Laserfiche WebLink
FASTEN 2X10 ROOF RAFTERS TO EXISTING <br />HOST WITH SIMPS❑N LU210 HANGERS, ATTAC <br />PER MANUFACTURERS SPECS <br />4 <br />N <br />2X 10 R❑❑F RAF `I.I> M, "L <br />2X4 DOUBLE vTOP uPLATE WITHuSIMSPON H2,5A, <br />ATTACH PER MANUFACTURERS SPECS, TYPICAL <br />ROUF RAFTER <br />PLA_lV <br />2X10 WOOD SUB ATTACHED TO-/ <br />EACH TRUSS WITH 8d COMMON <br />NAILS (3) EACH TRUSS <br />VINYL SOFFIT AND FASCIA <br />TRIM ATTACHED PER MANUF. SPECS. <br />FASTEN 1 /2" CDX OR OSB <br />WITH 8d COMMON NAILS @ <br />6" AT EDGES AND 8" O.C. <br />WALL SHEATHING <br />IN FIELD <br />APPLY TYVEK OR EQUAL HOUSE WRAP <br />PER MFGRS SPECIFICATIONS <br />APPLY SIDING TO MATCH EXISTING <br />PER MFGRS SPECIFICATIONS <br />I <br />2X10 ROOF RAFTERS @ 16" O.C. MAX <br />15/32" 4 PLY CDX OR OSB SHEATHING <br />FASTEN W/8d RING SHANK NAILS 6" O.0 <br />AND 12" INTERMEDIATE SPACING <br />USE STEEL PLYCLIPS. <br />30 YEAR WARRANTED FIBERGLASS <br />SHINGLES ON 30# FELT PAPER <br />APPLY PER MFGRS SPECIFICATIONS <br />INSTALL ROOFING PER MANUFACTURERS <br />FLASHING PER FBC—R 905 <br />EDGE <br />SPECIFICATIONS <br />ICYNENE SPRAY INSULATION R FACTOR PER ENERGY CALCS <br />ICYNENE IS A NON —VENTED INSULATION <br />FASTEN 2X10 ROOF RAFTER TO DOUBLE <br />2X4 DOUBLE TOP PLATE WITH SIMSP❑N H2,5A, <br />ATTACH PER MANUFACTURERS SPECS, TYPICAL <br />DOUBLE 2X4 TOP PLATE <br />- 1 �2" CEILING TYPE GYPSUM BOARD <br />A TACH ED WITH 5d COOLER NAILS <br />OR #8 DRYWALL SCREW AT 7" O.C. MAX <br />(2 2X4 TOP PLATE <br />W SIMPSON SP-2 EACH STUD <br />F 10456 <br />2X4 F�RE BLOCKING FASTEN TO STUD WALL <br />WITH 2) 16d COMMON NAILS TOE NAILED <br />1 /2" GYPSUM WALLBOARD <br />ATTACHED WITH 5d COOLER NAILS <br />OR #8 DRYWALL SCREW AT 7" O.C. MAX <br />2X4 STUDS @ 16" O.C. W/ R-13 INSULATION <br />-2X4 PT BOTTOM PLATE <br />W SIMPSON SP-1 EACH STUD <br />F 10456 <br />FASTEN 2X4 PT BOTTOM PLATE TO CONCRETE <br />SLAB WITH 1 /2"X5" WEDGE ANCHORS OR EQUIV. <br />4" CONCRETE (3000PS1) WITH #10 <br />6X6 MESH ON 6 MIL POLY <br />VAPOR BARRIER OVER CLEAN <br />COMPACTED POISON TREATED <br />SOIL. VAPOR BARRIOR <br />MATERIAL TO BE LAPPED <br />6 WITH SEAMS TAPED <br />FIBERMESH CAN BE SUBSTITUED <br />12"X20" CONCRETE FOOTER WITH �2)#5 „REBAR <br />REINF CONT. ON 3" CHAIRS SPAC D 48 O.C. <br />0 <br />a <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W. Smith, P.E. #53608 <br />