Laserfiche WebLink
FLOOR FINISH LEGEND: CARPET INSTALLER: NOTE 6.30.14 WELLS FARGO INSTALLATION UPDATES <br />PORCELAIN TILE <br />CARPET TILE <br />33% AHHLAR PATTERN <br />50% VERTICAL ASHLAR <br />ADJUST DIRECTION EVERY <br />THIRD ROW <br />4 <br />n <br />� <br />4 4 <br />� <br />Q 4 <br />VINYL COMPOSITION <br />TILE (VCT) <br />r SEALED CONCRETE <br />r r r <br />r r r <br />r r r <br />r r r <br />r r r <br />r r r <br />err <br />rrr <br />-T FINISH FLOOR <br />TRANSITION STRIP <br />NEW VCT AND BASE. <br />MANNINGTON - TOUCHSTONE <br />PREMIUM TILE. <br />COLOR: WHEAT 9123 12"x12"; <br />INSTALLED: QUARTER TURNED <br />NTENDS TO KEEP <br />WINDOW COVERINGS. <br />JTIRE INTERIOR TO <br />:XISTING. <br />1 FINISH PLAN <br />F1.0 SCALE: 1/4" = 1'-0" 6mimmom"'' <br />0 2 <br />4 8 F <br />INTERIOR WOOD DOORS: <br />MATCH EXISTING OR AS DIRECTED BY PjM/CLIENT. <br />WINDOW SHADES (WS) <br />WINDOW SHADES ARE EXISTING. CLEAN AND/OR REPAIR AS <br />NECESSARY OR AS DIRECTED BY CLIENT. <br />THRESHOLD REDUCER AS REQ'D. <br />WOOD PLANK FOLLOW ADA REQUIREMENTS <br />FLOORING FOR THRESHOLD DESIGN AND <br />INSTALLATION. <br />VCT FLOORING <br />ML 11 'z 7777 ZZZZZZ2 T.O. SLAB <br />• <br />4 •_ ., <br />WD FLOORING/VCT TRANSITION <br />SCALE: 1 /2" = 1'-0" <br />GENERAL NOTES: NOT ALL NOTES APPLY <br />1, ALL FLOORING MATERIALS TRANSITION IN MIDDLE OF DOORWAY UNLESS <br />NOTED OTHERWISE. <br />2. ACCESS PANELS, VISIBLE COVERS OR ENCASEMENTS ETC. SHALL BE <br />PAINTED TO MATCH ADJACENT SURFACES. <br />3. FLOAT FLOOR SLAB AT TRANSITION AREA OF FLOOR FINISHES OF VARYING <br />THICKNESS A MINIMUM OF 2'-0" OR TO A ACHIEVE A MAXIMUM SLOPE OF <br />1:20 (WHICHEVER IS GREATER) TO ACHIEVE A UNIFORM AND FLUSH <br />TRANSITION BETWEEN FINAL FINISHED SURFACES. ALL TRANSITIONS SHALL <br />BE ADA COMPLIANT. <br />4. REFER TO SPECIFICATIONS FOR WINDOW SHADES (WS) INFORMATION. SEE <br />FINISH PLAN FOR LOCATIONS. <br />5. PREPARE WALL SURFACE(S) SCHEDULED TO RECEIVE OWNER INSTALLED <br />MURAL. TAPE, BED AND SAND SMOOTH FOR LEVEL 5 FINISH. WHITE <br />SEMI -GLOSS BENJAMIN MOORE AURA PAINT. NO PRIMER REQUIRED. ALLOW <br />PAINT TO CURE FOR FOUR DAYS BEFORE APPLYING MURAL. <br />6. REFER TO REFLECTED CEILING PLAN FOR CEILING FINISH. <br />7. PARTITION AND PAINTED CEILING FINISH TRANSITIONS/TERMINATIONS TO <br />OCCUR AT INSIDE CORNER, UNLESS NOTED OTHERWISE. <br />8. SCORE VINYL BASE AT ALL OUTSIDE CORNERS. <br />9. LOCATE POWER AND LOW VOLTAGE WALL OUTLETS SO AS TO MINIMIZE <br />VISIBILITY. <br />WELLS FARGO <br />ADVISORS <br />ZEPHYRHILLS <br />RELOCATION <br />5328 Sth STREET <br />ZEPHYRHILLS, FL 33542 <br />A ITECTU , ,DESIGN : L (RATIVE <br />945 N. PENNSYLVANIA AVE <br />WINTER PARK, FL 32789 <br />OFFICE: (407) 629-1188 <br />FAX: (407) 388-1220 <br />WWW. ADCINTERNATIONAL.NET <br />CLIENT ISSUE DATES <br />NO. <br />DESCRIPTION <br />DATE <br />1 <br />TEST FIT <br />09/02/14 <br />2 <br />50% REVIEW SET <br />11/05/14 <br />3 <br />95% REVIEW SET <br />11/12/14 <br />4 <br />100% CD/B.I.S. <br />11/25/14 <br />5 <br />100% CD/P.I.S. <br />01/15/15 <br />JAN 15 2015 <br />Albert J Cooper III AA-00013t1 STATE #AR-0010460 <br />REVISIONS <br />DATE ISSUEDi 09/02/14 <br />REVIEWED BYi AC <br />DRAWN BYi AC <br />DESIGNED BYi AC <br />WELLS FARGO BE#: <br />108880 <br />SHEET TITLE <br />FINISH PLAN <br />SHEET NUMBER <br />F1m0 <br />ADC PROJECT NUMBERi 14303 <br />