CONSTRUCTION PLAN
<br />1/8" = 1'-o"
<br />KEY NOTES
<br />1. AERIAL HANDICAP SIGN, SEE DETAIL 1/A2-1.
<br />2. VAN ACCESSIBLE PARKING SPACE, PROVIDE PROPER
<br />STRIPPING AND ADA SYMBOL PER ADAAG GUIDELINES.
<br />3. HANDICAP PARKING SPACE, PROVIDE PROPER STRIPPING AND
<br />ADA SYMBOL PER ADAAG GUIDELINES.
<br />4. ACCESS AISLE, STRIP AS REQUIRED BY ADAAG STANDARDS.
<br />5. VAN ACCESSIBLE SPACE VERTICAL SIGN, TO MEET ADAAG
<br />GUIDELINES, SEE 2/A2-1.
<br />6. ACCESSIBLE SPACE VERTICAL SIGN, TO MEET ADAAG
<br />GUIDELINES, SEE 2/A2-1.
<br />7. DETECTABLE WARNINGS PER FLORIDA BUILDING CODE, (MIN.
<br />36" DEEP).
<br />8. CURB RAMP MEETING ADAAG STANDARDS, SEE 3/A2-1.
<br />9. RE -PAVE ACCESSIBLE ROUTE ON EXTERIOR BUILDING SO
<br />THAT THE MAX. SLOPE IS 2% IN ALL DIRECTIONS.
<br />10. INSTALL NEW CLOSERS (TO ACHIEVE A MAXIMUM OPENING
<br />FORCE OF 5LBF) AND DOOR PULLS (HARDWARE- MCKINNEY:
<br />OP(24-27)HD, 1-1/4" DIA., MATCH EXISTING FINISH).
<br />PROVIDE DECAL ON ENTRANCE DOOR WITH ACCESSIBLE
<br />DIAGRAM. DECAL TO BE CLEAR WITH BLUE IMAGE. SIGNAGE
<br />TO MEET ADAAG STANDARDS FOR ACCESSIBLE SIGNAGE.
<br />11. FLOOR MAT - WATERHOG PREMIER (CHESNUT BROWN).
<br />12. CASED OPENING, MIN. 32" CLEAR WIDTH OPENING.
<br />13. EXISTING WATER HEATER TO REMAIN, SEE PLUMBING
<br />DRAWINGS.
<br />14. NEW UNISEX BATHROOMS, SEE 4 & 5/A2-1, PLUMBING AND
<br />ELECTRICAL DRAWINGS. REPAIR AND/OR REPLACE EXISTING
<br />CEILING TILE IN THE HALL AND BREAKROOM AS NECESSARY.
<br />MATCH ALL NEW CEILING TO EXISTING.
<br />15. CLOSE-UP AND PATCH DEMOLISHED DOOR OPENING.
<br />16. REPLACE EXISTING DOOR HARDWARE WITH LEVER STYLE
<br />HARDWARE. SCHLAGE: AL -SERIES LEVER, JUPITER LOCK SET,
<br />FINISH: 613, OR EQUAL MANUFACTURER AND LEVER STYLE.
<br />17. MODIFY EXISTING TELLER STATION AS NECESSARY TO ADD AN
<br />ACCESSIBLE SHELF, SEE 6, 7 & 8/A2-1.
<br />18. REMOVE EXISTING CHECK STAND. REPLACE WITH NEW BANK
<br />STANDARD CHECK STAND, OWNER PROVIDED.
<br />a
<br />CONSTRUCTION NOTES
<br />1. EXISTING CONDITIONS INFORMATION HAS BEEN OBTAINED FROM THE
<br />OWNER FURNISHED AS -BUILT DRAWINGS. IT IS THE RESPONSIBILITY OF
<br />THE GENERAL CONTRACTOR TO VERIFY AND MAKE ACCOMODATIONS FOR
<br />THE EXISTING CONDITIONS PRIOR TO BEGINNING THIS SCOPE OF WORK.
<br />2. ALL OTHER EXISTING CONSTRUCTION NOT AFFECTED BY WORK SHOWN
<br />ON THIS PLAN IS TO REMAIN UNLESS OTHERWISE DIRECTED BY THE
<br />OWNER.
<br />3. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. ALL
<br />PARTITION LOCATIONS SHALL BE AS SHOWN ON THE PARTITION PLAN. IN
<br />CASE OF CONFLICT NOTIFY THE ARCHITECT. THE PARTITION PLAN BY THE
<br />ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS.
<br />4. MUD, TAPE, SAND OR PATCH AND PREPARE ALL EXISTING REMAINING
<br />CORE, INTERIOR AND PERIMETER PARTITIONS, AS AFFECTED BY
<br />DEMOLITION OR EXISTING DAMAGED CONDITION, AS NECESSARY, FOR
<br />APPLICATION OF NEW SPECIFIED WALL FINISH. THIS INCLUDES SKIM
<br />COATING OF EXISTING SURFACES WHERE ROUGH PLASTER EXISTS. THERE
<br />SHALL BE NO VISIBLE JOINTS AND ALL SURFACES SHALL BE ALIGNED AND
<br />SANDED SMOOTH.
<br />5. ALL PARTITIONS TO BE BUILT AS PER BUILDING STANDARD
<br />SPECIFICATIONS AND DETAILS.
<br />6. METAL STUD/GYPSUM BOARD WALLS ARE DIMENSIONED TO FINISHED
<br />FACE OF GYPSUM BOARD, U.N.O.
<br />7. DIMENSIONS NOTED "CLEAR," "CLR," OR "MIN" MUST BE ACCURATELY
<br />MAINTAINED, SHALL ALLOW FOR THICKNESS OF ALL WALL FINISHES AND
<br />SHALL NOT VARY MORE THAN +/- 1/8" WITHOUT WRITTEN INSTRUCTION
<br />FROM ARCHITECT.
<br />8. DIMENSIONS MARKED +/- MEAN A TOLERANCE NOT GREATER NORE
<br />SMALLER THAN 2" FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD
<br />DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE
<br />ARCHITECT'S APPROVAL.
<br />9. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE INSIDE
<br />FACE OF THE KNEE WALL, U.N.O.
<br />10. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN
<br />THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF
<br />PARTITION LAYOUT, NOTIFY THE ARCHITECT. VERIFICATION OF THE
<br />LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION
<br />INSTALLATION.
<br />11. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM.
<br />12. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE
<br />AND TRUE, AND IN PROPER ALIGNMENT.
<br />13. ALL BUILDING WINDOW MULLIONS, SILLS AND OTHER INTERIOR METAL
<br />TRIM IS TO BE CLEAN AND FREE OF ALL CONSTRUCTION MATERIAL.
<br />14. REFER TO MILLWORK SHOP DRAWINGS FOR SPECIFIC DETAILS OF
<br />COORDINATION BETWEEN DRYWALL/MILLWORK CONDITIONS.
<br />15. REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND
<br />PLENUM BARRIER LOCATIONS.
<br />16. REFER TO COVER SHEET FOR ADDITIONAL NOTES, LEGENDS, SYMBOLS,
<br />ABBREVIATIONS AND SCHEDULES.
<br />17. REFER TO POWER PLANS FOR LOCATIONS OF SWITCHES, OUTLETS AND
<br />THE LIKE TO BE REMOVED. PATCH AND REPAIR PARTITION TO MATCH
<br />ADJACENT SURFACE AND FINISH.
<br />19. ALL THERMOSTATS TO BE LOCATED 69" A.F.F. (TO BOTTOM OF DEVICE).
<br />LOCATIONS TO BE REVIEWED BY ARCHITECT, PRIOR TO INSTALLATION
<br />AND COORDINATED WITH THE FURNITURE PLAN.
<br />20. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR PIPING SHALL
<br />BE FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE
<br />BUILDING AND FIRE CODES.
<br />21. TRIM THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED
<br />FLOOR. AS APPLICABLE, BY 1/4" MAXIMUM. VERIFY SLAB CONDITIONS.
<br />TRIM EACH DOOR TO FIT CONDITION. WHERE RADICAL VARIATIONS IN
<br />FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH BOTTOM
<br />STILE SIZED TO ACCOMODATE THESE UNDERCUT CONDITIONS.
<br />22. PATCH EXISTING SLAB AS NECESSARY FOR INSTALLATION OF NEW
<br />FLOORING. FLOOR SLAB THROUGHOUT TO BE PREPPED FOR NEW
<br />FLOORING INSTALLATION U.N.O. AS PART OF BASE CONSTRUCTION,
<br />INCLUDING REMOVAL OF EXISTING ADHESIVES, AS DEEMED
<br />NECESSARY.
<br />23. PROVIDE BUILDING STANDARD, WALL MOUNTED DOOR STOPS AT ALL
<br />DOOR LOCATIONS WHERE DOOR SWINGS AGAINST WALL WHERE
<br />LAYOUT DICTATES, SUBSTITUTE FLOOR MOUNTED STOP.
<br />24. OFFSET ALL DOORS 4" FROM ADJACENT CORNER, U.N.O.
<br />25. ALL DOORS SHALL HAVE V-6" CLEAR ON THE STRIKE/PULL SIDE OF THE
<br />DOOR. VERIFY AND REPORT TO ARCHITECT OF EXCEPTIONS PRIOR TO
<br />CLOSING OUT PARTITIONS.
<br />26. TOUCH-UP EXISTING AND RELOCATED DOORS AND FRAMES AS
<br />NECESSARY.
<br />27. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB,
<br />U.N.O.
<br />28. ALL GLASS SHALL BE CLEAR TEMPERED GLASS U.N.O. GLAZING TONG
<br />MARKS SHALL NOT BE VISIBLE. CLEAN AND POLISH ALL GLASS PRIOR
<br />TO PROJECT DELIVERY.
<br />29. CEILING HEIGHT PARTITIONS SHALL BE INSTALLED TIGHT TO FINISHED
<br />CEILING: WITH NO JOINTS VARYING MORE THAN 1/8" OVER 6-0" AND
<br />NO JOINTS GREATER THAN 3/16", U.N.O.
<br />30. "ALIGN" MEANS TO ACCURATELY LOCATED FINISHED FACES IN THE
<br />SAME PLANE.
<br />31. ALL NEW PARTITIONS TO BE 3-5/8" METAL STUD 16" O.C. WITH ONE
<br />LAYER OF 5/8" TYPE 'X' GYP. BD. EACH SIDE, U.N.O. WALL HEIGHT TO
<br />BE TO CEILING, U.N.O.
<br />32. PROVIDE AUDIO/VISUAL FIRE STROBES AND FIRE EXTINGUISHERS AS
<br />NECESSARY FOR CODE COMPLIANCE.
<br />33. PROVIDE PIPE INSULATION UNDER ACCESSIBLE SINKS WHERE
<br />APPLICABLE.
<br />34. CONTRACTOR SHALL ADD SOLID WALL BLOCKING PER MANUFACTURER'S
<br />RECOMMENDATION FOR THE INSTALLATION OF WALL HUNG SINKS AND
<br />TOILETS.
<br />Florida Certificate of Authorization Number: AA26001403
<br />1349 West Peachtree Street, NE, Ste. 1300
<br />Atlanta, GA 30309
<br />Phone: (404) 873-3697
<br />Fax: (678) 904-1510
<br />Frederick Geheber
<br />Seal:
<br />Consultant:
<br />CBRE BANK OF AMERICA
<br />CB RICHARD ELLIS
<br />Bank of America 6700 Lakeview Center
<br />rive
<br />Second Floor
<br />Client: Tampa, Florida 33619
<br />Permit Set
<br />Client Review Set
<br />Description:
<br />11-25-2009
<br />SER
<br />SER
<br />11-13-2009
<br />1 No: 1
<br />BY:
<br />1 Date:
<br />BANK OF AMERICA ADA REMEDIATION
<br />Zephyrhills Location
<br />5632 Gall Boulevard
<br />Zephyrhills, Florida 33539
<br />Project Title & Address:
<br />Construction Plan
<br />Sheet Title:
<br />Proj. No.:
<br />09.00683.00
<br />Drawn By:
<br />Checke
<br />___ d By: Al-1
<br />P.M.. - -- -
<br />SARAN ROLAND
<br />ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON
<br />SITE BY THE CONTRACTOR AND SUB -CONTRACTORS. THE PROJECT
<br />MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR
<br />TO PROCEEDING WITH THE WORK.