R <br />GENERAL NOTES: <br />PLAN NOTES; <br />(Q <br />HAZARDOUS L❑CATIONS <br />d <br />1, WIND DESIGN SPEED = 110 MPH (3 sec gust) <br />2, WIND IMPORTANCE FACTOR = 1,15 FOR ENCLOSED STRUCTURE <br />GROUP "B" <br />3. WIND EXPOSURE CATEGORY= "B" <br />4, INTERNAL PRESSURE C❑EFFICIENT = +18/-18 (ENCLOSED BLDG) <br />APPLICABLE CODES <br />THE FOLLOWING CODES WILL APPLY TO CONSTRUCTION <br />2007 FLORIDA BUILDING CODE w/2009 SUPPLEMENTS <br />2007 FLORIDA BUILDING CODE., PLUMBING w/2009 SUPPLEMENTS <br />2007 FLORIDA BUILDING CODE, MECHANICAL w/2009 SUPPLEMENTS <br />2007 FLORIDA BUILDING CODE,, FUEL GAS w/2009 SUPPLEMENTS <br />2007 <br />FLORIDA <br />ENERGY EFFICIENCY CODE FOR <br />BUILDING <br />C❑NSTRUCTI❑N <br />2007 <br />FLORIDA <br />ACCESSIBILITY CODE <br />BUILDING <br />CONSTRUCTION <br />2009 <br />NATIONAL <br />ELECTRICAL CODE <br />2009 <br />NFPA 101 <br />LIFR SAFETY CODE <br />2007 <br />FLORIDA <br />FIRE PREVENTION CODE <br />DESIGN CRITERIA; <br />ALLOWABLE SOIL BEARING=2000psf (VERIFY BY SOILS TESTING COMPANY) <br />CONCRETE FOR FOOTINGS, BOND BEAMS, FILLED CELLS AND CAST -IN -PLACE <br />COLUMNS SHALL HAVE MIN. C❑MPRESSIVE STRENGTH OF 3000 psi @ 28 DAYS. <br />CONCRETE FOR WALKS AND SLAB ON GRADE SHALL HAVE A MIN. C❑MPRESSIVE <br />STRENGTH OF 3000 psi @ 28 DAYS (CHECK LOCAL CODES ON PSI) <br />CONCRETE BLOCK Fm=2000psi (TYPE I) <br />MORTAR ASTM C270 Ft= 2000psl (TYPE S) <br />REINFORCING STEEL SHALL COMPLY WITH ASTM "A615 <br />GRADE 40 (Fy=40,000psi) <br />ANCHOR BOLTS SHALL COMPLY WITH ASTM A36 STEEL <br />FOOTING SHALL BE PLACED IN UNDISTURBED SOIL OR CLEAN, WELL GRADED BACKFILL <br />MATERIAL, FIRMLY MAX DRY DENSITY COMPACTED TO 95% <br />DESIGN SHALL COMPLY WITH THE STANDARD FOR HURRICANE RESISTANT <br />RESIDENTIAL CONSTRUCTION (SSTD 10-99) <br />INTERIOR REQUIREMENTS <br />FLAME SPREAD/SMOKE DEV.-EXIT ACCESS UNSPRK+ TYPE 'B' FLAMESPREAD 26-75 SMOKE DEV, 0-450 <br />FLAME SPREAD/SMOKE DEV.-EXIT ACCESS SPRK, TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV, 0-450 <br />FLAME SPREAD/SMOKE DEV.-OTHER SPACES UNSPRKI TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV. 0-450 <br />FLAME SPREAD/SMOKE DEV.-OTHER SPACES SPRKI TYPE 'C' FLAMESPREAD 76-200 SMOKE DEV. 0-450 <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND <br />THEREFORE AGREES TO HOLD HARMLESS, MEMNITY, AND DEFEND DESIGNER FROM ALL <br />CLAIMS, LOSSES AND EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT <br />OF OR RESULTING FROM THE PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO <br />PROVIDE ERROR FREE CONSTRUCTION DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE <br />DESIGNDER WILL NOT BE LIABLE FOR COST OF REPAIRS OR DELAY TO THE CONSTRUCTION. <br />6 <br />1. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE 2007 FLA. BLDG. <br />CODE, 2009 SUPPLEMENTS AND SHALL FOLLOW ALL LOCAL CODES,RULES, <br />REGULATIONS, AND ❑RDIANCES. <br />2. ALL WORK SHALL BE COMPLETED IN A NEAT AND CRAFTSMANLIKE MANNER <br />AND UPON COMPETITION SHALL BE INSPECTED BY THE GENERAL <br />REGULATIONS, AND ❑RDIANCES. <br />3. CONTRACTOR SHALL COMPLY WITH ALL OSHA REQUIREMENTS. <br />4. CONTRACTOR SHALL ARRANGE FOR AND PAY FOR ALL REQUIRED PERMITS. <br />5. ALL SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR THE DISPOSAL OF <br />THEIR RELATED REFUSE. <br />6. ALL CONDITIONS, DRAWINGS, DIMENSIONS, ETC, SHALL BE FIRST VERIFIED BY <br />THE GENERAL BLDG, CONTRACTOR AND SUB -CONTRACTORS PRIOR TO THE <br />ORDERING OF MATERIALS AND CONSTRUCTION FOR DELETIONS, ERRORS, <br />AND/OR ❑MISSIONS. FAILURE TO NOTIFY THL ENGINEER SHALL RELIEVE THE <br />ENGINEER FROM RESPONSIBILITY AND ANY CORRECTIVE COSTS, <br />7. ANY ALTERATIONS OR DEVIATION FROM THESE DRAWINGS SHALL BE MADE <br />WITH THE COMBINED APPROVAL OF THE OWNER AND THE ENGINEER. ITEMS <br />NOT APPROVED SHALL RELIEF THE OWNER AND THE ENGINEER OF <br />RESPONSIBILITY AND ANY COSTS TO CORRECT THE ALTERATION OR <br />DEVIATION. <br />8. CONTRACTOR SHALL PROVIDE ALL NECESSARY AND REQUIRED BLOCKING, <br />BRACING AND SECURING OF ALL MATERIAL AND EQUIPMENT AS REQUIRED. <br />9, ALL WOOD SPECIFIED SHALL BE PINE, FIR OR SPRUCE NO. 2 GRADE OR <br />BETTER AND PRESSURE TREATED WHERE REQUIRED. <br />10. ALL PREFABRICATED BRACKETS AND CONNECTORS TO BE INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. <br />11. ALL WINDOWS AND DOORS TO BE INSTALLED PER MFR. INSTRUCTIONS/ <br />SPECIFICATION AND MUST BE RATED TO SATISFY SPECIFIED WIND PRESSURES, <br />12. THE ENGINEER IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, <br />OR SCHEDULE. <br />13. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. <br />LARGE SCALE DETAILS SHALL TAKE PRECEDENCE OVER SMALLER SCALE <br />DRAWINGS. <br />14. CONTRACTOR SHALL OBTAIN A CERTIFICATE OF OCCUPANCY FROM THE <br />AUTHORITY HAVING JURISDICTION UPON COMPLETION OF THIS WORK, <br />15. CONTRACTOR SHALL GUARANTEE ALL WORK FOR A MINIMUM OF ONE YEAR <br />AFTER COMPLETION OF WORK. <br />CODE REQUIREMANTS <br />FLORIDA BUILDING CODE <br />2007 ED, w/2009 SUPPLEMENTS <br />OCCUPANCY <br />GROUP "B" BUSINESS <br />SPECIAL OCCUPANCY <br />STORAGE SEPARATION (1) HOUR <br />REQUIREMENTS <br />CONSTRUCTION TYPE <br />TYPE II, UNPROTECTED <br />ALLOWABLE AREA <br />AREA; 2880 SF <br />& HEIGHT <br />HEIGHT; <20' <br />FIRE RESISTANCE - <br />C❑RRI (1) HOUR <br />SEPARATION p, <br />CORRI B-CLG, (1) HOUR <br />FIRE ALARM SYSTEM <br />MANUA ULL STATIONS @ <br />EXIT D MOKE DECTECTORS <br />IN SUP D RETURN AIR DUCTS,ST❑RAG NNS <br />MS, RESTRO❑MS <br />EMERGENCY LIGHTING <br />BATTERY POWERED EMERGENCY <br />LIGHTING W/INTEGRAL CHARGER <br />IN ALL OCCUPIED AREA'S <br />EXIT LIGHTS <br />BATTERY POWERED EXIT <br />LIGHTING W/INTEGRAL CHARGER <br />& TEST LIGHT <br />FIRE SUPPRESSION <br />PORTABLE FIRE EXTINGUISHERS <br />KIDDE <br />MIN. NUMBER OF EXITS <br />(2) REQUIRED <br />(2) PROVIDED <br />MAXIMUM TRAVEL <br />75' W/ A 20 FT MAXIMUM <br />DISTANCE <br />DEAD END <br />MIN. CEIRRI-DOR <br />44" <br />MIN CLEAR OPENING <br />32" <br />OF EXIT DOORS (IN); <br />1. A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE <br />ON THE SITE FOR THE BUILDING INSPECTORS USE. OR, ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY REQUIRED SETBACKS, <br />2. ALL PLUMBING, ELECTRICAL, MECHANICAL ROUGH -INS MUST BE COMPLETE, <br />INSPECTED, AND APPROVED BEFORE REQUESTING THE FRAMING INSPECTION. <br />3. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND <br />NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. <br />THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. FBC 104.2.6 <br />4. CONDENSE AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST 1'-0' AWAY FROM <br />BUILDING SIDE WALLS, FBC 1503.4.4 <br />5. IRRIGATION/SPRINKLER SYSTEMS INCLUDING RISERS AND SPRAY HEADS SHALL NOT <br />BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALL. FBC 1503.4.4 <br />6. TO PROVIDE FOR INSPECTIONS FOR TERMITE FOR INFESTATION, BETWEEN WALL COVERING <br />AND FINAL EARTH SHALL NOT BE LESS THAN 6 INCHES. <br />7. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE <br />FBC 1816.1.1 <br />8. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING <br />SPACES BOXED OR FORMED, FBC 1816.1.2 <br />9. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., <br />SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS <br />MUST BE OF A SIZED AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF S❑IL AFTER <br />THE INITIAL TREATMENT. FBC 1816.1.3 <br />10, MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />REQUIRED. FBC 1816.1.4 <br />11, CONCRETE ❑VERP❑UR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT, FBC 1816.1.5 <br />12. S❑IL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0' OF THE STRUCTURAL SIDE WALL. FBC 1816.1.6 <br />13, ALL EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED. FBC 1816.1.6 <br />14. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION TREATMENT. FBC 1816.1.7 <br />WITHIN 1'-0' OF THE STRUCTURAL SIDE WALL. FBC 1816.1.6 <br />15. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT BY <br />A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY WILL BE <br />ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE, 'THE BUILDING HAS RECEIVED <br />A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. THE <br />TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES.' FBC 1816.1.7 <br />16. AFTER ALL WORK IS COMPLETE, LOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0' OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES TUB <br />TRAP BOXES, FORMS, SHORING, AND OTHER CELLULOSE CONTAINING MATERIAL. FhC 2303.1.3 <br />17. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0' OF ANY BUILDING OR PROPOSED BUILDING. FBC 2303.1.4 <br />WINDOW AND DOOR NOTES; <br />1. ALL EXTERIOR WINDOWS AND GLASS DOORS ARE REQUIRED TO BE TESTED IN <br />ACCORDANCE WITH ANSI/AMMA/NWWDA 101 /IS2 STANDARD AND BEAR AN <br />AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER PERFORMANCE <br />CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />2 ALL EXTERIOR WINDOWS AND DOORS, SHALL BE ANCHORED PER PUBLISHED <br />MANUFACTURER'S RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURE SPECIFIED. <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR <br />THE PURPOSES OF GLAZING. (FBC 2403,2) <br />1, GLAZING IN SWINGING DOORS AND FIXED AND SIDING PANALS OF SLIDING (PATIO) <br />DOOR ASSEMBLIES AND OTHER FACILITIES WHERE SUCH GLAZING IS LOCATED 36' <br />INCHES OR LESS MEASURED HORIZONTALLY FROM A STANDING SURFACE. <br />2. GLAZING IN DOORS AND WALLS OF ENCLOSURES FOR HOT TUBS, WHIRL POOLS, <br />SAUNAS, STEAM ROOMS, BATH TUBS, SHOWERS OR WALKING SURFACE WITHIN THE <br />ENCLOSURE AND WHERE THE BOTTOM OF THE EXPOSED GLAZING IS LESS THAN <br />60 INCHES MEASURED VERTICALLY ABOVE SUCH STANDING OR WALKING SURFACES, <br />3. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR <br />WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR <br />IN A CLOSED POSITION AND THE WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES <br />ABOVE THE FLOOR OR WALKING SURFACE. <br />EXCEPTIONiGLAZING IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A <br />CLOSED P❑SITI❑N IN GROUP R-3/R-2 SHALL BE SUBJECT TO 2405.2.1 (4) <br />4. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL OTHER THAN THOSE <br />LOCATIONS IN ITEMS 2 AND 3 ABOVE, THAT MEETS ALL THE FOLLOWING <br />C❑NDITI❑NSA <br />4.1 EXPOSED AREA OF AN INDIVIDUAL FIXED OR OPERABLE PANE GREATER <br />THAN 9 S.F. <br />4.2 BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR <br />4.3 TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR <br />4.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF <br />THE PLANE OF THE GLAZING <br />5. ALL GLAZING IN RAILINGS REGARDLESS OF AREA OR HEIGHT OR AREA ABOVE A <br />WALKING SURFACE INCLUDING STRUCTURAL BALUSTER PANELS AND <br />NON-STRUCTURAL IN -FILL PANELS. <br />6. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING <br />POOLS AND SPAS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 18 (1) <br />LESS THAN 60 INCHES ABOVE A WALKING SURFACE ON THE POOL SIDE OF THE <br />GLAZING AND (2) THE GLAZING IS WITHIN 60 INCHES HORIZONTALLY OF THE <br />WATERS EDGE OF A SWIMMING POOL OR SPA. THIS SHALL <br />BE APPLY TO SINGULAR GLAZING AND ALL PANES IN MULTIPLE GLAZING. <br />SEE FBC 2405.2 FOR PRODUCTS, MATERIALS AND USES THAT ARE EXEMPT FROM <br />THE ABOVE HAZARDOUS LOCATIONS. <br />EXTERIOR WINDOWS & DOORS <br />1. ALL EXTERIOR WINDOWS AND GLASS DOORS ARE REQUIRED TO BE TESTED IN <br />ACCORDANCE WITH ANSI/AMMA/NWWDA 101 /IS2 STANDARD AND BEAR AN <br />AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER PERFORMANCE <br />CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />2. ALL EXTERIOR WINDOWS AND DOORS WHERE BUCK THICKNESS IS LESS THAN 1 1/2' <br />THICK, SHALL BE ANCHORED THROUGH THE JAM INTO THE STRUCTURAL SUBSTRATE. <br />3. ALL EXTERIOR WINDOWS AND DOORS WHERE BUCK THICKNESS IS 1 1/2' OR GREATER, THE <br />BUCK MUST BE ATTACHED IN A MANNER THAT TRANSFERS THE LOAD DIRECTLY TO THE <br />STRUCTURE, WINDOWS AND DOORS SHALL BE ANCHORED THROUGH THE JAM INTO THE WOOD BUCK, <br />4. THE WINDOW BUCK SHALL EXTEND BEYOND THE INTERIOR LIP OF THE WINDOW. <br />5. MULLIONS AND ADJACENT DOOR ASSEMBLIES ARE REQUIRED TO BE TESTED OR <br />ENGINEERED TO TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INDEX <br />CONTRACTOR IS TO VERIFY ANY STRUCTURAL <br />OR CODE REQUIREMENTS PRIOR TO CONSTRUCTION, AND TO BUILD ACCORDINGLY. <br />CONTRACTOR TO VERIFY DIMENSIONING PRIOR TO CONSTRUCTION AND TO <br />NOTIFY OWNER & ENGINEER FOR ANY DIMENTI❑NAL CORRECTIONS PRIOR <br />TO CONSTRUCTION. <br />BUILD - OUT <br />SHT# ARCHITECTURAL <br />1 Al TITLE / GENERAL INFORMATION <br />2 A2 FLOOR PLAN - FIRE SAFETY PLAN <br />3 A3 PLUMBING - WALL SECTIONS <br />4 A4 ELECTRICAL PLAN <br />Please be advised this review of plans submitted is s <br />on" to assist the contractor in compliance wNh <br />applicable fee safety codes. This review is not intended <br />to be a final appcval of the submitted plans. It is the <br />cwtaclor's sole responsibility to ensure that the plans are in <br />cornpleb compliance with al applicable NFPA codes and <br />loaf adinences. In the went that further examination or <br />she inspection reveals areas of non -Compliancy:, it shall be <br />CM*acws sole responsibility, at their sole expense to <br />bring those areas in compliance. The City assumes no <br />regvm biMty for the contractor's failure to be in compliance <br />with aN applicable NFPA Codes and local ordinances. <br />iUBM=ED PLAN(S) HAV BEEN REVIEWED <br />BY ZEPHYRHILLS AL'S OFFI <br />Date: <br />Rediewer: <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORIDA BUILDWG <br />CODE, NATIONAL ELECTRIC CODE AND <br />CITY OF ZEPHYR HILLS ORDINANCES <br />DESIGN PLANS BY RICK <br />813- 765-9793 <br />ENGINEERS NOTES JOB NO. <br />2007-C10 <br />SCALE DATE SHEET 1 OF 24 <br />24 1 E 2997 <br />DESIGN/DRAWN CHECKED A 1 <br />R. GOLLHARDT <br />�I <br />