Laserfiche WebLink
1 I PROPOSED FLOOR PLAN SCALE: 1/4''= Y-0'' 1 2 1 PAGE KEY NOTES <br />MARK <br />NOTES <br />1 <br />SHADED AREA IS OUT OF SCOPE OF WORK. <br />APPROXIMATE LOCATION OF KITCHEN AND PREP AREA EQUIPMENT. <br />2 <br />CONTRACTOR TO COORDINATE EXACT LOCATION IN FIELD WITH OWNER <br />PRIOR TO INSTALLATION. <br />4"X4" HSS COLUMN FOR ROOF TOP LOAD. CONTRACTOR TO COORDINATE <br />3 <br />EXACT LOCATION IN FIELD WITH CAPTIEVAIRE TO VERIFY LOCATION IS UNDER <br />MUA-1 UNIT FOR NEW POINT LOAD ADDED TO ROOF. SEE STRUCTURAL PLAN <br />FOR DETAILS. <br />CONTRACTOR TO ADD OSHA COMPLIANT ROOF ACCESS LADDER WITH WITH <br />CAGED WALKTHROUGH. CONTRACTOR TO FIELD VERIFY EXACT LOCATION IN <br />4 <br />FIELD WITH OWNER AND HEIGHT OF BUILDING FOR LADDER HEIGHT <br />REQUIREMENTS. <br />CONTRACTOR TO PATCH EXISTING DAMAGED DRYWALL AT REAR OF <br />5 <br />BUILDING. CONTRACTOR TO COORDINATE SCOPE AND COST WITH OWNER <br />PRIOR TO FINALIZATION OF BID. <br />6 <br />WALK-IN COOLER SUPPLIED BY OWNER AND INSTALLED BY GENERAL <br />CONTRACTOR. CONTRACTOR TOO COORDINATE WITH OWNER. <br />7 <br />- <br />8 <br />- <br />9 <br />- <br />1 3 1 WALL LEGEND <#> <br />MARK <br />NOTES <br />1 <br />EXITING CMU WALLS WITH 3-5/8"STUD AND <br />5/8" GYP. BOARD. <br />1 <br />2 <br />EXISTING KNEE WALL <br />3 <br />EXISTING INTERIOR PARTITION WALL <br />4 <br />EXISTING WALK-IN FREEZER WALL <br />+ + + + + + + + + + <br />5 <br />NEW INTERIOR PARTITION WALL <br />3-5/8" 20GA. METAL STUDS 16'' O.C. W/ 5/8" <br />GYPSUM BOARD EACH SIDE <br />6 <br />NEW WALK-IN FREEZER WALL BYE„t> <br />MANUFACTURER. (RELOCATED UNIT)` <br />7 <br />NEW INTERIOR KNEE WALL - 38" MAX. HT. <br />3-5/8'' 20GA. METAL STUDS 16" O.C. W/ 5/8" <br />GYPSUM BOARD & FRP FULL HEIGHT <br />NOTE: <br />USE MOISTURE RESISTANCE BOARD IN WET AREAS <br />4 GENERAL FLOOR PLAN NOTES <br />1. GC MAY SUBSTITUTE ANY MANUFACTURER W/ AN EQUIVALENT. ALL SUBSTITUTIONS <br />TO BE APPROVED BY THE OWNER. <br />2. ALL DIMENSIONS AND CONDITIONS SHOULD BE FIELD VERIFIED. THE ENGINEER <br />SHOULD BE NOTIFIED OF ALL ERRORS, INCONSISTENCIES OR OTHER PROBLEMS <br />IMMEDIATELY UPON DISCOVERY AND BEFORE PROCEEDING WITH THE WORK. <br />3. DIMENSIONS ARE TAKEN FROM FACE OF STUD AND COLUMN CENTER LINES <br />UNLESS NOTED OTHERWISE. CLEAR DIMENSIONS ARE TO FINISHED FACE OF <br />CONSTRUCTION AND SHALL TAKE PRECEDENCE OVER ANY OTHER DIMENSIONS. <br />4. GYPSUM BOARD SHALL HAVE CONTROL JOINTS AT 30'-0'' O.C. <br />ENGINEERING & CONSTRUCTION <br />AUSTIN CONSTRUCTION GROUP <br />2706 STALLONE DRIVE <br />TAMPA, FLORIDA 33605 <br />(813) 293-8883 <br />FLORIDA PE 48917 192169 - <br />CGC1521407 - CUC1224196 - <br />CFC 1430334 - FPC 15-4000052 <br />PROJECT INFORMATION: <br />CLIENT: <br />RICHARD KAZBOUR <br />PROJECT NAME: <br />HUNGRY HOWIES RESTAURANT <br />ADDITION <br />PROJECT LOCATION: <br />5440 GALL BLVD <br />ZEPHYRHILLS, FL 33542 <br />SEAL: <br />G®ATS �• <br />.�� <br />�G 69 <br />_ <br />• 1p* • w <br />4 <br />• <br />s a V <br />a• !` <br />. U a• <br />sly„ �)% ••4s ea ea•• � 0� <br />FL COA NO. 30178 <br />ENGINEER OF RECORD <br />FL LICENSE NO. <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE <br />PLANS AND SPECIFICATIONS COMPLY WITH THE <br />APPLICABLE MINIMUM BUILDING CODES <br />REVISIONS: <br />NO. <br />DATE <br />COMMENTS <br />SHEET TITLE: <br />PROPOSED <br />FLOOR PLAN <br />SHEET INFORMATION: <br />DRAWN: A.C. <br />SHEET NO. <br />DATE: 7/22/2024 <br />CHECKED: K.C. <br />DATE: 7/22/2024 <br />A1.3 <br />PROJECT NUMBER: <br />SCALE: <br />INDEX: <br />AS SHOWN <br />