GENERAL STRUCTURAL NOTES: <br />BUILDING CODES AND SPECIFICATIONS <br />1. Florida Building Code, 2007 Edition with 2009 Supplement <br />2. Building Code Requirements for Reinforced Concrete ACI 318-02 <br />3. Building Code Requirements for Masonry Structures ACI 530-02/ <br />ASCE 5-02/TMS 402-02 <br />4, Specification for Structural Steel Buildings, AISC 9th Edition, <br />5, Structural Welding Code D1L1 (American Welding Society) <br />DESIGN LOADS <br />1, Live Loads: <br />Timber Walk .......... 80 PSF <br />Modulars..................40 PSF <br />2, Wind Loadl <br />Design Wind Speed, 120 MPH <br />FBC 2007, SECTION 1609 <br />3. Dead Loadst <br />None <br />4. Other Loads: <br />Contractor shall submit cut sheets for all equipment including but not <br />limited to hvac package units, air handlers, generators and chillers. <br />Information shall include weight and any special support requirements, <br />DRAWINGS AND SPECIFICATIONS <br />1, Do not scale these drawings for dimensions not given. <br />2. Advise Architect of dimensional discrepancies between architectural <br />and structural drawings prior to commencing construction of affected elements, <br />3. Verify all existing field conditions and dimensions prior to commencing <br />construction, <br />4. These drawings are intended to be used in conjunction with those of other <br />trades including but not limited to architectural, mechanical, civil, etc. <br />Refer to drawings of other trades for details relating to the structural <br />components. <br />5. The Contractor shall carefully study and compare the Contract Documents <br />and shall at once report to the Architect any error, inconsistency or omission <br />he may discover. Bring any conflicts to the attention of the Architect for <br />resolution prior to commencing work on items affected, <br />6. The intent of the Contract Documents is to include all items necessary <br />for the proper execution and completion of the work, The Contract Documents <br />are complementary, and what is required by any one shall be as binding as if <br />required unless it is consistent therewith and is reasonably inferable therefrom <br />as being necessary to produce the intended results. <br />7. In the case of conflicting information, the Contractor shall assume the <br />more costly alternate, unless directed otherwise in writing. <br />8. I the case of ambiguous or missing information, the Contractor shall <br />assume a member size, quantity or quality consistent with similar areas in <br />the project, unless directed otherwise in writing, <br />9. The Contractor shall not be compensated for the addition of structural <br />components when the omission, mislabeling or other deficiency should <br />have been noted during the Bidding phase, and brought to the Architects <br />attention, <br />10, The Contractor shall perform no portion of the work at any time <br />without Contract Documents or, where required, approved shop drawings, <br />product data or samples f or such portion of the work, <br />SHOP DRAWINGS <br />1. No structural drawings shall be reproduced for use as shop drawings, <br />2. All dimensional coordination shall be done by the Contractor and/or his <br />detailer <br />3. Detailer shall check all drawings f or all attachments, clips, openings or <br />other work affecting structural members. <br />All items shall be shown on shop drawings, <br />4. Shop drawings shall be submitted to allow sufficient time for processing, <br />Six (6) sets of shop drawings shall be submitted f or review, <br />5. Provide sufficient space on shop drawings near title box for stamps and <br />comments, <br />6. The shop drawings shall bear initials of detailer's checker and contractor prior <br />to submission. <br />7. Completed erection plans shall be submitted prior to or in conjunction with <br />detail drawings. But in no case shall detail drawings be submitted <br />prior to erection plans, <br />8. Contractor shall have shop drawings which have been satisfactorily reviewed <br />by the Architect and/or Engineer and confirmed b the Contractor <br />before proceeding with any work, <br />CONSTRUCTION SAFETY <br />1, These drawings do not include provisions to satisfy safety <br />requirements, Contractor is solely responsible for ensuring safety during <br />construction, and for conformance to all applicable OSHA Standards, <br />Job site visits by Engineer shall not constitute approval, awareness or <br />liability for any hazardous conditions. <br />2. Do not overload one segment or span of a beam continuous over several <br />supports. Beams should be loaded as gradually and evenly as possible until <br />the full load is in place. <br />3. Erection sequence shall be determined by the Contractor, and shall not <br />cause over stress or excessive deformation of structural members. <br />VALUE ENGINEERING <br />1. Any changes to the structure shall have been reviewed and approved in <br />writing by the Architect prior to commencing work on items affected. <br />FIELD M❑DIFICATI❑NS <br />1. Any changes to the structure shall have been reviewed and approved in <br />writing by the Architect prior to commencing work on items affected. <br />2. Any changes made without prior approval are subject to review by the <br />Architect, Contractor shall provide sketches, photographs and written <br />description of each deviation from the plans for the Architect's review, <br />FOUNDATIONS <br />1. Maximum net soil bearing pressure used for design ........ 2500 PSF <br />2, Notify Architect if footing excavation reveals unsuitable or unstable <br />soils, or materials or conditions not previously anticipated, <br />3. Consider the possible impact of groundwater on construction techniques, <br />using seasonal variations, any other site indicators and your <br />own judgment. <br />PORTLAND CEMENT CONCRETE <br />1, Concrete Quality and Placement: <br />Foundations and walls, 3000 psi, 3' to 5' slump <br />Filled cells in block, 2500 psi, 8' to 11' slump, 3/8' pea gravel <br />Slabs on Grade, 3000 psi, 3' to 5' slump <br />a. Fly ash shall not exceed 20 per cent by weight of total <br />cement content, if used, <br />b. Slump limits shall be strictly adhered to, Use superplasticizer <br />to increase workability, at contractors option. <br />c. Maximum mixing time (from batching to placement) <br />Air temp less than 85°F, 90 minutes <br />Air temp 85°F to 90°F, 75 minutes <br />Air temp over 90°F, 60 minutes <br />d. Mix design shall be submitted for approval. <br />e. Concrete cylinder testing & reports are to be furnished by subcontractor. <br />2, Minimum Coveri <br />a, Footings, 3 in, to bottom and unformed sides, 2 in, to formed sides <br />b. Other, 2 in, to main reinforcing, 1 1/2 in, to ties and stirrups <br />3. Coordinate drawings of all trades f or required embeds, openings and <br />accessories not shown herein, <br />4. All reinf orcement shall be securely held in place by standard accessories <br />during concrete placement, <br />5. Bars shall be grade 60 conforming to ASTM A615, <br />6. Welded Wire Fabric shall conf orm to ASTM A185, <br />7. Detail and fabricate reinforcement in accordance with 'Manual of Standard <br />Practice f or Detailing Reinf orced Concrete Structures', ACI 315. <br />8. Provide minimum lap splice of 30 bar diameters, but not less than 24 <br />Inches, for all reinforcing bars, unless noted otherwise, Stagger splices in <br />adjacent bars at least 24 inches, except in beans and columns, <br />9. In wall f ootings, grade beams and bond beams, provide bent bars at <br />corners and intersections of the same number and size as the straight bars, <br />10. Exposed edges of beams and columns shall be chamfered 3/4 in, u,n.o. <br />11. See architectural drawings for locations of anchor slots in columns, <br />beams and concrete slabs, <br />CONCRETE SLAB ON GRADE <br />1. Intended usage is for pedestrian traffic only, <br />2, Compressive Strength at 28 days ..... 3000 psi <br />3. Minimum thickness ..... 4 in. <br />4. Maximum slump at point of delivery ..... 4 in, <br />5. Maximum aggregate size ..... 1 in, <br />6. Entrained air content ..... 4.5% <br />7. Fill saw cuts with elastomeric sealant after cleaning with compressed air, <br />8, Welded Wire Fabric shall be WWF 6x6-W1.4xW1,4 in flat sheets, unless <br />otherwise noted, conforming to ASTM A185, <br />9. Place Welded Wire Fabric centered in depth of slab -on -grade unless noted <br />otherwise, Lap all mesh joints two full meshes, <br />10. Interrupt typical slab reinforcement at all construction and expansion <br />joints, See specific details for any dowels required for shear transfer, <br />11. Cut every other wire along the line of saw cut control joints prior to <br />placing concrete, Make saw cuts within 12 hours of concrete placement, or <br />as soon as cuts can be made without raveling. <br />12. Provide 1/2 in, preformed expansion joint material where slab abuts <br />vertical surfaces such as walls and columns. <br />13. See architectural drawings for exact locations of depressed areas in <br />slabs which are not shown or dimensioned on structural drawings. <br />14. Provide 6 mil vapor barrier under all stab -on -grade in enclosed space. <br />15. Apply curing compound to slab within two hours of completion of finishing <br />operations, Use liquid membrane forming compound complying with ASTM C309 <br />Type 1 Class A, Follow manufacturers instructions, <br />16, Confirm that curing compound will not interfere with bonding of any <br />applied floor surface. If so, use wet burlap and trickle hoses, <br />17, It is recommended that the slabs be cast in long strips, and saw cut <br />transversely, in order to minimize shrinkage cracking. <br />CARPENTRY <br />1. ALL LUMBER SHALL BE SOUTHERN PINE No, 2. GRADE OR BETTER, WITH 19% MAXIMUM <br />MOISTURE CONTENT, <br />2. ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE, OR EXPOSED TO WEATHER, <br />SHALL BE PRESSURE TREATED, <br />3, PRESSURE TREATED LUMBERS SHALL COMPLY WITH AWPA C2 FOR LUMBER AND <br />TIMBERS AND AWPA C9 FOR PLYWOOD, USE PRESERVATIVE WITH 0,25 PCF RETENTION <br />FOR ABOVE GROUND AND 0,40 PCF FOR FRESH WATER OR S❑IL CONTACT USE, <br />4, MINIMUM FINISH REQUIREMENTS FOR METAL CONNECTORS AND FASTENERS: <br />A. INTERIOR EXPOSURE - GALVANIZED (G90). <br />B, EXTERIOR EXPOSURE - PRESSURE TREATED GALVANIZED (13185), HOT DIP <br />GALVANIZED (HDG), OR STAINLESS STEEL (SST300), <br />ZONES <br />a = 3.0 FT <br />NET WIND LOADS <br />FLOOR <br />JOIST <br />COMPONENTS <br />ROOF ZONE <br />1 <br />2 <br />3 <br />AND CLADDING <br />MSSUIRE (paf) <br />9b <br />153 <br />153 <br />VERT. COMP. <br />U <br />U <br />9b <br />HORIZ COMP. <br />- <br />- <br />- <br />SUCTION (paf) <br />-5B <br />-213 <br />-213 <br />PERT. COMP. <br />-15.8 <br />-213 <br />-213 <br />HORIZ COMP. <br />- <br />- <br />- <br />NET WIND LOADS <br />FLOOR REAMS <br />COMPONENTS <br />ROOF ZONE <br />1 <br />2 <br />3 <br />AND CLADDING <br />PIREftm (paf) <br />9b <br />9b <br />9b <br />VERT. COMP. <br />9b <br />Sb <br />Sb <br />HORIZ COMP. <br />- <br />- <br />- <br />SUCTION (pet) <br />-158 <br />-158 <br />-15.8 <br />VERT. COMP. <br />-158 <br />-15.8 <br />-158 <br />14ORIZ COMP. <br />- <br />- <br />- <br />GROSS WIND LOADS <br />FLOOR DECK <br />COMPONENTS <br />ROOF ZONE <br />i <br />2 <br />3 <br />AND CLADDING <br />PRESSUIRE (paf) <br />9b <br />153 <br />153 <br />VERT. COMP. <br />U <br />153 <br />153 <br />HORIZ COMP. <br />- <br />- <br />- <br />SUCTION (paf) <br />-23.0 <br />-34.5 <br />.34.5 <br />VERT. COMP. <br />-23D <br />-345 <br />.345 <br />HORIZ C 10. <br />- <br />- <br />- <br />TERMITE PROTECTION NOTES: <br />I. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE <br />TREATMENT PROVIDER AND NEED FOR RE-IN5PEGTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. <br />THE SIGN SHALL BE P05TED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL. <br />2. CONDENSATE AND ROOF DOWN5POUT5 SHALL D I5CHARGE <br />AT LEAST I'-0" AWAY FROM BUILDING SIDE WALLS. <br />3. IRRIGATIOWSPRINKLER 5Y5TEM5 INGLUDING ALL RISERS <br />AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN I'-0" <br />OF THE BUILDING SIDE WALLS. <br />4. INITIAL TERMITE TREATMENT SHALL BE DONE AFTER ALL <br />EXCAVATION AND BAGKFILL 15 COMPLETE. 501L DISTURBED <br />AFTER THE INITIAL TREATMENT SHALL BE RETREATED, <br />INGLUDING SPACES BOXED OR FORMED. <br />5. BOXED AREAS IN CONCRETE FLOORS FOR 5UB5EGUENT <br />INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH <br />PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A 51ZE AND DEPTH THAT WILL ELIMINATE <br />THE DISTURBANCE OF 501L AFTER THE INITIAL TREATMENT. <br />6. MIN. 6 MIL VAPOR RETARDER MUST BE INSTALLED TO <br />PROTECT AGAINST DILUTION. IF RAINFALL OCCURS BEFORE <br />VAPOR RETARDER PLACEMENT, RETREATMENT 15 REQUIRED. <br />1. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION <br />PERIMETER MUST BE REMOVED BEFORE EXTERIOR 501L <br />TREATMENT 15 PLACED. <br />8. 501L TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR <br />CONCRETE OR GRADE WITHIN 1'-0" OF THE STRUCTURE <br />51DEWALL5. <br />a. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE <br />INSTALLED AFTER CONSTRUCTION 15 COMPLETE INGLUDING <br />LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED SHALL BE RETREATED. <br />10. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-GONSTRUGTION <br />TREATMENT. <br />I1. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE <br />BUILDING DEPT. BY A LICENSED PEST CONTROL COMPANY <br />BEFORE A CERTIFICATE OF OGGUPANGY WILL BE ISSUED. THE <br />CERTIFICATE OF COMPLIANCE SHALL STATE: THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION <br />OF SUBTERRANEAN TERMITES. THE TREATMENT IS IN <br />ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRIGULTURE AND CONSUMER SERVICES. <br />12. AFTER ALL WORK 15 COMPLETED, L005E WOOD AND FILL <br />MUST BE REMOVED FROM BELOW AND WITHIN 1'-0" OF THE <br />BUILDING. THI5 INCLUDES ALL GRADE STAKES, TUB TRAP BOXES, <br />FORMS, SHORING OR OTHER GELLUL05E GONTAINING MATERIAL. <br />13. NO WOOD, VEGETATION, 5TUMP5, CARDBOARD, TRASH, ETC., SHALL <br />BE BURIED WITHIN 15-0" OF ANY BUILDING OR PROPOSED BUILDING. <br />'= <br />'0 <br />MET <br />t <br />v <br />MaJ <br />0.4-28-2011 <br />0 <br />m <br />C <br />m <br />Q <br />ci <br />C <br />ai <br />}• <br />G <br />.0 <br />r� <br />a <br />a� <br />N <br />U <br />D <br />0 <br />-U <br />N <br />O <br />r <br />, w <br />Lo <br />�=M <br />cd <br />cd <br />W <br />O <br />c <br />m <br />v <br />=VM <br />� <br />V <br />L <br />M <br />1 <br />2 <br />3 <br />SHEET <br />S-i <br />oF 2 <br />i <br />