My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4330 20th St (45)
Zephyrhills
>
Building Department
>
Building Plans
>
4330 20th St (45)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 8:16:00 PM
Creation date
2/18/2025 3:28:32 PM
Metadata
Fields
Template:
Building Plans
Street #
4330
Location
20th St
Contractor
Keener Construction
Building Plans - Permit #
8264 & 8265
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS: <br />DATE: 9-25-08 <br />PER BLDG DEPT <br />DATE: <br />ABBREVIATIONS <br />A <br />AMPERE <br />AF <br />AMPERE FRAME <br />AFF <br />ABOVE FINISHED FLOOR <br />AFG <br />ABOVE FINISHED GRADE <br />AHU <br />AIR HANDLING UNIT <br />AL <br />ALUMINUM <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />AWG <br />AMERICAN WIRE GAUGE <br />C <br />CONDUIT <br />CAT <br />CATEGORY <br />CB <br />CIRCUIT BREAKER <br />CH <br />CHILLER <br />CKT <br />CIRCUIT <br />CL <br />CENTER LINE <br />CLG <br />CEILING <br />CU <br />COPPER <br />DWG DRAWING <br />EC <br />ELECTRICAL CONTRACTOR <br />EF <br />EXHAUST FAN <br />EM <br />EMERGENCY <br />EMT <br />ELECTRICAL METALLIC TUBING <br />ENCL <br />ENCLOSURE <br />EWH <br />ELECTRIC WATER HEATER <br />EXIST, EX <br />EXISTING <br />FA <br />FIRE ALARM <br />FCP <br />FIRE ALARM CONTROL PANEL <br />FACC <br />FIRE ALARM COMMAND CENTER <br />FATC <br />FIRE ALARM TERMINAL CABINET <br />FO <br />FIBER OPTIC <br />GFI <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GND,G <br />GROUND <br />HOA <br />HAND -OFF -AUTO <br />HACR <br />HEATING/AIR CONDITIONING -RATED <br />HID <br />HIGH INTENSITY DISCHARGE <br />HPF <br />HIGH POWER FACTOR <br />HPS <br />HIGH PRESSURE SODIUM <br />HP <br />HORSEPOWER <br />IG ISOLATED GROUND <br />JB JUNCTION BOX <br />KCMIL THOUSAND CIRCULAR MILS <br />KVA KILOVOLT AMPERE <br />KW KILOWATT <br />MCB <br />MAIN CIRCUIT BREAKER <br />MCC <br />MOTOR CONTROL CENTER <br />MDP <br />MAIN DISTRIBUTION PANEL <br />MH <br />METAL HALIDE <br />MLO <br />MAIN LOAD ONLY <br />MTD <br />MOUNTED <br />NC <br />NORMALLY CLOSED <br />NEC <br />NATIONAL ELECTRICAL CODE <br />NEMA <br />NATIONAL ELECTRICAL MANUFACTURERS ASSOC. <br />NF <br />NON -FUSED <br />NFPA <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NIC <br />NOT IN CONTRACT <br />NIL <br />NIGHT LIGHT <br />NO <br />NORMALLY OPEN <br />PNL <br />PANEL <br />0 <br />PHASE <br />PB <br />PUSHBUTTON <br />PVC <br />POLYVINYL CHLORIDE CONDUIT <br />RGC <br />RIGID GALVANIZED STEEL CONDUIT <br />SW <br />SWITCH <br />SWBD <br />SWITCHBOARD <br />TVSS <br />TRANSIENT VOLTAGE SURGE SUPPRESSOR <br />TS <br />TIME SWITCH <br />XFMR <br />TRANSFORMER <br />TYP <br />TYPICAL <br />UG <br />UNDERGROUND <br />UH <br />UNIT HEATER <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />LON <br />UNLESS OTHERWISE NOTED <br />VAV <br />VARIABLE AIR VOLUME <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />V <br />VO LT <br />Ili9• g1_11a1:ia 101161411 <br />LIGHTING LEGEND <br />1 a CEILING MTD. 2'x4' LIGHT FIXTURE (SEE SCHEDULE) <br />A❑° a CEILING MOUNTED 2'x2' LIGHT FIXTURE (SEE SCHEDULE) <br />A a CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />1 a WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A O a CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A Q ° WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />1 ❑ a CEILING MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A pa WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A f---Q--{ a FLUORESCENT STRIP (SEE SCHEDULE) <br />A-- 60 POLE MOUNTED LUMINAIRE (SEE SCHEDULE) <br />10-o-0 2 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />1 3 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A40 <br />1 4 HEAD POLE MOUNTED LIGHT FIXTURE (SEE SCHEDULE) <br />A <br />EXIT LIGHT <br />EXIT LIGHT AND EMERGENCY LIGHT COMBO <br />A EMERGENCY LIGHTING FIXTURE WITH BATTERY BACK-UP (SEE SCHEDULE) <br />A o 0 o a TRACK LIGHT. NUMBER OF HEADS AS SHOWN (SEE SCHEDULE). <br />LIGHTING CONTROLS <br />M ,a SINGLE SINGLE POLE SWITCH 20A 277V UON CENTERLINE MOUNTED 48" AFF <br />K: KEY TYPE M: MOTOR RATED <br />S2 DOUBLE POLE 20A 240V SWITCH - UON CENTERLINE MOUNTED 48" AFF <br />S3 THREE WAY 20A 277V SWITCH - UON CENTERLINE MOUNTED 48" AFF <br />S4 FOUR WAY WALL MOUNTED SWITCH - UON CENTERLINE MOUNTED 48" AFF <br />Sp DIMMER SWITCH - UON CENTERLINE MOUNTED 48" AFF <br />Ts I TIME SWITCH AS INDICATED. UON MOUNT TOP OF ENCLOSURE 66" AFF <br />o5 CEILING MOUNTED OCCUPANCY SENSOR. SEE SPECIFICATIONS <br />os WALL MOUNTED OCCUPANCY SENSOR. UON CENTERLINE MOUNTED 48" AFF <br />GENERAL NOTES <br />1. TEXT SHOWN ON PLANS ADJACENT TO LIGHTING FIXTURES SHALL DENOTE THE FOLLOWING: <br />LOWERCASE LETTER (BY FIXTURE OR SWITCH) INDICATES LIGHT SWITCH CONTROL. UPPERCASE <br />LETTER INDICATES FIXTURE TYPE. NUMERAL INDICATES BRANCH CIRCUIT NUMBER. <br />2. SHADED LIGHTING FIXTURE SYMBOLS THAT APPEAR ON PLANS INDICATE EMERGENCY LIGHTING <br />FIXTURES AND SHALL BE INTERPRETED AS FOLLOWS: <br />LIFE SAFETY BRANCH CIRCUIT: <br />CRITICAL BRANCH CIRCUIT: <br />EMERGENCY LIGHT FIXTURE <br />WITH BATTERY BACK UP: <br />(THE ABOVE SHALL APPLY TO ALL LIGHTING FIXTURE SYMBOLS SHOWN ON LEGEND). <br />3. NUMERALS SHOWN ON PLANS ADJACENT TO WIRING DEVICES INDICATE BRANCH CIRCUIT NUMBER(S). <br />4. STANDARD SYMBOLS SHOWN ON LEGEND MAY NOT ALL APPEAR ON PLANS. WHERE SYMBOL <br />APPEARS ON PLANS FURNISH AND INSTALL AS SPECIFIED. <br />5. ALL STANDARD SYMBOLS ON LEGEND THAT APPEAR ON PLANS WITH HIDDEN LINES SHALL BE EXISTING <br />TO REMAIN (FOR REFERENCE ONLY). EXISTING SYMBOLS (AS DESCRIBED ABOVE) THAT APPEAR ON <br />PLANS WITH AN ADJACENT ABBREVIATION SHALL BE INTERPRETED AS FOLLOWS: <br />RL = EXISTING TO BE RELOCATED (SHOWN AT EXISTING LOCATION ON DEMOLITION PLAN), <br />REFER TO INSTALLATION PLAN FOR NEW LOCATION. CONTRACTOR SHALL EXTEND WIRING TO NEW <br />LOCATION AND RECONNECT. <br />R = EXISTING TO BE REMOVED. CONTRACTOR SHALL REMOVE DEVICE AND/OR EQUIPMENT AND <br />UNLESS OTHERWISE NOTED REMOVE ALL UNUSED CONDUIT AND WIRING. <br />6, ALL INSTALLATIONS SHALL COMPLY WITH LEED FOR NEW CONSTRUCTION VERSION 2.2 OCT. 2005 AND <br />COMPLY WITH NEC AND APPLICABLE LOCAL CODES. <br />POWER LEGEND <br />HOMERUN TO PANEL INDICATED (CONCEALED). MINIMUM 3/4"C. UNLESS <br />OTHERWISE NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY <br />NUMBER OF CIRCUITS SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL <br />LP- 1 <br />CONDUCTORS. FOR HOMERUNS EXCEEDING 100' IN LENGTH PROVIDE #10 <br />CONDUCTORS IN LIEU OF #12 AS INDICATED ABOVE, THERE SHALL BE A <br />MAXIMUM OF 3 BRANCH CIRCUITS PER HOMERUN (AS INDICATED ON <br />PLANS). TEXT SHOWN BY HOMERUN INDICATES PANELBOARD DESIGNATION <br />AND CIRCUIT NUMBER(S). <br />CONDUIT CONCEALED IN WALL OR ABOVE CEILING SPACE. UNLESS OTHERWISE <br />NOTED PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS <br />SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 1/2"C. <br />UNDERGROUND CONDUIT OR BELOW SLAB. UNLESS OTHERWISE NOTED <br />— - — <br />PROVIDE #12 CONDUCTORS AS REQUIRED BY NUMBER OF CIRCUITS <br />SHOWN. INCLUDE #12 GROUND AND #12 NEUTRAL. MINIMUM 3/4"C. <br />- - - - - - <br />EXISTING CONDUIT. AS INDICATED. <br />P <br />UNDERGROUND POWER DUCT BANK, AS INDICATED. <br />C <br />UNDERGROUND COMMUNICATIONS DUCT BANK. AS INDICATED. <br />OH <br />OVERHEAD LINE. AS INDICATED. <br />MH <br />i <br />MANHOLE. SEE SPECIFICATIONS. <br />HH <br />HAND HOLE. SEE SPECIFICATIONS. <br />i <br />Q <br />CEILING OR WALL MOUNTED JUNCTION BOX. UON SIZE AS REQUIRED <br />BY NEC. <br />FLOOR MOUNTED JUNCTION BOX. UON SIZE AS REQUIRED BY NEC. <br />�. <br />MOTOR. AS INDICATED. <br />Tvss <br />TRANSIENT VOLTAGE SURGE SUPPRESSION AS INDICATED <br />El <br />SINGLE PUSHBUTTON. UON CENTERLINE MOUNTED 48" AFF <br />PP <br />PUSH PLATE. UON CENTERLINE MOUNTED 48" AFF <br />480/277V, PANELBOARD. <br />G <br />208/12OV, PANELBOARD. <br />208/12OV, DISTRIBUTION PANELBOARD. <br />480/277V, DISTRIBUTION PANELBOARD. <br />6 <br />MISCELLANEOUS PANELBOARD, AS INDICATED. <br />T <br />DRY TYPE TRANSFORMER. AS INDICATED. <br />HEAVY DUTY DISCONNECT SWITCH, NON FUSIBLE. SEE SPECIFICATIONS. <br />UON MOUNT TOP OF ENCLOSURE 66" AFF <br />HEAVY DUTY FUSIBLE DISCONNECT SWITCH. FUSED AS INDICATED ON <br />PLANS. SEE SPECIFICATIONS. UON MOUNT TOP OF ENCLOSURE 66" AFF. <br />HEAVY DUTY FUSIBLE COMBINATION STARTER/DISCONNECT SWITCH. <br />SEE SPECIFICATIONS. UON MOUNT TOP OF ENCLOSURE 66" AFF. <br />B <br />MAGNETIC MOTOR STARTER. UON MOUNT TOP OF ENCLOSURE 66" AFF. <br />SEE SPECIFICATIONS. <br />® <br />VARIABLE FREQUENCY DRIVE AS INDICATED. UON MOUNT TOP OF <br />ENCLOSURE 72" AFF <br />ENCLOSED CIRCUIT BREAKER. AS INDICATED, <br />SINGLE RECEPTACLE. 20A 120V LION CENTERLINE MOUNTED 18" AFF <br />DUPLEX RECEPTACLE. 20A 120V UON CENTERLINE MOUNTED 18" AFF <br />DUPLEX RECEPTACLE. 20A 120V UON CENTERLINE MOUNTED 42" AFF <br />50A 10 240V RECEPTACLE. UON CENTERLINE MOUNTED 18" AFF <br />DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V UON CENTERLINE <br />MOUNTED 18" AFF. <br />DOUBLE DUPLEX RECEPTACLE OUTLET. 20A 120V ION CENTERLINE <br />MOUNTED 42" AFF. <br />® <br />SPECIAL RECEPTACLE, AS INDICATED. UON CENTERLINE MOUNTED 18" AFF. <br />® <br />FLOOR MOUNTED DUPLEX RECEPTACLE. <br />FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE. <br />0 <br />FLOOR MOUNTED COMBINATION (20A 120V) DUPLEX RECEPTACLE/DATA <br />COMMUNICATION OUTLET. <br />O 0 <br />FLOOR MOUTNED COMBINATION (20A 120V) DOUBLE DUPLEX <br />RECEPTACLE/DATA COMMUNICATION OUTLET. <br />MULTI OUTLET STRIP OR POWER/DATA COMMUNICATION <br />RACEWAY AS INDICATED. <br />B B <br />BUSWAY. SEE SPECIFICATIONS. <br />DUCT HEATER. (FURNISHED UNDER DIV. 15). (WIRED UNDER DIVISION 16). <br />i <br />I <br />RISER SYMBOLS LEGEND ELECTRICAL SPECIFICATIONS <br />1; ALL WORK SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND SHALL ALSO COMPLY <br />WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES. <br />GROUND FAULT SENSOR Lc) <br />2. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE THHN/THWN 75'C. L <br />(167' F.) FOR DRY, DAMP AND WET LOCATIONS. CONDUCTOR INSULATION WITH SINGLE TYPE MARKING L �' <br />THHN 90' C. (194' F.) MAY BE USED FOR DRY LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR # <br />b CODED AS REQUIRED BY NEC 3 <br />ry co <br />Jl CIRCUIT BREAKER. AS INDICATED THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT. <br />co W <br />�LL_ CC <br />v� <br />3; UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN ALUMINUM IN CHEM ROOM AREA AND a 3 a' <br />AND RCS (RIDGID GALV. STEEL) IN MEZZ. AREA. CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED 6 <br />S ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL, HEX -NUT, EXPANSION -GLAND MU c: o <br />L o C <br />/ TYPE, ZINC OR CADMIUM PLATED. a o <br />DRAWOUT CIRCUIT BREAKER. AS INDICATED E <br />I C3 0 W <br />4O <br />; THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED <br />BY NATIONAL ELECTRICAL CODE. ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY <br />SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS AND EQUIPMENT. ALL RACEWAYS <br />L SHALL BE PROPERLY ALIGNED, GROUPED AND SUPPORTED AT INTERVALS NOT EXCEEDING 8 FEET. <br />T STARTER / CONTACTOR EXISTING RACEWAYS TO REMAIN SHALL BE RESUPPORTED WHERE RACEWAY SUPPORTS EXCEED 8 m r- <br />FEET. ^ ono <br />OG GENERATOR 5; COVER PLATES FOR FLUSH OR SURFACE MOUNTED WALL BOXES SHALL DUPLICATE EXISTING DEVICES <br />IN SIMILAR PLANT AREAS. E co co <br />b 6; ALL NEW OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE SCREW Lo <br />o x <br />SWITCH FASTENED COVERS. � 0r ,° 00 <br />0 <br />3 <br />N Z <br />�l p • <br />' <br />OUTLET BOXES SHALL TYPE FS CAST IRON. NEW AND EXISTING OUTLET BOXES INCLUDING k o E Q <br />COVERPLATE OF DUPLEX RECEPTACLES SHALL BE IDENTIFIED WITH BRANCH CIRCUIT NUMBER OFcu w m m <br />CIRCUIT TERMINATED WITHIN. N a v <br />THERMAL OVERLOAD ELEMENT 7, THE CONTRACTOR SHALL REMOVE ALL EXISTING WIRING AND EQUIPMENT MADE UNNECESSARY BY THE Q�j "o O <br />NEW INSTALLATION. ALL MATERIALS REMOVED SHALL BE DISPOSED OF BY THE CONTRACTOR. .Q � „ <br />8, UPON COMPLETION OF WORK CORRECT ALL PANELBOARD CIRCUIT DIRECTORY CARDS TO REFLECT j 00 Q <br />RECORD CONDITIONS. s o <br />a U <br />TRANSFORMER <br />9; WHERE EXISTING RECEPTACLES ARE SHOWN TO BE REMOVED FROM PARTITIONS BEING REMOVED, <br />CONTRACTOR SHALL MAINTAIN SERVICE TO REMAINING OUTLETS. <br />10. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES <br />AND SIMILAR CIRCUITS SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT GROUND Z <br />FUSE CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL <br />TT I <br />SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR n <br />CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON DRAWINGS. GROUND <br />GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN PANELBOARDS. <br />11. LIGHTING FIXTURES: 0 <br />Q RELAY COIL, NOTED WITH TEXT A, THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE IN ALL RESPECTS ALL LIGHTING FIXTURES j U <br />LISTED IN THE FIXTURE SCHEDULE. <br />B. THE CONTRACTOR SHALL SUBMIT CATALOG CUTS OF ALL THE FIXTURES TO THE GENERAL '�' I <br />b CONTRACTOR. W <br />o <br />FUSED SWITCH "' <br />C, BALLASTS FOR FLUORESCENT LAMPS SHALL BE HIGH POWER FACTOR TYPE AND SHALL BEAR THE CBM, w <br />ETL, AND UL LABELS. ALL BALLASTS SHALL BE UNDERWRITERS' CLASS P. BALLASTS SHALL BE w Q <br />0 <br />TRIAD-UTRAD "BALLASTAR". ALL BALLASTS FOR FLUORESCENT FIXTURES SHALL BE INDIVIDUALLY ac <br />FUSED. FUSES SHALL BE INSTALLED ON THE LINE SIDE OF THE BALLAST. Q o <br />J <br />�LL_ <br />D, T-8 AND T-5 BULB FLUORESCENT LAMPS SHALL BE INSTANT START, OCTRON CR175 WITH A o <br />AUTOMATIC TRANSFER SWITCH CORRELATED COLOR TEMPERATURE OF 3100K. ALL COOL WHITE LAMPS SHALL BE AS MANUFACTURED J N C <br />BY SYLVANIA OR G.E. <br />E, ALL FIXTURES SHALL BE PROPERLY AND CAREFULLY SUPPORTED AND ALIGNED, AND THE CONTRACTOR <br />SHALL FURNISH AND INSTALL ALL NECESSARY STEEL SHAPES, ETC., FOR SUPPORT OF FIXTURES AS = <br />REQUIRED AND DETAILED ON THE DRAWINGS. LIGHTING FIXTURES SHALL BE CLEAN AND LAMPED WITH w <br />OM METER SOCKET NEW LAMPS AT THE TIME OF FINAL INSPECTION. 0 N <br />m <br />� r^ <br />VJ <br />TJ <br />2 <br />O <br />J <br />Li ^_ <br />O �.L <br />w W <br />N <br />RICHARD P. CHRUSZCZ, P.E. <br />FLTE LIC. #40080 <br />U <br />Z <br />M <br />r <br />04 <br />N <br />0 <br />U <br />0 <br />U <br />o <br />(oco <br />Q <br />W <br />NM t0 <br />W <br />°° °° <br />O <br />U <br />� M <br />c0 t0 <br />°° ov <br />Plan <br />ZEPHYRHILLS <br />Job # <br />2924 <br />Date <br />8-20-08 <br />Sheet <br />E-100_ <br />
The URL can be used to link to this page
Your browser does not support the video tag.