1 <br />LO <br />U <br />U, <br />42'-8" <br />5'-1" <br />i 23 SH 1 1 25 SH I <br />ELECTRICAL PLAN <br />1 /4"=1'-031 <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE <br />ALL APPLICABLE LOCAL ORDINANCES AND IN COOPERATION WITH THE <br />UTILITY COMPANIES. <br />2. COORDINATE ALL WORK WITH ALL TRADES. <br />3. MOUNT ALL OUTLETS AND RECEPTACLES PLUMB AND FLUSH WITH WALLS. <br />4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN OTHERWISE. <br />5. INSTALL ELECTRICAL CABLE, WIRE AND CONNECTORS AS INDICATED IN <br />ACCORDANCE WITH THE MANUFACURERS WRITTEN INSTRUCTION,THE <br />APPLICABLE REQUIREMENTS OF NEC AND THE NATIONAL ELECTRICAL <br />CONTRACTORS ASSOCIATION "STANDARD OF INSTALLATION" AND <br />IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE <br />THAT PRODUCTION SERVE THE INTENDED FUNCTIONS. <br />6. ALL WIRE SHALL BE STD. #10 AND #12 AND SHALL BE ROMEX OR NM <br />CABLE TYPE B OR APPROVED EQUAL. <br />7. COORDINATE ELECTRICAL REQUIREMENTS FOR A/C WITH A/C CONTRACTOR. <br />8. ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFCI <br />(ARC FAULT CURCUIT INTERRUPTER) PROTECTED CIRCUIT. <br />9. COMBINATION SMOKE DETECTOR/CARBON MONOXIDE DETECTOR TO BE <br />LOCATED WITH -IN 10' OF EACH BEDROOM <br />10. PROVIDE MINIMUM 75% HIGH -EFFICIENCY LIGHTING. (FBC-ENERGY CONSERVATION R404) <br />200 AMP MAIN BREAKER <br />40 CIRCUIT SURFACE MOUNT <br />PANEL <br />METER CAN BY <br />ELECTRIC UTILITY CO.- AMP <br />2" C WITH 3-4/0 THW AL <br />TO UNDERGROUND #4 CU. GROUND <br />SERVICE BY ELECTRIC <br />UTILITY CO. <br />TO COLD WATER LINE <br />5/8" X 8" GROUND LINE <br />(PASCO CO. ATTACH TO FOOTER REBAR) <br />(BACK TO BACK SERVICE/OFFSET SIMILAR) <br />EX. 200 AMP ELECTRICAL RISER <br />N.T.S. <br />100 AMP MAIN BREAKER <br />20 CIRCUIT SURFACE MOUNT <br />PANEL <br />#4 SER CU. <br />OR <br />100 #2 SER ALUMN. <br />AMP <br />BEDROOM EMERGENCY EGRESS SHALL BE DIRECTLY TO ❑UTSIDE <br />EGRESS WIND❑WS SHALL BE SIZED, LOCATED AND INSTALLED PER FBC 2017 <br />ALL BEDROOM ELECTRICAL OUTLETS MUST BE ARC -FAULT <br />ARC FAULT PROTECTED OUTLETS SHALL BE <br />INSTALLED PER NEC 210,12(B), <br />GFI PROTECTED CIRCUITS SHALL BE INSTALLED IN GARAGE ADDITI❑NS, <br />BATHROOMS & KITCHENS, LAUNDRY ROOMS AND ❑UTSIDE RECEPTACLES <br />I HEREBY CERTIFY THAT I HAVE REVIEWED <br />THIS PLAN AND FOUND IT TO BE IN <br />COMPLIANCE WITH ASCE 7-10, & FBC 2017 <br />(6TH. EDITION). <br />0 � 1� t <br />I0.63608 <br />0. <br />•.. <br />OR 10p'40 <br />••••....•° U� <br />o0 <br />�t t 1 11i®® <br />PROFESSIONAL ENGINEER SEAL <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICENSE NUMBER 53608 <br />Plans By: <br />Larry deMontmollin <br />90 Country Club Lane <br />Mulberry, FL 33860 <br />Phone: (863)397-7525 <br />DATE: 02-08-19 <br />DRAWN BY: L.E.D. <br />REVISION: <br />DATE: <br />R01 <br />RO 2 <br />RO 3 <br />RO 4 <br />PROJECT ADDRESS: <br />BUTTERFIELD INVESTMENTS, INC. <br />501018th. STREET <br />ZEPHYRHILLS, FL. 33542 <br />CONTRACTOR: <br />HOUSE PLAN <br />ELECTRICAL PLAN <br />DWG, BF-002-A6 REV. 0 <br />