Laserfiche WebLink
21 <br />NOTESLANDSCAPE MATERIALS LEGEND BUFFER TREES ARE INCLUDED IN THE REQUIRED <br />NUMBER OF TREES TO BE PROVIDED FOR TREE REPLACEMENT <br />1. SOD ALL AREAS SPECIFICALLY NOTED ON THE PLANS. INSTALL ST. AUGUSTINE 'FLORATAM' <br />SOD ONLY AT LAWN AREAS BEING IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM AS <br />SHOWN ON THE IRRIGATION PLANS. ALL OTHER LAWN AREAS DISTURBED BY <br />CONSTRUCTION SHALL BE SODDED WITH ARGENTINE BAHIA SOD INCLUDING AREAS WITHIN <br />RIGHT-OF-WAY DAMAGED BY CONSTRUCTION. HOLD BACK SOD (6) FEET FROM THE <br />TRUNKS OF EXISTING TREES TO BE PRESERVED. <br />2. MULCH ALL PLANTING BEDS AND AROUND INDIVIDUAL TREES TO A MINIMUM DEPTH OF 3 <br />INCHES WITH AN APPROVED ORGANIC MULCH. <br />3. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO STARTING WORK IN <br />COMPLIANCE WITH LOCAL AND STATE LAWS. <br />4. WHERE TWO OR MORE ROWS OF PLANTS ARE SIDE BY SIDE IN THIS DESIGN, IT IS THE <br />INTENT THAT ROWS BE STAGGERED IN A TRIANGLE TO COMPLY WITH LOCAL <br />REQUIREMENTS, IF APPLICABLE. <br />5. ROOT PRUNING OF EXISTING TREES SHALL BE ACCOMPLISHED PRIOR TO THE START OF <br />ANY WORK ON THIS PROJECT, IF EXISTING TREES ARE PRESENT WHICH ARE IDENTIFIED AS <br />REQUIRING ROOT PRUNING. <br />6. PRUNING OF NEW & EXISTING TREES SHALL BE PERFORMED IN ACCORDANCE WITH THE <br />ANSI A 300 PRUNING STANDARDS OF THE AMERICAN NATIONAL STANDARDS INSTITUTE <br />(ANSI). GRAND TREES SHALL BE PRUNED ONLY BY AN ARBORIST CERTIFIED BY THE <br />INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA) OR A REGISTERED CONSULTING <br />ARBORIST WITH THE AMERICAN SOCIETY OF CONSULTING ARBORISTS (ASCA). A <br />NOTARIZED AFFIDAVIT AFFIRMING AN ISA CERTIFIED ARBORIST OR AN AXCA REGISTERED <br />CONSULTING ARBORIST SHALL BE SUBMITTED TO CITY OF ZEPHYRHILLS PRIOR TO THE <br />PRUNING OF A GRAND OAK. <br />7. CONTRACTOR SHALL BARRICADE ALL EXISTING TREES IN ACCORDANCE WITH CITY OF <br />ZEPHYRHILLS CODES. SEE SHEET L104 FOR DETAILS AND PLACEMENT. <br />8. IT SHALL BE UNLAWFUL TO UNDERTAKE THE FOLLOWING ACTIVITIES WITHIN THE DRIP <br />LINE OF AN EXISTING TREE REMAINING ON THE SITE, UNLESS OTHERWISE APPROVED BY <br />THE CITY OF ZEPHYRHILLS; REMOVE VEGETATION, EXCEPT BY HAND, OR PLACE SOIL <br />DEPOSITS, DEBRIS, SOLVENTS, CONSTRUCTION MATERIAL, MACHINERY OR OTHER <br />EQUIPMENT OF ANY KIND, OR UNDERTAKE ANY OTHER LAND ALTERATION OR <br />CONSTRUCTION ACTIVITY WHICH WOULD CAUSE THE TREE TO DIE WITHIN A PERIOD OF <br />TWO YEARS. <br />9. ALL TREE ROOTS EXISTING WITHIN APPROVED IMPROVEMENT AREAS AND ORIGINATING <br />FROM A PROTECTED TREE SHALL BE SEVERED CLEAN AT THE BOUNDARY OF THE AREA TO <br />BE PRESERVED AROUND THE TREE. <br />10. ALL PLANTS AND TREES SHALL CONFORM TO THE STANDARD FOR GRADE #1 OR BETTER AS <br />GIVEN IN THE LATEST "GRADES AND STANDARD FOR NURSERY PLANTS, PARTS 1 AND 11, <br />"FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES OR THE THE <br />STANDARDS AS GIVEN BE FLORIDA #1 OF BETTER IN ACCORDANCE WITH ' GRADES AND <br />STANDARDS FOR NURSERY STOCK," AMERICAN NATIONAL STANDARDS INSTITUTE. <br />11. WARNING: UNDERGROUND AND/OR ABOVE GROUND UTILITIES MAY BE IN THE AREA OF THIS <br />PROJECT. PROCEED WITH CAUTION. CALL 811 SUNSHINE UTILITY NOTIFICATION CENTER <br />TWO DAYS BEFORE ANY EXCAVATION IS TO BE UNDERTAKEN. <br />12. ALL CONSTRUCTION SHALL COMPLY TO ALL APPLICABLE CODES, ORDINANCES AND <br />REGULATIONS OF CITY OF ZEPHYRHILLS, FLORIDA. <br />13. EXCAVATE ALL DELETERIOUS SOILS WHERE DISCOVERED WHICH WOULD BE HARMFUL TO <br />HEALTHY PLANT AND TREE GROWTH SUCH AS LIME ROCK, CLAYS, JUNK, DEBRIS, ROCKS, <br />STONES ETC. TO A DEPTH OF 24" FROM FINISH GRADE OR AS DETAILED FOR EXCAVATION <br />FOR PLANT AND BALL PITS FOR NEW TREES AND SHRUBS, NOTIFY THE LANDSCAPE <br />ARCHITECT IMMEDIATELY OF ANY DETRIMENTAL SOILS, GROUND WATER, OR UTILITY <br />CONFLICTS OR ANY OTHER ADVERSE CONDITIONS WHICH ARE DISCOVERED PRIOR TO <br />PLANTING ANY TREES FOR SHRUBS. FURNISH PLANTING SOIL AS SPECIFIED AND/OR <br />DETAILED. DISPOSE OF EXCAVATED DELETERIOUS MATERIALS OFF -SITE IN A LEGAL <br />MANNER. <br />14. FURNISH AND INSTALL NEW APPROVED HUMIC TOPSOIL PLACED IN 6" LIFTS, <br />SEMI -COMPACTED AND LEVELED OFF 3" BELOW TOP OF CURB OR PAVEMENT EDGE. DO <br />NOT EXCAVATE NEAR EXISTING TREES OR EXISTING PAVEMENTS SUCH THAT PAVEMENT <br />CAN BE WEAKENED AND STRUCTURALLY COMPROMISED, <br />15. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. <br />16. LANDSCAPE CONTRACTOR SHALL SUBMIT A SOIL ANALYSIS TO THE LANDSCAPE <br />ARCHITECT FOR THOSE AREAS RECEIVING NEW PLANTINGS AND LAWN PRIOR TO <br />COMMENCEMENT OF CONSTRUCTION. <br />17. FERTILIZER REQUIREMENTS AS SPECIFIED OR NOTED ON THE PLANS SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR, <br />18. AN AUTOMATIC UNDERGROUND IRRIGATION SYSTEM SHALL BE PROVIDED FOR THE <br />PROPOSED LANDSCAPE AND SHALL COMPLY WITH ALL CITY OF ZEPHYRHILLS CODES AND <br />REGULATIONS. WATER SOURCE SHALL BE DOMESTIC WATER METER OR AS SHOWN NOTED <br />ON PLANS. <br />19. CONTRACTOR SHALL PREPARE AND INSTALL WETLAND MITIGATION PLANTINGS BY <br />BY OBTAINING ALL NECESSARY PERMITS FROM SWFWMD AND OTHER REQUIRED <br />PERMITTING AGENCIES. PREPARE PLANTING AREAS BY REMOVING INVASIVE SPECIES IF <br />PRESENT, CLEANING PLANTING AREA OF DELETERIOUS MATERIALS, HAND GRADING AND <br />OTHER APPROVED MEANS NECESSARY IN THE PROPER INSTALLATION OF PLANT AND TREE <br />MATERIALS. <br />20. THE OWNER SHALL WATER AND MAINTAIN WETLAND PLANTINGS SUFFICIENT TO ESTABLISH <br />THE PLANTINGS TO A QUALITY OF GOOD HEALTH AND SURVIVAL FOR A PERIOD OF ONE. <br />YEAR AFTER PLANTING. A HOSE BIB IS TO BE UTILIZED AS SHOWN ON THE IRRIGATION <br />PLAN. WETLAND PLANTINGS SHALL BE INSPECTED BY SWFWMD AT THE END OF THE ONE <br />YEAR ESTABLISHMENT PERIOD. <br />21. THE CONSTRUCTION OF ALL ABOVE GROUND UTILITY APPURTENANCES VISIBLE <br />FROM THE PUBLIC RIGHT-OF-WAY SUCH AS PEDESTALS, UTILITY METERS, TRANSFORMERS, <br />BACK -FLOW PREVENTION DEVICES, ETC, FOR NEW DEVELOPMENT OR REDEVELOPMENT <br />ACTIVITIES SHALL CONFORM TO SCREENING REQUIREMENTS AS OUTLINED IN SECTIONO OF <br />THE CITY OF ZEPHYRHILLS LAND DEVELOPMENT CODE. PLANT LOCATION MUST BE <br />CONSIDERATE OF REQUIRED SPATIAL SEPARATIONS FROM A FIRE FLOW PROTECTION <br />APPLIANCE IN ACCORDANCE TO THE UNIFORM FIRE CODE. <br />22. ALL AREAS SUBJECT TO EROSION SHALL BE STABILIZED WITH ARGENTINE BAHIA SOD <br />GRASS. INSTALL BAHIA GRASS TO ALL AREAS WHERE SOILS ARE PRONE TO EROSION AND <br />WHERE SLOPES ARE GREATER THAN 5:1. <br />23. CONTRACTOR SHALL COMPLY WITH THE CITY OF ZEPHYRHILLS LAND DEVELOPMENT CODE <br />TO MINIMIZE SOIL EROSION PROPOSED LAND ALTERATION ACTIVITIES. CONTRACTOR <br />SHALL NOT UNNECESSARILY REMOVE EXISTING VEGETATION AND ALTER EXISTING <br />TOPOGRAPHY. ADEQUATE PROTECTION MEASURES (I.E. HAY BALES, BAFFLES, SODDING <br />AND SANDBAGGING) SHALL BE PROVIDED, AS NECESSARY, TO MINIMIZE EROSION AND <br />DOWNSTREAM SEDIMENTATION CAUSED BY SURFACE WATER RUN-OFF ON EXPOSED LAND. <br />LANDSCAPE MAINTENANCE <br />ALL LANDSCAPING, INCLUDING THOSE AREAS LOCATED IN THE PUBLIC <br />RIGH-OF-WAY AS APPROVED THROUGH THE APPLICABLE DEVELOPMENT <br />REVIEW PROCESS, SHALL BE MAINTAINED BY AN ENTITY OTHER THAN THE <br />CITY. <br />THE LANDSCAPE MAINTENANCE PLAN AND SCHEDULE SHALL BE SUBMITTED <br />AS A PART OF THE ORDINANCE SHALL BE UTILIZED TO DIRECT THE <br />ON -GOING MAINTENANCE OF THE LANDSCAPING AND IRRIGATION. <br />ALL REQUIRED LANDSCAPING SHALL BE MAINTAINED IN A HEALTHY <br />CONDITION IN PERPETUITY AS PER THE APPROVED LANDSCAPE PLAN <br />ALL INSTALLED LANDSCAPING SHALL BE NEAT AND ORDERLY IN <br />APPEARANCE AND KEPT FREE OF REFUSE, DEBRIS, DISEASE, PESTS AND <br />WEED AND SHALL BE FERTILIZED AND IRRIGATED TO MAINTAIN PLANTS IN A <br />HEALTHY CONDITION. <br />ON -GOING MAINTENANCE TO PREVENT THE ESTABLISHMENT OF PROHIBITED <br />EXOTIC SPECIES IS REQUIRED. <br />ANY PLANT MATERIALS OF ANY TYPE AND KIND REQUIRED BY THESE <br />REGULATIONS SHALL BE REPLACE WITHIN 30 DAYS OF THEIR DEMISE <br />AND/OR REMOVAL. <br />PAVING, TREATING OR COVERING A REQUIRED LANDSCAPED AREA IN ANY <br />WAY THAT RENDERS IT IMPERVIOUS IS PROHIBITED, <br />PARKING OF VEHICLES SHALL NOT BE PERMITTED IN REQUIRED <br />LANDSCAPED AREA. <br />IT SHALL BE THE RESPONSIBILITY OF OF THE CONTRACTOR TO REMOVE <br />ANY DEAD, DISEASED OR DANGEROUS TREES OR SHRUBS OR PARTS <br />THEREOF, WHICH OVERHANG OR INTERFERE WITH TRAFFIC CONTROL <br />DEVICES OR PUBLIC SIDEWALKS. <br />ALL PRUNING SHOULD BE ACCOMPLISHED ACCORDING TO HORTICULTURAL <br />STANDARDS. TREES SHOULD BE PRUNED ONLY AS NECESSARY TO <br />PROMOTE GOOD HEALTH. TREES MAY BE PERIODICALLY PRUNED OR <br />THINNED IN ORDER TO REDUCE LEAF MASS IN PREPARATION FOR TROPICAL <br />STORMS. ALL PRUNING SHALL BE ACCOMPLISHED BY A CERTIFIED <br />ARBORIST IN ACCORDANCE WITH NATIONAL ARBORISTS STANDARDS. <br />IRRIGATION <br />SYSTEM LEGEND <br />SYMBOL <br />DESCRIPTION <br />RADIUS <br />ARC <br />PSI <br />GPM <br />HUNTER PCB-05 BUBBLER NOZZLE (TRICKLE) WITH RETRACTABLE <br />FLOOD <br />40 <br />0.50 <br />RISER (TREE BUBBLER); 2 PER TREE <br />0 <br />HUNTER MPR40-12-CV-MPCORNER 12" POP-UP SPRINKLER (ADJ 45-105 DEGREE) <br />45 DEG <br />40 <br />.19 <br />HUNTER MPR40-12-CV-MP2000 12" POP-UP SPRINKLER <br />O <br />90 DEG <br />40 <br />.19 <br />C <br />INSTALLED IN EDGE OF SHRUB BED AREAS <br />120 DEG <br />180 DEG <br />40 <br />40 <br />.40 <br />.74 <br />3 <br />8'-15' ADJ. ARC <br />210 DEG <br />40 <br />.86 <br />270 DEG <br />40 <br />1.10 <br />13'-21' RADIUS <br />360 DEG <br />40 <br />1.47 <br />HUNTER MPR40-12-CV-MPSS530 SIDE STRIP 12" POP-UP SPRINKLER <br />SIX 30' CTR <br />RECT. <br />40 <br />.44 <br />S <br />HUNTER MPR40-12-CV-MPLCS515 LEFT STRIP 12" POP-UP SPRINKLER <br />5' X 15' RT <br />40 <br />22 <br />® S <br />HUNTER MPR40-12-CV-MPRCS515 RIGHT STRIP 12" POP-UP SPRINKLER <br />5' X 15' LFT <br />40 <br />.22 <br />S[3 <br />INSTALLED INSIDE THE EDGE OF SHRUB BED AREAS <br />GATE VALVE; NIBCO-SCOTT T-113 BRASS GATE VALVE IN METER SIZE VALVE BOX <br />SIZE AS NOTED <br />WITH LID; BROOKS, AMETEK OR APP'D EQUAL <br />VALVE SHALL FUNCTION AS MAIN SHUT OFF OR ISOLATION VALVE <br />AUTOMATIC ZONE CONTROL VALVE; HUNTER ICV-FS-AS ELECTRIC REMOTE <br />SIZE AS NOTED <br />CONTROL VALVE W/ ACCU-SYNC PRESSURE REG. MODULE INSTALLED IN METER SIZE <br />VALVE BOX WITH LID; BROOKS, AMETEK OR APP'D EQUAL; <br />INSTALL VALVES WITH APPROVED WATER PROOF WIRE CONNECTORS AND CONTROL <br />WIRE MINIMUM SIZE #14 AWG, TYPE 'UFFROM VALVE TO CONTROLLER IN MAIN <br />LINE IRRIGATION TRENCH; COMMON WIRE TO BE WHITE; <br />IRRIGATION CONTROLLER INSTALLED AT WALL MOUNT LOCATION SELECTED BY OWN <br />R; <br />HUNTER I-CC2 MODEL 12C-800-PL PLASTIC OUTDOOR MODULAR CONTROLLER (12 ) <br />STATION WALL MOUNTED WITH 120 VOLT LINE VOLTAGE POWER CONNECTION <br />LJ <br />FROM PROTECTED HOUSE CIRCUIT; INSTALL ALL WIRING TO CONTROLLER IN <br />CONDUIT; INSTALL WITH HUNTER MINI-CLIK RAIN SENSOR AND BY-PASS <br />SWITCH IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS; PLASTIC CABINET; <br />CONFIRM FINAL LOCATION WITH OWNER PRIOR TO CONSTRUCTION; <br />INSTALL CONTROLLER WITH 245 x 10' LENGTH COPPER GROUNDING RODS & <br />CLAMPS WITH SOLID #8 GROUND WIRE IN ACCORDANCE WITH N.E.C. <br />ALL ELECTRICAL WORK SHALL COMPLY WITH THE N.E.C. <br />IRRIGATION LATERAL PIPE WITH SOLVENT WELD FITTINGS & JOINTS; PVC CLASS <br />SIZE AS NOTED; INSTALL WITH <br />200 SDR 21; ONLY LATERALS WITH PIPE SIZES OF 3/4" <br />AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1/2" SIZE <br />MIN. OF 12" OF EARTH COVER <br />INSIDE PROPERTY LINES <br />11/4" IRRIGATION MAINLINE; SCHEDULE 40 PVC PIPE <br />SIZE AS NOTED; INSTALL WITH <br />- - - - - <br />WITH SCHEDULE 40 SOLVENT WELDED FITTINGS; INSTALL WITH CONTROL WIRE <br />MIN. OF 18" OF EARTH OR 24" FOR PAVEMENT COVER <br />PLACED IN COMMON MAIN LINE TRENCH; 1 1/4" SIZE <br />INSIDE PROPERTY LINES <br />1 1/2" WATER SUPPLY & P.O.C.; INSTALLED IN ACCORDANCE WITH LOCAL AND STATE CODES <br />INSTALL WITH 1-1/2" DOUBLE CHECK VALVE BACKFLOW PREVENTER ON GALV. STL. PIPE 24" ABOVE POURED 4" THICK X 24" X 48" CONC. SLAB; <br />PIPE SLEEVE MINIMUM 24" UNDER PAVING; SCHEDULE 40 PVC FOR IRRIGATION PIPE AND <br />2 PIPE DIAMETERS LARGER <br />IRRIGATION PIPE AND ALLOW FOR IRRIGATION PIPING AND COUPLINGS TO EASILY <br />SLIDE THROUGH SLEEVING MATERIAL; EXTEND SLEEVES 18 INCHES BEYOND <br />EDGES OF PAVING OR OTHER IMPERVIOUS CONSTRUCTION; SEE DETAIL 4/111-2 <br />HB <br />3/4" BRASS HOSE BIB IN PLASTIC METER SIZE BOX WITH LID FOR MANUAL WATERING OF BAHIA GRASS AREAS <br />PLASTIC METER SIZE JUNCTION BOX WITH LID <br />JB <br />FOR WIRE JUNCTION AND MAKE-UP WIRE SPLICE AND DIRECTION CHANGE <br />METER SIZE <br />TYPE OF #14 CONTROL WIRE IN GREY PVC CONDUIT TO ALL VALVES AND CONTROLLER <br />LOW VOLTAGE VALVE CONTROL WIRE; PIPE SLEEVE SIZE SHALL BE 2 TIMES THE <br />VALVE NUMBER <br />CTR# 1 GPM <br />VALVE SIZE <br />GALLONS PER MINUTE <br />../--- <br />NEW TREE PLANTINGS EXISTING TREE <br />WITH (2) BUBBLERS PER BARRICADE <br />EACH TREE, (TYPICAL); <br />SEE LANDSCAPE PLANS <br />LANDSCAPE HEDGE <br />PLANTINGS INSIDE <br />MULCHED PLANT BEDS <br />BORDERED BY BAHIA <br />LAWN GRASS (TYP.); <br />PROVIDE SIDE STRIP 12" <br />POP-UP SPRAY HEAD <br />SPRINKLERS WITH <br />MAXIMUM OF 55% <br />OVERLAP SPRAY; SEE <br />LANDSCAPE PLANS <br />2 <br />SHALL FAMILIARIZE THEMSELVES WITH THE <br />i 1 <br />MINIMUM OF TWO FULL DAYS BEFORE <br />Always call 811 two full business days before you dig to <br />have underground utilities located and marked. <br />REVISIONS NO. DATE <br />NOTE REVISIONS <br />2 <br />10-25-2019 <br />OWNER: <br />NESTLE WATERS <br />NORTH AMERICA <br />N <br />KA <br />JATTS OR Ell <br />sonshineu#01com <br />DETAIL REFERANCE <br />SYMBOL <br />QUAN. <br />DESCRIPTION <br />NATIVE <br />DROUGHT <br />% OF TREE TOTAL <br />NOTES <br />ON SHEET L103 <br />(46 TREES) <br />1 <br />A/1_103 <br />LS <br />9 <br />SWEET GUM; 'LIQUIDAMBAR STYRACIFLUA <br />YES <br />19%o <br />REQUIRED BUFFER <br />30-45 GAL. CONT. >; 12-14' ; 3" CALIPER <br />TREES <br />Lu <br />' ' <br />5 <br />SOUTHERN MAGNOLIA; 'MAGNOLIA GRANDIFLORA' <br />REQUIRED <br />A/L103 <br />MG <br />30-45 GAL. >; 9'-10'; 5'-7' SPREAD; 3" CALIPER <br />YES <br />YES <br />11% <br />REPLACEMENT TREES <br />°o <br />Q <br />SLASH PINE; 'PINUS ELLIOTTP <br />REQUIRED <br />A/L103 <br />PE <br />030-45 <br />5 <br />YES <br />YES <br />11% <br />REPLACEMENT TREES <br />GAL. >; 9' 10' X 5' T SPREAD @ 3" CALIPER <br />CID <br />BALD CYPRESS;'TAXODIUM DISTICHUM' <br />REQUIRED <br />Lu <br />W <br />A/L103 <br />TD o <br />16 <br />30-45 GAL. >; 10-12' HT. X 5'-6' SPREAD @ 3" CALIPER <br />YES <br />YES <br />35% <br />REPLACEMENT TREES <br />~ <br />SA PALM ; A -rf I WN <br />MAXIMUM OF 30% OF <br />B/L103 <br />SP <br />33 <br />WITH BOOTS REMOVED; 12'-16' CL W OD; CED <br />SHADE TREES REQ. <br />(11) <br />AS SHOWN IN PLAN (EQUIVALENC = 11 TREES) <br />YES <br />YES <br />° <br />24/0 <br />3 PER 1 SHADE TREE <br />TOTALS <br />37 <br />TOTAL REQUIRED REPLACEMENT T <br />(BUFFER REQUIRED TREES ARE INCLUDED) <br />80 <br />VIBURNUM OBOVATUM; WALTER VIBURNUM <br />❑ ❑ ❑ ❑ ❑ <br />2 GAL. 18" X 18" INSTALLED T O.C. PLACED <br />❑ ❑ ❑ ❑ ❑ ❑ <br />VO <br />IN STAGGERED ROWS <br />YES <br />YES <br />D, E /L103 <br />m <br />RAPHIOLEPSIS INDICA; INDIAN HAWTHORNE <br />21L1 <br />RI <br />109 <br />2 GAL. 18" X 18" INSTALLED 2.5' O.C. TRIANGULAR <br />YES <br />YES <br />_ <br />E <br />SPACING FOR SIGHT VISIBILITY <br />PHOTINIA GLABRA; RED TIP; 2 GAL. 18" X 18" INSTALLED <br />PG <br />113 <br />2.5' O.C. TRIANGULAR <br />D, E /L103 <br />SPACING PLACED IN STAGGERED ROWS <br />�>%>i <br />FIR <br />435 <br />TRIPSACUM DACTYLOIDES; 1 GAL. <br />12" X 18"; 1.5' O.C. <br />YES <br />YES <br />E /L103 <br />0 <br />W O <br />ARGENTINE BAHIA SOD GRASS; QUANTITY GIVEN IS ESTIMATED. VERIFY QUANTITY PRIOR TO BID; CLEAN GROUND AREA & <br />O U <br />13,311 <br />S.F. <br />FINISH GRADE PER CIVIL DRAWING GRADES AND HAND FINE GRADE & WET SURFACE JUST PRIOR TO LAYING OF SOD; <br />HOLD BACK SOD 3FEET FROM EXISTING TREES; REFER TO SPECIFICATIONS 0N SHEET L103. <br />TYPE 2 <br />FURNISH & INSTALL TREE PROTECTION BARRICADE IN CONFORMANCE WITH CITY OF ZEPHYRHILLS REQUIREMENTS <br />G/L103 <br />on <br />xREMOVE <br />EXISTING TREE WITH ALL ROOTS; PROVIDE REPLACEMENTS IF SPECIFIED AND NOTED <br />FURNISH & INSTALL 3 INCH LAYER OF ORGANIC MULCH OVER FINE HAND RAKED AND CLEANED GROUND SURFACE WITHIN <br />W <br />NOTE <br />#2 <br />PLANT BED LIMITS SHOWN, TYPICAL <br />O <br />Z <br />U <br />LL <br />Lu <br />REMOVE ALL VEGETATION (EXISTING TREES, SHRUBS AND GROUND COVERS) TOGETHER WITH ALL ROOTS EXTENDING 10 <br />V <br />NOTE <br />#3 <br />FEET FROM NEW PAVEMENT EDGE TO PROVIDE CLEARANCE FOR NEW TRUCK PARKING; PROVIDE A 10' CLEAR ZONE FOR <br />TREE BRANCHES FROM PAVEMENT EDGE EXTENDING VERTICALLY TO A MINIMUM HEIGHT OF 16 FEET. FINISH GRADE <br />GROUND AREA AND INSTALL A 10 FOOT WIDTH OF ARGENTINE BAHIA SOD GRASS FROM PAVEMENT EDGE; <br />NOTE #4 <br />PRUNE EXISTING OAK TO ENSURE NO CONFLICT WITH TRUCK OR VEHICLE MOVEMENT.; <br />NOTE #5 <br />SEE CIVIL PLANS FOR POND EXPANSION WORK <br />NOTE #6 <br />LOCATE NEW TREES AND LANDSCAPING AND IRRIGATION WITHIN PROPERTY <br />BOUNDARIES ONLY; THIS AREA SHOWN IS SCHEMATIC ONLY <br />® <br />EXISTING TREE LOCATED BY LICENSED LANDSCAPE ARCHITECT BY SIGHT APPROXIMATION (NOT GUARANTEED ACCURATE) <br />., <br />EXISTING TREE LOCATED BY LICENSED SURVEYOR; SEE CIVIL PLANS <br />CAUTION: PLANT AND TREE HEIGHT AND WIDTH REQUIRED SHALL HAVE PRECEDENCE OVER THE GIVEN CONTAINER SIZE; <br />CONTRACTOR SHALL FURNISH A LARGER CONTAINER SIZE IF REQ'D. TO MEET SPECIFICATIONS <br />GENERAL IRRIGATION SYSTEM NOTES <br />1. IRRIGATION IS DESIGNED TO STANDARDS AND <br />SPECIFICATIONS FOR TURF AND LANDSCAPE <br />IRRIGATION SYSTEMS, FOURTH EDITION, 2000, FLORIDA <br />IRRIGATION SOCIETY AND AS SUBSEQUENTLY AMENDED, <br />OR OTHER APPLICABLE STANDARDS THAT ACHIEVE THE <br />GENERAL IRRIGATION SYSTEM CONFIGURATION <br />REQUIREMENTS AND ASSOCIATED WATER <br />CONSERVATION BENEFITS IDENTIFIED IN THE CITY OF <br />ZEPHYRHILLS LAND DEVELOPMENT CODE. <br />2. TURF AREAS SHALL BE ON SEPARATE IRRIGATION ZONES <br />FROM OTHER LANDSCAPE PLANT ZONES. THE <br />IRRIGATION IS DESIGNED TO ACCOMMODATE SEPARATE <br />LANDSCAPE PLANT ZONES BASED ON DIFFERING <br />WATERING REQUIREMENTS. <br />3. SPRINKLER SPACING SHALL NOT EXCEED 55 PERCENT OF <br />THE SPRINKLER'S DIAMETER OF COVERAGE. <br />4. SPRAYS AND ROTORS SHALL NOT BE COMBINED ON THE <br />SAME CONTROL VALVE CIRCUIT. SPRAYS AND ROTORS <br />SHALL HAVE MATCHING APPLICATION RATES WITHIN <br />EACH IRRIGATION ZONE. <br />5. ALL IRRIGATION SYSTEMS SHALL BE DESIGNED TO AVOID <br />OVERSPRAY, RUNOFF, LOW HEAD DRAINAGE OR OTHER <br />SIMILAR CONDITIONS WHERE WATER FLOWS ONTO OR <br />OVER ADJACENT PROPERTY, NON -IRRIGATED AREAS, <br />WALKWAYS, ROADWAYS, STRUCTURES OR WATER <br />FEATURES. NARROW AREAS (FOUR FEET WIDE OR LESS) <br />SHALL NOT BE IRRIGATED UNLESS MICRO -IRRIGATION IS <br />UTILIZED. <br />6. IRRIGATION CONTROL EQUIPMENT SHALL INCLUDE AN <br />AUTOMATIC IRRIGATION CONTROLLER HAVING <br />PROGRAM FLEXIBILITY SUCH AS REPEAT CYCLES AND <br />MULTIPLE PROGRAM CAPABILITIES. AUTOMATIC <br />IRRIGATION CONTROLLER(S), OTHER THAN <br />MECHANICAL, SHALL HAVE BATTERY BACK-UP TO <br />RETAIN THE IRRIGATION PROGRAM(S). <br />AUTOMATIC CONTROL SYSTEMS SHALL BE EQUIPPED <br />WITH AN OPERABLE RAIN SENSOR DEVICE. ALL <br />ELECTRICAL WORK SHALL BE PERFORMED BY A <br />QUALIFIED LICENSED ELECTRICIAN. <br />7. A LOW VOLUME IRRIGATION SYSTEM SHALL BE USED <br />WHEREVER POSSIBLE TO MINIMIZE EVAPORATION <br />8. IRRIGATION SYSTEM SHALL UTILIZE THE LOWEST <br />QUALITY WATER AVAILABLE. <br />9. IRRIGATION SYSTEM SHALL BE DESIGNED TO MINIMIZE <br />ADVERSE IMPACTS TO EXISTING TREES AND OTHER <br />VEGETATION TO BE PRESERVED ON THE SITE. NO <br />IRRIGATION SHALL BE REQUIRED WITHIN AREAS <br />WHERE EXISTING VEGETATION IS PRESERVED. <br />10. MAINTAIN TREE BARRICADES THROUGHOUT THE <br />INSTALLATION OF THE IRRIGATION PIPING SYSTEM; <br />HAND TRENCH ONLY WITHIN THE DRIP LINE OF <br />EXISTING TREES TO BE PRESERVED. <br />PROJECT: <br />TRAILER <br />PARKING <br />ADDITION- <br />NWNA <br />BOTTLING <br />PLANT <br />4330 20TH ST. <br />ZEPHYRHILLS, FLORIDA 33542 <br />r �� <br />Robert Finnegan PLA <br />Planning + Urban Design + Landscape <br />Architecture <br />Robert Finnegan RLA <br />Florida Landscape Architect <br />Registration No. LA0000428 <br />Cell: 813-766-7756 <br />USA: <br />8950 Park Blvd., #604 <br />Seminole, Florida 33777 <br />Email: robert.finnegan@hotmail.com <br />SEAL: <br />-� <br />�Q �,NDSCgp� <br />F/IyH��P�� <br />o �0 0�py <br />a LPI1 A M/1f1A �f0 a \" <br />L�`L a WWPLV e�i <br />° o <br />STATE o <br />OF <br />ROBERT G FINNEGAN RI <br />TLA. LIC. NO. IA O000428 <br />DRAWING IS NOT VALID WITHOUT I <br />EMBOSSED Ofl ELECTRONIC 5EAL W <br />ORIGINAL OR E-SIGNATURE BY THE <br />LANDSCAPE ARCHITECT OF RECORD <br />CLIENT: <br />alston construction <br />ONE O'HARE CENTER <br />6250 N. RIVER ROAD, SUITE 4050 <br />DIRECT (847) 292-4525 <br />M (312) 909-5904 <br />FX (847) 292-4501 <br />PROJECT MANAGER: <br />R. FINNEGAN <br />JURISDICTION: <br />CITY OF ZEPHYRHILLS <br />PASCO COUNTY, FLA. <br />DATE: <br />08-29-2019 <br />LANDSCAPE & <br />IRRIGATION <br />SCHEDULES <br />SCALE: <br />1" = 30' <br />JOB NO.: <br />082919 <br />SHEET NO.: <br />i inA <br />IISSUED FOR: ❑ PRELIMINARY PERMITTING [FINAL ❑ CONSTRUCTION RECORD DATE: 10-24-2019 <br />10-30-2019 <br />rq <br />r,, <br />