Laserfiche WebLink
3 <br />ELECTRICAL SPECIFICATION <br />150AI2 INDOOR <br />PANEL <br />L CENTER <br />NOTES: <br />01 a14 to rights a outlets <br />NEMA 1 <br />10 a12 to appliances and GFI <br />ELECTRICAL CONTRACTOR <br />150AMP' <br />top AMP <br />01 e10 to WH <br />MUST VERIFY WITH THE <br />10 as to Rsnue <br />SPECIFICATIONS FOR THE TYPE <br />10 ae to HVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />T <br />LOCATION PURPOSES.M-LIN <br />5o=tio <br />0 <br />200-4/0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconn <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />p4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed Within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed In <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PE7FW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I--O <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />D� <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />a 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. $ (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT, CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />11 <br />II <br />II <br />II <br />11 <br />3" <br />Ci <br />1.5" VTR III <br />I� <br />I <br />I <br />I <br />r. <br />� i I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR D <br />KITCHEN <br />DEDICATED <br />I RECEPTACLE <br />FOR MICROWAVE <br />IGFI RANGE HOOD <br />PER SPECS <br />37 11 <br />/ I I <br />01 II <br />OPTIONAL LIGHTING <br />SCALE: Y4"=1'-0" <br />if T T W - <br />j I <br />I I <br />r-----------1 <br />ROUGH -IN FOR.,19 I I <br />OPT. CLG. FAN/ I I <br />iLIGHT PRE -WIRED <br />I I <br />' BEDROOM 2 <br />I I <br />I I <br />I I I <br />I I I <br />I I I <br />I------------t <br />Eel <br />I <br />I <br />I <br />I I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I I <br />L.--------------------------------------J <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET — <br />r_^===_i <br />I I11 <br />I I ALT I I <br />I I AC PAD I I <br />I1 __11 <br />WP <br />GFI4i <br />DISC. <br />r <br />PER SPECS �, / <br />ELECTRICAL PLANS - B <br />SCALE: Y4"=1'-0" <br />C" <br />N <br />O <br />c•� <br />c+i <br />a ,o <br />c W <br />W t=. � = <br />C 10 V <br />fV <br />m <br />N 27 CIAt <br />to 67 p .� <br />c >, E <br />c <br />c <br />� • °>' u Aa7 <br />c i` <br />o <br />a v <br />w <br />SRO Way <br />• <br />S E <br />. \�, 67 N <br />N <br />'� <br />U '�44 WF gnu <br />Cj �Q <br />L ''� <br />�, <br />• <br />OFESStON�\`\���`�� <br />/i f///III Jill t110\0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />to <br />E <br />S N1 <br />�pp <br />CQD � N ar0 <br />0 5 to OD <br />u_ <br />di N 04 0 M J <br />Q U. <br />N Lt.lL W <br />Z13 <br />111111 O^i Oi 9 04 <br />Z 'n � Z d <br />cli LL <br />IL <br />z o �% 9 0 <br />W ❑❑ <br />z � <br />Q <br />J— <br />cl- <br />- <br />U <br />� <br />W <br />M � <br />U <br />O <br />uos <br />Cn <br />U <br />was - <br />fQj <br />�� <br />Q v <br />$ <br />�m <br />J <br />a EI <br />y <br />o <br />�a <br />S,Z <br />H <br />RU <br />Do. <br />U <br />E <br />o <br />0 <br />to <br />Z— <br />C"!ag <br />W� <br />OE <br />fO <br />°> <br />84 <br />'o <br />Wo <br />s <br />=� <br />O <br />�3 <br />1 : <br />g 3 <br />>0 <br />J <br />Ui <br />0 <br />rn <br />B <br />LLO <br />co <br />— <br />m <br />N <br />ate-+ <br />L O <br />N <br />� N <br />0) <br />Ul) <br />00 O <br />r <br />Q (D LC) <br />r <br />M <br />'^ CV) = <br />Y/ <br />o <br />to N <br />E y <br />1`0 <br />c <br />a <br />U q C) <br />JOB <br />NO : 22-12354 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />