WOOD CONSTRUCTION, CONNECTIONS AND NAILING REQUIREMENTS SHALL CONFORM TO <br />THE 2020 FLORIDA BUILDING CODE. REFERENCE FASTENING SCHEDULE TABLE. <br />ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRY AND USED AT 19% MAXIMUM <br />MOISTURE CONTENT. <br />ALL LOAD BEARING WALL FRAMING SHALL BE NO.2 GRADE SOUTHERN PINE or SPF or P.T. <br />ALL JOIST AND RAFTER FRAMING SHALL BE NO.2 GRADE, SOUTHERN PINE OR HEM -FIR. <br />ALL FRAMING EXPOSED TO THE WEATHER OR IN CONTACT WITH MASONRY OR CONCRETE <br />SHALL BE PRESSURE -TREATED IN ACCORDANCE WITH THE AMERICAN WOOD PRESERVERS <br />ASSOCIATION SPECIFICATIONS. <br />BOLT HEADS SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE THAN 1/16" <br />LARGER THAN THE BOLT DIAMETER. BOLTED CONNECTIONS SHALL BE SNUGGED TIGHT <br />BUT NOT TO THE EXTENT OF CRUSHING WOOD UNDER WASHERS. <br />PREFABRICATED "MICRO -LAM" LUMBER HEADERS AND BEAMS SHALL AS MANUFACTURED <br />BY "TRUSS JOIST MacMILLIAN CORP." BOISE, IDAHO OR APPROVED EQUAL. <br />DO NOT CUT OR NOTCH MICRO -LAM MATERIAL WITHOUT THE MANUFACTURER'S APPROVAL. <br />8. PREFABRICATED METAL JOIST HANGERS, HURRICANE CLIPS, HOLD-DOWN ANCHORS AN <br />OTHER ACCESSORIES SHALL BE AS MANUFACTURED BY "SIMPSON STRONG TIE COMPANY", <br />OR EQUAL. INSTALL ALL ACCESSORIES AS PER THE MANUFACTURES REQUIREMENTS. ALL <br />STEEL SHALL HAVE A MINIMUM THICKNESS OF 0.04 INCHES (PER ASTM A446, GRADE A) AND <br />BE GALVANIZED (COATING G60). <br />ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN <br />PLYWOOD ASSOCIATION (APA) SPECIFICATIONS. <br />ALL ROOF PANEL SHEATHING SHALL BE 15/32" (1/2" NOM.) EXPOSURE-1 APA RATED <br />SHEATHING. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY USE OF PANEL CLI <br />OR BLOCKING BETWEEN FRAMING. SEE NAILING SCHEDULE. NOTE 4" O.C. NAILING <br />PATTERN WITHIN 48" OF ALL ROOF EDGES, RIDGES AND HIPS. OVER 1/2" NOMINAL <br />PLYWOOD, USE 10d NAILS. <br />INSTALL ALL PLYWOOD SHEATHING WITH THE LONG DIMENSION OF THE PANEL <br />ACROSS SUPPORTS AND WITH THE PANEL CONTINUOUS OVER TWO OR MORE <br />SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING AT PANEL ENDS AND <br />EDGES UNLESS OTHERWISE RECOMMENDED BY THE SHEATHING MANUFACTURER. <br />ALL NAILING SHALL BE CAREFULLY DRIVEN AND NOT OVERDRIVEN. THE USE OF <br />STAPLES ARE PROHIBITED. <br />GARAGE/ DWELLING PENETRATION PER FBC-R 2020 7TH EDITION (302): <br />MIN. 20 MINUTE RATED SOLID CORE DOOR BETWEEN GARAGE AND RESIDENCE. <br />DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING <br />SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A <br />MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MIN. RIGID NONMETALLIC <br />CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL <br />HAVE NO OPENINGS INTO THE GARAGE <br />DWELLING/GARAGE SEPARATION PER TABLE R302.6. <br />SEE PLAN SPECIFIC UL LISTING IF NEEDED <br />CONNECTION <br />FASTENER <br />BAND JOIST TO SILL OR TOP PLATE, TOE NAIL <br />12d <br />JOIST TO BAND JOIST, FACE NAIL <br />16d <br />JOIST TO SILL OR GIRDER, TOE NAIL <br />12d COMMON <br />BRIDGING TO JOIST, TOE NAIL EACH END <br />12d COMMON <br />LEDGER STRIP <br />16d COMMON <br />SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL <br />16d COMMON <br />TOP OR SOLE PLATE TO STUD, END NAIL <br />16d COMMON <br />STUD TO SOLE PLATE, TOE NAIL <br />8d COMMON <br />DOUBLED STUDS, FACE NAIL <br />10d COMMON <br />DOUBLED TOP PLATES, FACE NAIL <br />10d COMMON <br />TOP PLATES, LAP & INTERSECTIONS, FACE NAIL <br />CONTINUOUS HEADER, TWO PIECES <br />16d COMMON <br />CLG. JOISTS TO PLATE, TOE NAIL <br />12d COMMON <br />CONTINUOUS HEADER TO STUD, TOE NAIL <br />12d COMMON <br />CLG. JOISTS, LAPS OVER PARTITIONS, FACE NAIL <br />CLG. JOISTS TO PARALLEL RAFTERS, FACE NAIL <br />RAFTER TO PLATE, TOE NAIL <br />12d COMMON <br />1" BRACE TO EACH STUD & PLATE, FACE NAIL <br />8d COMMON <br />1 X 8 OR LESS SHTG TO EACH BEARING, FACE NAIL <br />8d COMMON <br />OVER 1 X 8 SHTG. TO EACH BEARING, FACE NAIL <br />8d COMMON <br />BUILT-UP CORNER STUDS <br />16d COMMON <br />BUILT-UP GIRDER & BEAMS, OF THREE MEMBERS <br />20d COMMON <br />STUDS TO SOLE PLATE, END NAIL <br />16d COMMON <br />TOP PLATE TO TRUSS OR FLOOR JOIST (PERPENDICULAR) <br />16d COMMON <br />TOP PLATE TO TRUSS OR FLOOR JOIST (PARALLEL) <br />16d COMMON <br />2" X 6" SUB FASCIA <br />10d COMMON <br />WOOD STRUCTURAL PANEL SUBFLOORING <br />NUMBER OR SPACING <br />12" O.C. <br />3 <br />2 <br />3 0 EACH JOIST <br />16" O.C. <br />2 <br />4 <br />24" O.C. <br />16" O.C. <br />2-16d OR 3-1 Od COMMON <br />16" O.C. ALONG EACH EDGE <br />3 <br />4-1 Od COMMON <br />3-16d OR 4-1 Od COMMON <br />3 <br />2 <br />2 <br />3 <br />16" O.C. <br />(3) ROWS, 12" O.C. STAGGERED <br />2 EACH END <br />2 EACH STUD <br />2 EACH STUD <br />(3) PER TRUSS TAIL <br />2020 FBC RESIDENTIAL SECTION R703.4 FLASHING <br />APPROVED CORRISION RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN A MANNER TO PREVENT ENTRY <br />OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURE FRAMING COMPONENTS. <br />SELF ADHERED MENBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION <br />PRODUCTS SHALL BE SEALED AT THE JUNCTION WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA <br />800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION. ASTM <br />C 1281 AAMA 812 OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. FLUID APPLIED <br />MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHINGS SHALL BE INSTALLED AT <br />THE FOLLOWING LOCATIONS. <br />1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL F*SH OR TO THE WATER RESISTANT BARRIER COMPLYING WITH SECTION <br />703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA <br />712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />MORE OF THE FOLLOWING. <br />1.1 THE FENESTRATION MANUFACTURERS INSTALLATION AND FLASHING INSTRUCTIONS OR THE APPLICATIONS <br />NOT ADDRESSED IN THE FENESTRATION MANUFACTURERS INSTRUCTIONS IN ACCORDANCE WITH THE <br />FLASHING MANUFACTURERS INSTRUECTIONS. WHERE FLASHING INSTRUCTIONS ORDETAILSARE NOT G <br />PROVIDEDHING SHALLI BE SHALL <br />ORNSLOPED IN SUCH AI MAONNER EXTERIOR <br />IOTO DIRECOTJ WATDER DOOR <br />RTHHEESURFACE <br />OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER FOR SUBSEQUENT DRAINAGE <br />OPENINGS USING PAN FLASHING SHALL BE INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES <br />MORE OF THE FOLLOWING. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS <br />1.4 IN ACCORDANCE WITH FMA/AMMA 100 FMA/AAMA 200 FMA/WDMA 250 FMA/AMMA/WDMA 300 <br />OR FMA AAMA/WDMA 400 <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS <br />3. UNDER AND AT THE ENDS OF MASONRY WOOD OR METAL COPINGS AND SILLS <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM <br />5. WHERE EXTERIOR PORCHES, DECKS AND STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME CONSTRUCTION <br />6. AT WALL AND ROOF INTERSECTIONS <br />7. AT BUILT-IN GUTTERS <br />2020 FBC RESIDENTIAL SECTION R704 SOFFITS <br />R704.1 WIND RESISTANCE OF SOFFITS <br />SOFFITSANDANDHR301A2(3)CFOR WALLS USING AN EFEECTIIVE RESISTING WIND <br />IOE 0 SQUARECFEIED IN TABLES <br />R704.2 SOFFIT INSTALLATION <br />SOFFIT INSTALLATION SHALL COMPLY WITH SECTIONS 704.2.1, R704.2.2, R704.2.3 AND R704.2.4 <br />R704.2.1 VINYL SOFFIT PANELS <br />VINYL SOFFIT PANELS SHALL BE INSTALLED USING FASTENERS SPECIFIED BY THE MANUFACTUR AND <br />SHALL BE FASTENED AT BOTH ENDS TO A SUPPORTING COMPONENT SUAS AS A NAILING STRIP, FASCIA, <br />OR SUBFASCIA COMPONENT IN ACCORDANCE WITH FIGURE R704,2,1. WHERE THE UNSUPPOTED SPAN OF <br />SOFFIT PANELS ISGREATER THAN 12 INCHES, INTERMEDIATE NAILING STRIPS SHALL BE PROVIDED IN <br />ACCORDANCE WITH FIGURER704.2.2 UNLESS A LARGER SPAN IS PERMITTED IN ACCORDANCE WITH THE <br />MANUFACTURERS ORIDUCT APPROVAL SPECIFICATION. VINYL SOFFIT PANELS SHALL BE INSTALLED IN <br />IN ACCORDANCE WITH THE MANUFACTURERS PRODUCTAPPROVAL SPECIFICATIONS AND LIMITATIONS OF USE. <br />FASCIA COVERS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS PRODUCT APPROVAL <br />SPECIFICATION AND LIMITATIONS OF USE. <br />R704.2.2 FIBER -CEMENT SOFFIT PANELS <br />FIBER -CEMENT SOFFIT PANELS SHALL BE A MINIMUM OF 1 /4" INCH THICK AND SHALL COMPLY WITH THE <br />REQUIREMENTS OF ASTM C1186. TYPE 1. MINIMUM GRADE III OR ISO 8336, CATEGORY A, MINIMUM CLASS 2. <br />PANEL JOINTS SHALL OCCUR OVER FRAMING OR OVER WOOD STRUCTURAL PANEL SHEATHING. SOFFIT <br />PANELS SHALL BE INSTALLED WITH SPANS AND FASTENERS IN ACCORDANCE WITH THE MANUFACTURERS <br />PRODUCT APPROVAL SPECIFICATION AND LIMITATIONS OF USE. <br />R704.2.3 HARDBOARD SOFFIT PANELS <br />WHERE THE DESIGN WIND PRESSURE IS 30 psf OR LESS, SOFFIT PANELS SHALL BE A MINIMUM OF <br />7.16 INCH IN THICKNESS AND SHALL BE FASTENED TO FRAMING OR NAILING STRIPS WITH 2-1/2"XO.113" <br />SIDING NAILS SPACED NOT MORE THAN 6 INCHES ON CENTER AT PANEL EDGES AND 12 INCHES ON CENTER <br />AT INTERMEDIATE SUPPORTS. WHERE THE DESIGN WIND PRESSURE IS GREATER THAN 30 psf, HARDBOARD <br />SOFFIT PANELS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS PRODUCT APPROVAL <br />SPECIFICATION AND LIMITATIONS OF USE. <br />R704.2.4 WOOD STRUCTURAL PANEL SOFFIT PRESCRIPTIVE ALTERNATIVE <br />WOOD STRUCTURAL PANEL SOFFIT PANELS ARE PERMITTED TO BE INSTALLED IN ACCORDANCE WITH <br />TABLE 704.2.4 <br />15W, 1/2", 7/16" <br />8d COMMON <br />6" <br />O.C. EDGES & 12" O.C. INTERMEDIATE <br />19/320, 3/4" <br />8d COMMON <br />6" <br />O.C. EDGES & 12" O.C. INTERMEDIATE <br />1", 1 1/8" <br />10d COMMON <br />6" <br />O.C. EDGES & 12" O.C. INTERMEDIATE <br />WOOD STRUCTURAL PANEL ROOF & WALL SHTG. <br />8d COMMON WALLS <br />1/2" OR LESS <br />8d RINSHANK ROOF <br />4" <br />O.C. EDGES & 6" O.C. INTERMEDIATE <br />19W - 314" <br />10d COMMON WALLS <br />1Od RINSHANK ROOF <br />4" <br />O.C. EDGES & 6" O.C. INTERMEDIATE <br />HARDBOARD LAP SIDING OVER SHEATHING <br />8d CORROSION RESISTANT <br />6" <br />O.C. AT EDGES & 12" O.C. <br />OR PER PRODUCT APPROVALS <br />W/MIN. SHANK DIAMETER OF <br />0.092" AT INTERMEDIATE <br />AND MIN. HD. DIAMETER OF 0.225" <br />STRUCTURAL LUMBER : <br />INTERIOR LOAD BEARING WALLS SPF #2 <br />ALL EXTERIOR FRAMING SPF #2 <br />ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER <br />ALL HEADER, BEAMS, COLUMNS ETC. TO BE SYP #2 OR BETTER <br />ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL <br />SHEATHING 15/32" EXP 1 OR 7/16" STRUCTURAL 1, U.N.O. <br />ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND <br />SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. <br />IF OSB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR <br />GREATER SECTION PROPERTIES. <br />ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION. WOOD IN <br />CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE <br />MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. <br />DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN <br />SPECI ICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />ANSI 1 1-2007, BCSI <br />UNTLLEAgTEED RWOVODDE�SH,gA�LL NOT BE IN DIRECT CONTACT WITH ECON�C�RpETPE..gSEEAST PLATES <br />ALL EXTERIOROFRAME WAgESR4HALL0CAT1I SS OTFINISH W07y8"N STUCCO FThPSH PER <br />�� C 2 PLY LLAL�ES WL BEp S�UCC <br />2 LAYERS9 36/8''PTH VEACH. R3RD /LAYET&L1 PjCfHNIRS 7/8" OVER METAL LATH. FIRST <br />INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 <br />PER FLORIDA CODE R703.7 <br />FASTENERS AND TIE DOWNS <br />FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES CHANNELS • ASTM A36/36M 05 Fy = 36 Ksi <br />ROUND METAL P0E : ASTM A53, GRADE B F = 35 Ksi <br />SQUARE METAL TUBING ASTM A500, GRADVB Fy = 46Ksi <br />HIGH STRENGTH BOLTS ASTM A325 <br />MACHINE BOLTS : GALVANIZED ASTM A307 <br />SHEET METAL ACCESSORIES SHALL CONFORM TO : Fy = 33KsiWITH G90 <br />GALVANIZED COATING IN ACCORDANCE WITH ASTM A525-87. <br />NAILS SHALL CONSIST QF : COMMON WIRE NAILS WITH MINIMUM DIAMETER AS <br />FOLLOWS : 8d = 0.131' 10d = 0.148", 12d = 0.148", 16d = 0.162". <br />ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE COATING BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />ALL FASTENER TIE DOWNS, BEAM HANGERS, JOIST HANGERS, AND FLOOR TRUSS <br />STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND <br />SPECIFICATIONS. <br />CONCRETE EMBEDDED 'J' BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS, U.N.O. ALTERNATES TO "J' BOLTS ARE NOTED ON PLANS. „ <br />CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. <br />NOTE: <br />GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD <br />FASTENING SHOULD BE TYPE "W" 1 1,4" DRYWALL SCREWS AT 12" O.C. FOR CEILINGS AND 1 <br />DRYWALL <br />SCREWS <br />p AT 1S2C"REO.C..�FOR SWALLS. ALL ENDS AND CERDEGESS O,gFC NWAGLLgBAEONR�DSSHALL <br />EDGES ItJ �/�I ALEAPPLICATION)0 SHUALPONTES6,�'M MOAT MIFIWSUPPOIRT. MINIMUM SCREW / <br />NAIL DISTANCE FROM EDGE SHALL BE '3" THIS SHALL APPLY TO BOTH CEILING AND WALL <br />INSTALLATION. DRYWALL SHIMS SHALL BE-USEDONLY WHERE NECESSARY. OPENINGS <br />CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED <br />ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITHOUT ADDITIONAL TAPING <br />OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING. <br />NOTE: <br />ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM <br />AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. <br />,0........ <br />.?� <br />STANDARD <br />HIP & RIDGE CUT <br />FROM METRIC <br />THREE TAB SHINGLES <br />� PREVAILING 5--\ <br />WIND DIRECTION <br />STANDARD <br />MANSARD OR <br />NORMAL WIND AREAS HIGH WIND AREAS <br />77 <br />0o <br />5" EXPOSURE <br />SHINGLE NAILING NOTES: <br />ALL NAILS MUST PENETRATE AT LEAST 3/4" INTO <br />THE WOOD ROOF DECK. <br />NAIL SHINGLES WITH 11 OR 12 GAUGE GALVANIZED NAILS <br />WITH 3/8" DIAMETER HEADS - 6 REQUIRED (AS SHOWN <br />IN "HIGH WIND AREAS") <br />ROOF -TO -WALL FLASHING NOTES: <br />4" X 5" ANGLE FLASHING - 26 GAUGE GALVANIZED METAL, <br />RUBBER VALLEY FLASHING OR 12" WIDE - 26 GAUGE <br />GALVANIZED METAL WITH SHINGLES OVER THE TOP. <br />MATERIAL SPECIFICATIONS: <br />UNDERLAYMENT SHALL CONFORM TO ASTM D226, TYPE I <br />OR ASTM 4869, TYPE I. <br />ENING FLASHING FOR ASPHALT SHINGLES SHALL COMPLY WITH <br />FBC R905.2.8 <br />ASPHALT SHINGLES SHALL COMPLY TO ASTM D225 OR <br />ASTM D3462. <br />VALLEY LINER <br />UNDERLAYMEN <br />2" <br />-6" MIN. <br />-EXTRA NAIL <br />ASPHALT PLASTIC <br />CEMENT <br />CLIP <br />CORNER <br />ROOF SHINGLE & FLASHING INSTALLATION SPECS - <br />FLASHING TAPE <br />POLYSTYRENE <br />MITER COVER <br />FLASHING TAPE <br />NOTE: <br />AN ADDITIONAL ROW OF TAPE IS WINDOW FLANGE <br />NEEDED IF THE TAPE IS TOO <br />NARROW TO COVER ALL EXPOSED <br />NAILS IN THE NAILING FLANGE. <br />POLYSTYRENE <br />MITER COVER <br />WINDOW FLASHING NOTES: <br />STEP #1 CAULK WINDOW OPENING EDGE PRIOR TO <br />SETTING WINDOW. <br />STEP #2 HOUSEWRAP TAPED TO FLANGE BOTTOM. <br />STEP #3 CUT HOUSEWRAP DIRECTLY ABOVE NAILING <br />FLANGE & OVERSIZE CUT 6" BOTH SIDES OF <br />WINDOW FLANGE. <br />STEP #4 COVER OPEN NAILING FLANGE MITER W/RED <br />HOUSEWRAP TAPE. <br />STEP #5 INSTALL FLASHING TAPE 2 SIDES WITH TOP OF <br />TAPE FLASHED UNDER HOUSEWRAP. <br />WINDOW FLASHING DETAIL <br />NOT TO SCALE <br />NOT TO SCALE <br />WINDOW FLANGE <br />WINDOW <br />WINDOW FLANGE <br />FLASHING TAPE <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W. Smith, P.E. #53608 <br />