My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5023 Summerhill Dr
Zephyrhills
>
Building Department
>
Building Plans
>
5023 Summerhill Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 9:54:41 PM
Creation date
2/18/2025 3:29:40 PM
Metadata
Fields
Template:
Building Plans
Street #
5023
Location
Summerhill Dr
Contractor
Bailey Contracting
Building Plans - Permit #
19541
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EGRESS <br />2-25 SH <br />EGRESS <br />25 SH <br />r <br />I <br />1 I ' 1�1: <br />:w 1 1 <br />200 AMP MAIN BREAKER <br />40 CIRCUIT SURFACE MOUNT <br />PANEL <br />METER CAN BY <br />ELECTRIC UTILITY CO O AMP <br />L-2" C WITH 3-4/0 THW AL <br />TO UNDERGROUND #4 CU. GROUND <br />SERVICE BY ELECTRIC <br />U1ILITY CO. <br />TO COLD WATER LINE <br />5/8" X 8" GROUND LINE <br />(PASCO CO. ATTACH TO FOOTER REBAR) <br />(BACK TO BACK SERVICE/OFFSET SIMILAR) <br />A EX. 200 AMP ELECTRICAL RISER <br />N.T.S. <br />100 AMP MAIN BREAKER <br />20 CIRCUIT SURFACE MOUNT <br />PANEL <br />#4 SER CU. <br />OR <br />100 #2 SER ALUMN. <br />AMP <br />ELECTRICAL PLAN <br />1 /4"=1'-0" <br />FLOOR PLAN <br />1 /4"=1'-0" <br />25 SH <br />EGRESS <br />N <br />N <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE <br />ALL APPLICABLE LOCAL ORDINANCES AND IN COOPERATION WITH THE <br />UTILITY COMPANIES. <br />2. COORDINATE ALL WORK WITH ALL TRADES. <br />3. MOUNT ALL OUTLETS AND RECEPTACLES PLUMB AND FLUSH WITH WALLS. <br />4. RECEPTACLES SHALL BE MOUNTED 12" AFF UNLESS SHOWN OTHERWISE. <br />5. INSTALL ELECTRICAL CABLE, WIRE AND CONNECTORS AS INDICATED IN <br />ACCORDANCE WITH THE MANUFACURERS WRITTEN INSTRUCTION,THE <br />APPLICABLE REQUIREMENTS OF NEC AND THE NATIONAL ELECTRICAL <br />CONTRACTORS ASSOCIATION "STANDARD OF INSTALLATION" AND <br />IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE <br />THAT PRODUCTION SERVE THE INTENDED FUNCTIONS. <br />6. ALL WIRE SHALL BE STD. #10 AND #12 AND SHALL BE ROMEX OR NM <br />CABLE TYPE B OR APPROVED EQUAL. <br />7. COORDINATE ELECTRICAL REQUIREMENTS FOR A/C WITH A/C CONTRACTOR. <br />8. ALL RECEPTACLES IN SLEEPING ROOMS SHALL BE ON AN AFCI <br />(ARC FAULT CURCUIT INTERRUPTER) PROTECTED CIRCUIT. <br />9. COMBINATION SMOKE DETECTOR/CARBON MONOXIDE DETECTOR TO BE <br />". LOCATED WITH -IN 10' OF EACH BEDROOM <br />BEDROOM <br />EMERGENCY EGRESS <br />SHALL <br />BE DIRECTLY <br />TO ❑UTSIDE <br />EGRESS <br />WIND❑WS SHALL BE <br />SIZED, <br />LOCATED AND <br />INSTALLED PER FBC 2017 <br />ALL BEDROOM ELECTRICAL OUTLETS MUST BE ARC -FAULT <br />ARC FAULT PROTECTED OUTLETS SHALL BE <br />INSTALLED PER NEC 210,12(B), <br />GFI PROTECTED CIRCUITS SHALL BE INSTALLED IN GARAGE ADDITI❑NS) <br />BATHROOMS & KITCHENS, LAUNDRY ROOMS AND ❑UTSIDE RECEPTACLES <br />,%IIIIIIII" <br />S, <br />\v YY ii I' <br />No.53608 <br />S OF w� <br />4 © 1oil,+�w.°"` <br />d� Ito S� <br />C � <br />1 j:: 1 I I1��N.1 <br />ENGINEER OF RECORD <br />David W. Smith P.E. <br />FLORIDA LICENSE NUMBER 53608 <br />Plans By: <br />Larry deMontmollin <br />90 Country Club Tan <br />Phones (863)397-7525 <br />DATE: 02-15-18 <br />DRAWN BY: LED. <br />REVISION: <br />R-1 <br />R- 2 <br />R- 3 <br />R- 4 <br />DATE: <br />PROJECT ADDRESS: <br />BUTTERFIBLD INVBSTMENTS, INC. <br />5023 SUMMER HILL DR <br />ZEPHYRHILIS, F4 33542 <br />CONTRACTOR: <br />JoBL BAILEY <br />HousB PLAN <br />ELECTRICAL PLAN <br />DWG. 2WB=7 REV. 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.