: CHICAGO FAUGET5 201-AGN8AE2q-317CP
<br />P-TRAP, DRAIN RISER 8 WATER SUPPLY SHALL BE PVG
<br />4" CENTERS, 6" WRIST BLADES, b" DIA. GOOSENECK BEND,
<br />1/2"
<br />1/2"
<br />1-1/4"
<br />1-1/2"
<br />SINK
<br />DEL IOC
<br />-
<br />PLASTIC STRAINER, TRUEBRO LAV GUARD
<br />LAMINAR FLOW
<br />COUNTERTOP
<br />FAUCET: DELTA 440-DST
<br />P-3F
<br />SINK
<br />''T
<br />SL-ADA-2122-A-GR
<br />P-TRAP, DRAIN RISER 4 WATER SUPPLY SHALL BE PVC
<br />51NGLE LEVER FAUCET, ADA, 6-1/2" BOWL DEPTH
<br />1/2"
<br />1/2"
<br />1-1/4"
<br />1-1/2"
<br />ADA
<br />STRAINER, TRUEBRO LAV GUARD OR BA51N GUARD
<br />P-36
<br />SERVICE SINK
<br />16 Ufl! E
<br />WALL HUNG MOUNTING KIT
<br />R.O. WATER ONLY
<br />--
<br />--
<br />1-1/4"
<br />1-1/2"
<br />P-3H
<br />COUNTERTOP
<br />MUSTS
<br />FAUGET: DELTA/CAMBRIDGE 27C4425
<br />P-TRAP, DRAIN R15M 4 WATER SUPPLY SHALL BE PVG
<br />4" CENTERS, 6" WRIST BLADES, 6" DIA. GOOSENECK BEND,
<br />1/2"
<br />1/2"
<br />1-1/4"
<br />1-1/2"
<br />SINK
<br />MODEL II
<br />PLASTIC STRAINER, TRUEBRO LAV GUARD
<br />LAMINAR FLOW
<br />LAVATORY
<br />AMERICAN STANDARD
<br />FAUCET: SLOAN ETF-770-4 SENSOR-GONTROLLED
<br />WALL HUNG, LAMINAR FLOW, ADA, JAY R SMITH 0-123 LAVATORY
<br />P-3J
<br />WALL HUNG
<br />0355.012
<br />P-TRAP, DRAIN R15M 4 WATER SUPPLY SHALL BE PVC,
<br />SUPPORT, 120V HARD WIRED KIT W/ TRANSFORMER, WIRE AND TMV
<br />1/2"
<br />1/2"
<br />1-1/4"
<br />1-1/2"
<br />ADA
<br />LUCERNE
<br />GRID DRAIN, TRUEBRO LAV GUARD OR LAV SHIELD
<br />INSTALLED OUT OF SIGHT WITH MEANS OF ACCE55. WATER TEMP 1050F.
<br />MOULDED
<br />WIL50NART BVI514
<br />FAUCET: CHICA60 FAUCETS 201-AGNbAE2q-317CP
<br />4" CENTERS, 6" WRIST BLADES, 6" DIA. GOOSENECK BEND,
<br />P-3L
<br />SINK
<br />(NO EXCEPTIONS)
<br />P-TRAP, DRAIN RISER d WATER SUPPLY SHALL BE PVC,
<br />LAMINAR FLOW, COUNTERTOP -MOUNTED FAUCET, ADA
<br />I/2"
<br />I/2"
<br />I-I/4"
<br />I-I/2"
<br />PLASTIC STRAINER, TRUEBRO LAV GUARD
<br />FAUCET: MU5TEE 63bOOA
<br />P-4
<br />SINK
<br />��
<br />H05E 4 H05E HOLDER: MU5TEE 65.700
<br />-
<br />1/2"
<br />1/2"
<br />2"
<br />1-1/2"
<br />MOP HANGER: MU5TEE 65.600
<br />P_5
<br />EYE
<br />GUARDIAN
<br />WALL MOUNTED, THERMOSTATIC MIXING VALVE IN WALL
<br />STAY OPEN VALVE, SPRAY HEAD DUST COVERS. WATER TEMP qO'F.
<br />1/2"
<br />1/2"
<br />--
<br />--
<br />WASH
<br />65014
<br />WITH AGCE55 COVER. COORDINATE WITH ARCH.
<br />5HALL MEET AN51 Z358.1 AND A55E 1071 STANDARDS.
<br />DRINKING
<br />OA515
<br />P-b
<br />FOUNTAIN
<br />P6AG5L
<br />KA-L MOUNTED
<br />ADA COMPLIANT HI/LOW
<br />1/2"
<br />--
<br />1-1/2"
<br />1-1/2"
<br />ADA
<br />EYE
<br />�GI84�
<br />WALL MOUNTED, TRUEBRO LAV GUARD M.
<br />STAY OPEN VALVE, SPRAY HEAD DUST COVERS. HATER TEMP q0'F.
<br />P-8
<br />AS 1
<br />THERM05TATIG MIXING VALVE IN WALL WITH ACCESS
<br />LOCATE DRAIN TRAP IN51DE WALL. MODIFY TRAP INSULATION TO FIT.
<br />1/2"
<br />1/2"
<br />1-1/4"
<br />1-1/2"
<br />COVER COORDINATE WITH ARGH.
<br />SHALL MEET ANSI Z358.1 AND A55E 1071 STANDARDS.
<br />F5-2
<br />FLOOR SINK
<br />JR5 PRODUCTS
<br />_
<br />PLASTIC 1/2 GRATE
<br />--
<br />--
<br />4"
<br />211
<br />3024104
<br />TOP OF GRATE SHALL BE FLUSH WITH FINISHED FLOOR.
<br />FD-I
<br />FLOOR DRAIN
<br />JAY R SMITH
<br />_
<br />NIGKLE BRONZE STAINER TOP AND TRAP PRIMER INLET
<br />I/2"
<br />--
<br />3"
<br />2"
<br />2010
<br />TAILPIECE MOUNTED TRAP PRIMERS ARE NOT ACCEPTABLE.
<br />FD-2
<br />FLOOR DRAIN
<br />JR5 PRODUCTS
<br />PLASTIC SEDIMENT BUCKET
<br />PLASTIC FULL GRATE
<br />1/2"
<br />--
<br />3"
<br />2"
<br />2254103
<br />TAILPIECE MOUNTED TRAP PRIMERS ARE NOT ACCEPTABLE.
<br />TD
<br />TRENCH DRAIN
<br />JAY R SMITH
<br />g870-4c12 RE51N COMPO51TE GRATE - HEAVY DUTY
<br />TRENCH DRAIN TO EXTEND FULL LENGTH OF OPENIN66.
<br />1/2"
<br />--
<br />3"
<br />2"
<br />g814
<br />TRAP PRIMER INLET.
<br />GB
<br />EQUIPMENT
<br />ATEY
<br />BACKFLOW PREVENTER, THERMOSTATIC MIXING VALVE
<br />-
<br />1/2"
<br />1/2"
<br />2"
<br />" 2
<br />CONNECTION BOX
<br />HB
<br />H05E BIBS
<br />MODEL MDFORD
<br />VACUUM BREAKER
<br />-
<br />5/4"
<br />--
<br />--
<br />--
<br />AAV
<br />AIR
<br />ADMITTANCE
<br />IPS CORPORATION
<br />5TUDOR GHEM VENT
<br />RE-GE55M BOX WITH MA5TERFLOW RL5G3 LOUVERED
<br />-
<br />--
<br />--
<br />--
<br />--
<br />VALVE
<br />(NO EXCEPTIONS)
<br />GRILL
<br />ELEGTR I G NATER
<br />HEATER SGHEDULE
<br />RECOVERY
<br />MARK
<br />MANUFACTURER/MODEL
<br />STORAGE
<br />® 70 DEG.
<br />KW
<br />INLET/OUTLET
<br />ELECTRICAL
<br />REMARKS
<br />TEMP. RISE
<br />WH-1
<br />A.O. SMITH D5E-40
<br />40 GAL
<br />70
<br />12.0
<br />3/4"
<br />GOORD'
<br />EXPANSION TANK: WATTS PLT-5
<br />W/ELEC.
<br />MAXIMUM WATER TEMP: 120'F
<br />NOTE : WATER HEATERS MAY BE SUBJECT TO BOILER INSPECTION AND GERTIFIGATION REGULATIONS PER STATE OR LOCAL REQUIREMENTS. CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY
<br />INSPECTIONS AS PART OF H15 CONTRACT AND INFORM THE OWNER OF SUCH REQUIREMENTS FOR SUBSEQUENT PERIODIC, INSPECTIONS.
<br />PUMP SGHEDULE
<br />PUMP
<br />GPM
<br />HEAD
<br />TYPE
<br />SERVICE
<br />MANUF
<br />MODEL
<br />IIUMREMARKS
<br />MOTOR
<br />EFFICIENCY
<br />NOM. HP
<br />VOLT -PH
<br />RPM
<br />GP -I
<br />5
<br />q
<br />VERTAN-LINE
<br />WH-2
<br />TACO
<br />006-BT
<br />-
<br />1/40
<br />GOORD.
<br />W/ELEG.
<br />3250
<br />NOTES -FIRE PROTEGT I Oil
<br />I. THE FIRE PROTECTION 5Y5TEM AND INSTALLATION SHALL MEET ALL REQUIREMENTS OF NFPA
<br />15, LOCAL APPLICABLE CODES AND THE OWNER'S UNDERWRITER.
<br />2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR REVIEW PRIOR TO
<br />ORDERING OR PURCHASING ANY FIRE PROTECTION EQUIPMENT. SUBMITTALS SHALL CONTAIN
<br />SPRINKLER DRAWINGS, CALCULATIONS, MATERIALS AND ACCESSORIES. DRAWINGS SHALL BE
<br />STAMPED WITH A REGISTERED ENGINEER'S SEAL OR EQUIVALENT CONTRACTOR'S SPRINKLER
<br />CERTIFICATE SEAL. DRAWINGS SHALL BE 1/6" SCALE MINIMUM.
<br />3. THE GONTRAGTOR SHALL FIELD VERIFY THE EXACT LOCATION AND SIZE OF EXISTING
<br />RELATED UTILITIES PRIOR TO COMMENCEMENT OF WORK. SYSTEM DE516N SHALL BE BASED
<br />ON AVAILABLE WATER CHARACTERISTICS. FIELD VERIFY ADEQUACY OF EXISTING SYSTEM.
<br />4. GALGULATION5 SHALL ALLOW FOR INSIDE AND OUTSIDE H05E STREAMS.
<br />5. ALL PENETRATIONS THROUGH FIRE AND SMOKE RATED ASSEMBLIES SHALL BE FIRE STOPPED
<br />AS REQUIRED.
<br />6. ALL FIRE PROTECTION SYSTEMS AND INTEGRAL EQUIPMENT SHALL BE GUARANTEED FOR A
<br />MINIMUM OF ONE YEAR.
<br />7. ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS SHALL BE COORDINATED WITH THE
<br />ELECTRICAL DRAWINGS.
<br />8. THE CONTRACTOR SHALL FULLY GOORD I NATE SPACE REQUIREMENTS WITH EACH D 15G I PL I NE
<br />PRIOR TO INSTALLATION OF THE FIRE PROTECTION SYSTEM.
<br />q. ALL PIPING SHALL BE PROPERLY SUPPORTED BY THE BUILDING STRUCTURE. PIPE SHALL
<br />NOT REST ON TILES OR OTHER GEILING STRUCTURES.
<br />10. SPRINKLERS INSTALLED IN LAY -IN TILE GE I L I NG5 SHALL BE INSTALLED AT CENTER POINTS
<br />IN THE CEILING TILES OR INSTALLED ON QUARTER POINTS OF THE FOUR FOOT DIMENSIONS
<br />OF 2'x4' GEILING TILES.
<br />11. THE CONTRACTOR SHALL FURNISH AND INSTALL A GABINET LOCATED IN THE FIRE SERVICE
<br />ROOM WITH THE SPARE NUMBER OF EACH TYPE SPRINKLER AND RELATED WRENGH AS
<br />REQU I RED BY NFPA 13.
<br />PLUMBI NCB SPEG I F I GATI ONS
<br />AND MOTES
<br />I. ALL PLUMBING WORK SHALL COMPLY WITH THE FLORIDA PLUMBING CODE WITH ALL APPLICABLE LOCAL
<br />AMENDMENTS.
<br />2. PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
<br />CONDITIONS, PIPING SIZES AND LOCATIONS, EQUIPMENT, ETG., SHOWN ON THE DRAWINGS OR AFFECTING THIS WORK
<br />AND SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT.
<br />3. FIELD VERIFY LOCATION OF EXISTING 5ERVIGE5 TO BE REUSED OR CONNECTED TO AND REPORT TO
<br />ARCHITECT/ENGINEER IF OTHER THAN THAT WHICH 15 INDICATED ON DRAWINGS.
<br />4. WHEN RENOVATING OR MAKING AN ADDITION TO AN EXISTING FACILITY, CONTRACTOR SHALL FIELD VERIFY
<br />EXISTING EQUIPMENT (FIXTURES, TRIM, PUMPS, ETC) MANUFACTURERS AND USE SAME MANUFACTURER5 FOR NEW
<br />EQUIPMENT. CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL OF OWNER/OWNER REPRESENTATIVE FOR USE OF
<br />DIFFERENT MANUFACTURERS.
<br />5. ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT 15 D 15TUR13ED DURING THE GOUR5E OF THE WORK SHALL
<br />BE REPAIRED. WHEREVER FOUNDATION WALLS, OUTSIDE WALLS, ROOFS, ETC., ARE PENETRATED FOR INSTALLATION
<br />OF SYSTEMS, THEY SHALL BE PATCHED TO MATCH EXISTING CONSTRUGTION AND SEALED WEATHER TIGHT.
<br />6. ALL OPENINGS IN DRAINAGE AND/OR VENT SY5TEM5 A5 A RESULT OF INSTALLATION ROUGH -IN SHALL BE
<br />PROTECTED WITH A TEST PLUG THAT 15 SECURELY LOCKED IN PLACE UNTIL FINAL FINISHED CONNECTIONS ARE
<br />INSTALLED.
<br />7. ALL PIPING SHALL BE RUN PARALLEL TO BUILDING LINE-5 AND SUPPORTED AND ANCHORED AS REQUIRED TO
<br />FACILITATE EXPANSION AND CONTRACTION. INSTALL ALL PIPING AS REQUIRED TO MEET CONSTRUCTION CONDITIONS
<br />AND TO ALLOW FOR INSTALLATION OF OTHER WORK, INCLUDING DUCTWORK AND El EGTRIGAL CONDUIT.
<br />8. ALL PIPING SHALL BE ROUTED ABOVE GEILING, CONGEALED IN WALLS, AND BEHIND FURNISHINGS UNLESS OTHERWISE
<br />INDICATED. ALL OVERHEAD PIPING EXPOSED TO VIEW SHALL BE ROUTED AS HIGH A5 P0551BLE AND TIGHT TO THE
<br />UNDERSIDE OF STRUCTURE.
<br />q. WATER PIPING ROUTED ABOVE CEILINGS AND IN EXTERIOR WALLS SHALL BE ROUTED ON HEATED SIDE OF CEILING
<br />INSULATION AND WALL INSULATION, UNLE55 OTHER FREEZE PROTECTION 15 INDICATED.
<br />10. SANITARY WASTE 4 VENT, AND STORM DRAIN PIPING ABOVE GROUND SHALL BE PVG WITH SOLVENT JOINTS.
<br />11. SANITARY WASTE 4 STORM DRAIN PIPING BELOW GROUND SHALL BE SCHEDULE 40 DWV PVC, WITH SOLVENT JOINTS.
<br />12. PROVIDE GLEANOUT5 AT THE END OF EACH HORIZONTAL SANITARY RUN AND AT THE BASE OF ALL SANITARY
<br />STACKS. GLEANOUT5 SHALL BE OF THE SAME 51ZE AS THE PIPES THEY SERVE.
<br />13. TOPS OF ALL FLOOR DRAINS AND GLEANOUT5 SHALL BE SET FLUSH WITH AJDAGENT FINISHED FLOOR. COORDINATE
<br />FLOOR SLOPES AND DRAIN LEVELS WITH ARCHITECTURAL. GAULK WITH GONTINUOU5 CLEAR SEALANT BAND.
<br />14. AIR ADMITTANCE VALVES SHALL BE INSTALLED ONLY WHERE SHOWN ON PLANS AND SHALL BE 5TUDOR GHEM-VENT
<br />OR APPROVED EQUAL.
<br />15. ALL SANITARY WASTE, VENT, AND DOMESTIC WATER PIPING 5Y5TEM5 SHALL BE TESTED IN ACCORDANCE WITH
<br />SECTION 512 OF THE CURRENTLY ACCEPTED INTERNATIONAL PLUMBING CODE, OR OTHER APPLICABLE LOCALLY
<br />ACCEPTED CODE.
<br />16. GOLD AND HOT WATER PIPING ABOVE GRADE SHALL BE TYPE L HARD DRAWN COPPER TUBING CONFORMING TO
<br />A5TM 8-88 WITH SWEAT JOINTS AND CAST OR WROUGHT FITTINGS. JOINTS SHALL BE MADE WITH LEAD FREE
<br />SOLDER. GOLD WATER PIPING BELOW GRADE SHALL BE TYPE K COPPER TUBING WITH CAST OR WROUGHT FITTINGS
<br />AND JOINTS AS DE5GRIBED ABOVE. JOINTS SHALL NOT BE PERMITTED UNDER FLOOR SLABS. WATER PIPING
<br />BELOW GRADE THROUGH CONCRETE SHALL BE PROTECTED WITH PLASTIC SLEEVES.
<br />17. ALL HOT, GOLD, AND HOT WATER RETURN WATER PIPING ABOVE GRADE SHALL BE INSULATED WITH ONE INCH
<br />NOMINAL THICKNESS FIBERGLASS PIPE INSULATION WITH VAPOR BARRIER JACKET, OWEN5-GORNIN6 A5J/SSLII OR
<br />EQUAL. ENDS OF INSULATION SHALL BE TAPED AT ALL FITTINGS. INSULATION SHALL BE CONTINUOUS THROUGHOUT
<br />EXCEPT WHERE PENETRATING A FIRE BARRIER.
<br />16. WASTE, GOLD WATER PIPING AND HOT WATER PIPING AT HANDICAPPED LAVATORIES SHALL BE INSULATED WITH
<br />TRUEBRO LAV GUARD, LAV SHIELD, OR BASIN SHIELD ENGLO5URE5/P1PE GOVER5 OR APPROVED EQUAL.
<br />Iq. EXPOSED TRIM PIPING TO ALL SINKS AND LAVATORIES, INCLUDING GW, HW, DRAIN, AND DRAIN TRAPS, SHALL BE
<br />PVC WITH PVC E5GUTGHEON5 AT WALL PENETRATION. ALL EXPOSED PIPING TO OTHER FIXTURES SHALL BE
<br />INSTALLED PER 5PECIFIGATION5 WITH ESCUTCHEONS. ALL OTHER PIPING PENETRATING CEILINGS, WALLS, AND
<br />GA5EWORK SHALL BE INSTALLED WITH MATCHING E5GUTGHEON5 AT THE PENETRATION. ALL PIPING PENETRATING
<br />EXTERIOR WALLS AND ROOFS SHALL BE FLASHED AND SEALED IN AN APPROVED WEATHER TIGHT MANNER AND
<br />SHALL BE PROTECTED AS REQUIRED BY THE ARCHITECT.
<br />20. SLEEVE OR GORE -DRILL FLOOR SLABS, WALLS, ETC., AS REQUIRED FOR PIPING AND FIRE -STOP MATERIAL AROUND
<br />PIPE. VERIFY LOCATION OF STRUG- URAI_ BEAMS, JOI5T5, ETC. BEFORE DRILLING.
<br />21. ALL PIPING TO HAVE IDENTITY MARKER5/LA5EL5 LOCATED EVERY 15 FEET ON LONG RUNS, AT EVERY CHANGE OF
<br />DIRECTION AND AT ALL WALL PEt ETRATION5.
<br />22. PROVIDE AN ISOLATING, DIELECTRIC UNION AT ALL CONNECTIONS BETWEEN FERROUS AND NONFERROUS PIPING.
<br />23. COORDINATE LOCATIONS OF FLOOR DRAINS IN MECHANICAL ROOMS WITH MECHANICAL EQUIPMENT.
<br />24. COORDINATE FIXTURE TYPES WITH THE ARCHITECTURAL DRAWINGS. AREAS DESIGNATED FOR USE BY THE
<br />HANDIGAPPED SHALL BE SUPPLIED WITH FIXTURES AND TRIM AS SET FORTH IN THE "AMERIGAN5 WITH DISABILITIES
<br />AGT"(ADA).
<br />25. ROUTE RELIEF VALVE DISCHARGE FROM WATER HEATER TO NEAREST AVAILABLE DRAIN OR TO GRADE OUTDOORS.
<br />26. WHEN WATER HEATERS ARE PLACED ABOVE THE GEILING, THE CONTRACTOR SHALL PROVIDE A 1-1/2" P TRAP WITH
<br />A TRAP PRIMER AT THE NEAREST WASTE OR VENT LINE ABOVE THE CEILING FOR P8T DISCHARGE.
<br />27. FLOOR MOUNTED ELECTRIC AND SEALED COMBUSTION WATER HEATERS SHALL BE ELEVATED ON HIGH-IMPAGT
<br />PLASTIC EQUIPMENT PADS.
<br />28. ROUTE RELIEF VENTS ON ALL BAGKFLOW PREVENTER5 TO NEAREST FLOOR DRAIN OR CODE APPROVED DRAINAGE
<br />RECEPTACLE.
<br />2q. AGGE55 PANELS SHALL BE PROVIDED WHERE CONGEALED CONTROL DEVICES, VALVES, ETC. ARE CONGEALED
<br />WITHIN WALLS. WHERE ACCESS FOR ADJUSTMENT AND MAINTENANCE 15 P0551BLE THROUGH LAY -IN SUSPENDED
<br />GE I L I NGS, ACCESS PANELS ARE NOT REQU I RED.
<br />30. PROVIDE ALL FITTINGS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY TO FACILITATE FUNGTIONING OF THE
<br />COMPLETE PLUMBING SYSTEM AS INDICATED BY THE DESIGN AND THE EQUIPMENT INDICATED.
<br />51. CONTRACTOR SHALL COORDINATE El ECTRIGAL CHARACTERISTICS OF ALL PLUMBING EQUIPMENT WITH THE
<br />ELECTRICAL DRAWINGS PRIOR TO ORDERING ANY EQUIPMENT. ALL PLUMBING EQUIPMENT REQUIRING ELECTRICAL
<br />POWER SHALL BE INSTALLED WITH DISCONNECT 5WITGHE5 AT EACH PIECE OF EQUIPMENT. COORDINATE WITH THE
<br />El EGTRIGAL CONTRACTOR.
<br />32. ALL PLUMBING EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
<br />55. ALL PLUMBING EQUIPMENT AND 5YSTEM5 SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER
<br />SUBSTANTIAL COMPLETION.
<br />34. SHOP DRAWINGS SHALL BE SUBMITTED TO AND REVIEWED BY THE ARCHITECT PRIOR TO ORDERING EQUIPMENT OR
<br />INSTALLING ANY PIPING FOR ALL EQUIPMENT, FIXTURES, AND PIPING.
<br />55. APPROVED MANUFACTURERS:
<br />VITREOUS FIXTURES: AMERIGAN STANDARD, KOHLER, ZURN
<br />SOLID SURFACE SINKS (OTHER THAN REUSF�: MU5TEE
<br />STAINLESS STEEL SINKS: JUST, ELKAY, STERLING
<br />FAUCETS: DELTA, ZURN, 5YMMON5, GHIGAGO FAUCET, FIAT
<br />TUB/SHOWER VALVES: 5YMMON5
<br />TRIM: JAMECO, BRA556RAFT, MGGUIRE
<br />FLUSH VALVES: SLOAN, DELANEY, ZURN
<br />SEATS: BEMIS, BENEKE, CHURCH, OL50NITE (HEAVY DUTY ONLY)
<br />DRINKING FOUNTAINS: OASIS, ELKAY, HALSEY TAYLOR
<br />TUB/5HOWER ENCLOSURES: LA500, AQUAGLA55, AQUARIUS, AQUA BATH
<br />EMERGENCY FIXTURES: GUARDIAN, ACORN SAFETY, BRADLEY
<br />ADA INSULATION: TRUEBRO
<br />WATER HEATERS: A.O. SMITH, STATE, LOGHINVAR
<br />FLOOR DRAINS: JAY R. SMITH, ZURN, WADE, JO5AM, WATT5
<br />ROOF DRAINS: JAY R. SMITH, ZURN, WADE, J05AM, WATTS
<br />GLEANOUT5: JAY R. SMITH, ZURN, WADE, J05AM
<br />PR1RE REDUCING VALVE: WATT5, FEBGO, APOLLO
<br />BAGKFLOW PREVENTER: WATT5, FEBGO, APOLLO
<br />WALL HYDRANTS: WOODFORD, JAY R. SMITH, ZURN
<br />(0
<br />lA
<br />Y
<br />C
<br />L.
<br />O
<br />4-
<br />3
<br />.H
<br />4j
<br />L
<br />•r-I
<br />�,
<br />O
<br />"O
<br />C
<br />C
<br />fif
<br />z
<br />0
<br />O
<br />U
<br />0)
<br />U)
<br />C
<br />+�
<br />•1
<br />Co
<br />:3
<br />U
<br />L.Cl)
<br />a)
<br />O
<br />o
<br />C
<br />x
<br />^
<br />O
<br />N
<br />U
<br />ca
<br />O
<br />d
<br />G
<br />L.
<br />C
<br />L.
<br />_
<br />4�
<br />W
<br />O
<br />C
<br />e
<br />4-
<br />o
<br />.i
<br />m
<br />U
<br />-0
<br />-0
<br />IM sodn a .labs b:bb m v0d on er
<br />awgaehy M. = a t a=we/ d'' d2d
<br />d�
<br />IM ' --- b to onva of Kcc PKRW M I
<br />ad b not b be oopbd veapodooad In dhob
<br />b apao/b V crowabbddpvoja . R YtD db W
<br />U
<br />a--+
<br />U
<br />co
<br />U
<br />L
<br />Q
<br />co
<br />0
<br />M
<br />a
<br />� �
<br />Q
<br />H
<br />Cr
<br />00
<br />J
<br />O
<br />O
<br />O
<br />r
<br />O
<br />W
<br />0
<br />I--
<br />W
<br />N
<br />N
<br />0
<br />O
<br />co
<br />D
<br />Z
<br />Q
<br />M
<br />M
<br />X U
<br />V! In
<br />J
<br />H
<br />Q
<br />M
<br />O
<br />M
<br />N
<br />Q N
<br />M
<br />H
<br />Q
<br />N
<br />-
<br />X
<br />Q
<br />LL
<br />Z
<br />O_
<br />Q
<br />U
<br />O
<br />_1
<br />W
<br />r
<br />LO
<br />M
<br />0
<br />Q
<br />M
<br />v!
<br />Z
<br />J
<br />LL LL
<br />J
<br />Q
<br />m
<br />Q
<br />�-
<br />0
<br />Z
<br />-�
<br />Q
<br />W
<br />J
<br />W
<br />N
<br />Z
<br />T�
<br />1
<br />LLI
<br />N
<br />DRAWN BY:
<br />JSM
<br />DATE: 03/12/13
<br />PROJECT NO.1230
<br />REVISIONS
<br />REV.
<br />REV.
<br />R EV.
<br />Shepherd, Harvey & Associates, Inc.
<br />4855 River Green Parkway, Suite 400
<br />Duluth, Georgia 30096-2569 Fla. Cert. of Auth. No. 28961
<br />770-495-4007 FAX 770-495-7112 Project Number: 13-017
<br />Sheet No.
<br />P-1