1 <br />2 <br />3 <br />0 <br />5 <br />�-1 <br />7 <br />' <br />GENERAL <br />MATERIALS <br />1. <br />THE STANDARD SPECIFICATIONS LISTED ON THESE CONSTRUCTION PLANS AND SUBSEQUENT DETAILS ARE ALL TO BE CONSIDERED AS PART ON THE <br />1. <br />MATERIALS REQUIRED AND FABRICATION DETAILS SHALL BE AS SPECIFIED ON THE DRAWINGS AND AS WITHIN THIS DOCUMENT. THE CONTRACTOR <br />CONTRACT DOCUMENTS. INCIDENTAL ITEMS OR ACCESSORIES NECESSARY TO COMPLETE THIS WORK MAY NOT BE SPECIFICALLY NOTED BUT ARE TO <br />SHALL CONFORM TO MANUFACTURE DETAILS AND INSTALLATION METHODS. <br />BE CONSIDERED A PART OF THE CONTRACT. <br />2. <br />COMPACTED BACKFILL: <br />2. <br />NO CONSTRUCTION PLANS SHALL BE USED FOR CONSTRUCTION UNLESS SPECIFICALLY MARKED "CONSTRUCTION". PRIOR TO COMMENCEMENT OF <br />A. COMPACTED BACKFILL SHALL CONSIST OF CLEAN GRANULAR FILL MATERIAL, FREE OF DEBRIS, FOREIGN MATERIALS, ORGANIC MATERIAL AND <br />A <br />CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AFFECTING THEIR WORK WITH THE ACTUAL CONDITIONS AT THE <br />SATISFY SP OR SP-SM ACCORDING TO THE UNITED STATES SOIL CLASSIFICATION SYSTEM. <br />JOB SITE. IF THERE ARE ANY DISCREPANCIES FROM WHAT IS SHOWN ON THE CONSTRUCTION PLANS, HE OR SHE MUST IMMEDIATELY REPORT SAME <br />B. BACKFILL TO BE PLACED IN 12-INCH (MAX) LIFTS AND COMPACTED USING MECHANICAL METHODS (E.G. ROLLER). TO ACHIEVE 95 PERCENT <br />TO THE ENGINEER BEFORE DOING ANY WORK, OTHERWISE THE CONTRACTOR ASSUMES FULL RESPONSIBILITY. IN THE EVENT OF DISAGREEMENT <br />MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTMD1557). <br />BETWEEN THE CONSTRUCTION PLANS, STANDARD SPECIFICATIONS AND/OR SPECIAL DETAILS, THE CONTRACTOR SHALL SECURE WRITTEN <br />C. SOIL BELOW PAVEMENT SHALL BE COMPACTED SO THAT THE SOIL DENSITY 12 INCHES BELOW PAVEMEMT SECTION IS AT LEAST 98% OF <br />INSTRUCTIONS FROM THE ENGINEER PRIOR TO PROCEEDING WITH ANY PART OF THE WORK AFFECTED BY OMISSIONS OR DISCREPANCIES. FAILING TO <br />MODFIED PROCTOR MAXIMUM DRY DENSITY (ASTMD1557). <br />SECURE SUCH INSTRUCTION, THE CONTRACTOR WILL BE CONSIDERED TO HAVE PROCEEDED AT HIS OWN RISK AND EXPENSE. IN THE EVENT OF ANY <br />DOUBT OR QUESTION ARISING WITH RESPECT TO THE TRUE MEANING OF THE CONSTRUCTION PLANS OR SPECIFICATIONS, THE DECISION OF THE <br />3. <br />CONCRETE: <br />ENGINEER SHALL BE FINAL AND CONCLUSIVE. <br />A. CONCRETE SHALL BE 8 INCHES THICK AND POURED WITHOUT CONSTRUCTION JOINTS. <br />B. CONCRETE SHALL HAVE A 4,000 PSI STRENGTH AT 28 DAYS AND SHALL CONTAIN STRUCTURAL SYNTHETIC FIBERS (EUCLID TUF-STRAND SF), OR <br />3. <br />ALL WORK PERFORMED UNDER THIS CONTRACT SHALL BE GUARANTEED AGAINST ALL DEFECTS IN MATERIALS AND WORKMANSHIP OR WHATEVER <br />SIMILAR. <br />NATURE BY THE CONTRACTOR AND HIS SURETY FOR A PERIOD OF 12 MONTHS FROM THE DATE OF FINAL ACCEPTANCE OF THE WORK BY THE <br />C. USE 6X6 W2.9 X W2.9 WELDED WIRE FABRIC (WWF) IN DOLLY PADS. <br />ENGINEER. <br />D. A CLEAR COVER OF 3 INCHES IN ALL DIRECTIONS IS REQUIRED FOR ALL WWF PLACEMENT. <br />E. FINAL FINISH SHALL BE BROOM FINISH, <br />4. <br />BEFORE ACCEPTANCE BY THE OWNER AND FINAL PAYMENT, ALL WORK SHALL BE INSPECTED AND APPROVED BY THE OWNER OR HIS <br />F. ALL CONTROL JOINTS SHALL BE PRIMED WITH THIOKOL 415 PRIMER AT 3 - 5 MILS AND SEALED WITH THOKOL 2235M SEALANT. BACKER ROD TO BE <br />REPRESENTATIVE. FINAL PAYMENT WILL BE MADE AFTER ALL OF THE CONTRACTORS' WORK HAS BEEN APPROVED AND ACCEPTED, AND IN <br />PLACED IN EACH JOINT PRIOR TO SEALANT APPLICATION. <br />ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br />5. <br />DURING CONSTRUCTION OPERATIONS THE CONTRACTOR SHALL INSURE POSITIVE DRAINAGE AT THE CONCLUSION OF EACH DAY. <br />SOIL EROSION AND SEDIMENT CONTROL (SESC) <br />6. <br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE FROM THE SITE ANY AND ALL MATERIALS AND DEBRIS WHICH RESULT FROM <br />CONSTRUCTION AND DEMOLITION OPERATIONS. <br />1. <br />SOIL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IN ACCORDANCE WITH NPDES GENERAL PERMIT. ANY SOIL EROSION CONTROL OR <br />B <br />SEDIMENT CONTROL MEASURES, IN ADDITION TO THOSE OUTLINED IN THESE PLANS AND WHICH ARE DEEMED NECESSARY BY THE OWNER, ENGINEER <br />7. <br />THE CONTRACTOR SHALL COMPLY WITH AND OBSERVE THE RULES AND REGULATIONS OF O.S.H.A. AND APPROPRIATE AUTHORITIES REGARDING <br />AND/OR REGULATORY ENGINEER, SHALL BE IMPLEMENTED IMMEDIATELY BY THE CONTRACTOR. <br />SAFETY PROVISIONS. <br />2. <br />ALL DRAINAGE STRUCTURES, PIPES, SWALES, AND OTHER AREAS ACCUMULATING SEDIMENT ARE TO BE CLEANED AT THE END OF THE PROJECT <br />8. <br />THE ENGINEER AND OWNER ARE NOT RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, TIME <br />PRIOR TO FINAL ACCEPTANCE. CLEANING MAY ALSO BE REQUIRED DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT IF IT IS <br />OF PERFORMANCE, PROGRAMS OR FOR ANY SAFETY PRECAUTIONS USED BY THE CONTRACTOR. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR <br />DETERMINED THAT THE SILT AND DEBRIS TRAPS ARE NOT FUNCTIONING PROPERLY OR EXCESS DEBRIS HAS COLLECTED. <br />EXECUTION OF HIS WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND SPECIFICATIONS. <br />3. <br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE FROM THE SITE ANY AND ALL MATERIALS AND DEBRIS WHICH RESULT FROM <br />9. <br />ALL CONTRACTORS AND THEIR SUBCONTRACTORS OR ANY TIER SHALL INDEMNIFY THE OWNER AND ENGINEER FROM ALL LIABILITY RESULTING FROM <br />CONSTRUCTION/DEMOLITION OPERATIONS. <br />ANY NEGLIGENT ACT OR OMISSION WITH THEIR CONSTRUCTION, INSTALLATION, AND TESTING OR WORK ON THIS PROJECT AND SHALL NAME THEM AS <br />ADDITIONAL INSURED ON THEIR COMMERCIAL GENERAL LIABILITY POLICIES FOR CLAIMS ARISING OUT OF THE WORK ON THIS PROJECT. A PROPER <br />4. <br />THE DISTURBED AREAS SHALL BE SEEDED OR SODDED UPON COMPLETION OF DISTURBANCE. <br />CERTIFICATE OF INSURANCE SHALL BE ISSUED PRIOR TO THE START OF CONSTRUCTION. <br />5. <br />NO AREA SHALL REMAIN UNSEEDED OR SODDED LONGER THAN 14 DAYS FROM LAST TIME OF DISTURBANCE. <br />10. <br />ELECTRIC, TELEPHONE, NATURAL GAS, AND OTHER UTILITY COMPANIES MAY HAVE UNDERGROUND AND/OR OVERHEAD SERVICE FACILITIES IN THE <br />VICINITY OF THE PROPOSED WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING THE UTILITY COMPANIES LOCATE THEIR FACILITIES IN <br />6. <br />THE CONTRACTOR SHALL PERFORM AND DOCUMENT ROUTINE INSPECTIONS OF THE SOIL EROSION AND SEDIMENT CONTROLS AS REQUIRED BY THE <br />THE FIELD PRIOR TO CONSTRUCTION AND SHALL ALSO BE RESPONSIBLE FOR THE MAINTENANCE AND PRESERVATION OF THESE FACILITIES. THE <br />ENVIRONMENTAL RESOURCE PERMIT (ERP). THE INSPECTOR SHALL BE QUALIFIED TO PERFORM THE REQUIRED INSPECTIONS. INSPECTION RECORDS <br />CONTRACTOR SHALL CALL 811 FOR UTILITY LOCATIONS. <br />SHALL BE MAINTAINED ON SITE AND PROVIDED TO THE OWNER AT THE END OF THE JOB, OR UPON REQUEST. <br />11. <br />THE CONTRACTOR SHALL HAVE A COMPETENT SUPERINTENDENT ON THE PROJECT SITE AT ALL TIMES IRRESPECTIVE OF THE AMOUNT OF WORK <br />SUBLET. THE SUPERINTENDENT SHALL BE CAPABLE OF READING AND UNDERSTANDING THE PLANS AND SPECIFICATION, SHALL HAVE FULL AUTHORITY <br />SITE RESTORATION AND PLANTING <br />C <br />TO EXECUTE ORDERS TO EXPEDITE THE PROJECT, AND SHALL BE RESPONSIBLE FOR SCHEDULING AND HAVE CONTROL OF ALL WORK AS THE AGENT <br />OF THE CONTRACTOR. FAILURE TO COMPLY WITH THIS PROVISION WILL RESULT IN A SUSPENSION OF WORK. <br />1. <br />THE DISTURBED AREA SHALL HAVE 6-INCH OF TOPSOIL (WEED FREE) SPREAD PRIOR TO SEEDING. AFTER THE AREAS TO BE SEEDED HAVE BEEN <br />BROUGHT TO THE GRADES INDICATED ON THE ACCOMPANYING PLANS, ANY GROSS IRREGULARITIES IN THE SURFACE RESULTING FROM THEIR <br />12. <br />THE CONTRACTOR SHALL KEEP A SET OF "APPROVED" CONSTRUCTION PLANS ON THE JOB SITE, AND SHALL MAINTAIN (AS INDICATED HEREIN AND <br />OPERATIONS SHALL BE SMOOTHED OUT BEFORE SEEDING OPERATIONS ARE BEGUN. ALL UNSUITABLE MATERIAL LARGER THAN ONE 1-INCH IN ANY <br />ELSEWHERE WITHIN THESE CONSTRUCTION NOTES, SPECIFICATION, AND PLANS) A LEGIBLE RECORD ON SAID PLANS OF ANY <br />DIMENSION SHALL BE REMOVED AND DISPOSED OF DURING THIS OPERATION. <br />MODIFICATIONS/ALTERATIONS TO ALIGNMENT AND/OR TO PLANS AND SPECIFICATIONS OF PROPOSED IMPROVEMENTS, ETC. UPON COMPLETION OF <br />THE CONTRACTORS' WORK, SAID PLANS AND INFORMATION SHALL BE PROVIDED TO THE ENGINEER. FINAL CONTRACT PAYMENT SHALL NOT COME DUE <br />2. <br />SEED SHALL BE INSTALLED INTO RECENTLY GRADED SOIL BY USE OF A NO -TILL DRILL SEEDER DESIGNED SPECIFICALLY TO HANDLE NATIVE SEEDS. AN <br />UNTIL THIS INFORMATION IS RECEIVED BY THE ENGINEER. <br />APPROPRIATE COVER CROP SHOULD BE INSTALLED WITH ALL SEED MIXES. SEEDING SHOULD OCCUR IN THE LATE FALL OR SPRING AND EARLY <br />SUMMER. IF A FALL PLANTING IS PERFORMED ATTENTION SHOULD BE PAID TOWARDS PROTECTING THE SEED FROM EROSION DURING THE WINTER <br />13. <br />THESE PLANS ARE NOT SUITABLE FOR MACHINE GUIDANCE USE OR PURPOSES. THE ELEVATIONS AND CONTOURS ON THE PLANS ARE ASSUMED TO BE <br />MONTHS. THE DRILL SEEDER OPERATOR SHOULD PLANT PERPENDICULAR TO THE DIRECTION OF THE SLOPE TO ENSURE SEED STABILITY. IF LATE FALL <br />NGVD 1929, U.S. SURVEY FEET. <br />PLANTING IS NOT PRACTICABLE, THEN THE FOLLOWING SHALL APPLY. SEED SHALL BE DRILLED WITH OVERLAPPING PLANTING ZONES IN DRY AREAS <br />AND TIMES. <br />14. <br />CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER AND SEQUENCE THAT EROSION AND AIR AND WATER POLLUTION ARE <br />MINIMIZED AND HELD WITHIN LEGAL LIMITATIONS. <br />3. <br />TO MINIMIZE EROSION AFTER SEEDING, EROSION BLANKET SHALL BE INSTALLED IN SWALES, ON BASIN SIDE SLOPES, AND ANY SLOPES STEEPER THAN <br />10 PERCENT TO MAINTAIN SOIL MOISTURE AND MINIMIZE EROSION AS SPECIFIED IN THE SOIL EROSION AND SEDIMENT CONTROL SECTION. <br />15. <br />THE COMPLETED JOB SHALL CONFORM TO THE LAYOUT, ELEVATIONS, AND SPECIFICATIONS CONTAINED WITHIN THE PLAN SET. <br />EARTHWORK <br />D <br />1. <br />PRIOR TO ONSET OF GRADING OPERATIONS, THE CONTRACTOR SHALL FAMILIARIZE THE CREW WITH THE SOIL EROSION CONTROL SPECIFICATIONS. <br />THE INITIAL ESTABLISHMENT OF EROSION CONTROL PROCEDURES AND THE PLACEMENT OF SILT FENCING, ETC. TO PROTECT ADJACENT PROPERTY <br />AND ROAD RIGHT OF WAY SHALL OCCUR BEFORE GRADING BEGINS, AND IN ACCORDANCE WITH THE SOIL EROSION CONTROL CONSTRUCTION <br />SCHEDULE. <br />2. <br />THE GRADING OPERATIONS ARE TO BE CLOSELY SUPERVISED AND INSPECTED, PARTICULARLY DURING THE REMOVAL OF UNSUITABLE MATERIAL AND <br />EXISTING INFRASTRUCTURE, BY THE CONTRACTOR. <br />3. <br />THE PROPOSED GRADING ELEVATIONS SHOWN ON THE PLANS ARE FINISHED GRADE. TOPSOIL IS TO BE PLACED BEFORE FINISHED GRADE <br />ELEVATIONS ARE ACHIEVED. <br />4. <br />THE BACKFILL MATERIAL SHALL BE PLACED IN LEVEL UNIFORM LAYERS. EACH LAYER SHALL BE THOROUGHLY MIXED DURING SPREADING TO INSURE <br />UNIFORMITY. <br />5. <br />THE WORK AREA SHALL BE CLEARED OF SOD AND RUBBISH. <br />6. <br />THE PLACING AND SPREADING OF THE FILL MATERIAL SHALL BE STARTED AT THE LOWEST POINT AND THE FILL SHALL BE BROUGHT UP IN <br />N <br />O <br />APPROXIMATELY HORIZONTAL LAYERS NOT EXCEEDING 3-INCH LIFTS FOR HAND COMPACTION, 6-INCH LIFTS FOR RUBBER TIRED AND MANUALLY <br />IL <br />DIRECTED POWER TAMPERS, AND 12-INCH FOR VIBRATORY DRUM ROLLER. EACH LAYER SHALL BE SPREAD, PROCESSED, AND COMPACTED. THE <br />M <br />w <br />MOISTURE CONTENT OF THE FILL MATERIAL AND FOUNDATIONS SHALL BE SUCH THAT THE REQUIRED COMPACTION CAN BE OBTAINED. TOPSOIL SHALL <br />BE PLACED IN A LOOSE LIFT AND NOT COMPACTED. <br />Z <br />❑ <br />s <br />o <br />REV DATE DESCRIPTION DRN APP <br />w <br />z <br />0 <br />a <br />GeosyntecO'Wtin <br />consultants C O N S T R U C T I O N <br />12802 TAMPA OAKS BLVD., SUITE 151 ALSTON CONSTRUCTION <br />TAMPA, FL 33637 USA ONE O'HARE CENTER <br />LU <br />TELEPHONE: 813 558 0990 6250 N. RIVER ROAD, SUITE 4050 <br />AUTHORIZATION NUMBER 4321 ROSEMONT, IL 60018 USA <br />Cl) <br />i <br />TITLE: <br />2 <br />GENERAL NOTES <br />Y <br />U <br />7 <br />z <br />PROJECT: NESTLE ZEPHYRHILLS PLANT <br />g <br />4330 20th STREET, ZEPHYRHILLS, PASCO COUNTY FLORIDA <br />J <br />r <br />SITE: <br />w <br />TRUCK PARKING MODIFICATIONS <br />N <br />F <br />w <br />J <br />THIS DRAWING MAY NOT BE ISSUED <br />w <br />FOR PROJECT TENDER OR DESIGN BY: MHS DATE: OCTOBER 2019 <br />w <br />CONSTRUCTION, UNLESS SEALED. <br />J <br />w <br />DRAWN BY: MRM PROJECT NO.: FL3619 <br />z <br />z <br />U <br />SIGNATURE CHECKED BY: MHS FILE: FL3619PO2 <br />w <br />O <br />a <br />REVIEWED BY: TDA DRAWING NO.: <br />PERMIT DRAWING - NOT FOR CONSTRUCTION <br />DATE <br />APPROVED BY: MHS 2 <br />MICHAEL H. SCOTT, PE -LICENSE N0. 72475 OF <br />1 2 3 <br />4 5 6 <br />7 8 <br />Fj <br />C <br />9 <br />E <br />r <br />T I- -._-I Ii I- I -I 111 -- <br />