r <br />GENERAL NOTES: <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2017 FLORIDA BUILDING CODE TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />6TH EDITION DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />T.L. HANSON A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />THE BUILDING ( INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />FOLLOWING SUPERIMPOSED LOADS: MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />SLAB: INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />LIVE LOAD - 50 P.S.F. BACKFILLING & COMPACTION ARE COMPLETE <br />DEAD LOAD - 10 P.S.F. <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />WIND: ( INCLUDING ANY BOXED OR FORMED AREAS) - <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 7-10, CHAPTERS 26 THRU 31; PER 2014 FLORIDA BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />BUILDING CODE, RESIDENTIAL - SECTION R301.2.1.1. AND 2014 FLORIDA BUILDING CODE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />SECTION 1609.1.1. ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />COMPONENT & CLADDING WIND LOADS INITIAL TREATMENT. <br />WIND DESIGN ASSUMPTIONS <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT & EXPOSURE ADJUSTMENT <br />COEFFICIENT = 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT = +J- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />ALL OTHER <br />BUILDING <br />ROOF OVERHANG <br />COMPONENT <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32.3/-35.3 <br />2 <br />-65.7 <br />+32.3/-56.2 <br />3 <br />-110.6 <br />+32.3/-89.0 <br />4 <br />N/A <br />+35.3/-38.2 <br />5 <br />N/A <br />+35.3/-47.2 <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE ( INCLUDING LANDSCAPING AND IRRIGATION) . ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />TYPE VB CONSTRUCTION PER FBC 602.5 <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS ( PER FBC R318) . <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />SOIL BEARING & COMPACTION: <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />(MINIMUM . THE CONTRACTORIPROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING ( EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />FOUNDATION LOADING. <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />T.L. HANSON; A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />EXTERIOR WINDOWS &DOOR ASSEMBLIES: <br />NOR PERFORMING ANY SOIL TESTING. <br />ALL EXTERIOR WINDOW & GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/IS2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />T.L. HANSON SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />THE BUILDING LOADS. <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW & DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED. <br />FOUNDATIONS & SLAB -ON -GRADE: <br />SAFETY GLAZING: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA, <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS of SLIDING DOOR <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />ASSEMBLIES. <br />COMPACTED AND TERMITE POISONED SOIL. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />THE NEAREST VERTICAL EDGE 15 WITNIN A 24 INCH RADIUS OF THE DOOR IN A <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR. <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES ( AFTER <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />FINAL SITE GRADING) . THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />CONDITIONS: <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN S 80, FT, <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR, <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />PLANE OF THE GLAZING. <br />SOIL TERMITE TREATMENT: <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING, <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />DRAFTSTOPPING: <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION, <br />IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY IS BROKEN UP INTO TWO OR <br />SHALL STATE <br />MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SQ. FT, <br />BUILDING DATA: <br />OCCUPANCY CLASSIFICATION: ASSEMBLEY A 2 <br />CONSTRUCTION TYPE: V B <br />FIRE PROTECTION: SPRINKLER SYSTEM <br />EGRESS: COMPILES WITH CHAPTER 10 FLORIDA BUILDING CODE <br />2017 6TH EDITION <br />PLUMBING: FIXTURES SHOWN COMPILES WITH CHAPTER <br />4 TABLE 403.1 FLORIDA BUILDING CODE 1017 <br />6TH EDITION PLUMBING <br />RANDY <br />WATSON <br />D E S I G N S I N C <br />DRAFTING DESIGNS <br />13821 U.S. HWY 98 BY PASS DADE CITY, FLORIDA 33523 <br />OFFICE 352-523-2077 FAX 352-567-2070 <br />FRATERNAL ORDER OF EAGLES AERIE 3752 <br />CITY OF ZEPHYRHILLS / PASCO COUNTY, FLORIDA <br />LEVEL ONE BAR <br />AREA INTERIOR <br />BAR <br />LEVEL ONE BAR <br />AREA EXTERIOR <br />STAIR WELL #1 <br />STAIR WELL #2 <br />COOLER & STORAGE <br />ELECTRICAL & <br />MECHANICAL ROOM <br />ELEVATOR <br />TOTAL <br />JOB LOCATION MAP <br />PLANS COMPLY TO FLORIDA FIRE PREVENTION CODE FIFTH EDITION <br />PROVIDE ALL TACTILE SIGNAGE AS REQUIRED <br />STEEL ROOF SYSTEM <br />LIGHT FRAME CONSTRUCTION SIGN NOT REQUIRED <br />3229 / 15 = 215 PEOPLE <br />815/ 200 = 4 PEOPLE <br />459 / 15 = <br />155 <br />165 <br />482 / 300 = <br />125 <br />64 <br />5494 <br />30 PEOPLE <br />N/A <br />N/A <br />2 PEOPLE <br />N/A <br />N/A <br />LEVEL TWO <br />SITE <br />LLS / <br />CITY OF ZE <br />FIRE AND LIFE SAFETY EXAMIN <br />p� COMPLY Wll*H <br />WORK SS RDS <br />NFFA CODES AND AND <br />BAR INTERIOR <br />3260 / 15 <br />= 217 PEOPLE <br />BAR <br />735 / 200 <br />= 4 PEOPLE <br />LEVEL TWO <br />BAR EXTERIOR <br />459 / 15 <br />= 31 PEOPLE <br />STAIR WELL #1 <br />155 <br />N/A <br />STAIR WELL #2 <br />165 <br />N/A <br />ELEVATOR <br />64 <br />N/A <br />TOTAL <br />4838 <br />TOTAL AREA 10332 <br />TOTAL OCCUPANCY 503 PEOPLE <br />PLAN INDEX <br />SHEET B 1: EXISTING LEVEL ONE FLOOR PLAN <br />SHEET B 2: EXISTING LEVEL TWO FLOOR PLAN <br />SHEET B 3: PROPOSED LEVEL ONE FLOOR PLAN <br />SHEET B 4: PROPOSED LEVEL TWO FLOOR PLAN <br />SHEET B 5: PROPOSED SOUTH AND EAST ELEVATIONS <br />SHEET B 6: PROPOSED NORTH AND WEST ELEVATIONS <br />SHEET B 7: FOUNDATION PLAN <br />ROOF PLAN <br />FLOOR JOIST AND BEAM PLAN <br />EXTERIOR DOOR SCHEDULE <br />INTERIOR DOOR SCHEDULE <br />SHEET B 8: DETAILS S-1, S-2, S-3, S-4 <br />SHEET E 1: LEVEL ONE POWER PLAN <br />SHEET E 2: LEVEL ONE LIGHTING PLAN <br />LEVEL ONE ELECTRIC PANEL SCHEDULE <br />LEVEL ONE LOAD CALCULATIONS <br />SHEET E 3: LEVEL TWO POWER PLAN <br />SHEET E 4: LEVEL TWO LIGHTING PLAN <br />LEVEL TWO ELECTRIC PANEL SCHEDULE <br />LEVEL TWO LOAD CALCULATIONS <br />SHEET LS1: LEVEL ONE LIFE SAFETY PLAN <br />SHEET LS2: LEVEL TWO LIFE SAFETY PLAN <br />SHEET P 1: LEVEL ONE AND TWO SANITARY PLAN <br />ADA FIXTURE DETAILS <br />FIRE SPRINKLER PLAN BY OTHER <br />MECHANICAL BY OTHER <br />�,,�,��' •'��C E NSF• .s0 <br />® � A <br />• <br />s • ' TATE OF = <br />• • <br />HANSON & HEADLEY <br />PROFESSIONAL ENGINEERS <br />ENGINEERING BUSINESS NO. EB6450 <br />PO BOX 1728 5290 S. ROMANS AVE. <br />DADE CITY, FL 33526 INVERNESS, FL 34452 <br />(352) 521-5848 (352) 726-2332 <br />