Laserfiche WebLink
Y <br />�2 <br />i <br />U I_ HT N G PLAN <br />SO a._E: 1/4"=1'-0" <br />LIGHTING NOTES: <br />1. <br />PROVIDE A MIN. 50 FOOT— CANDLES OF LIGHT ON ALL WORKING SURFACES IN <br />THE <br />FOOD PREPARATION AREAS, EQUIPMENT AND UTENSIL WASHING AREAS, AT HAND WASHING <br />LAVATORIES, AND IN TOILET ROOMS. <br />2. <br />PROVIDE A MIN. 20 FOOT— CANDLES OF LIGHT AT A DISTANCE OF 30 INCHES <br />ABOVE <br />THE FLOOR IN WALK—IN COOLERS AND FREEZERS, DRY STORAGE AREAS, AND <br />IN ALL <br />OTHER AREAS. <br />3. <br />ALL LIGHTING FIXTURES AND LIGHT BULBS LOCATED WITHIN FOOD PREPARATION <br />AND <br />STORAGE AREAS SHALL BE SHIELD OR SHATTERPROOF. <br />4. <br />ALL THE EMERGENCY LIGHTS MUST BE CONNECTED TO NO SWITCHED LIGHTING <br />CIRCUIT. <br />5. <br />THE CONSTRUCTION DOCUMENTS SHALL SPECIFY THAT DOCUMENTS CERTIFYING <br />THAT THE <br />INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF <br />SECTION <br />C405 ARE TO PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE <br />DATE OF <br />RECEIPT OF THE CERTIFICATED OF OCCUPANCY. <br />6. <br />CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 30 DAYS AFTER THE <br />DATE OF <br />SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL <br />BE <br />PROVIDED TO THE BUILDING OWNER, INCLUDING: <br />— A SINGLE —LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND <br />— FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION. <br />PER <br />FBCE 405.6.4.1 <br />LIGHT FIXTURE SCHEDULE <br />QUAN <br />TITY <br />DSCRIPTION <br />STATUS <br />WATT <br />SYMBOL <br />2X4 LED TROFFER LIGHT, 120V, 18 <br />8 <br />WATT LAMP. 3500K <br />RELOCATED <br />54 <br />2X2 LED TROFFER LIGHT, 120V, 18 <br />WATT/LAMP. 3500K <br />NOT IN USE <br />36 <br />62 <br />6" RECESSED LED DOWNLIGHT 3500K. <br />NEW <br />18 <br />O <br />LITHONIA TYPE: 65BEMW OR EQUAL <br />HANGING LED LIGHT 3500K. <br />NOT IN USE <br />18 <br />TRACK LIGHT <br />NOT IN USE <br />36 <br />SCONCE, DESIGNHOUSE: 573154 OR <br />gD <br />EQUAL <br />NOT IN USE <br />18 <br />EXTERIOR BACK LIGHT W/ BATTERY <br />NOT IN USE <br />60 <br />BACKUP <br />4 <br />DAY— BRITE MCPHILBEN CXXL3RW <br />EXISTING/NEW <br />5 <br />z <br />EMERGENCY EXIT LIGHT <br />7 <br />HUBBELL LIGHTING, CU2SQB EMERGENCY <br />EXISTING/NEW <br />2 <br />BATTERY LIGHT <br />� p w <br />Q� <br />"V <br />Ld <br />W¢UZmO <br />� <br />� v�w� <br />m Ld � w <br />J J O � F J <br />LLJ <br />00 M Q <br />U <br />Z <br />cn w � LLJ <br />= cn�nw <br />zW Q <br />w z U z <br />� o 0 <br />n CD Ld <br />�Q ,— <br />� <br />� <br />N LLJ <br />= zzzoo <br />F— <br />W <br />0 <br />V;'lv rn <br />•� o <br />LL. <br />O J� <br />. Z' J <br />��•.> z <br />cn 4(- <br />CD <br />Q <br />z <br />QI <br />0 <br />�I <br />Q <br />Q <br />I <br />w <br />N <br />� <br />zl <br />Q <br />M <br />U7 <br />z <br />0 <br />U <br />l <br />CL <br />U <br />w <br />LLJ <br />O <br />U cn <br />w <br />N <br />W �' <br />Ln <br />�I <br />1� <br />REVISION <br />1 1 <br />2 <br />33 <br />44 <br />55 <br />66 <br />7 <br />PROJECT TYPE: <br />RENOVATION <br />SCALE <br />AS SHOWN <br />ISSUED DATE: <br />03_08_2024 <br />DRAWN BY: <br />A. FEN G <br />CHECKED BY: <br />A. LI AN G <br />SHEET <br />