Laserfiche WebLink
A■ ��Illl��lVl�■■ILIII1uuII,11�ILi11Y1�lY�IItlYIN1s��I�■� ���■�■IY��IWYICII�.11■W JYilll■ �� �■ ■ Y�._YL <br />LEFT ELEVATION <br />SCALE: 3/16" = V-0" <br />RIGHT ELEVATION <br />SCALE: 3/16" = 1'-0" <br />General Notes <br />ROOF CRITERIA: <br />12" OVERHANG U.N.O. <br />PLUMB CUT FASCIA ROOF <br />PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />txterlor uovering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved. (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4%1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />-c o <br />N ; <br />c �` <br />N } X <br />00 <br />o <br />CD 6 <br />y' <br />cc u <br />7 <br />:u V, > . 3 <br />— <br />s >; <br />-3 _ W <br />l i I I I flf it/���rr <br />\�,�\U�tl <br />,\\ �� O W N <br />� <br />'' C� � <br />ate, <br />:• <br />F�-O •'�� <br />r, R0FESS\0a`,`� <br />To the best of the Engineers knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />el <br />W <br />p <br />V C. OC1 N m <br />aj M V 25 LL <br />a C J z U.w <br />t' JLL LL S a <br />13 <br />Z 0 C: a <br />=;_°o <br />i�N� 0 <br />W ��Q' m pjw <br />J <br />z <br />IL Z <br />�, M <br />Z N O 0 °d o <br />2 <br />U !� <br />W ❑❑ <br />V M � <br />Z N M <br />SO S <br />z m <br />Z n <br />Q <br />N <br />M <br />` z a <br />lV^)CD r8 <br />� - <br />cry <br />0 w g <br />C N <br />,N <br />v + � <br />in <br />U <br />= y <br />U 'o <br />° <br />c 2. <br />Y <br />8, <br />o <br />m <br />CD <br />cfl <br />M <br />z� <br />o <br />Z <br />z <br />� <br />Q a <br />E U <br />zo <br />>p <br />Z® <br />oa <br />Z <br />tC <br />o <br />20 <br />U <br />a< <br />W <br />0° <br />oQ <br />�Z <br />N It <br />..�-. LL <br />o <br />¢z <br />m0 <br />Z <br />Cx <br />J <br />U <br />'m <br />; <br />O ¢ <br />Z <br />" w <br />Ew <br />a� <br />of <br />Z <br />�O <br />W <br />29 <br />w <br />a <br />N W <br />J <br />o <br />N� <br />z <br />wa <br />3 <br />�° <br />CD <br />za <br />a� <br />o� <br />c <br />T' <br />ui <br />rn <br />c9 <br />T <br />c6 <br />� <br />V! <br />_ <br />T <br />co <br />CD <br />O <br />M <br />n <br />'°'� Y <br />o <br />c6 <br />�. <br />m <br />O <br />CDCN <br />00 <br />mLO <br />CDCV <br />O <br />>` <br />0 N <br />Co <br />E <br />Q <br />Z <br />Z <br />E iri <br />E 0 rA <br />E <br />fC <br />C <br />a <br />io <br />U J Q <br />J <br />JOB <br />NO: 22-06595-06588 <br />SCALE : AS NOTED <br />SHEET NO. <br />9 <br />