AUXILIARY DRAIN VALVE <br />(NOT TO SCALE) <br />GLOBE VALVE OR EQUAL <br />PIPE SUPPORT - TYPE S01 <br />TOP BEAM CLAMP W/ RING HANGER <br />(NOT TO SCALE) <br />FIRE SPRINKLER RISER DETAIL <br />6" DI STUB -UP X 6" STEEL RISER <br />6 9d <br />E <br />.a <br />E <br />coo <br />0 <br />CD <br />0 <br />N <br />O <br />N <br />N <br />N <br />n <br />Q <br />3 <br />N <br />a <br />.c <br />(n <br />I <br />N <br />0 <br />L <br />d <br />3 <br />J <br />END OF BRANCHLINE <br />RUN (OR EQUAL) <br />0'-6" NIPPLE AND <br />TO BE PROVIDED <br />ON `'TRAPPED'nPIPING SECTIONS <br />CONTAINING MORE THAN 5 GALLONS <br />OF WATER. (PER NFPA 13) <br />INSPECTOR'S <br />TEST <br />WET <br />SYSTEM <br />ASSEMBLY <br />(NOT TO SCALE) <br />ROOF DECK <br />DETAIL KEY NOTES <br />1. 1" SCHED. 40 FROM SYSTEM. <br />J <br />J <br />O3 <br />2. 1" SCHED. 40 PIPE NIPPLE. <br />0_ <br />3. 1" COMBINATION INSPECTOR'S TEST AND <br />O2 <br />0 <br />w <br />DRAIN VALVE WITH INTEGRAL PRESSURE <br />RELIEF VALVE. <br />I- <br />x <br />4. PIPE ESCUTCHEONS AND WATERPROOF <br />w <br />PENETRATION. <br />_ <br />\\ <br />5. 1" GALVANIZED SCHED, 40 PIPE NIPPLE. <br />6. 45' ELBOW WITH REDUCING BUSHING AND <br />5.6K STANDARD COVERAGE SPRINKLER HEAD <br />WITH FRAME ARMS BROKEN OFF. <br />7. SPLASH BLOCK. <br />® <br />8. SIGHT GLASS. <br />w <br />(0 <br />D- <br />a. <br />4 <br />I <br />a <br />- <br />O <br />I <br />o° <br />a� <br />I <br />5 <br />O <br />c <br />FINISHED FLOOR <br />PIPE SUPPORT - TYPE S16 <br />'SAMMY SUPER SCREW' W/ RING HANGER <br />(NOT TO SCALE) <br />'Z' PURLIN <br />PRPUPROVIDE HEX NUT FOR <br />LL-OUT RESISTANCE <br />"SAMMY SUPER SCREW" MODEL <br />SDWR - INSTALLED WITH - <br />RECOMMENDED NUT DRIVER - CAD PLATED FERROUS <br />ALL -THREAD ROD <br />SEE MINIMUM SIZE <br />REQUIREMENTS BELOW <br />+ PIPE <br />(4" MAX.) <br />ALL THREAD ROD SIZES <br />PIPE SIZES 1" - 4" -- ROD SIZE = 3/8" <br />NOTE: <br />SAMMY SUPER SCREW MODELS <br />SWDR 1" & SWDR 1%" ARE FM <br />APPROVED FOR PIPE SIZES UP TO 4" <br />TYPICAL GOOSENECK ARMOVER <br />(NOT TO SCALE) <br />SEE PLAN FOR ACTUAL <br />ARMOVER DIMENSIONS <br />I <br />J <br />U <br />q-FL <br />(� SEE PLAN VIEW FOR <br />L RELATIVE BRANCH LINE <br />AND MAIN ELEVATIONS <br />BRANCH LINE <br />TEE OR 90' ELL <br />SEE HEAD SCHEDULE FOR <br />FIRE SPRINKLER FINISH <br />AND HEAD TYPE <br />SCH 40 DROP NIPPLE <br />CUT LONG, FIELD CUT TO <br />FINAL CEILING ELEVATION <br />CEILING ELEVATION <br />STEEL BAR JOIST <br />OR BEAM - CAD PLATED FERROUS <br />_ ALL -THREAD ROD <br />SEE MINIMUM SIZE <br />REQUIREMENTS BELOW <br />PIPE <br />ALL THREAD ROD SIZES <br />PIPE SIZES 1" - 4" -- ROD SIZE = 3/8" <br />PIPE SIZES 5" - 8" -- ROD SIZE = 1/2" <br />PIPE SUPPORT - TYPE T03 <br />TRAPEZE USING TBCs W/ RING HANGERS <br />(NOT TO SCALE) <br />'A' <br />UL LISTED TOP BEAM <br />CLAMP W/ LOCK NUT <br />-TYPICAL- <br />STEEL BAR <br />INVERTED TBC <br />TO PREVENT <br />SLIPPING <br />TRAPEZE MEMBER <br />PIPE <br />SIZE <br />"A' <br />MAX. <br />TRAPEZE <br />MEMBER <br />1 <br />8'-0" <br />2" SCH, 40 PIPE <br />1 1/4 <br />8'-0' <br />2" SCH. 40 PIPE <br />1 1/2 <br />8'-0- <br />2- SCH. 40 PIPE <br />2 <br />8'-0' <br />2" SCH. 40 PIPE <br />2 1/2 <br />7'-0' <br />2" SCH. 40 PIPE <br />2 1/2 <br />8'-0" <br />2 1/2" SCH. 40 PIPE <br />3 <br />6'-O" <br />2' SCH. 40 PIPE <br />3 <br />8'-0" <br />2 1/2" SCH 40 PIPE <br />4 <br />5-O" <br />2" SCH. 40 PIPE <br />4 <br />8'-0' <br />2 1/2" SCH 40 PIPE <br />6 <br />3'-0" <br />2' SCH. 40 PIPE <br />6 <br />W-0' <br />2 1/2' SCH. 40 PIPE <br />6 <br />7'-0" <br />2 1/2" SCH, 40 PIPE <br />6 <br />10'-0" <br />3' SCH. 40 PIPE <br />UL LISTED SWIVEL <br />_ <br />RING HANGER (TWO <br />- <br />CAD PLATED FERROUS <br />TYPICAL). WHEN <br />- <br />ALL -THREAD ROD SEE <br />SUPPORTING PIPE <br />- <br />MINIMUM SIZE <br />SIZES LARGER THAN <br />- <br />REQUIREMENTS BELOW <br />TRAPEZE MEMBER <br />PIPE SIZE, PROVIDE <br />UL LISTED SWIVEL <br />"HEAVY DUTY" <br />RING HANGER <br />HANGER RINGS. <br />+ <br />PIPE <br />ALL THREAD ROD SIZES <br />PIPE SIZES 1" - 4" -- ROD SIZE = 3/8" <br />PIPE SIZES 5" - 8" -- ROD SIZE = 1/2" <br />PIPE SUPPORT <br />TRAPEZE USING TBCs W/ RING HANGERS <br />(NOT TO SCALE) <br />'Z' PURLIN 'A' <br />1/2" BOLT AND <br />WASHER ARRANGEMENT <br />"SAMMY SUPER SCREW" MODEL 1/2" EYE RD� 1/2" CAD -PLATED COUPLING <br />SDWR - INSTALLED WITH <br />RECOMMENDED NUT DRIVER <br />FOR PIPE SIZES 4" AND <br />SMALLER. <br />INVERTED TBC <br />TO PREVENT <br />SLIPPING <br />TRAPEZE MEMBER <br />PIPE <br />SIZE <br />"A' <br />MAX. <br />TRAPEZE <br />MEMBER <br />4 <br />5'-0' <br />2" SCH. 40 PIPE <br />4 <br />8'-0- <br />2 1/2" SCH 40 PIPE <br />6 <br />3'-0" <br />2" SCH. 40 PIPE <br />6 <br />5'-0" <br />2 1/2" SCH. 40 PIPE <br />6 <br />1 7'-0' <br />2 1/2" SCH. 40 PIPE <br />6 <br />10'-0' <br />1 3' SCH. 40 PIPE <br />1/2" CAD PLATED FERROUS <br />ALL -THREAD ROD <br />MOTE: <br />USE EYE ROD <br />ATTACHMENT TO <br />+ PURLJNS FOR PIPES <br />6" AND LARGER IN <br />DIAMETER. <br />CAD PLATED FERROUS <br />ALL -THREAD ROD SEE <br />MINIMUM SIZE <br />REQUIREMENTS BELOW <br />UL LISTED SWIVEL <br />RING HANGER <br />+ PIPE <br />ALL THREAD ROD SIZES <br />PIPE SIZES 1" - 4" -- ROD SIZE = 3/8" <br />PIPE SIZES 5" - 8" -- ROD SIZE = 1/2" <br />AUTOMATIC AIR VENT <br />(NOT TO SCALE) <br />AUTOMATIC AIR VENTING NOTES <br />1). ONLY A SINGLE AIR VENT IS <br />REQUIRED PER NFPA 13. <br />2). THE VENT SHALL BE INSTALLED <br />NEAR A HIGH POINT IN THE <br />SYSTEM. (EX. TOP OF A <br />VERTICAL RISER, ELEVATED <br />BRANCHUNE, AND UNDER ROOF <br />PEAKS.) <br />RECOMMENDED INSTALLATION: <br />1). SHOULD BE INSTALLED OFF THE <br />TOP OF HORIZONTAL PIPING. <br />2). DO NOT INSTALL AIR VENT OFF <br />THE BOTTOM OR SIDE OF <br />HORIZONTAL PIPING. <br />3). SHOULD BE INSTALLED NEAR <br />THE END OF SYSTEM BRANCH <br />LINES, WHENEVER POSSIBLE. <br />4). SHOULD BE INSTALLED OVER <br />AREAS WITHOUT CEILINGS, <br />ABOVE LAY -IN CEILINGS, OR <br />ABOVE AN ACCESS PANEL. <br />3/4" NPT OUTLET. <br />AGF MODEL 7900V <br />IS SHOWN. <br />STANDARD DRAIN <br />LINE MAY BE <br />INSTALLED. <br />1" NPT INLET <br />- - <br />1" SCHED-40 NIPPLE ADJUSTABLE <br />PURGE VALVE WITH <br />HOSE CONNECTION <br />SPRINKLER BRANCHLINE <br />PIPE. SEE PLANS FOR SIZE <br />N <br />3 <br />I <br />MATERIAL DESCRIPTION <br />ITEM <br />DESCRIPTION <br />1 <br />6" 120 VAC ELECTRIC BELL W/ WEATHI <br />2 <br />6' VANE -TYPE WATER FLOW SWITCH <br />3 <br />6' RISER CHECK VALVE <br />4 <br />6" GROOVED BUTTERFLY VALVE <br />I <br />RISER GENERAL NOTES: <br />1). ALL OUTSIDE STEEL PIPING EXTENDING THROUGH THE <br />EXTERIOR WALL SHALL BE GALVANIZED WITH GALVANIZED <br />FITTINGS. <br />2). ALL GROOVED COUPLINGS SHALL BE OF THE "RIGID- TYPE. <br />3). ALL DIMENSIONS SHOWN ARE CENTER -TO -CENTER <br />DIMENSIONS AND SHALL BE FIELD VERIFIED BEFORE <br />FABRICATION AND INSTALLATION. <br />4). ALL ELECTRICAL WIRING SHALL BE PERFORMED BY OTHERS. <br />5). INSTALL ELECTRIC BELL ON OUTSIDE WALL. <br />6). PIPE DIMENSIONS SHOWN ARE FOR THE VALVES AND <br />DEVICES SPECIFIED USING STANDARD GROOVED FITTINGS. <br />O = HYDRAULIC NODE POINT <br />2" MAIN DRAIN SHALL BE <br />PIPED TO OUTSIDE BUILDING <br />WALL SUPPLY GALVANIZED <br />PIPING THROUGH WALL WITH <br />1 2" PIPE ESCUTCHEONS BOTH <br />M SIDES OF WALL. <br />g <br />tZ <br />M <br />�— RBASE <br />NPE� BE <br />ESTRAINEDPER A 24 <br />SCALE: 1/2" = 1'-0 <br />BUILDING EAVE HEIGHT <br />21'4" �] @ REAR OF BUILDING <br />0' 0" BUILDING FINISH FLOOR <br />K-11.2, STANDARD <br />RESPONSE, HIGH <br />TEMPERATURE UPRIGHT, - <br />INSTALLED WITH <br />DEFLECTOR LOCATED 1" <br />TO 12" BELOW ROOF <br />INSULATION. TYPICAL. <br />12 <br />2" GRIDLINE. <br />"'�4" SECONDARY <br />MAIN <br />_ _ _ MAX STORAGE HEIGHT OF UP TO CLASS IV COMMODITIES ON RACKS. <br />0 <br />0 <br />I <br />fV <br />6" F <br />MAIN <br />A FIRE SPRINKLER SIMPLE SECTION <br />FP-3 SCALE: 1 /8" = 1'-0" 2 1 0 4 <br />BUILDING EAVE HEIGHT <br />@ FRONT OF BUILDING n P8' 0" <br />BUILDING FINISH FLOOR 0' 0" <br />DRAWINGS PREPARED BY: <br />ENGINEER OF RECORD: <br />NOTE: <br />{HATCHER. ENGINEERING INC. <br />WHEN SIGNED AND SEALED <br />BY THE <br />FIRE PROTECTION ENGINEERING - LIFE SAFETY <br />ENGINEER -OF -RECORD <br />(USING EITHER A DIGITAL <br />Florida Cert. of Authorization #: 28929 <br />SIGNATURE OR INK <br />PLANT CITY OLDSMAR. <br />SEAL\SIGNATURE), PRINTED <br />COPIES OF THIS DOCUMENT <br />2108 W. Risk Street 720 Brooker Creek Blvd. <br />ARE NOT CONSIDERED <br />Plont City, FL 33563 Suite 205 <br />SIGNED AND SEALED AND <br />Tel.• (813) 752-6900 Oldsmor, FL 34677 <br />DIGITAL SIGNATURES MUST <br />Fox: (813) 752-6911 <br />BE VERIFIED ON ANY <br />www.hotcherengin&ering.com <br />ELECTRONIC COPIES. <br />e-mail.- NJH@hotcherengineering.com <br />JAMES P. MORIZZO, #93056 PLOT DATE: <br />z <br />w <br />U <br />V <br />z <br />Q <br />LL <br />O � � <br />L.L_ U op <br />LL Q M <br />00�M <br />zLL`� <br />0Uj_� <br />Q J_ M <br />V LA 00 <br />ce- <br />_ LU <br />N M N <br />0 <br />V <br />Z <br />0Y <br />a <br />LL_O QUl <br />O <br />�- <br />J Q Z 0In <br />LLJ <br />u=Q_j <br />Z <br />a- <br />LL_ Q v N <br />W <br />,,�zg� <br />N <br />_on- <br />::E <br />Z <br />LWL W <br />W U_ tJ <br />O <br />Ln <br />w <br />Q W <br />of <br />LL_ <br />Z <br />Of <br />O <br />U <br />v <br />w <br />w <br />a o <br />DESIGNED BY <br />JPM <br />DRAWN BY <br />JPM <br />CHECKED BY <br />HEI <br />PROJECT NO./CAD CODE <br />2023-2653 <br />DATE <br />10/12/23 <br />DRAWING NO. <br />FP-3 <br />