Laserfiche WebLink
3 <br />m <br />6- MIN. ABOVE FINISHED <br />GRADE ON SODDED <br />OR MULCHED AREAS ONLY <br />CONDENSATE DRAIN TERMINATION DETAIL. <br />NOT TO SCALE <br />�1.1:11�yiyl�l <br />IREFABRICATED <br />ZOOF CURB <br />ROOF EXHAUST FAN DETAIL <br />NOT TO SCALE <br />1%A►111C►1[4►1/% I I►Ilr <br />CONDENSING UNIT TIE DOWN <br />(MIAMI TECH, INC. CUTD1 <br />COLD -ROLLED GALV STEEL) <br />8 TOTAL FOR EACH UNIT <br />(1)1/4" DIA STAINLESS STEELSCREW <br />FROM STRAP TO CONDENSER <br />(1)3/16" DIA x 2" TAPCON <br />FROM STRAP TO CONC PAD <br />TYPICAL CONDENSING UNIT <br />ANCHORING DETAIL <br />NOT TO SCALE <br />GARAGE BUILDING MECHANICAL PLAN <br />SCALE: 1 /4" = 1'-0" <br />HVAC KEY NOTES <br />0 <br />1. MOUNT CU ON 4" THICK CONCRETE PAD. PAD <br />DIMENSIONS SHALL EXCEED CU DIMENSIONS BY 4' <br />ON ALL SIDES AND SHALL ALLOW FOR REFRIGERANT <br />PIPING STUB -UP. PLACE CU AWAY FROM ROOF DRIP <br />LINE. PROVIDE MANUFACTURER'S RECOMMENDED <br />CLEARANCES. ANCHOR CU'S SECURELY TO PAD WITH <br />4-3/4" LAG BOLTS AND OVERSIZED WASHERS. <br />LOCATION OF CU IS APPROXIMATE. COORDINATE <br />CLOSELY WITH LANDSCAPING PLANS AND <br />ARCHITECTURAL DETAILS. <br />2. REFRIGERANT LINES. ROUTE FROM AHU, BELOW <br />GRADE, AND UP THRU CU PAD. IN PVC CHASE, SEAL <br />CHASE ENDS WATERTIGHT INSIDE & OUT. INSULATE <br />SUCTION. <br />3. PVC CONDENSATE DRAIN LINE. ROUTE FROM AHU <br />BELOW GRADE TO JUST BEYOND EXTERIOR WALL. <br />4. EF-1: ROOF MOUNTED EXHAUST FAN WITH <br />BACKDRAFT DAMPER. <br />5. ROUTE 10x10 GALVANIZED STEEL DUCT UP TO EF-1 <br />ON ROOF. PROVIDE WITH BACKDRAFT DAMPER. SEE <br />VENT DETAIL ON THIS SHEET. <br />6. 18X18 INTAKE LOUVER EQUAL TO RUSKIN EME520D. <br />7. CONTRACTOR TO PROVIDE H2 SENSOR 1' BELOW <br />CEILING AND INTERLOCK TO EF-1. LE-1 WILL <br />ACTIVATE WHEN H2 LEVELS REACH 1 % TOTAL <br />VOLUME. <br />AIR CONDITIONING UNIT SCHEDULE <br />MARK <br />AHU-4/CU-4 <br />TYPE <br />STRAIGHT COOL <br />TOTAL COOLING CAP (MBH 0 ARI) <br />22.8 <br />SENSIBLE COOLING CAP. (MBH ® ARI) <br />- <br />AHU CONFIGURATION <br />WALL MOUNTED MINI SPLIT <br />SUPPLY AIR (CFM) <br />680 <br />OUTSIDE AIR (CFM) <br />- <br />EXTERNAL STATIC PRESS. (IN.WTR.) <br />- <br />EVAPORATOR FAN <br />MOCP <br />15 <br />VOLT/0 <br />240/1 <br />FLA <br />.4 <br />ELECTRIC HEAT <br />KW <br />- <br />VOLT/0 <br />- <br />STAGES <br />- <br />COMPRESSORS <br />NUMBER <br />1 <br />VOLT/O <br />240/1 <br />RLA/LRA (EA) <br />6.5/42.0 <br />STAGING (%) <br />0-100 <br />CONDENSER FAN <br />MOCP <br />20 <br />VOLT/0 <br />240/1 <br />MCA <br />11.6 <br />FLA (EA) <br />9.5 <br />AREA SERVED <br />PHONE ROOM <br />MANUFACTURER <br />CARRIER <br />AHU MODEL # <br />40BNCO24 <br />CU MODEL <br />38BNCO24 <br />MINIMUM EER OR SEER <br />14.0 SEER <br />OPERATING WEIGHT (AHU/CU) <br />150/200 <br />REMARKS <br />1-7 <br />NOTES: <br />1. REFRIGERANT LINES AND INSULATION SHALL BE SIZED AND INSTALLED IN STRICT ACCORDANCE WITH <br />MANUFACTURER'S RECOMMENDATIONS. PROVIDE SUBMITTALS ON INSULATION WITH EQUIPMENT SUBMITTALS. <br />2. MCA = MINIMUM CIRCUIT AMPACITY <br />3. EXTERIOR INTERLOCK WIRING BETWEEN AHU AND CU MUST BE RUN IN LIQUIDTITE FLEXIBLE CONDUIT. <br />4. TRANE OR JANITROL COMPUYING WITH DESIGN PARAMETERS ARE APPROVED EQUALS. <br />EXHAUST FAN SCHEDULE <br />FAN NO. <br />AIR <br />EXTERNAL <br />MOTOR <br />DRIVE <br />VOLT <br />NOTES <br />SUGGESTED <br />OR <br />SYMBOL <br />QUANITY, <br />CFM <br />STATIC, <br />IN WATER <br />(MM WATER) <br />POWER, <br />HP <br />RPM <br />B� <br />�D <br />BELTMANUFACTURERS <br />DIRECT <br />PH <br />(SEE SPECIFICATIONS) <br />MAKE <br />MODEL <br />EF-1 <br />550 <br />0.25 <br />1/15 <br />1411 <br />D <br />120/1 <br />1,2,3,4 <br />GREENHECK <br />G-090—D <br />NOTES: <br />1. PROVIDE WITH WHITE OR OFF—WHITE CEILING GRILLE. <br />2• PROVIDE WITH BACKDRAFT DAMPER. <br />3. PROVIDE CONTROL BY HYDROGEN SENSOR (H2). <br />4• PROVIDE WITH UNIT MOUNTED DISCONNECT <br />9 /LI <br />//1A1N-FL60785 <br />JOSE R. <br />SGM ENGINEERING, INC. <br />M E P C O N S U L T I N G E N G I N E E R S <br />935 Lake Baldwin Lane TEL:(407) 767-5188 <br />Baldwin Park, FAX:(407) 767-5772 <br />Orlando, Florida 32814 EB-00006208 <br />A(s,*Project number. 29122 <br />www.Sgmengineering.com <br />Copyright ©2009 SGM Engineering, Inc. <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrhills <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />SET DISTRIBUTIONS: <br />0 SHEET REVISIONS: <br />EDITED BY: <br />PROJECT NO. 09-2587 <br />Z <br />N <br />0 <br />Garage <br />E Mechanical Plan <br />Z <br />