Laserfiche WebLink
L <br />MIRROR <br />oIrkI011M10 1M <br />F 0�_- 111 I-q 71111 F 0�_- 11 <br />I MM 10 AM <br />OWNER'S BATHROOM <br />SCALE: 3/8" =V-0" <br />0 <br />BATHROOM 2 <br />SCALE: 3/8" = 1'-0" <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 X 25 <br />S.H. <br />13 <br />20X38J <br />18 X37 <br />S.H. <br />14 <br />20X501 <br />184X50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 4 <br />S.H. <br />16 <br />20X72 <br />18JX71J <br />S.H. <br />11-12 <br />271/4X26 <br />26X25J <br />S.H. <br />11­13 <br />271/4X38J <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 J <br />26 x 50 <br />S.H. <br />11-15 <br />271X63 <br />26X621/2 <br />S.H. <br />11-16 <br />274X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 1 X 38 J <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 } X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />734 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 J <br />S.H. <br />33 <br />54X381 <br />521X37J <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 } X 62 J <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 } <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN = 14'-2" 42" KNEE WALL <br />WITH 1x8 CAP & <br />3/4" PLYWOOD CASING (AT 2nd <br />DECKING �� FLOOR ONLY) <br />(2) 2X8 w/ 1/2" <br />N FLITCH HEADER \ <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. F. FL. <br />- - - - - - - - - - - - - - - - - - - <br />cv <br />DRYWALL <br />17 <br />1/4" TO 2" DIA <br />16 <br />ANDRAIL NO <br />15 <br />ESS THAN 34" <br />14 <br />�� <br />OR MORE <br />13 <br />U <br />VH <br />HAN 38" ABV. <br />12 <br />z <br />READ NOSING <br />11 <br />CONT. <br />\10 HAND RAIL <br />�9 <br />U <br />METAL <br />HANDRAIL <br />rn <br />8 <br />w <br />o) <br />BRACKET <br />7 <br />00 <br />= <br />L11 <br />BLOCKING AS <br />Zo <br />6 <br />REQUIRED <br />5 <br />2x STRINGERS 1, 4 <br />00 <br />3 <br />F.FL. \ 2 1 F.FL. HANDRAIL DETAIL <br />14 2" 2x4 #2 SYP. P.T. THRUST SCALE: 3" =1'-0" <br />BLOCK W/(2)-1/4"x 31/2" <br />TAPCONS @ 16"o.c. AND <br />TYP. STAIR SECTION 3" FROM EA. END. <br />SCALE: 1/4" = V-0" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X8 #2 SYP W/ 1/2" <br />H2 <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 114 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2 <br />"Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding % inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />18'-4" <br />VERIFY <br />AC PAD LOCATION OF <br />A/C PAD <br />HB <br />A <br />------------------------- <br />OUTDOOR LIVING <br />S3 <br />9'-4" CLG. A.F.F. <br />CONCRETE <br />8" 6'-0" 10'-8" <br />= <br />6'-8" 3'-10" 3'-10" <br />2'-8" <br />o� <br />f- a) <br />6068 SGD C <br />50 <br />= <br />�o r <br />O <br />T2468REF <br />® 7'-11" 3'-2" <br />I <br />U-7" <br />o I <br />O <br />O <br />N <br />© U)3 <br />I <br />M <br />DINING N KITCHEN <br />Lu <br />Z I'0 <br />9'-4" FLAT CLG. 9'-4" FLAT CLG. <br />00 <br />TILE TILE <br />® <br />I <br />SINK w/ <br />I <br />D/W DISPOSAL <br />F---� <br />io <br />I I <br />FLRG. LINE - - - - - - - <br />16" CNTR. AT 42"--J ;n <br />o <br />�r <br />A.F.F. <br />1/2 WALL <br />C,.) <br />OA N <br />r <br />CAPPED <br />1 <br />r <br />® <br />II UP 2 <br /><V <br />I 3 <br />M <br />GREAT ROOM <br />5 <br />D1 <br />TYP. U.N.O <br />® <br />9'4" FLAT CLG. <br />CARPET <br />7 <br />13'4' <br />oIL <br />M <br />GG ^ <br />9 <br />S3 <br />10 <br />UD <br />'- <br />11 <br />b <br />A <br />12 <br />'n <br />N <br />2x6 WALL <br />M <br />6'-8" <br />to 2'-8" 4'-4" <br />*NO UPLIFT* <br />® <br />Q <br />- <br />S4 <br />-- - -- <br />LINE <br />00 _ <br />N �{�{��p <br />N <br />_FLRG. _ <br />H1 <br />J <br />10 <br />s <br />)71 <br />TILE <br />v <br />N <br />Cco CnV <br />r <br />u <br />v I� <br />■ <br />FOYER <br />' <br />_I I 16" SQUARE- <br />CMU COLUMN <br />1ST FL <br />SCALE: Y4"=1'-0" <br />9'-4" FLAT CLG. 2868 <br />TILE <br />oo -�_EDGEOFSLABZ' <br />TT.O.M_ _`r BEYOND WALL `� W.H. <br />R.f• <br />.■■■■.- ■,,,r 1 <br />I E4 us OF] Flat] <br />M�� : 1 <br />9'-4" IPLG. A.F.F. <br />CONCRETE <br />Im Emit <br />----o <br />�_O <br />2'-6" <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />PROTECTION <br />WHEN <br />REQUIRED PER <br />FBC <br />1-CAR QARAG E <br />9'-4" FLAT CLG. <br />0" <br />r- - - - - - - - - - <br />------ <br />00 :� <br />I <br />I <br />I <br />I <br />co <br />I <br />I <br />■ I LINE OF 2nd STRY. <br />ABV. <br />I- - <br />- t <br />00 <br />I **NOTE <br />* I <br />8o p <br />I BLK. WALLS <br />RE 8'-8" <br />TALL FOR "A" <br />NIT 5'-8" <br />o <br />FROM FRONT <br />OF <br />00 <br />K GARAGE <br />TYP. @ <br />I <br />I S4 GARAG <br />OOR <br />8'x7' GARAGE <br />1'-8" 8'-0" <br />5'-8" <br />V-8" <br />7' <br />8'-8" 1 <br />18'-4" <br />OOR PLAN - UNIT -A 1532 <br />D1 <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'4" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOU S <br />@ 12" O.C.* <br />THIS IS ONLY USED <br />FINISH <br />** WALL SHEATHING 1 <br />REFER TO SHEATHIN <br />lr) <br />to <br />O <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />BLE STUDS @ 16 O.C. OR SINGLE STUD r o + <br />WIop <br />TH PLASTER OR STUCCO EXTERIOR <br />34" 12'-0" S-0" 01 <br />10 <br />5132" EXPOSURE 1 OR EQUIVALENT. <br />G SCHEDULE FOR ATTACHMENTS** V-4" & V-8" 3'-10" J 5'-0" & 3'-10" J 2-8" <br />10 0 <br />© O <br />MOD 25 SH MOD 25 SH <br />(39"x59") (39"x59") <br />EGRESS( EGRESS <br />o CO <br />OWNER'S <br />55 BEDROOM <br />D1 <br />8'_0" FLAT LG. <br />CARPET <br />I <br />i'V <br />o <br />N17'-8" <br />ioUV <br />6'-4" 4'-4" 7'-0" <br />I <br />® M.C. ----- R&S <br />D O. B TH I 22"x36° <br />' <br />8'-0" FLA CLG. ATTIC I N <br />CARP T ACCESS1W I C I _ <br />� (V <br />io h CD 1 \\ 8, (�" FLAT CLG I io Cl) <br />V N1 N 1 (CARPET I� <br />PW01 <br />LIDI <br />0) I I J I D1 <br />J _V- <br />>04 <br />N Om I <br />FO 2868 5 <br />00 <br />6 <br />oo - 7 00 <br />E TO oo in <br />7' A. _ 8 <br />PRON <br />AHU 9 <br />60"x <br />00 OWER P I ~ 10 <br />i0 <br />R/A I I 11 in <br />5' 114' 4'-4" 3,-4„ I 1 S-8, 19 <br />LOFT I' 13 0 <br />I <br />® �O 8'-0" FLAT CLG. I 14 <br />00 CARPET 15 eo <br />00 I 16 <br />17 <br />�) UP 18 <br />0 1/2 WALL <br />b� CAPPED <br />>04 <br />O = 5'-4 1'-10" 9'-6" )04 <br />v <br />® r^ EO <br />1 0 in 2668 <br />N BATH� <br />8'-0" FLAT CLG j <br />■ M.C. <br />CARPET <br />I WIC <br />F-0" FLAT CLG. CV <br />( CARPET - 2668 <br />IY in <br />----- ---- BEDROOM 2 <br />R&S <br />8'-0" FLAT CLG. <br />■ _ CARPET <br />r� a G.T. <br />F, G.T. - - <br />00 0 <br />MOD 25 SH <br />(39"x59") <br />■ <br />EGRESS <br />40 3'-8" S-10" S-10" <br />4'-0" 7'-4" <br />o 0? <br />7'-0" 11'4" 1 &D ") 18'-4" <br />- - �J <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />OA +29.7 / -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 OD +28.3 / -37.0 <br />OE +26.6 / -29.1 OF +26.6 / -33.5 <br />OSEESN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE 1 +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence, & Attics - Not Less than 1/2" Gyp. Ed. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Ed. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />e� r <br />s CV <br />N A- <br />ao ( , <br />c.D <br />Q <br />tf, _ <br />(J . r. <br />;-1 <br />ff` 7 7� '3 <br />UJ <br />i "�,J •• <br />C <br />F. f.rlf ... '.tt,'• .it'. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />a s <br />C 00 0m <br />U) <br />M M K ik LL <br />a = � S22 + w <br />M LL 5 6 <br />Z L N Lu <br />o <br />3.X, <br />W 7 N N S <br />IL0 <br />W °)0 m w <br />z � NZ a <br />Z N O U U <br />W ❑❑ <br />0 V M � <br />Z N QQQh <br />z n <br />Q <br />J <br />N <br />0 <br />Ln z <br />o <br />Co <br />A-1 <br />ti1 C- <br />� _ 8 <br />�~ <br />(� r- in <br />U <br />r- J E <br />c -IO <br />Q N 0 see <br />o w <br />M o � <br />U_ Q o <br />E ❑ 0 Z <br />cc < _ W � <br />F ?o U0 <br />Z V❑ <br />a ❑ < <br />�O `O ¢ 8 z w1 <br />N <br />Z '0 <br />in ` z� <br />Z J U <br />"m <<w <br />C/) J ¢ 2. <br />IDoa do <br />T <br />W � �w <br />v a� <br />� z �0 <br />o w >° <br />a <br />co <br />�' a �d 00 $ <br />c <br />o T <br />ai <br />m <br />I- (9 <br />_E <br />CD <br />_ M <br />T <br />T co O <br />r <br />C� <br />0 CDT C m O <br />00 E <br />F-- O <br />CD <br />rn <br />N M <br />U-) <br />00 r <br />d) O <br />E '= z <br />l0 � O N <br />z E O <br />E <br />a ci _J a o <br />JOB NO: 22-06595-06588 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />2ND FLOOR PLAN - UNIT -A 1532 <br />SCALE: Y"=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />OA +29.7 / -32.2 © +29.7 / -39.7 <br />© +28.3 / -30.8 OD +28.3 / -37.0 <br />OE +26.6 / -29.1 OF +26.6 / -33.5 <br />OSEESN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE 1 +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence, & Attics - Not Less than 1/2" Gyp. Ed. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Ed. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />e� r <br />s CV <br />N A- <br />ao ( , <br />c.D <br />Q <br />tf, _ <br />(J . r. <br />;-1 <br />ff` 7 7� '3 <br />UJ <br />i "�,J •• <br />C <br />F. f.rlf ... '.tt,'• .it'. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />a s <br />C 00 0m <br />U) <br />M M K ik LL <br />a = � S22 + w <br />M LL 5 6 <br />Z L N Lu <br />o <br />3.X, <br />W 7 N N S <br />IL0 <br />W °)0 m w <br />z � NZ a <br />Z N O U U <br />W ❑❑ <br />0 V M � <br />Z N QQQh <br />z n <br />Q <br />J <br />N <br />0 <br />Ln z <br />o <br />Co <br />A-1 <br />ti1 C- <br />� _ 8 <br />�~ <br />(� r- in <br />U <br />r- J E <br />c -IO <br />Q N 0 see <br />o w <br />M o � <br />U_ Q o <br />E ❑ 0 Z <br />cc < _ W � <br />F ?o U0 <br />Z V❑ <br />a ❑ < <br />�O `O ¢ 8 z w1 <br />N <br />Z '0 <br />in ` z� <br />Z J U <br />"m <<w <br />C/) J ¢ 2. <br />IDoa do <br />T <br />W � �w <br />v a� <br />� z �0 <br />o w >° <br />a <br />co <br />�' a �d 00 $ <br />c <br />o T <br />ai <br />m <br />I- (9 <br />_E <br />CD <br />_ M <br />T <br />T co O <br />r <br />C� <br />0 CDT C m O <br />00 E <br />F-- O <br />CD <br />rn <br />N M <br />U-) <br />00 r <br />d) O <br />E '= z <br />l0 � O N <br />z E O <br />E <br />a ci _J a o <br />JOB NO: 22-06595-06588 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence, & Attics - Not Less than 1/2" Gyp. Ed. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Ed. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Ed. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Ed. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />e� r <br />s CV <br />N A- <br />ao ( , <br />c.D <br />Q <br />tf, _ <br />(J . r. <br />;-1 <br />ff` 7 7� '3 <br />UJ <br />i "�,J •• <br />C <br />F. f.rlf ... '.tt,'• .it'. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />a s <br />C 00 0m <br />U) <br />M M K ik LL <br />a = � S22 + w <br />M LL 5 6 <br />Z L N Lu <br />o <br />3.X, <br />W 7 N N S <br />IL0 <br />W °)0 m w <br />z � NZ a <br />Z N O U U <br />W ❑❑ <br />0 V M � <br />Z N QQQh <br />z n <br />Q <br />J <br />N <br />0 <br />Ln z <br />o <br />Co <br />A-1 <br />ti1 C- <br />� _ 8 <br />�~ <br />(� r- in <br />U <br />r- J E <br />c -IO <br />Q N 0 see <br />o w <br />M o � <br />U_ Q o <br />E ❑ 0 Z <br />cc < _ W � <br />F ?o U0 <br />Z V❑ <br />a ❑ < <br />�O `O ¢ 8 z w1 <br />N <br />Z '0 <br />in ` z� <br />Z J U <br />"m <<w <br />C/) J ¢ 2. <br />IDoa do <br />T <br />W � �w <br />v a� <br />� z �0 <br />o w >° <br />a <br />co <br />�' a �d 00 $ <br />c <br />o T <br />ai <br />m <br />I- (9 <br />_E <br />CD <br />_ M <br />T <br />T co O <br />r <br />C� <br />0 CDT C m O <br />00 E <br />F-- O <br />CD <br />rn <br />N M <br />U-) <br />00 r <br />d) O <br />E '= z <br />l0 � O N <br />z E O <br />E <br />a ci _J a o <br />JOB NO: 22-06595-06588 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />