Laserfiche WebLink
1 1 LIFE SAFETY PLAN <br />SCALE:3/16''=1'-0" 1 2 1 CODE CLASSIFICATION AND REQUIREMENTS: <br />OCCUPANCY CLASSIFICATION <br />B - BUSINESS <br />CONSTRUCTION TYPE <br />II-B <br />BUILDING AREA <br />3,131 S.F. <br />AUTOMATIC SPRINKLER SYSTEM <br />NO <br />FIRE -RESISTANCE RATING FOR BLINDING <br />PRIMARY STRUCTURAL FRAME: 0 HRS <br />ELEMENTS (HRS) <br />NONBEARING WALL AND PARTITIONS <br />EXTERIOR: 0 HR <br />FIRE-RESISTANT SEPARATION (HRS) <br />0 HR REQUIRED <br />0 HR PROVIDED <br />MAXIMUM AREA OF EXTERIOR WALL <br />OPENINGS BASED ON FIRE SEPARATION <br />NO LIMIT <br />DISTANCE AND DEGREE OF OPENING <br />PROTECTION <br />OCCUPANT LOAD <br />12 OCCUPANTS, SEE TABLE <br />MINIMUM REQUIREMENT EGRESS WIDTH <br />REQUIRED = 17 * 0.2" = 3.4" <br />PROVIDED = 34'' * 4 = 136'' <br />MINIMUM REQUIREMENT OF EXISTS FOR <br />REQUIRED = 2 <br />EGRESS <br />PROVIDED = 4 <br />FIRE EXTINGUISHER <br />HAZARD OCCUPANCY INDUSTRIAL GENERAL <br />PURPOSE (ORDINARY HAZARD) <br />MINIMUM RATED SINGLE EXTINGUISHER: A,B,C - 10 <br />MAXIMUM FLOOR AREA FOR <br />FIRE PROTECTION SYSTEM <br />EXTINGUISHER: 11,250 SF <br />NUMBER OF EXTINGUISHERS PROVIDED = 5 <br />EXTINGUISHERS <br />MAXIMUM TRAVEL DISTANCE TO <br />EXTINGUISHER = > 75-0" <br />3 OCCUPANT LOAD CALCULATIONS: <br />OCCUPANT LOAD CALCULATIONS <br />TYPE <br />AREA / NO. <br />DESCRIPTION <br />COUNT <br />KITCHEN/PREP AREA <br />2,851 S.F. <br />200 SF PER PERSON <br />14.26 <br />BUSINESS/SERVING <br />280 <br />150 SF PER PERSON <br />1.87 <br />TOTAL <br />3,131 S.F. <br />17 <br />4 1 NOTES <br />- ALL EXIT CORRIDORS AND HALLWAYS ARE TO BE PROVIDED WITH A MINIMUM <br />OF 1-1/2" HOURS OF EMERGENCY LIGHTING. LIGHTING FACILITIES SHALL BE <br />ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN THE <br />AVERAGE OF 1 FT -CANDLE AND, AT ANY POINT, NOT LESS THAN 0.1 FOOT <br />CANDLE, MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. <br />REFERENCE SECTION 7.9.2 NFPA 101 (2021 EDITION) ALL EMERGENCY LIGHTS <br />AND EXIT SIGNS TO BE EQUIPPED WITH APPROVED BATTERY BACKUP <br />- FIRE EXTINGUISHERS SIZE, TYPE AND LOCATIONS TO MEET NFPA 10 (2022 ED.) <br />AND NFPA 30A (2021 ED.). <br />5 1 MEANS OF EGRESS REQUIREMENTS: <br />UN -SPRINKLED <br />PROVIDED <br />MAX. COMMON PATH OF TRAVEL <br />75-0" <br />22'-0" <br />MAX. DEAD END CORRIDOR <br />20'-0'' <br />N/A <br />MAX. TRAVEL DISTANCE TO EXIT <br />75-0" <br />27 4' <br />NUMBER OF EXITS PER STORY <br />N/A <br />N/A <br />MIN. EXIT SEPARATION <br />1 /2 DIAG. <br />DIST = 36-5" <br />41 2" <br />MIN. WIDTH OF EGRESS STAIRS <br />44'-0'' <br />N/A <br />NUMBER OF EXITS FOR OCCUPANT LOAD <br />2 <br />3 <br />EGRESS STAIR WIDTH/PERSON <br />0.3''/OCCUP <br />N/A <br />EGRESS COMPONENT WIDTH/PERSON <br />0.2" /OCCUP <br />< MIN. REQ'D <br />1 6 1 INTERIOR FINISH REQUIREMENTS: <br />l . FINISH REQUIREMENTS / OCCUPANCY: FBC TABLE 803.11 (UNSPRINKLED) <br />2. EXITS: CLASS -A, FLAME SPREAD 01-26; SMOKE <br />DEVELOPED 0-450 <br />3. EXITS ACCESS: CLASS-B, FLAME SPREAD 26-75; SMOKE <br />DEVELOPED 0-450 <br />4. OTHER SPACES: CLASS-C, FLAME SPREAD 76-200; SMOKE <br />DEVELOPED 0-450 <br />7 1 LIFE SAFETY LEGEND: <br />SYMBOL DESCRIPTION MOUNTING/REMARKS <br />FE 1 FIRE EXTINGUISHER WALL MOUNTED <br />TYPE A,B,C -10 <br />FE 2 FIRE EXTINGUISHER WALL MOUNTED <br />TYPE 1-A : K <br />MOUNTED ABOVE EXIT DOORS <br />EXIT EMERGENCY EXIT SIGN W/ 90 MIN. BACKUP (TYP.) <br />W/ LIGHT *UPGRADE AS REQUIRED* <br />E_X_l TI <br />EXIT SIGN CEILING MOUNTED W/ 90 MIN. <br />BACKUP (TYP.) <br />----- COMMON PATH OF TRAVEL <br />- - - - - - - MAX TRAVEL DISTANCE <br />POINT OF DECISION (COMMON PATH) <br />1 8 1 ACCESSIBLE EXTINGUISHER: <br />BRACKET MOUNTED <br />FIRE EXTINGUISHER <br />r\ <br />N <br />ACCESSIBLE EXTINGUISHER <br />NOTE: FIRE EXTINGUISHERS TO MEET OR EXCEED THE <br />LATEST NFPA 10 CODE. <br />o �s <br />ENGINEERING & CONSTRUCTION <br />AUSTIN CONSTRUCTION GROUP <br />2706 STALLONE DRIVE <br />TAMPA, FLORIDA 33605 <br />(813) 293-8883 <br />FLORIDA PE 48917 1 92169 - <br />CGC 1521407 - CUC 1224196 - <br />CFC 1430334 - FPC 15-4000052 <br />PROJECT INFORMATION: <br />CLIENT: <br />RICHARD KAZBOUR <br />PROJECT NAME: <br />HUNGRY HOWIES RESTAURANT <br />ADDITION <br />PROJECT LOCATION: <br />5440 GALL BLVD <br />ZEPHYRHILLS, FL 33542 <br />SEAL: <br />COATS,��`fffs <br />e • N <br />• e LU <br />Cr <br />Sl <br />FL COA NO. 30178 <br />ENGINEER OF RECORD <br />FL LICENSE NO. <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE <br />PLANS AND SPECIFICATIONS COMPLY WITH THE <br />APPLICABLE MINIMUM BUILDING CODES <br />REVISIONS: <br />NO. DATE COMMENTS <br />SHEET TITLE: <br />LIFE SAFETY <br />SHEET INFORMATION: <br />DRAWN: A.C. SHEET NO. <br />DATE: 7/22/2024 <br />CHECKED: K.C. Alol <br />DATE: 7/22/2024 <br />PROJECT NUMBER: <br />SCALE: INDEX: <br />AS SHOWN <br />