My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
4330 20th St (47)
Zephyrhills
>
Building Department
>
Building Plans
>
4330 20th St (47)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 9:08:52 PM
Creation date
2/18/2025 3:54:20 PM
Metadata
Fields
Template:
Building Plans
Street #
4330
Location
20th St
Contractor
Whiting Turner Contracting Company
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Gll <br />B I C <br />I I <br />E <br />Fa <br />1 <br />22 <br />I <br />I <br />>_ I I <br />z <br />0z <br />p W I I <br />I- w I <br />2 <br />�a i <br />M_ <br />�W <br />LL <br />cp <br />02 <br />N W <br />zM <br />OY) <br />Fna <br />za <br />W w <br />X w <br />w <br />O = <br />0 <br />zz 3 <br />Ft ¢ <br />00 <br />Lu Lu <br />U <br />OD <br />zd <br />W Lu <br />cnm <br />w'5 <br />0Z <br />U_ w <br />wz <br />J 0 <br />Q U <br />I- W <br />am <br />co w4 <br />� <br />mY <br />00 <br />uJw <br />z� <br />w0 <br />w~ <br />u <br />a J <br />wa <br />0 -� <br />0 <br />w0 <br />0 = <br />z_ <br />z0 <br />—0 5 <br />0< <br />zY <br />cnS2 <br />Ix <br />~w <br />�_j <br />00 <br />w <br />0 <br />�w <br />z <br />0� <br />w0 <br />z <br />a: w <br />wF- <br />0 <br />¢Q <br />Om <br />j�-)= 6 <br />�cl) <br />�cn <br />w <br />w <br />2 <br />0}0 = <br />U <br />0 � <br />Lufn <br />ly- 0 <br />az <br />w¢ <br />wo <br />a-w <br />v� <br />O <br />�_ <br />w F- <br />cnD <br />u-¢ <br />00 <br />W~ Z 7 <br />� <br />5Y <br />cp� <br />Z_Ix <br />Z W <br />cno <br />�--Z <br />¢O <br />�0 <br />z <br />z <br />M� <br />0 ,Z <br />0� <br />z0 <br />w0 8 <br />w ~ <br />Lu U <br />W _ <br />w <br />=0 <br />0 <br />} ui <br />zcn <br />¢M <br />w <br />0w <br />¢ U <br />Z --.� <br />w <br />°- <br />cn q� <br />Lu <br />~p 9 ® A WAREHOUSE EXPANSION DEMOLITION PLAN <br />iml <br />(:20 <br />'1 SCALE: 1/16" = 1'-0" <br />Le <br />0 <br />1 <br />ISSUE FOR CONSTRUCTION <br />07/15/22 <br />JWT <br />JWT <br />JWT <br />TC <br />TC <br />0 <br />ISSUE FOR PERMIT <br />06/24/22 <br />JWT <br />JWT <br />JWT <br />TC <br />TC <br />REV <br />REVISION DESCRIPTION <br />DATE <br />DRWN <br />DSGN <br />CHKD <br />QC <br />APPD <br />REF. DWG. NO <br />Le <br />I <br />REFERENCE DRAWING TITLE <br />------------- ( <br />FF <br />Eel <br />DEMOLITION PLAN KEY NOTES <br />REMOVE EXISTING DOOR, FRAME AND HARDWARE COMPLETE <br />Q REMOVE EXISTING STAIR ASSEMBLY COMPLETE. <br />REMOVE EXISTING DOWNSPOUT ASSEMBLY COMPLETE. <br />REMOVE EXISTING CONCRETE WALL AS DIMENSIONED. REFERENCE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION <br />GENERAL DEMOLITION NOTES <br />1. COORDINATE DEMOLITION WITH ELECTRICAL, MECHANICAL, PLUMBING AND STRUCTURAL DISCIPLINES. <br />2. DASHED LINES INDICATE CONSTRUCTION TO BE DEMOLISHED. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH SITE CONDITIONS <br />AND PHASING PRIOR TO BEGINNING OF WORK. <br />3. THE DEMOLITION PLANS ARE DERIVED FROM EXISTING BUILDING PLANS AND SITE VISITS AND ARE INTENDED TO REASONABLY REPRESENT EXISTING <br />CONDITIONS. ACTUAL CONDITIONS MAY DEVIATE FROM THAT SHOWN ON THE DRAWINGS, THE DEMOLITION KEYNOTES IDENTIFY SPECIFIC AREAS OF <br />WORK, BUT MAY NOT BE COMPLETE IN THE IDENTIFICATION OF ALL REMOVALS. THE CONTRACTOR SHALL VERIFY ACTUAL CONDITIONS SO THAT <br />DEMOLITION IS COMPLETE. DEVIATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND THE ARCHITECT. <br />4. CONTRACTOR TO COMPLY WITH OSHA AND ALL LOCAL REGULATIONS REGARDING INVESTIGATION SURVEYS OF THE STRUCTURE PRIOR TO AND DURING <br />DEMOLITION OPERATIONS TO PREVENT ALTERATIONS TO THE BUILDING'S STRUCTURAL CAPACITY. SURVEYS OF EXISTING CONDITIONS COMPLETED BY <br />THE ARCHITECTS AND ENGINEERS DID NOT INCLUDE DESTRUCTIVE OR EXTENSIVE EXAMINATION OF EXISTING BUILDING COMPONENTS. THE <br />CONTRACTOR SHALL NOTIFY THE ARCHITECT UPON UNCOVERING ANY STRUCTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING COMPONENTS THAT ARE <br />NOT INDICATED ON THE CONSTRUCTION DOCUMENTS. NO WORK SHALL PROCEED ON THESE UNCOVERED COMPONENTS WITHOUT DOCUMENTED <br />INSTRUCTION AND DIRECTION FROM THE ARCHITECT, INCLUDING THE DEMOLITION OF ANY NEWLY EXPOSED CONCRETE, CMU , STEEL, OR OTHERWISE <br />POTENTIALLY STRUCTURAL CONDITION OR ELEMENTS (WALLS, COLUMNS, ETC.). <br />5. REMOVE FROM SITE DAILY DEMOLISHED MATERIALS, DEBRIS, AND RUBBISH. DO NOT ACCUMULATE DEBRIS ON THE FLOOR OR AT THE SITE, <br />6. ALL BUILDING COMPONENTS AND FINISHES WHICH ARE TO REMAIN IN PLACE SHALL BE PROTECTED FROM DAMAGE, AND IF DAMAGED, SHALL BE <br />REPAIRED OR REPLACED AT NO COST TO THE OWNER. <br />7. ANY REMOVAL OR ENCAPSULATING OF ASBESTOS CONTAINING MATERIALS MUST BE ACCOMPLISHED BY A LICENSED ASBESTOS ABATEMENT <br />CONTRACTOR. <br />8. SLAB SHALL BE PATCHED AND REPAIRED AFTER WORK IN THAT AREA IS COMPLETE. THE INTENT IS THAT THE REPAIR IS TO BE SMOOTH AND FLUSH WITH <br />EXISTING SLAB AND SUITABLE FOR THE INTENDED FINAL FINISH AND USE. ALL UNUSED PIPE OR DUCT PENETRATIONS SHALL BE PATCHED WITH <br />CONCRETE. BEVEL EDGES BEFORE PATCHING. MAINTAIN REQUIRED FIRE RATINGS. <br />9. REMOVE EXISTING WALLS, DOORS, FLOORING AND CEILING FINISHES BACK TO BASE BUILDING SURFACES AS INDICATED. <br />10. WHERE EXISTING PARTITIONS CONTAIN ELECTRICAL OUTLETS OR SWITCHES, COORDINATE DEMOLITION OF PARTITIONS WITH ELECTRICAL <br />CONTRACTOR. ALL ELECTRICAL TERMINATIONS TO BE PERFORMED BY ELECTRICAL CONTRACTOR. <br />11. WHERE EXISTING ELECTRICAL EQUIPMENT IS DESIGNATED TO BE REMOVED, IT SHALL BE COMPLETELY REMOVED WITH ALL ASSOCIATED BOXES, <br />SUPPORTS, AND DEVICES. ALL WIRING AND CONDUIT SHALL BE REMOVED COMPLETELY BACK TO THE FIRST ITEM LEFT UNAFFECTED BY REMOVAL. <br />CONDUIT THAT IS BURIED OR OTHERWISE INACCESSIBLE SHALL BE ABANDONED IN PLACE. IN SUCH CASES CONTRACTOR SHALL PULL ALL WIRE FROM <br />THE CONDUIT AND REMOVE ALL ITEMS PROTRUDING FROM THE FINISHED SURFACE. <br />12. ANY FIRE EXTINGUISHERS TO BE REMOVED SHALL BE SALVAGED. NEW LOCATIONS TO BE DETERMINED IN FIELD WITH THE OWNER AND THE ARCHITECT <br />IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. <br />13. FIRE PROTECTION SYSTEM SHALL REMAIN ACTIVE THROUGHOUT CONSTRUCTION. <br />14. FIRE ANNUNCIATOR PANEL BOARD TO BE PROTECTED AND KEPT IN SERVICE DURING CONSTRUCTION. <br />15. ALL UTILITY SHUT -OFFS ARE TO BE PERFORMED BY THE OWNER. <br />16. WHEN REMOVING THE FIRE ALARM SYSTEM, THE CONDUIT / WIRING REMOVAL IS TO BE PERFORMED BY THE CONTRACTOR AND ALL DEVICE REMOVAL IS <br />TO BE BY THE OWNER. <br />2008 <br />EXPANSION <br />-------------------------� <br />I <br />I <br />2001 <br />EXPANSION <br />I <br />I <br />I <br />I <br />-------------------------I <br />1995 <br />EXPANSION <br />- - - T - - - - - - - - - - - - - - - - - - - - 'l <br />I I <br />I I <br />I <br />ORIGINAL <br />j <br />WAREHOUSE <br />KEY PLAN <br />SCALE: N.T.S. <br />LINE 13 EXPANSION <br />TITLE: <br />WT-BTB ZEPHYRHILLS EXPANSION <br />ARCHITECTURAL <br />WAREHOUSE EXPANSION DEMOLITION PLAN <br />REVISION: DRAWING NO.: SHEET NO.: <br />1 A101 '- OF <br />0 <br />p" <br />3 <br />m <br />7 <br />m <br />601 <br />A B C D E F G H <br />J <br />