0 <br />z <br />U Cl) <br />z m <br />0 Fy <br />Oon J <br />LL <br />zUti <br />W <br />® C� ~o <br />�"� (Az U) <br />0 N <br />W Q M <br />Lf) <br />OUTSIDE AIR CALCULATION HVAC EQUIPMENT SCHEDULE NOTE: ELECTRIC REQUIREMENT FOR EQUIPMENT TO BE A Q QM <br />FIELD VERIFIED BY ELECTICTIAN/MECHANICAL CONTRACTOR. < >_ W <br />MN. In <br />AH CATEGORY SQ. FT. AREA CFM/PRSN + CFM/FT OIA. CFM 00 CO 11- <br />MFG.MODEL NO. TOTAL-BTUH <br />AH SEER O!A <br />TONNAGE SENSIBLE LATENT KW VOLTAGE LRA/RLA MCA/MOCP CFM CY } 0 <br />LL <br />1 School 1219 7.5 x 60 + .06 + 1219 523 "OR EQUAL" "OR EQUAL" COOLING/HEATING �R CFM <br />2 School 1219 7.5 x 60 + .06 + 1219 523 1 EXISTING EXISTING 5 TONS 60,000 34,121 42,600 17,400 14.0 10 KW 208/230-60-1 134/25 32.8/50 1980 542 ui <br />3 School 1149 0 x 0+ .06 x 1149 38 <br />TOTAL OA 1084 2 FRANKLIN or Eqv. GSX14060/ASPT61 5 TONS 60,000 34,121 42,600 17,400 14.0 10 KW 208/230-60-1 134/25 32./50 1980 542 co <br />M <br />r <br />3 FRANKLIN or Eqv. GSX14025/ARUF29 2 TONS 23,600 17,060 17,228 6,372 14.0 5 KW 208/230-60-1 58.3/13.5 17.6/30 700@LOW 0 <br />FAN SCHEDULE <br />MFG. <br />TYPE "OR <br />CFM <br />VOLTS <br />DUCT DIA. <br />EQUAL" <br />1 <br />BROAN <br />OR EQUAL <br />CEILING EXHAUST FAN <br />140 <br />120 <br />6 INCHES <br />1 <br />BROAN <br />OR EQUAL <br />CEILING EXHAUST FAN <br />140 <br />120 <br />6 INCHES <br />AIR BALANCE SCHEDULE <br />AH1 <br />OUTSIDE AIR INTAKE CFM +542* <br />SUPPLY AIR CFM +1980 <br />RETURN AIR CFM -1457 <br />EXHAUST AIR CFM -140 <br />TOTAL BUILDING PRESSURE 11011 CFM <br />AH2 <br />OUTSIDE AIR INTAKE CFM +542* <br />SUPPLY AIR CFM +1980 <br />RETURN AIR CFM -1577 <br />EXHAUST AIR CFM -140 <br />TOTAL BUILDING PRESSURE 11011 CFM <br />* AH1-2 INCLUDES AH3 OA <br />DIFFERENTIAL <br />PRESSURE GAUGE <br />AIR HANDLING <br />UNIT FILTE <br />SUPPLY AIR FLEXIBLE SECTI <br />DUCT-7 CONNECTION <br />FLOOR <br />DRAIN <br />CEILING/ <br />O <br />HORIZONTAL <br />AIR HANDLING UNIT <br />NOT TO SCALE <br />12" BASE RAILS <br />PROVIDED BY AHU <br />MANUFACTURER <br />DRAIN <br />OUTSIDE AIR DUCT <br />MOTORIZED DAMPER <br />ACCESS <br />DOOR <br />° LINED SHEETMETAL <br />RETURN AIR PLENUM <br />'ING PAD <br />TE <br />FLEXIBLE <br />CONNECTION <br />RETURN AIR <br />DUCT <br />TO AIR HANDLER - <br />THRU FIRST FLOOR <br />CEILING SPACE <br />INSULATED SUCTION <br />LINE (NO JOINTS ALLOWED) <br />SEE FLOOR PLAN <br />FOR PIPE SIZES <br />LIQUID LINE —/ <br />(NO JOINTS ALLOWED) <br />DRILL BLOCKING TO FIT <br />OUTSIDE OF REFRIG. LINES <br />WATER TIGHT <br />-METAL BOOT PAINTED TO <br />MATCH EXTERIOR FACADE <br />IF REFRIG. LINES RUN <br />IN CEILING SPACE <br />FASTENED TO WALL BOTH <br />'SIDES W/ 1"Xi/8" <br />SCREWS 18" APART <br />-SUCTION CONNECTION <br />-LIQUID CONNECTION <br />-COND. UNIT TO BE SECURED <br />WITH (4) KWIK BOLT 0 3/8"x3" <br />WITH 2 1/2" MIN EMBED <br />4" CONCRETE SLAB <br />— CAULK W/3M <br />CP-25 OR EQUAL <br />PROVIDE 4" PVC SCH-40 <br />SLEEVE IF REFRIG. LINES <br />RUN UNDER SLAB <br />CONDENSING UNIT MOUNTING DETAIL <br />NTS <br />chg <br />rn m go <br />z <br />X N J <br />Cc <br />la <br />> 0go <br />:z d 0 <br />Lu <br />v <br />m <br />u � <br />� <br />1 U <br />ti o a <br />-0 <br />}- U <br />-0 in m <br />Y.0 <br />� <br />CON <br />U1 \QU-J <br />W O <br />IZ O IY <br />Q <br />0 <br />Z <br />0 <br />En <br />W <br />w <br />N <br />N <br />LO <br />CV <br />CV <br />m <br />� <br />� <br />z <br />o <br />W <br />O <br />Z <br />m <br />p <br />p <br />O <br />i <br />r <br />O� <br />LL <br />W W <br />> <br />z <br />�2i Q <br />a <br />METAL WALL CAP 12 ga. HANGER WIRE ~ O� <br />W/ BACKDRAFT DAMPER I—' W 0 <br />AND BIRD SCREEN Z U <br />ANGER WIRE OR STRAP O W <br />5'-0" MAX DISTANCE _CL U) <br />BETWEEN SUPPORTS. <br />MAX. SAG 10" PER FOOT METAL SUPPOR f — (n <br />OF SUPPORT SPACING. STRAP MIN. 1\2" WIDE LL <br />RIGID AIR DUCT: <br />ON <br />UL-181 CLASS 1 SPIN -IN W/ 1-1/2" GALV.STEEL BAND <br />BACK DRAFT <br />MANUAL DAMPER DAMPER ® <br />INSULATED MIN. R-6 CLAMP TO MATCH DUCT 7 N <br />SEE "METHODS OF DIAMETER FAN L >- O Of <br />HANGING DUCTS" N <br />FOR REQUIREMENTS OF/H <br />HOUSING W M <br />INSULATED MIN. R-6 <br />FLEXIBLE DUCT W W <br />W <br />UL-181 CLASS 1 Q WALLNN / ® W <br />FLASHING AND � OPENING ` CEILING o U N <br />SEAL WALL CAP <br />AIR DIFFUSER <br />CEILING w REMOVABLE GRILL Q <br />w W W <br />INSTALL STAINLESS STEEL DUCT NOTE: f <br />CLAMPS ON BOTH INNER AND OUTER ALL STRAP SHALL BE A Z <br />JACKETS. SEAL INNER JACKET AIR z <br />TIGHT WITH MASTIC. NYLON DRAWBANDS MINIMUM OF 1-1/2", 26 EXHAUST FAN DETAIL <br />MAY BE USED IN NON PLENUM AREAS, GA. GALVINIZED STEEL. <br />HANGER WIRE SHALL BE IN SUSPENDED CEILING <br />FLEXIBLE DUCT DETAIL A MINIMUM OF 22 GA. SCALE: NT <br />ARKAY ENGINEERING INC. <br />RICHARD L. KIDDEY P.E. <br />FLORIDA LICENSE NUMBER 37296 <br />RENOVATION <br />AREA <br />3588 SQ. FT. <br />SHEET <br />M2 <br />ARKAY # 19859 <br />