My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5440 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5440 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:49:34 PM
Creation date
2/18/2025 3:30:29 PM
Metadata
Fields
Template:
Building Plans
Street #
5440
Location
Gall Blvd
Contractor
Austin Construction Group
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 1 MECHANICAL GENERAL NOTES <br />3 1 CODE CRITERIA <br />0 <br />MECHANICAL SCHEDULE <br />1. <br />PLANS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE MECHANICAL <br />NOTE: <br />SYSTEM COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL <br />ALL CODES SHALL COMPLY WITH THE FLORIDA STATUES 69A-3.012 AND THE STATE <br />FIRE MARSHALL'S RULE. THIS LIST IS NOT INCLUSIVE OF ALL CODES AND <br />ROOFTOP UNIT SCHEDULE <br />LOCATION OF THESE COMPONENTS SHALL BE DETERMINED IN THE FIELD IN <br />STANDARDS THAT MAY OR MAY NOT APPLY TO THIS PROJECT. <br />COORDINATION WITH THE WORK OF OTHER TRADES. THE USE OF MANUFACTURER'S <br />EVAPORATOR SECTION <br />HEATER <br />ELECTRIC <br />UNIT <br />UNIT <br />SHOP DRAWINGS AND SIMILAR CERTIFIED DATA. PLANS SHALL NOT BE SCALED. <br />- FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) - ALL SECTIONS <br />PLAN <br />MANUF. <br />MODEL # <br />TOTAL <br />SENS. <br />WEIGHT <br />EFF. <br />NOTES <br />- FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) ENERGY <br />MARK <br />SUPPLY <br />OSA CFM <br />E.A.T <br />L.A.T <br />COOLING <br />COOLING <br />HEATER <br />ELECTRIC <br />(LBS.) <br />(IEER) <br />2. <br />WHERE THE CEILING SPACE IS USED AS A RETURN AIR PLENUM, ALL ELECTRICAL <br />CONSERVATION SOFTWARE: ENERGY GAUGE SUMMIT VERSION 8.00 <br />CFM <br />(DB/WB) <br />(DB/WB) <br />(BTUH) <br />(BTUH) <br />(KW) <br />V/• <br />WORK IN THAT SPACE SHALL COMPLY WITH THE REQUIREMENTS OF NFPA-70 (NEC) <br />FLORIDA FIRE PREVENTION CODE 2023 <br />RTU-1 <br />EXISTING <br />EXISTING <br />+/- 10,000 <br />800 <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />208/3 <br />EXISTING <br />EXISTING <br />1 <br />AS IT RELATES TO THAT APPLICATION. EXPOSED WIRE SHALL BE PLENUM RATED. THE <br />NATIONAL FIRE PROTECTION ASSOCIATION (NFPA): <br />MUA-2 <br />CAPTIVEAIRE <br />Al-15D-MPU <br />1,980 <br />- <br />91/77 <br />75/69.1 <br />60,000 <br />33,500 <br />- <br />- <br />1088 <br />- <br />2 <br />USE OF PVC WITHIN THE PLENUM IS STRICTLY PROHIBITED. COORDINATE WITH OTHER <br />- NFPA-70 (2020) NATIONAL ELECTRICAL CODE <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />INSTALLERS TO PREVENT THE INSTALLATION OF PROHIBITED MATERIALS. <br />- NFPA-72 (2019) NATIONAL FIRE ALARM CODE <br />NOTES: <br />- NFPA-90A (2021) STANDARD FOR THE INSTALLATION OF <br />1. EXISTING ROOFTOP UNIT TO REMAIN, FIELD VERIFY EXISTING CONDITIONS <br />AIR-CONDITIONING AND VENTILATING SYSTEMS <br />2. COORDINATE WITH CAPTIVEAIRE SHOP DRAWINGS FOR INSTALLATION INFORMATION AND DETAILS <br />3. <br />DUCTWORK, AIR DEVICES AND OTHER ITEMS OF THE AIR DISTRIBUTION SYSTEM SHALL <br />_ NFPA-90B (2021) STANDARD FOR THE INSTALLATION OF WARM AIR <br />BE SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE AND NOT FROM THE <br />HEATING AND AIR CONDITION SYSTEMS <br />CEILING OR CEILING SUSPENSION SYSTEM. COORDINATE LOCATION OF AIR DEVICES <br />WITH ELECTRICAL, ENGINEER, FIRE PROTECTION AND PLUMBING WORK. AIR DEVICES <br />AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING <br />FAN SCHEDULE <br />ENGINEERS, INC (ASHRAE): <br />SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE FROM AT LEAST TWO POINTS. <br />- ASHRAE GUIDELINES 4-2019 - PREPARATION OF OPERATING AND <br />MARK <br />AREA SERVED <br />TYPE <br />CFM <br />HP <br />FLA <br />R.P.M. <br />VOLTS/PH <br />SONES <br />MANUFACTURER & MODEL NO. <br />NOTES <br />MAINTENANCE DOCUMENTATION FOR BUILDING SYSTEMS <br />KEF-2 <br />KITCHEN <br />ROOF TOP <br />2,200 <br />2.0 <br />8.3 <br />1 151 <br />208 / 3 <br />13.7 <br />CAPTIVEAIRE DU 180HFA <br />1 <br />4. <br />ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE <br />- ASHRAE STANDARD 62.1-2019 AND APPROVED ADDENDA - VENTILATION <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />LATEST EDITION OF "SMACNA" DUCT CONSTRUCTION STANDARDS AND COMPLY <br />FOR ACCEPTABLE INDOOR AIR QUALITY <br />WITH THE LATEST "NFPA" 90A REQUIREMENTS. ALL DUCTWORK SHALL BE LEAK TESTED <br />- ASHRAE STANDARD 126-2020 - METHOD OF TESTING HVAC AIR DUCTS <br />NOTES: <br />IN ACCORDANCE WITH SMACNA AND ASHRAE STANDARDS, AND BE COMPLETED <br />- ASHRAE STANDARD 180-2018 - STANDARD PRACTICE FOR INSPECTION <br />1. COORDINATE WITH CAPTIVEAIRE SHOP DRAWINGS FOR INSTALLATION INFORMATION AND DETAILS <br />AND MAINTENANCE OF COMMERCIAL BUILDING HVAC SYSTEMS <br />BY THE TEST AND BALANCE COMPANY, DUCTS WITH A LEAKAGE RATE MORE THAN <br />2% WILL BE REJECTED. <br />AIR DEVICE SCHEDULE <br />FABRICATED DUCTWORK TO THE FOLLOWING DUCT PRESSURE CLASS: <br />MARK <br />DESCRIPTION <br />FACE SIZE <br />NECK <br />MATERIAL <br />MANUFACTURER & MODEL NO. <br />NOTES <br />DUCT PRESSURE CLASS OPERATING PRESSURE <br />4 <br />ABBREVIATIONS <br />A <br />LOUVERED FACE RETURN GRILLE <br />24"x24" <br />SEE PLAN <br />ALUMINUM <br />VENT -AIR FILTER GRILLE <br />1,2 <br />2" W.G. UP TO 2" W.G. <br />B <br />LOUVERED FACE SUPPLY DIFFUSER <br />24' x 24" <br />SEE PLAN <br />ALUMINUM <br />VENT 1-AIR-HT3D081 <br />1,2 <br />1" W.G. OVER z" UP TO 1" W.G. <br />_ <br />- <br />- <br />- <br />- <br />- <br />SYMBOL DESCRIPTION <br />NOTES: <br />DUCTWORK SHALL BE SEALED TO: <br />AFF ABOVE FINISHED FLOOR <br />1. COORDINATE SURFACE FINISHES WITH OWNER. <br />AHU AIR HANDLING UNIT <br />2. SUPPLY COMPLETE FACTORY INSTALLED 1 /2" THICK FOIL BACKED INSULATION. <br />APPLICABLE DUCT PRESSURE CLASS SEAL CLASS <br />2" W.G. AND BELOW A <br />BTU BRITISH THERMAL UNIT <br />BLDG BUILDING <br />5. <br />ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. <br />CFM CUBIC FEET PER MINUTE <br />FLEX DUCT <br />OUTSIDE AIR CALCULATIONS <br />DIA DIAMETER <br />6. <br />SUPPLY AND EXHAUST AIR DUCTWORK SHALL BE DUCT BOARD (MINIMUM INSTALLED <br />ELEV ELEVATION <br />OCC. FACTOR <br />AHRAE 62 VALUES PER <br />SPACE <br />SPACE <br />SCHEDULE <br />R = 6.0). SEAL ALL DUCT JOINTS WITH HARDCASE. DUCT INSULATION SHALL BE <br />) <br />EQUIP EQUIPMENT <br />CLASSIFICATION <br />OCCUPANCY/ 1000 <br />TABLE 6-1 <br />AREA (SQFT) <br />LOAD <br />(PERSONS) <br />OUTDOOR AIR REQUIRED <br />(CFM) <br />OUTDOOR AIR <br />SUPPLIED(CFM) <br />CFM <br />FLEX SIZE <br />LABELED AND MARKED AT REQUIRED INTERVALS PER THE FLORIDA BUILDING CODE. <br />EA EXHAUST AIR <br />SQFT. (PERSONS) <br />Rp <br />Ra <br />Az <br />Pz <br />0 - 50 <br />• ••• <br />EF EXHAUST FAN <br />51 - 100 <br />• ••• <br />KITCHEN <br />20 <br />7.5 <br />0.12 <br />2800 <br />56 <br />756 <br />800 <br />7. <br />ALL VOLUME DAMPERS SHALL BE OPPOSED BLADE TYPE. PROVIDE A ONE FOOT <br />FLEX FLEXIBLE <br />101 - 200 <br />• ••• <br />LONG PLASTIC STRIP OF MATERIAL FROM ALL DAMPER HANDLES TO ASSIST TEST AND <br />GALV GALVANIZED <br />201 - 400 <br />• • •» <br />BALANCE AGENCY IN THE IDENTIFYING ALL DAMPERS. IN AREAS WHERE THE FINAL <br />RA RETURN AIR <br />- 600 <br />• • ••• <br />TOTAL <br />2800 <br />56 <br />756 <br />800 <br />DAMPER INSTALLATION PROHIBITS ACCESS FOR TEST AND BALANCE, PROVIDE <br />SA SUPPLY AIR <br />NOTE: <br />601 <br />01 - 900 <br />• • ••• <br />POWER BALANCING DAMPERS AS MANUFACTURED REQUIRED FOR A COMPLETE <br />T THERMOSTAT <br />REQUIRED OUTDOOR VENTILATION AIR VALUES TAKEN FORM ASHRAE 62, TABLE 6-1. <br />901 - 1,300 <br />• • •» <br />TYP TYPICAL <br />VENTILATION BREATHING ZONE FORMULA: Vbz = Rp * Pz + Ra * Az <br />AND OPERATIONAL SYSTEM. (PROVIDE MANUAL REMOTE CABLE CONTROLS EQUAL <br />VD VOLUME DAMPER <br />Pz = OCCUPANCY FACTOR * SPACE AREA <br />TO YOUNG REGULATOR MODEL 830ACC/270-896. ACCESS TO END OF CABLE TO BE <br />FLUSH IN CEILING NEATLY CONCEALED WITH THREADED CAP. PAINT CAP TO MATCH <br />NOTE: <br />AREA DOES NOT INCLUDE RESTROOMS AND SHOWER ROOMS. SHOP AREA NOTE: SHOP AREA WILL BE <br />CEILING COLOR. REMOVE MATERIAL FROM EXPOSED DUCT DAMPERS AFTER <br />NATURALLY VENTILATED DURING WORK HOURS. SEE SHEET M1.0 FOR CALCULATION & NOTES. <br />SUBSTANTIAL COMPLETION). <br />8. <br />PROVIDE CONICAL SPIN -IN FITTINGS AT ALL CONNECTIONS OF ROUND SHEET METAL <br />OR FLEXIBLE SUPPLY AIR DUCTS TO RIGID RECTANGULAR DUCT. <br />5 <br />PLUMBING LEGEND & SYMBOLS <br />9. <br />ALL PIPING AND /OR DUCTWORK MUST BE INSTALLED b" AWAY FROM ANY FIRE <br />RATED WALL. <br />10. <br />FLEXIBLE DUCTS SHALL BE FACTORY INSULATED WITH 3/4" THICK GLASS FIBER AND <br />"THERMAFLEX" <br />SUPPLY DIFFUSER. (4-WAY) <br />INCLUDE A VINYL VAPOR JACKET AND HELIX STEEL WIRE. TYPE M-KE <br />OR APPROVED EQUAL. FLEXIBLE DUCT SHALL BE ATTACHED WITH "THERMAFLEX" <br />RETURN OR OUTDOOR AIR GRILLE <br />WRAP LOCK SERIES 0902 CLAMPS. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE <br />6-0". <br />EXHAUST GRILLE <br />11. <br />ALL WALL MOUNTED TEMPERATURE AND HUMIDITY SENSORS SHALL BE INSTALLED AT <br />RECTANGULAR DUCTWORK WITH TAKE -OFF, <br />A CENTER LINE ELEVATION OF 4'-0" ABOVE FINISHED FLOOR UNLESS OTHERWISE <br />BALANCING DAMPER AND INSULATED FLEXIBLE <br />NOTED ON DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE <br />A B ROUND DUCT. SAME SIZE AS DIFFUSER INLET UNLESS <br />NOTED OTHERWISE. FIRST DIMENSION IS THAT OF SIDE <br />COORDINATED WITH THE OTHER TRADES FOR A NEAT APPEARANCE. FINAL <br />SHOWN. <br />LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER <br />OR THE OWNER IN THE FIELD. WHEN INSTALLED ON EXTERIOR WALLS, PROVIDE AN <br />A ROUND DUCTWORK. <br />INSULATED SUB -BASE. <br />MANUEL DAMPER <br />12. <br />RETAIN THE SERVICES OF A NEBB AND/OR AABC CERTIFIED TEST AND BALANCE <br />AGENCY TO PERFORM FINAL TESTING AND BALANCING OF ALL HVAC SYSTEMS. <br />RECORD ALL DATA ON STANDARD "AABC" OR OTHER APPROVED FORMS, AND <br />FIRE DAMPER WITH ACCESS PANEL, <br />SUBMIT TO THE ENGINEER FOR REVIEW. <br />13. <br />ALL NEW DUCTWORK SHALL BE STORED IN CLEAN AREAS. PROTECT ALL DUCTWORK <br />EXISTING DUCTWORK TO BE REMOVED (DASHED LINETYPE) <br />FROM DUST AND DEBRIS WHILE IT IS STORED ON SITE. WHILE UNDER CONSTRUCTION, <br />ALL INSTALLED DUCTWORK SHALL BE TEMPORARILY SEALED WITH VISQUEEN PRIOR <br />DUCT MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY <br />ELECTRICAL CONTRACTOR AND INSTALLED IN DUCT BY <br />TO TEST AND BALANCE IN ORDER TO LIMIT ACCUMULATION OF CONSTRUCTION <br />MECHANICAL CONTRACTOR. REFER TO SPECIFICATIONS FOR <br />DUST INSIDE DUCTWORK SYSTEM. IF EITHER OF THESE PROCEDURES IS NOT <br />CONTROL REQUIREMENTS. <br />CONDUCTED, THE ENTIRE ASSOCIATED DUCTWORK SYSTEM AND MECHANICAL <br />AIR DEVICE TAG <br />EQUIPMENT SHALL BE CLEANED TO THE OWNER'S SATISFACTION. <br />A-100 MARK-CFM <br />SIDEWALL TRANSFER GRILLE <br />2 <br />NOTES: <br />�j <br />IXII SIDEWALL SUPPLY REGISTER <br />1. <br />THE NOTES SHOWN ON THIS SHEET APPLY TO GENERAL CONDITIONS OF HEATING, <br />�-�y <br />VENTILATING AND AIR CONDITIONING WORK REQUIRED FOR THIS PROJECT. <br />TS WALL MOUNTED DDC TEMPERATURE SENSOR <br />MOUNT 5-0" ABOVE FINISHED FLOOR. <br />2. <br />SPECIFICATIONS,PROJECT MANUALS AND DRAWINGS, REFER TO THIS SHEET FOR <br />APPLICABLE REFERENCES. <br />O WALL MOUNTED THERMOSTAT <br />MOUNT 48" ABOVE FINISHED FLOOR. <br />3. THE DESIGN DRAWINGS OF ALL CATEGORIES AND TRADES (ARCHITECTURAL, <br />STRUCTURAL, PLUMBING, MECHANICAL, HEATING, VENTILATING AND AIR <br />CONDITIONING, AND ELECTRICAL) AND ALL SPECIFICATIONS AND SHOP DRAWINGS <br />MUST BE COORDINATED AND VIEWED IN CONNECTION AND CONJUNCTION WITH <br />EACH OTHER TO INSURE THE PROPER LOCATION OF ALL DEVICES AND EQUIPMENT. <br />MAKE PARTICULAR NOTE OF LOCATIONS AND DIMENSIONS SHOWN ON THE FLOOR <br />PLANS AND ELEVATIONS. <br />4. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS <br />COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE <br />FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN <br />ACCORDANCE WITH SECTION 110.8.4.4 OF THE BUILDING CODE AND 633 FLORIDA <br />STATUTES. <br />^Gap <br />ENGINEERING & CONSTRUCTION <br />AUSTIN CONSTRUCTION GROUP <br />2706 STALLONE DRIVE <br />TAMPA, FLORIDA 33605 <br />(813) 293-8883 <br />FLORIDA PE 48917 192169 - <br />CGC1521407 - CUC1224196 - <br />CFC 1430334 - FPC 15-4000052 <br />PROJECT INFORMATION: <br />CLIENT: <br />RICHARD KAZBOUR <br />PROJECT NAME: <br />HUNGRY HOWIES RESTAURANT <br />ADDITION <br />PROJECT LOCATION: <br />5440 GALL BLVD <br />ZEPHYRHILLS, FL 33542 <br />SEAL: <br />GOATS',I�����i.r <br />s r <br />• •sosr^ttRL <br />`� ""flat 1 <br />FL COA NO. 30178 <br />ENGINEER OF RECORD <br />FL LICENSE NO. <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE <br />PLANS AND SPECIFICATIONS COMPLY WITH THE <br />APPLICABLE MINIMUM BUILDING CODES <br />REVISIONS: <br />NO. <br />DATE <br />COMMENTS <br />SHEET TITLE: <br />MECHANICAL <br />NOTES & SCHEDULE <br />SHEET INFORMATION: <br />DRAWN: A.C. <br />SHEET NO. <br />DATE: 7/22/2024 <br />CHECKED: K.C. <br />DATE: 7/22/2024 <br />moo I <br />PROJECT NUMBER: <br />SCALE: <br />INDEX: <br />AS SHOWN <br />
The URL can be used to link to this page
Your browser does not support the video tag.