Laserfiche WebLink
4 <br />FL # <br />Application Type <br />Code Version <br />Application Status <br />Comments <br />Archived <br />Product Manufacturer <br />Address/Phone/Email <br />Authorized Signature <br />Technical Representative <br />Address/Phone/Email <br />Quality Assurance Representative <br />Address/Phone/Email <br />Category <br />Subcategory <br />Compliance Method <br />Florida Engineer or Architect Name who <br />developed the Evaluation Report <br />Florida License <br />Quality Assurance Entity <br />Quality Assurance Contract Expiration Date <br />Validated By <br />Certificate of Independence <br />FL10124-R20 <br />Revision <br />2017 <br />Approved <br />GAF <br />1 Campus Drive <br />Parisppany, NJ 07054 <br />(800) 766-3411 <br />mstieh@gaf.com <br />Robert Nieminen <br />lindareith@trinityerd.com <br />William Broussard <br />1 Campus Drive <br />Parsippany, NJ 07054 <br />(800) 766-3411 <br />TechnicalQuestionsGAF@gaf.com <br />Roof i ng <br />Asphalt Shingles <br />Evaluation Report from a Florida Registered Architect or a Licensed <br />Florida Professional Engineer <br />Evaluation Report - Hardcopy Received <br />Robert Nieminen <br />PE-59166 <br />UL LLC <br />10/20/2018 <br />John W. Knezevich, PE <br />` Validation Checklist - Hardcopy Received <br />FL10124 R20 COI 2017 01 COI Nieminen.pdf <br />Referenced Standard and, Year (of Standard) standard <br />Equivalence of Product Standards <br />Certified By <br />Sections from the Code <br />Product Approval Method <br />Date Submitted <br />Date Validated <br />Date Pending FBC Approval <br />Date Approved <br />ASTM D1970 <br />ASTM D3161 <br />ASTM D3462 <br />ASTM D7158 <br />TAS 107 <br />Method 1 Option D <br />09/20/2017 <br />09/27/2017 <br />09/28/2017 <br />12/12/2017 <br />Year <br />2015 <br />2016 <br />2010 <br />2011 <br />1995 <br />TRINITY ERD <br />4.3 Accessory Starter Strips: <br />4.3-1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlocker- Premium Eave/Rake Starter Strip Shingles <br />are starter strips for asphalt roof shingles. <br />4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS <br />modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- <br />inch or less. <br />4.3.3 StarterMatch„„ Sharter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and <br />Grand Sequoia® series asphalt shingles. StarterMatch'"' are installed as the second starter for Grand <br />Canyon® and Grand Sequoia® series installations. <br />S. LtMITATIONS- <br />5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the <br />Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was <br />used for permitting or design guidance unless retained specifically for that purpose. <br />5.2 This Evaluation Report is not for use in the HVHZ. <br />5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials <br />Directory for fire ratings of this product. <br />SA Wind Classification: <br />5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and <br />R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for <br />use in all wind zones up to Vasd = 150 mph (V it = 194 mph). Refer to Section 6 for installation requirements <br />to meet this wind rating. <br />5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 <br />and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to <br />Vasd = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. <br />5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a <br />mean roof height of 60 feet or less. Calculations by a qualified design professional are required for <br />conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. <br />5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building <br />Code and F.A.C. Rule 61G20-3. <br />6. INSTALLATION: <br />5.1 Underlayment: <br />6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be <br />Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. <br />6.2 Starter Shingles or Starter Strip: <br />6.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip <br />Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions. <br />6.3 Asphalt Shingles: <br />6.3.1 Installation of asphalt shingles shalt comply with the manufacturer's current published instructions, using <br />minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following <br />exceptions: <br />r Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and <br />Woodland require minimum five (5) nails per shingle. <br />Y Slateline requires minimum six (6) nails per shingle. <br />Exterior Research and Design, I.I.C. <br />Certificate of Authorization #9503 <br />Evaluation Report 01506.01.08-R21 <br />FL10124-8i9 <br />Revision 21: 08/2612016 <br />Page 4 of 6 <br />TRINITY ERD <br />EVALUATION REPORT <br />EXTERIOR RESEARCH & DESIGN, LLC. <br />Certificate of Authorization #9503 <br />353 CHRISTIAN STREET, UNIT 413 <br />OXFORD, CT 06478 <br />PHONE: (203) 262-9245 <br />FAX: (203) 262-9243 <br />GAF Evaluation Report 01506,01.08-R21 <br />1 Campus Drive FL10124-R19 <br />Parsippany, NJ 070S4 <br />)late of Issuance: 0I/03/200$ <br />SCOPE: Revision 21: 08/26/2016 <br />This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of <br />construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, <br />P-E. for use of the product Lender the Florida Building Code and Florida Building Code, Residential Volume. The <br />products described herein have been evaluated for compliance with the Sth Edition (2014) Florida Building Code <br />sections noted herein. <br />DESCRIPTION: GAF Asphalt Roof Shingles <br />LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted <br />herein. <br />CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the <br />referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. <br />Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the <br />product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete <br />review of this Evaluation Report relative to updated Code requirements with each Code Cycle. <br />ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity] ERD Evaluated" may be displayed in <br />advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. <br />INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or <br />its distributors and shall be available for inspection at the job site at the request of the Building official. <br />This Evaluation Report consists of pages 1 through 6. <br />Prepared by: <br />Robert J.M. Nieminen, P.E. y,,�S "-•• "`p?•s•` Themflesea) appearing was authorizedbyRobentheminen, <br />=' _� <<� P.E. on 08/26/2016. This does not serve as an electronically signed Florida Registration No. 59166, Florida DCA ANE1983 <br />document. Signed, sea,ed hardcoples have been transmit ed to the <br />CERTIFICATION OF INDEPENDENCE: Product Approval Administrator and to the named Gent <br />1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or <br />distributing products it evaluates. <br />2. Trinityl ERD is not owned, operated or controlled by any company manufacturing ordistributing products it evaluates. <br />3- Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for <br />which the evaluation reports are being issued, <br />4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the <br />product. <br />S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P-E. are, in any way, the Designer of Record for any <br />project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained <br />specifically for that purpose. <br />TRINITY ERD <br />6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 <br />or R905.2.5. Staples are not permitted. <br />6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are <br />required. Contact the shingle manufacturer for details. <br />6.4 Hip & Ridge Shingles: <br />6.4.1 Installation of Sea( -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal - <br />A -Ridge ArmorShield Ridge Cap Shingles shall comply with the manufacturer's current published instructions <br />with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter <br />beads of Henkel "Loctite PL 530 Roof & Flashing Sealant". <br />11.5' Sealant <br />1' (292 mm) 1" Sellanie <br />(2o mm) (25 mm) Enduft d'etanch&6 <br />i fl <br />( NI ! (305 mm) <br />Ciavo <br />6518'-75,8' (3louer <br />(168 - 194 mm) - <br />12" <br />f305 Mal) <br />6A.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with the manufacturer's current <br />published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and <br />beads of Sonneborn NPI Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. <br />J* <br />!2 211 <br />:YipY. <br />;F <br />6A.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC <br />1507.2.6 or R905.2.5. Staples are not permitted. <br />Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R21 <br />Certificate of Authorizatian 0503 FL10124-R19 <br />Revision 21: 08/26/2016 <br />Page 5 of 6 <br />TRINITY ERD <br />ROOFING SYSTEMS EVALUATION: <br />1. SCOPE: <br />Product Category: <br />Roofing <br />Sub -Category: <br />Asphalt Shingles - <br />Compliance Statement: <br />GAF Asphalt Roof Shingles, as produced by GAF, <br />have demonstrated compliance with the <br />following sections of the Florida Binding Code and Florida <br />Building Code, <br />Residential Volume through testing in <br />accordance with the following Standards. Compliance <br />is subject to the Installation Requirements and Limitations / <br />Conditions of Use set forth herein. <br />2. STANDARDS: <br />Section <br />Property <br />Standard <br />Year <br />1507.2.4, R905.23 <br />Physical Properties <br />ASTM D1970 <br />2009 <br />1507.2.5, R905.2.4 <br />Physical Properties <br />ASTM D3462 <br />2009 <br />1507.2.7.1, R905.2-6.1 <br />Wind Resistance <br />ASTM D3161 <br />2009 <br />1507.2.7A, R905.2.6.1 <br />Wind Resistance <br />ASTM D7158 <br />2008 <br />1507.2.7-1, R905.2.6-1 <br />Wind Resistance <br />TAS 107 <br />1995 <br />3. REFERENCES: <br />gn!!bt <br />Examination <br />Reference <br />Crate <br />GAF (PDM 1915) <br />Letter of Equivalency <br />Seal -A -Ridge Impact Resistant IR 01/13/2012 <br />PRI (TST 5878) <br />Physical Properties <br />GAF-025-02-01 <br />03/27/2002 <br />PRI (TST 5878) <br />ASTM D3462 <br />GAF-059-02-01 <br />09/02/(2004 <br />PRI (TST 5878) <br />ASTM D3462 <br />GAF-080-02-01 <br />OS/25/2005 <br />PRI (TST 5878) <br />Physical Properties <br />GAF-324-02-01 <br />12/01/2011 <br />PRI (TST 5878) <br />Wind Driven Rain <br />GAF-407-02-01 <br />01/21/2013 <br />UL(TST 1740) <br />ASTM D3462 <br />93NK629S <br />11/29/1993 <br />UL (TST 17401 <br />ASTM D3462 <br />99NK43835 <br />01/12/2000 <br />UL (TST 1740) <br />TAS 107 <br />94NK9632 <br />03/29/2000 <br />UL(TST 1740) <br />ASTM D3462 <br />OINK06632 <br />02/02/2001 <br />UL (TST 1740) <br />ASTM D3161, TAS 107 <br />01NK9226 <br />05/21/2001 <br />UL (TST 1740) <br />ASTM D3161 <br />OINK37122 <br />12/18/2001 <br />UL (TST 1740) <br />ASTM D3462 <br />OINK37122 <br />12/19/2001 <br />UL (TST 1740) <br />ASTM D3161, TAS 107 <br />02NK12980 <br />04/10/2002 <br />UL (TST 1740) <br />ASTM D3161, TAS 107 <br />02 NK30871 <br />09/09/2002 <br />UL (TST 1740) <br />ASTM D3161 <br />03CAS367 <br />03/11/2003 <br />UL(TST 1740) <br />ASTM D3462 <br />03NK26444 <br />10/17/2003 <br />UL (TST 1740) <br />ASTM D3462 <br />04NK13850 <br />06/07/2004 <br />UL (TST 1740) <br />ASTM D3161 <br />04NK13850 <br />06/23/2004 <br />UL(TST 1740) <br />ASTM D3161 <br />04NK30546 <br />03/10/2005 <br />UL(TST 1740) <br />ASTM D3462 <br />04NK22009 <br />05/06/2005 <br />UL (TST 1740) <br />ASTM D3161 <br />04NK22009 <br />05/09/2005 <br />UL (TST 1740) <br />ASTM D3462 <br />05NK27924 <br />02/10/2006 <br />UL (TST 1740) <br />ASTM D3161 <br />OSNK27924 <br />02/11/20015 <br />UL (TST 1740) <br />ASTM D3161, D3462 <br />OGCA18077 <br />06/05/2006 <br />UL (TST 1740) <br />ASTM D3161, D3462 <br />06CA18074 <br />06/16/2006 <br />UL (TST 1740) <br />ASTM D3161, D3462 <br />06CA35251 <br />10/18/2006 <br />UL (TST 1740) <br />ASTM D3462 <br />06CA31603 <br />12/01/2006 <br />UL (TST 1740) <br />ASTM D3161, D3462 <br />06CA41095 <br />12/27/2006 <br />UL (TST 1740) <br />ASTM D3161 <br />07NKG5228 <br />03/13/2007 <br />UL (TST 1740) <br />ASTM D3161 <br />06CA31611 <br />04/04/2007 <br />UL(TST 1740) <br />ASTM D3161 <br />06CA61148 <br />04/09/2007 <br />UL (TST 1740) <br />ASTM D3161, 03462 <br />07CA31742 <br />11/08/2007 <br />UL (TST 1740) <br />ASTM D3151, D7158, D3462 <br />OBCA06100 <br />03/13/2008 <br />UL (TST 1740) <br />ASTM D3161, D3462 <br />07CA55908 <br />04/01/2008 <br />Exterior Research and Design, LLC. <br />Evaluation Report 01506,01,08-R21 <br />Certificate of Authorization #9503 <br />FL10124-R19 <br />Revision 21: 08/26/2016 <br />Page 2 of 6 <br />TRINITY ERD <br />7. LABELING: <br />7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted <br />herein. <br />7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC <br />Table 1507.2.7.1 / R905-2.6.1. <br />8. BUILDING PERMIT REQUIREMENTS: <br />As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of <br />this product. <br />9. MANUFACTURING PLANTS: <br />Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 CIA <br />requirements. <br />10. QUALITY ASSURANCE ENTITY: <br />UL LLC —QUA9625; (847) 664-3281 <br />Exterior Research and Design, LLC. <br />Certificate of Authorization #9503 <br />- END OF EVALUATION REPORT - <br />Evaluation Report 01506.01.08-1121 <br />F1.10124-1119 <br />Revision 21: 08/26/2016 <br />Page 6 of 6 <br />TRINITY ERD <br />Entity <br />Examination <br />Reference <br />Date <br />UL (TST 1740) <br />ASTM D3161, D3462 <br />09CA10592 <br />03/26/2009 <br />UL(TST 1740) <br />ASTM D3161,D3462 <br />09CA06856 <br />05/15/2009 <br />UL (TST 1740) <br />ASTM D3161, D7158, D3462 <br />09NK06647 <br />08/01/2009 <br />UL (TST 1740) <br />ASTM D3161, D7158, D3462 <br />09CA27281 <br />08/27/2009 <br />UL (TST 1740) <br />ASTM D3161, D7158, D3462 <br />1OCA35554 <br />03/05/2010 <br />U L (TST 1740) <br />ASTM D3161, D7158, D3462 <br />IOCA13686 <br />05/15/2010 <br />UL (TST 17401 <br />ASTM D3462 <br />10CA07264 <br />05/27/2010 <br />UL (TST 1740) <br />ASTM D3462 <br />IOCA12953 <br />10/79/2010 <br />UL (TST 1740) <br />ASTM D3161,D7158, D3462 <br />IONK11951 <br />10/30/2010 <br />UL (TST 1740) <br />ASTM 03161,D7158, D3462 <br />1UNK12070 <br />11/04/2010 <br />UL (TST 1740) <br />ASTM D3161,D7158, D3462 <br />08CA06100 <br />01/30/2010 <br />UL (TST 1740) <br />ASTM D3161, D7158, D3462 <br />IOCA53934 <br />03/31/2011 <br />UL (TST 1740) <br />ASTM D3161, WIS8, D3462 <br />11CA48924 <br />10/22/2011 <br />UL (TST 1740) <br />ASTM D3161, D7158, D3462 <br />11CA47919 <br />12/03/2011 <br />UL (TST 1740) <br />ASTM D3161, D7158, D346Z <br />IICA48408 <br />12/08/2011 <br />UL (TST 1740) <br />ASTM D3161, D7158, D3462 <br />11CA48725 <br />12/09/2011 <br />UL, LLC. (TST9628) <br />ASTM D3462 <br />12CA34891 <br />10/12/2012 <br />UL, U.C. (TST 9628) <br />ASTM D3161, D7158, 03462 <br />12CA58151 <br />02/15/2013 <br />UL, LLC. (TST 9628) <br />ASTM D3161 <br />12CA38083 <br />02/26/2013 <br />UL, U.C. (TST 9628) <br />ASTM D3161 <br />13CA32332 <br />06/18/2013 <br />UL, LLC (TST 9628) <br />ASTM D3161 <br />13CA37934 <br />08/02/2013 <br />UL, LLC. (TST 9628) <br />ASTM D3161, D7158, D3462 <br />4786875675 <br />07/17/2015 <br />UL, LLC. (TST 9628) <br />ASTM D3161, D7158, D3462 <br />4787434542 <br />05/17/2016 <br />UL, LLC. (QUA 9625) <br />Quality Control <br />inspection Report, R21, Mobile, AL <br />12/28/201S <br />UL, LLC. (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Myerstown, PA <br />D2/23/2016 <br />UL, LLC. (QUA 9625) <br />Quality Control <br />inspection Report, R21, Tuscaloosa, AL <br />02/26/2016 <br />UL, LLC. (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Michigan Cry, IN <br />03/02/2016 <br />UL, LLC (QUA9625) <br />Quality Control <br />Inspection Report, R21, Shafter, CA <br />02/18/2016 <br />UL, LLC. (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Savannah, GA <br />02/24/2016 <br />UL, LLC, (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Minneapolis, MN <br />02/09/2016 <br />UL, LLC. (QUA 9625) <br />Quality control <br />Inspection Report, R21, Mt. Vernon, IN <br />02/09/2016 <br />UL, LLC. (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Baltimore, MD <br />D3/01/2016 <br />UL, LLC (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Tampa, FL <br />02/29/2016 <br />UL, LLC. (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Dallas, TX <br />02/17/2016 <br />UL, LLC. (QUA962S) <br />Quality Control <br />Inspection Report, R21, Ennis, TX <br />02/03/2016 <br />UL, LLC (QUA 9625) <br />Quality Control <br />Inspection Report, R21, Fontana, CA <br />03/03/2016 <br />4. PRODUCT DESCRIPTION: <br />4.1 Asphalt Shingles: <br />4A.1 Marquis" WeatherMaxe, <br />Royal Sovereign® and <br />Sentinel° are a fiberglass reinforced 3-tab asphalt roof <br />shingles. <br />4.1.2 Camelot®, Camelot" <br />II, Fortitude", Glenwood'", <br />Grand Canyon®, Grand Sequoia", Grand Sequoia° IR, <br />Grand Sequoia" <br />ArmorShield'", Monaco', Sienna", <br />Timberline® American Harvest', Timberline® <br />ArmorShield'" 11, Timberline® Natural Shadow®, Timberline <br />HD®, Timberline' Cool Series®, Timberline Ultra <br />HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. <br />4.13 Slateline° is a fiberglass <br />reinforced 5-tab asphalt roof shingle. <br />4.2 Hip & Ridge shingles: <br />4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge° <br />IR Impact -Resistant Ridge Cap Shingles, <br />Seal -A -Ridge® <br />ArmorShield»" Ridge Cap Shingles and Timbertexa <br />Premium Ridge Cap Shingles are fiberglass reinforced, hip <br />and ridge asphalt <br />roof shingles. <br />Exterior Research and Design, LLC. <br />Certifuate of Authorization #9503 <br />Evaluation Report 01506.01.08-R21 <br />FL10124-R19 <br />Revision 21: 08/26/2016 <br />Page 3 of 6 <br />METAL DRIP EDGE AT RAKE <br />APPLIED OVER UNDERLAYMENT <br />IN ASPHALT FELT RDILF SHEATHING NAIL DVTIMM <br />UNDERLAYMENT _ _ 6d NAD-S SHANK) 6' O,C. <br />RW *F T!`M NAIL 2 EDGES <br />6d NAILS CRINGSFYWO 4' O,C. <br />METAL DRIP <br />APPLIED <br />OVER SHEATHING <br />USE ONLY ENOUGH NAILS TO HOLD <br />UNDERLAYMENT IN PLACE UNTIL <br />SHINGLES ARE LAID <br />ROOF UNDERLAYMENT APPLICATI❑N <br />TYPICAL FOR GAF/LANDMARK SIMIGLES ETC. <br />1. ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE WITH <br />THE APPLICABLE PROVISIONS OF SECTION 1507. FBC, 2010 <br />2. FOR R®F SLOPES 2!12 UP TO 4!12 UNDERLAYMENT SHALL BE <br />A MINIMUM OF 2 LAYERS APPLIED AS FOLLOWS, (SEE ABOVE) <br />FBC 1507.3.8.1 <br />3. FOR ROOF SLOPES 442 OR GREATER UNDERLAYMENT SHALL BE A <br />MINIMUM OF ONE LAYER OF UNDERLAYMENT FELT APPLIED AS FOLLOWS, <br />STARTING AT THE EAVE UNDERLAYMENT SHALL BE APPLIED SHINGLE <br />FASHION PARALLEL TO THE EAVE, LAPPED 2' AND FASTENED <br />SUFFICIENTLY TO STAY IN PLACE UNTIL SHINGLES ARE LAID. <br />FBC 1507.3.8.2 <br />4. DRIP EDGE, ➢RIP EDGE SHALL BE PROVIDE➢ AT EAVES AND GABLES <br />OF SHINGLE ROOFS AND OVERLAPPED A MINIMUM OF 2 INCHES <br />EAVE DRIP EDGES SHALL EXTEND 1/4' BELOW SHEATHING AND EXTEND <br />BACK ON THE ROOF A MINIMUM OF 2 INCHES. DRIP EDGE SHALL BE <br />MECHANICALLY FASTENED A MAXIMUM OF 12' ON CENTER. <br />FBC 1507.3.8.3 <br />9' STARTER STRIP OR <br />COURSE OF INVERTED <br />SHDJGLES <br />150 ASPHALT FELT <br />UNDERLAYMENT <br />�a..35 <br />STEEL PLYCL <br />8d IRS NA <br />PLYWOOD NAIL PATTERN (ROOF) <br />15/32' CDX SHEATHING SHALL BE NAILED W/ 8d IRS NAILS @ 6' ❑,C, <br />@ EDGES AND 8' ❑,C, MAX, IN THE FIELD, USE 1/2' STEEL PLYCLIPS, <br />METAL DRIP EDGE <br />AT RAKE APPLIED <br />OVER UNDERLAYMENT <br />START TMORD COARSE WITH <br />FILL STRIP HINDS FIRST <br />TAB <br />— START SECOND COURSE <br />WITH FULL STRIP MINUS <br />1/2 TAB <br />START FIRST COURSE WITH <br />FULL STRIP <br />R❑❑FING APPLICATI❑N <br />1. ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE WITH THE <br />APPLICABLE PROVISIONS OF SECTION 1507 FBC AND THE <br />MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />2. ASPHALT SHINGLES SHALL BE USED ONLY ON ROOF SLOPES OF <br />2,12 OR GREATER, FOR ROOF SLOPES FROM 2,12 UP TO 4,12 <br />DOUBLE UNDERLAYMENT APPLICATION IS REQUIRED. <br />3, UNLESS OTHERWISE NOTED, REQUIRED UNDERLAYMENT SHALL <br />CONFORM WITH ASTM D 226, TYPE 1, OR ASTM 4869, TYPE I <br />FBC 1507.3.3 <br />4, SELF ADHERING BITUMEN SHEET SHALL COMPLY WITH ASTM D225 <br />OR ASTM D3462, <br />FBC 1507.3.4 <br />5, ASPHALT SHINGLES SHALL HAVE SELF SEAL STRIPS OR BE INTERLOCKING, <br />AND COMPLY WITH ASTM D225 OR ASTM 13462, <br />FBC 1507.3.5 <br />6. FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED, STAINLESS <br />STEEL, ALUMINUM, OR COPPER ROOFING NAILS MINIMUM 12 GA (0,105 INCH <br />SHANK WITH A MINIMUM 3/8- DIAMETER HEAD, OF A LENGTH TO PENETRATE <br />THROUGH THE ROOFING MATERIALS AND A MINIMUM OF 3/4' (19101101) INTO THE <br />ROOF SHEATHING. WHERE THE ROOF SHEATHING IS LESS THAN 3/4' THICK <br />THE NAILS SHALL PENETRATE THROUGH THE SHEATHING. <br />FBC 1507.3.6 <br />7. ASPHALT SHINGLES SHALL BE SECURED TO THE ROOF WITH NOT LESS FOUR <br />FASTENERS PER STRIP OR TWO FASTENERS PER INDIVIDUAL SHINGLE. UNLESS <br />OTHERWISE NOTED ATTACHMENT OF ASPHALT SHINGLES SHALL CONFORM WITH <br />ASTM D3161 (MODIFIED TO 110 MPH) OR M-DC PA 107-95. <br />FBC 15073,7 <br />