Laserfiche WebLink
LEGEND <br />DEMO <br />I I <br />I I <br />L----------- J <br />DEMO FLOOR PLAN <br />GENERAL DEMOLITION NOTES: <br />1 REMOVE EXISTING RECEPTACLES, TELEPHONES, SWITCHES, <br />AND ANY ELECTRICAL DEVICES IN WALLS TO BE DEMOLISHED. <br />RELOCATE THESE DEVICES AS INDICATED OR REQUIRED BY <br />THE DRAWINGS, ARCHITECT, OR OWNER REPRESENTATIVE. <br />PROVIDE ARCHITECT WITH AS -BUILT DRAWINGS OF FINAL <br />INSTALLATION FOR RECORD PURPOSES. CONTRACTOR IS <br />NOTIFIED THAT NOT ALL EXISTING DEVICES MAY HAVE BEEN <br />INDICATED ON THE DRAWINGS AND THAT SOME EXISTING <br />ELECTRICAL DEVICES MAY NOT HAVE BEEN SHOWN IN THEIR <br />ACTUAL LOCATION. CONTRACTOR IS REQUIRED TO VISIT SITE <br />AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS <br />PRIOR TO DETERMINING THE WORK THAT NEEDS TO BE <br />ACCOMPLISHED AS PART OF HIS/HER BID, <br />2 THE WORK SHALL INCLUDE THE FURNISHING OF ALL <br />MATERIALS, CUTTING, EXTENDING, CONNECTING, <br />REPAIRING, ADAPTING, AND OTHER COINCIDENTAL WORK <br />TOGETHER WITH SUCH TEMPORARY INSTALLATIONS AS <br />MAY BE NECESSARY TO SATISFY THE DEMOLITION <br />PROGRAM. APPROVAL SHALL BE SECURED FROM THE <br />LANDLORD/ARCHITECT PRIOR TO CUTTING/DRILLING ANY <br />STRUCTURAL SUPPORT, <br />3 ALL BUILDING CONSTRUCTION AFFECTED BY THE <br />REMOVAL, RELOCATION, INSTALLATION OF ANY PIECE OF <br />EQUIPMENT SHALL BE REPAIRED AND FINISHED AS <br />REQUIRED TO MATCH EXISTING CONDITION OR AS <br />DIRECTED BY THE ARCHITECTURAL DRAWINGS, <br />SPECIFICATIONS, OR OWNER'S REPRESENTATIVE. <br />4 WHEN ELECTRICAL DEVICES ARE PRESENT IN <br />PARTITIONS OR CEILINGS TO BE REMOVED, THE <br />ELECTRICAL CONTRACTOR SHALL DISCONNECT <br />THEM UP TO THE NEXT OUTLET TO REMAIN OR BACK <br />TO PANEL THE BOARD. IF EXISTING TO REMAIN <br />OUTLETS ARE FED THROUGH DEMOLISHED <br />PARTITIONS OR CEILINGS, THE CIRCUIT SHALL BE <br />REARRANGED TO MAINTAIN CIRCUIT CONTINUITY. <br />WIRE SHALL BE REMOVED BACK TO SOURCE FROM <br />INACCESSIBLE RACEWAYS NOT REUSED, INSTALL <br />BLANK PLATES ON FLUSH OUTLETS NOT REUSED. <br />PLATE COLOR SHALL MATCH ADJACENT SURFACE <br />AS NEAR AS POSSIBLE IN FINISHED AREAS. <br />5 ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM <br />STRUCTURE AS NECESSARY. OTHER ELECTRICAL <br />ITEMS ASSOCIATED WITH THIS WORK SHALL BE <br />REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO <br />CONTINUE IN SERVICE. <br />6 CONTRACTOR SHALL DEMOLISH ANY INTERIOR FINISHES <br />TO COMPLETE THE NECESSARY AND PROPOSED WORK <br />AS DIRECTED BY THE ARCHITECTURAL DRAWINGS, <br />INTERIOR DESIGN DRAWINGS, SPECIFICATIONS, OR BY <br />OWNER REPRESENTATIVES. <br />7 EXISTING FIXTURES, EQUIPMENT, AND ALL DEBRIS <br />WHICH ARE REQUIRED TO BE REMOVED SHALL BE <br />REMOVED BY THE CONTRACTOR. CONTRACTOR TO <br />COORDINATE WITH OWNER REPRESENTATIVES PRIOR <br />TO REMOVAL OF SUCH. <br />8 ALL ELECTRICAL AND PLUMBING LINES WHICH REQUIRE <br />REMOVAL OR ALTERATION ARE TO BE DONE SO BY THE <br />CONTRACTOR. LINES TO BE CAPPED AND PREPARED <br />FOR REMOVAL OR RE-ROUTING AS SPECIFIED. <br />9 REMOVE ALL UTILITIES IN DEMOLITION AREAS AND <br />CONSTRUCTION AREAS IN A MANNER, AND IN THE TIME, <br />SATISFACTORY TO THE UTILITY COMPANY. IF UTILITY <br />COMPANY DESIRES TO EFFECT THE REMOVAL OF THE <br />MATERIALS, THEY SHALL BE PERMITTED TO DO SO. <br />10 COVER ITEMS AS SPECIFIED BY OWNER/OWNER <br />REPRESENTATIVE TO PROTECT FROM DUST AND <br />DEBRIS. <br />11 SALVAGED MATERIALS SHALL BE REMOVED, CLEANED, <br />AND PREPARED FOR RE -INSTALLATION. OWNER <br />MAINTAINS OWNERSHIP OF ALL MATERIALS UNLESS <br />OTHERWISE SPECIFIED. <br />12 WHERE EXISTING WALLS, CEILINGS, AND FIXTURES HAVE <br />BEEN REMOVED, AREAS SHALL BE PATCHED TO MATCH <br />EXISTING FINISHES, OR FINISHES TO BE ADDED AS PER <br />PLANS, INTERIOR DESIGNER, OR AS PER OWNER. <br />13 N/A <br />14 WHERE EXISTING WORK IS DAMAGED IN THE EXECUTION <br />OF THIS CONTRACT, OR WHERE OPENINGS ARE LEFT <br />DUE TO THE REMOVAL OF PIPES, EQUIPMENT OR <br />APPARATUS, THE SAME SHALL BE REPAIRED OR <br />CLOSED UP TO CORRESPOND IN MATERIAL, QUALITY, <br />SHAPE AND FINISH WITH THAT OF SIMILAR AND <br />ADJOINING WORK, UNLESS OTHERWISE CALLED FOR. <br />WHERE DAMAGE IS IRREPARABLE, NEW ITEMS OR <br />EQUIPMENT SHALL BE PROVIDED. CONTRACTOR <br />SHALL PROVIDE ALL NECESSARY WATERPROOFING, <br />FIRE STOPPING AND SEALING OF PENETRATIONS LEFT <br />FROM REMOVED EQUIPMENT OR PRODUCED BY THIS <br />WORK. <br />15 INTERRUPTION OF EXISTING SERVICES AND/OR <br />OPERATION OF FACILITIES SHALL BE KEPT TO A <br />MINIMUM. CONTRACTOR SHALL FURNISH ALL <br />MATERIALS REQUIRED WHENEVER TEMPORARY <br />CONNECTIONS ARE NECESSARY TO MAINTAIN <br />CONTINUITY OF SERVICE. INTERRUPTION OF <br />EXISTING SERVICES, THE INSTALLATION OF <br />TEMPORARY FACILITIES, AND THE WORK OF MAKING <br />FINAL CONNECTIONS TO THE NEW WORK SHALL BE <br />DONE ONLY AT SUCH TIMES PERMITTED AND <br />SCHEDULED IN ADVANCE BY THE ARCHITECT/OWNER <br />WITHOUT ADDITIONAL COST. CARE MUST BE USED IN <br />REMOVING SERVICES TO AREAS BEING DEMOLISHED <br />SO THAT SERVICES TO OTHER AREAS WHICH MIGHT <br />BE SERVED THROUGH THESE AREAS WILL NOT BE <br />INTERRUPTED. <br />16 WHERE DEMOLITION WORK REQUIRES TEMPORARY <br />INTERRUPTION OF ELECTRICAL, TELEPHONE, TV, ALARM <br />OR COMMUNICATION SERVICES, RESPECTIVE UTILITIES <br />AND/OR COMPANY REPRESENTATIVES SHALL BE <br />NOTIFIED AS NECESSARY, AND ALL WORK DONE SHALL <br />BE UNDER SUPERVISION AND THEIR ESTABLISHED <br />STANDARDS. <br />17 ALL LIGHTING FIXTURES, RECEPTACLES, SWITCHES, <br />WIRING DEVICES, SPECIAL OUTLETS, TELEPHONE <br />CABLES, TV CABLES, MISCELLANEOUS SYSTEM WIRING, <br />POWER CONDUCTORS, CONDUITS, ELECTRICAL BOXES, <br />RACEWAYS AND ANY OTHER ELECTRICAL SYSTEM <br />COMPONENTS LOCATED IN THE AREAS SHOWN AS <br />BEING DEMOLISHED OR NOT USED AFTER WORK IS <br />COMPLETED SHALL BE REMOVED UNLESS OTHERWISE <br />NOTED AS EXISTING TO REMAIN OR BE RELOCATED. <br />CONDUITS RUNNING IN SLAB AT FINISHED AREAS SHALL <br />BE CUT FLUSH, PLUGGED AND ABANDONED AFTER <br />CONDUCTORS ARE REMOVED. NO WIRING SHALL BE <br />LEFT ABANDONED AFTER WORK IS COMPLETED. <br />18 ALL DEMOLITION, RENOVATION, AND <br />CONSTRUCTION TO COMPLY WITH NFPA 241. <br />19 DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. <br />WELLS FARGO <br />ADVISORS <br />ZEPHYRHILLS <br />RELOCATION <br />5326 Sth STREET <br />ZEPHYRHILLS, FL 33542 <br />A ITECTDDESIGN CRATIVE <br />945 N. PENNSYLVANIA AVE <br />WINTER PARK, FL 32789 <br />OFFICE: (407) 629-1188 <br />FAX: (407) 388-1220 <br />WWW. ADCINTERNATIONAL.NET <br />CLIENT ISSUE DATES <br />NO. <br />JAN 15 2015 <br />Albert J Cooper III AA-CO01315 STATE #AR-0010460 <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUED 09/02/14 <br />REVIEWED BYi AC <br />DRAWN BYi AC <br />DESIGNED BYi AC <br />WELLS FARGO BE#: <br />108880 <br />SHEET TITLE <br />DEMO FLOOR PLAN <br />SHEET NUMBER <br />A1m02 <br />ADC PROJECT NUMBERi 14303 <br />DESCRIPTION <br />DATE <br />1 <br />TEST FIT <br />09/02/14 <br />2 <br />60% REVIEW SET <br />11/06/14 <br />3 <br />96% REVIEW SET <br />11/12/14 <br />4 <br />100% CD/B.I.S. <br />11/26/14 <br />6 <br />100% CD/P.I.S. <br />01/16/16 <br />SCALE: 1/4" = 1'-0" 7 7 4 mmmommi <br />8 FT <br />