My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3688 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
3688 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 10:17:22 AM
Creation date
2/18/2025 3:18:18 PM
Metadata
Fields
Template:
Building Plans
Street #
3688
Location
Garden Wall Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />B <br />(16) RISERS AT 7 -9116" <br />( `_ <br />10" TREADS w/ 3/4" NOSING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />i 6< <br />i 5 <br />�4 <br />ro <br />i12 <br />42" KNEE WALL WITH <br />1x8 CAP & CASING 1'10 <br />F <br />36" H. CONT. <br />B �� i8 <br />o <br />GRASPABLE i <br />UNDERGE <br />RAILING 7 <br />STAIRS <br />60 <br />6 1x TREAD <br />1x8 CAP & TYP. <br />� 5 <br />CASING ,4 1x RISERS <br />(3) 2x12 (TYP.) <br />3 <br />STRINGERS 2 iv 2x FRAMED <br />2x FRAMED <br />WALL <br />WALL <br />1 <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)-1/4"x 3 1/2" TAPCONS @ <br />16"o.c. AND 3" FROM EA. END. <br />SIN <br />T <br />SIN <br />CONT. HANDRAIL <br />42" KNEE WALL RETURN TO - <br />WITH 1x8 CAP <br />& CASING V1/A L L D E T�Al L <br />E <br />_!6__ DPLYWOOD ... - <br />DECKING <br />TYP. STAIR SECTION <br />SCALE: 1/4" = V-0" <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the dear width of the stair. <br />Nosing*: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '% inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handralls: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not lees than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 Inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, Including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />SEE PLAN FOR LANDING DEPTH L <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ EN[ <br />LANDING FOI <br />STRINGERS' <br />CONNECT TC <br />FLOOR SYSTEM <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA, SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1 /4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO._ <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />:A <br />1 <br />D2 <br />P. <br />@ <br />CONERS 0 Hl =H1 = <br />rn <br />OCn <br />= <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />J <br />S6 <br />TYP. <br />3 <br />SIM. w/ (1) <br />MSTAM36 <br />FLAT STRAP <br />DRYER VENT- <br />THRU ROOF. <br />HANSON BOX @ <br />36" A.F.F. <br />LAU N <br />8'-0" FLAT CLG. <br />TILE <br />IN <br />1 <br />TB 60" X 36" <br />- - SHOWER C- 164" <br />FIBERGLASS <br />SURROUND <br />3'-4" 111 - 5,_5„ r OWNER'S <br />-_ AFLAT TH 2168 SUITE <br />8'-0" FLAT CLG. iv <br />2068 TILE CARPET M <br />BF I - - --- LO- G.T. - - - <br />Co o <br />4SH 3 <br />D2 <br />R&S _ IF- -F l SIM. w/ (1) <br />r----- MSTAM36 <br />I (� r95 FLAT STRAP <br />WIC <br />In18'-0" FLAT CLG. 2068 <br />�I CARPET 2668 <br />TILE TO 7' o ?ss� CHASEcNv <br />A.F.F. <br />BEDROOM 3 <br />2 4SH ( 8'-0" FLAT CLG. <br />-0" T CLG. OTQ U) m CARPET <br />TILE 2468 I o8 IT <br />-TP i TB BF I 0 `n Q <br />5'-9" T-0" L T-3" <br />U) H3 <br />2668--- _ "' _ _ G.T. _ w= <br />T WNU <br />ilea V-T' 2'-4" 10'-4" 6 <br />+ I -2" 2668 1�70 I <br />I � <br />u- ,� - --- <br />J I D. m 42"HIGH 1/2 - <br />00 <br />1I I I I( I I I I I I I I I <br />w l � WALL WC/ <br />_m W. <br />I I I I I I I <br />DNI I I I 1 1 I I I I I I I 00 <br />I 116 I ! 14 113 112 111 110 I 9 18 I 16 15 !4 13 12 !1 c� <br />>c 24SH <br />00 <br />to <br />22 H 1 ! D2 <br />in I D 1 I <br />T-8" 8'-0" `n I I <br />Ak <br />I <br />4068 BF <br />I - I <br />BEDROOM 2 t ' <br />8'-0" FLAT CLG. 'I -am I I <br />CARPET Im I I <br />I I I <br />I <br />22 I I <br />D1 I I <br />to 4068 BF I I I <br />� I I <br />I------------i <br />I I <br />I <br />25 SH I <br />4 EGRESS 22 <br />I D2 B <br />I H1 D1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------- --------------------- -----------i <br />11 <br />:t <br />00 <br />60 <br />v <br />ir"UTii <br />RFV 1f1 1 ?f) CAR <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-TEND ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.' <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS" <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX254 <br />S.H. <br />13 <br />20X38J <br />18}X371 <br />S.H. <br />14 <br />20 X 50 1 <br />18 J X 50 <br />S.H. <br />15 <br />20X63 <br />18JX624 <br />S.H. <br />16 <br />20 X 72 <br />18 4 X 71 J <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 J <br />S.H. <br />1H3 <br />271/4X38 <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 1 <br />26 x 50 <br />S.H. <br />11-15 <br />27JX63 <br />26X621/2 <br />S.H. <br />11-16 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />361 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1 <br />36 J X 50 <br />S. H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 4 X 71 1/2 <br />S. H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 J <br />S. H. <br />33 <br />54 X 38 IJ <br />52 J X 37 J <br />S. H. <br />34 <br />54 X 50 J <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62,J <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 J <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 112" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />LVL 2.0E Fb=2950 <br />C(2) <br />- 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />RAG <br />(2) - 2X4 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />Follow Q/S4. See Plan for <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />(-A+29.7 <br />/ -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />�D <br />+28.3 / -37.0 <br />�E <br />+26.6 / -29.1 <br />QF <br />+26.6 / -33.5 <br />�G <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />SECOND FLOOR PLAN - B <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1 ST FLOOR LIVING AREA <br />2ND FLOOR LIVING AREA <br />721 S.F. <br />807 S.F. <br />TOTAL <br />GARAGE <br />LANAI <br />ENTRY <br />1528 S.F. <br />397 S.F. <br />60 S.F. <br />30 S.F. <br />TOTAL SQ. FT. <br />2015 S.F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />(GARAGE / LIVING) <br />R-11/R-13 KRAFT FACED <br />M <br />car <br />0 <br />N <br />tYf <br />IC-5 <br />a <br />d =o <br />m' <br />> W <br />CD = <br />ao <br />U. <br />ij.. <br />N <br />c�0- <br />N 10 O <br />N Z <br />�Xc <br />aI o- <br />y Eo r <br />co <br />CP <br />yam•`° >~ <br />a� <br />� E <br />re o <br />ci Q, <br />\\011���wo wtv <br />J O� N• <br />U <br />�O <br />•'• <br />t;F <br />•. L Off` ; <br />ROFEss\W4 <br />�\ <br />/e <br />//,f"hill if <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Resldential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seat. <br />LoN <br />CS C <br />ie <br />fA <br />N ao w <br />rllnr�� `F � <br />a <br />u a <br />x- <br />1 <br />gLLu' <br />-6 - a S2 <br />r4gG � o <br />W <br />(a): <br />I I - ;; <br />=co <br />unW <br />05 <br />MZ Q� <br />In <br />N <br />0 U <br />•Z <br />W <br />U <br />pp <br />z <br />a <br />v0 <br />- N <br />Z .9 <br />'U <br />o41 <br />0 <br />W <br />Ln <br />t� <br />c v <br />N <br />� <br />O <br />o <br />it <br />YO <br />qo® <br />g <br />T� <br />o <br />fcv <br />-M <br />z <br />oa <br />00 <br />Z <br />Z <br />4" t- <br /><om, <br />C <br />V <br />o <br />Y <br />W <br />Zp*U <br />d) <br />Jy� <br />4 <br />7 <br />U <br />O E <br />g <br />U <br />=L <br />W <br />�� <br />5 <br />02 <br />w <br />a <br />`_: <br />° <br />c � <br />LA <br />J <br />L6 <br />O <br />� <br />B <br />m <br />L0 <br />co <br />ca <br />0r-- <br />� <br />N <br />4 <br />L^ <br />i <br />LO <br />,� <br />M N <br />O <br />IUD0000 <br />N <br />t <br />` <br />CY) <br />f '^ <br />L / <br />co N <br />o <br />E Q <br />f/1 <br />N <br />= <br />a <br />E <br />U -J <br />Q O <br />JOB <br />NO: <br />22-12354 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.