_ 1. __ I I ! - 1
<br />D_AOLIT ON PLAN
<br />SC,.I ,E: 3/ 16"=1'-0"
<br />DEI, ;lLITION KEYED NOTES: I )
<br />1. REMOVE EXISTING PARTITION AND COUNTERS. TO REMOVE UNUSED ELECTRICAL WIRING BACK
<br />TO NEAREST JUNCTION BOX.
<br />2. TO REMOVE EXISTING HOOD SYSTEM IN THE KITCHEN AREA
<br />3. TO DEMOLISH EXISTING RESTROOM.
<br />4� POWER PANELS TO BE REMAINED.
<br />5.. NO STRUCTURAL WORK.
<br />6. ACCUMULATION OF AMBULATION OF COMBUSTIBLE WASTE MATERIAL, DUST, AND DEBRIS SHALL
<br />BE REMOVED FROM THE STRUCTURE AND ITS IMMEDIATE VICINITY AT THE END OF EACH WORK
<br />SHIFT OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. NFPA 1:16.2.2.1
<br />7.. DURING DEMOLITION EXITS AND FIRE SAFETY EQUIPMENTS SHALL BE CLEARLY VISIBLE AND
<br />UNOBSTRUCTED.
<br />8. EXISTING CEILING SYSTEM TO BE REMAINED
<br />9, ANY STRUCTURAL WORK AND THE PROPOSED TEMPORARY BRACING TO MAINTAIN THE
<br />STRUCTURAL INTEGRITY DURING CONSTRUCTION.
<br />GENERAL DEMOLITION NOTE:
<br />-- -
<br />- --- --X
<br />1. THE FOLLOWING REQUIREMENTS FOR DEMOLITION, CUTTING AND PATCHING APPLY TO ALL WORK WHICH
<br />IS ALTERED, WHETHER SUCH WORK IS NEW, EXISTING, RENOVATED OR REPLACED:
<br />2. ASBESTOS SURVEY AND ABATEMENT: PRIOR TO DEMOLITION, CUTTING OR PATCHING WORK, ENGAGE A
<br />Ir LICENSED ASBESTOS CONTRACTOR TO PERFORM AN ASBESTOS SURVEY, WHICH IDENTIFIES SPECIFIC
<br />LOCATIONS WHERE ASBESTOS CONTAINING MATERIALS ARE FOUND, AND WHICH PRESCRIBES SPECIFIC Z o 0
<br />ACTIONS REQUIRED FOR ABATEMENT. ENGAGE A LICENSED ASBESTOS ABATEMENT CONTRACTOR TO U ¢ a o � Q
<br />wUS
<br />W REMOVE OR ENCAPSULATE ALL ASBESTOS CONTAINING MATERIALS, ACCORDING TO THE w Z "Z `�' w
<br />AnoN I RECOMMENDATIONS OF THE ASBESTOS CONSULTANT. WHERE ASBESTOS CONTAINING MATERIALS ARE �'< � W w o Q m o
<br />37wmi WALK—IN uFRMUt
<br />ENCAPSULATED IN THE BUILDING, PROVIDE THE OWNER WITH A DETAILED DESCRIPTION OF ALL N w `�'� Z
<br />>-Q-z�
<br />REMAINING MATERIALS, INCLUDING LOCATIONS, APPROXIMATE QUALITIES, AND METHODS OF ECAPSULATEDV p o W °' � �- N W
<br />AND INSTRUCTIONS FOR NOT DISTURBING THE ENCAPSULTED MATERIALS. Ol M M m o �' o o = W
<br />M--i O M �' ¢ WwwQw
<br />"o d' U 000�v>¢
<br />• • • CD
<br />3. PRIOR TO DEMOLITION, CUTTING AND PATCHING, THE CONTRACTOR SHALL LOCATE AND DISCONNECT Z z
<br />CD
<br />UTILITY SERVICES AND ELECTRICAL / MECHANICAL SYSTEMS, OR TEMPORARILY CAP OFF SUCH SERVICES w 00 V, o ,
<br />3 TO THE AFFECTED AREAS. GIVE NOTICE TO, a:Z = Z I.-0
<br />AND COORDINATE WITH UTILITY COMPANIES. OBTAIN w p 00
<br />WRITTEN APPROVAL FROM, AND COOPERATE WITH OTHER PARTIES WHO MAY BE AFFECTED BY A L7 a w 00 LN
<br />INTERRUPTION OF SERVICES.
<br />o
<br />4. CLEARLY MARK THE AREAS AND LIMITS OF DEMOLITION, CUTTING AND PATCHING. IF FEASIBLE, 61*11111810,
<br />PRE—CUT THE LINE OF SEPARATION BETWEEN AREAS OF DEMOLITION AND AREAS TO BE PRESERVED. •. w
<br />x\` EXISTING ,'��� `G ,, .......:CL
<br />�/��/ .,.
<br />WALK—IN DEMOLITION AND CUTTING TECHNIQUES WHICH ARE LEAST LIKELY TO DAMAGE SURROUNDING OR �Q:•''
<br />COMM - ADJOINING WORK. WHERE FEASIBLE, USE HAND TOOLS AND SMALL POWER TOOLS THAT ARE DESIGNED ; �:�, 0, U-
<br />�'•;v>;
<br />FOR SAWING AND GRINDING, NOT HAMMERING OR CHOPPING. DO NOT USE EXPLOSIVES. r2 Lu ��
<br />H 0: z
<br />x
<br />Q • - J
<br />5. STRUCTURAL REQUIREMENTS: DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER WHICH WILL ti:� z° U) �; o
<br />REDUCE LOAD -CARRYING CAPACITY OR LOAD -DEFLECTION RATIO. WHERE STRUCTURAL WORK MUST BE w •j•.,,.. ..,,.•'�`'',•`
<br />2 1 CUT PROVIDE ADEQUATE TEMPORARY SUPPORT BRACING AND/OR SHORING TO RESIST VERTICAL ''•b Rest04
<br />LATERAL AND DYNAMIC LOADS IN THE ENTIRE TRIBUTARY AREA OF THE AFFECTED STRUCTURAL '�
<br />EXISTING I ( / �mNc MEMBERS. WHERE REQUIRED, ENGAGE A LICENSED STRUCTURAL ENGINEER TO DESIGN SHORING /
<br />BUFFET TAB E / I I BRACING SYSTEMS AND JOINT OR CONNECTION DETAILS.
<br />--- - 6. OPERATIONAL AND SAFETY LIMITATIONS: DO NOT CUT AND PATCH OPERATIONAL ELEMENTS OR SAFETY
<br />ol
<br />RELATED COMPONENTS IN A MANNER WHICH WILL REDUCE INTENDED PERFORMANCE OR SAFETY FACTOR,
<br />OR WHICH WILL RESULT IN INCREASED MAINTENANCE OR REDUCED OPERATIONAL LIFE.
<br />-- -' 7. VISUAL REQUIREMENTS: DO NOT CUT AND PATCH WORK IN A MANNER WHICH WILL RESULT IN
<br />lo
<br />LESSENING OF THE AESTHETIC QUALITIES OF THE BUILDING OR SITE, OR THAT WILL RESULT IN VISUAL
<br />' EVIDENCE OF CUT AND PATCH WORK. WHERE REQUIRED, EXTEND FINISH MATERIALS OVER ENTIRE
<br />UNBROKEN SURFACE AREAS AFFECTED BY CUT AND PATCH WORK. REMOVE AND REPLACE CUT AND
<br />1 PATCH WORK WHICH DOES NOT MEET VISUAL REQUIREMENTS.
<br />o
<br />o Ix
<br />1
<br />lo
<br />I
<br />8. PROTECTION: PROTECT OTHER WORK DURING CUTTING AND PATCHING OPERATIONS TO PREVENT
<br />DAMAGE. PROVIDE PROTECTION OF ALL WORK FROM ADVERSE WEATHER CONDITIONS. WHERE
<br />OPENINGS ARE CREATED IN ROOF OR EXTERIOR WALLS, PROVIDE TEMPORARY ENCLOSURE OF SUCH
<br />OPENINGS ON A DAILY BASIS, AND WHENEVER ADVERSE WEATHER THREATENS OR EXISTS.
<br />XII ELECTRICAL DEMOLITION NOTES
<br />1. THE CONTRACTOR SHALL REMOVE ALL UNUSED AND ABANDONED WIRING AND CABLING FROM THE
<br />r CEILING THAT ISN'T LABELED FOR FUTURE USE AS REQUIRED BY THE NEC. THIS SHALL INCLUDE BUT
<br />�I
<br />r IS NOT LIMITED TO FIRE ALARM, POWER, SECURITY, CONTROLS, DATA, TELEPHONE, A/C ETC.
<br />2.CIRCUITS MADE SPARE SHALL BE UPDATED ON PANEL SCHEDULES. DIRECTORY CARDS SHALL BE
<br />REPLACED WITH NEW TYPED DIRECTORIES, INCLUDING ALL NEW LOADS IN ADDITION TO SPARES.Lj
<br />HAND -MARKED NOTES WILL NOT BE ACCEPTED.
<br />3.CARE SHALL BE TAKEN TO RELOCATE ALL EXISTING EQUIPMENT THAT IS BEING MOVED BUT REMAINING
<br />- :I AFTER COMPLETION OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL EXISTING TO
<br />REMAIN OR RELOCATED EQUIPMENT AT THE SAME LEVEL OF FUNCTIONALITY FROM THE ACCEPTANCE OF
<br />THE CONTRACT OF FINAL COMPLETION. ANY DAMAGE OR LOSS OF FUNCTIONALITY SHALL BE REMEDIED
<br />BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER.
<br />4.EQUIPMENT INDICATED TO BE REMOVED AND NOT RE -USED SHALL REMAIN THE PROPERTY OF THE
<br />OWNER AND RETURNED OR STORED AS DIRECTED.
<br />5.CONDUITS AND RACEWAY SYSTEMS MAY BE ABANDONED WHERE CONCEALED HOWEVER SHALL BE ^ M o
<br />REMOVED WHERE EXPOSED. REMOVED OUTLETS SHALL BE PROVIDED WITH BLANK COVERS, COLOR PER A M
<br />THE ARCHITECT'S DIRECTION. a z
<br />1 o
<br />6.EXISTING RACEWAYS AND WIRING ARE ALLOWED TO BE RE -USED PROVIDED THEY MEET THE A
<br />^
<br />SPECIFICATIONS FOR THE NEW SYSTEM(S). Z A ,.un.� z
<br />7.ALL OUTAGES SHALL BE COORDINATED WITH THE OWNER. THE CONTRACTOR SHALL PLAN TO MINIMIZE
<br />ALL OUTAGES. Z
<br />&CIRCUITS SHALL STAY FUNCTIONAL WHERE DEVICES/FIXTURES ARE BEING DEMOLISHED THAT SHARE A 0
<br />COMMON CIRCUIT WITH DEVICES/FIXTURES THAT ARE TO REMAIN. WIRING SHALL BE REMOVED AS FAR
<br />AS POSSIBLE WHILE MAINTAINING EXISTING TO REMAIN OPERATION. o O W W W
<br />9.THE CONTRACTORS SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT NOT REUSED OR NOT cn N N ❑
<br />NECESSARY FOR THE COMPLETION OF THIS PROJECT. REVISION
<br />1 1
<br />2
<br />3
<br />4
<br />5
<br />6
<br />7
<br />PROJECT TYPE: RENOVATION
<br />SCALE AS SHOWN
<br />ISSUED DATE: 03_08_2024
<br />DRAWN BY: A•FENG
<br />CHECKED BY: A. LI AN G
<br />SHEET
<br />
|