My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38156 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38156 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 6:26:04 PM
Creation date
2/18/2025 3:24:46 PM
Metadata
Fields
Template:
Building Plans
Street #
38156
Location
Fallstone Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
4877
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PqF <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j WALL SWITCH <br />$3 THREE-WAY SWITCH <br />24 FOUR-WAY SWITCH <br />jR RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />F-0 WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e TRACK LIGHT <br />�-� FLUORESCENT LIGHT FIXTURE <br />Q EXHAUST FAN <br />Awl EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />�B PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />WWI ELECTRIC PANEL <br />DISCONNECT SWITCH <br />�67 <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />GD (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />LAV i\ <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />I OPT <br />I <br />LAV LAV <br />L W/C <br />SHOWER <br />`3 <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -A- (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31768 <br />LOAD WATTS — 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />1 <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />NEMA 1 <br />RMAN <br />200 AMP <br />3R <br />Cable <br />#4 Solid COPPER Ground <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />typical 150-200 Amp Electrical Riser Diagram <br />OTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />HE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />O <br />OUTDOOR LIVING <br />IN <br />INSTALL LIGHT �`�.01� <br />ROUGH -IN '0- <br />FOR OPT. < / <br />FAN/LIGHT! GFI <br />AT, <br />I <br />I <br />DINING \� <br />I <br />I <br />KITCHEN <br />JF <br />�O <br />--- <br />- -- --- GFI � --- <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />194 <br />GREAT ROOM <br />/,>ROUGH -IN\ <br />FOR OPT. <br />FAN/LIGHT <br />y� � <br />I I <br />I <br />FOYER <br />I <br />I <br />I DB <br />ENtRY I WP0 - <br />LIGHT As �O GFI® <br />PER SPECS <br />DB & GFI TO <br />BE ALIGNED <br />----------- <br />VERTICALLY <br />I <br />I <br />I <br />I <br />I <br />r-GF-L _ .j <br />C.M <br />1 UPSTAIRS t <br />!-: f�(R <br />a I <br />DISCONNECT <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />— — — — — —� <br />I <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE OWNER'S <br />RANGE HOOD PER <br />SPECS BEDROOM <br />^� /,,^TROUGH -IN <br />FOR OPT. <br />FAN/LIGHT <br />� I � <br />S.D. <br />GFI ------ <br />---------- <br />0. BATH I <br />W <br />I <br />\ /P I <br />I WIC I <br />\ J_— JVV — <br />GFI I <br />r \ <br />OWNSTAI <br />- -- -1NI P. -_ d <br />GFI <br />Lt—' `� BATH 2 <br />@ 44" W.H. <br />\ <br />A.F.F. ' \ O <br />I \ <br />1 <br />GFI <br />WIC -- <br />IGARAGE <br />I I <br />I <br />GARAGE <br />LIGHT AS <br />\PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />r- — — — — — — — — — — — — — — — -- <br />I I <br />I I <br />Ip z I <br />IQ d I <br />I0 Q I <br />ILL <br />— U <br />U.1 J II <br />nl I <br />i <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE: ),4'=1'-0" <br />L <br />\ HLJ' <br />\� LOFT <br />C.M \ <br />i� (U)S.D / � <br />I <br />/�>ROUGH-IN <br />FOR OPT. <br />FAN/LIGHT <br />\BEDROOM 2 <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: Ya"=1'-0" <br />c.a <br />O <br />M <br />N <br />v <br />�cr <br />c7 • Q <br />Q <br />i, <br />LU <br />N <br />0 <br />N <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential <br />7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N <br />HQ <br />� <br />0 V <br />N rn <br />oo �_ C <br />r <br />N <br />N a <br />M <br />Q <br />M oa � LL <br />t y LL W <br />Z <br />J U_ o <br />— o� a Y <br />2 <br />�0c <br />0�CP Cr W <br />Z <br />ILW <br />M Z Q ..a <br />N O U �d co <br />Z <br />W <br />U <br />❑ ❑ <br />z <br />z o 3 <br />Q� <br />J <br />a_ Y) <br />n <br />In4-1 <br />Z <br />U <br />Q) <br />s <br />LL <br />W <br />U <br />0 <br />w $ <br />IIA <br />c Y <br />N <br />= U) <br />U <br />w <br />f- J E <br />t 8 <br />�n.. <br />,I <br />U ) <br />• <br />C N <br />N 0CD <br />S III1 <br />o <br />w <br />My <br />Z <br />Ce E <br />�o <br />�' <br />> <br />MN <br />Q <br />a o <br />�� <br />�"i <br />Z® <br />oa <br />F- <br />z0 <br />1M <br />a` <br />0 <br />Z <br />O E <br />N � <br />i <br />z <br />woo <br />< <br />a-Z <br />M <br />w <br />d <br />CY <br />^ � <br />z <br />U <br />m O <br />m� <br />o <br />Ott <br />Z <br />Z. <br />Z <br />Q <br />2. <br />a <br />o� <br />LL0 <br />ZZ <br />ag <br />W <br />U � <br />ire <br />�� <br />aLL <br />N1 <br />zr <br />J <br />� <br />w <br />=0 <br />'O <br />o <br />�p <br />V <br />w� <br />z. <br />¢ <br />a = <br />O� <br />3 <br />0 <br />•� T <br />CD <br />T <br />N <br />f <br />C7 <br />c� <br />V! <br />T <br />� <br />c.6 <br />M <br />,-- <br />_ <br />i0 <br />O <br />CV <br />M <br />n <br />�+ Y <br />s <br />C mO <br />0o <br />E <br />O <br />Q <br />co <br />LO <br />00 <br />r <br />.L <br />O <br />o <br />Z <br />@ <br />Z <br />7 <br />E O <br />V) <br />tl <br />U � <br />Q 0 <br />� <br />JOB <br />NO: 22-06595-06588 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.