Laserfiche WebLink
CONSTRUCTION PLAN <br />1/8" = 1'-o" <br />KEY NOTES <br />1. AERIAL HANDICAP SIGN, SEE DETAIL 1/A2-1. <br />2. VAN ACCESSIBLE PARKING SPACE, PROVIDE PROPER <br />STRIPPING AND ADA SYMBOL PER ADAAG GUIDELINES. <br />3. HANDICAP PARKING SPACE, PROVIDE PROPER STRIPPING AND <br />ADA SYMBOL PER ADAAG GUIDELINES. <br />4. ACCESS AISLE, STRIP AS REQUIRED BY ADAAG STANDARDS. <br />5. VAN ACCESSIBLE SPACE VERTICAL SIGN, TO MEET ADAAG <br />GUIDELINES, SEE 2/A2-1. <br />6. ACCESSIBLE SPACE VERTICAL SIGN, TO MEET ADAAG <br />GUIDELINES, SEE 2/A2-1. <br />7. DETECTABLE WARNINGS PER FLORIDA BUILDING CODE, (MIN. <br />36" DEEP). <br />8. CURB RAMP MEETING ADAAG STANDARDS, SEE 3/A2-1. <br />9. RE -PAVE ACCESSIBLE ROUTE ON EXTERIOR BUILDING SO <br />THAT THE MAX. SLOPE IS 2% IN ALL DIRECTIONS. <br />10. INSTALL NEW CLOSERS (TO ACHIEVE A MAXIMUM OPENING <br />FORCE OF 5LBF) AND DOOR PULLS (HARDWARE- MCKINNEY: <br />OP(24-27)HD, 1-1/4" DIA., MATCH EXISTING FINISH). <br />PROVIDE DECAL ON ENTRANCE DOOR WITH ACCESSIBLE <br />DIAGRAM. DECAL TO BE CLEAR WITH BLUE IMAGE. SIGNAGE <br />TO MEET ADAAG STANDARDS FOR ACCESSIBLE SIGNAGE. <br />11. FLOOR MAT - WATERHOG PREMIER (CHESNUT BROWN). <br />12. CASED OPENING, MIN. 32" CLEAR WIDTH OPENING. <br />13. EXISTING WATER HEATER TO REMAIN, SEE PLUMBING <br />DRAWINGS. <br />14. NEW UNISEX BATHROOMS, SEE 4 & 5/A2-1, PLUMBING AND <br />ELECTRICAL DRAWINGS. REPAIR AND/OR REPLACE EXISTING <br />CEILING TILE IN THE HALL AND BREAKROOM AS NECESSARY. <br />MATCH ALL NEW CEILING TO EXISTING. <br />15. CLOSE-UP AND PATCH DEMOLISHED DOOR OPENING. <br />16. REPLACE EXISTING DOOR HARDWARE WITH LEVER STYLE <br />HARDWARE. SCHLAGE: AL -SERIES LEVER, JUPITER LOCK SET, <br />FINISH: 613, OR EQUAL MANUFACTURER AND LEVER STYLE. <br />17. MODIFY EXISTING TELLER STATION AS NECESSARY TO ADD AN <br />ACCESSIBLE SHELF, SEE 6, 7 & 8/A2-1. <br />18. REMOVE EXISTING CHECK STAND. REPLACE WITH NEW BANK <br />STANDARD CHECK STAND, OWNER PROVIDED. <br />a <br />CONSTRUCTION NOTES <br />1. EXISTING CONDITIONS INFORMATION HAS BEEN OBTAINED FROM THE <br />OWNER FURNISHED AS -BUILT DRAWINGS. IT IS THE RESPONSIBILITY OF <br />THE GENERAL CONTRACTOR TO VERIFY AND MAKE ACCOMODATIONS FOR <br />THE EXISTING CONDITIONS PRIOR TO BEGINNING THIS SCOPE OF WORK. <br />2. ALL OTHER EXISTING CONSTRUCTION NOT AFFECTED BY WORK SHOWN <br />ON THIS PLAN IS TO REMAIN UNLESS OTHERWISE DIRECTED BY THE <br />OWNER. <br />3. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. ALL <br />PARTITION LOCATIONS SHALL BE AS SHOWN ON THE PARTITION PLAN. IN <br />CASE OF CONFLICT NOTIFY THE ARCHITECT. THE PARTITION PLAN BY THE <br />ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. <br />4. MUD, TAPE, SAND OR PATCH AND PREPARE ALL EXISTING REMAINING <br />CORE, INTERIOR AND PERIMETER PARTITIONS, AS AFFECTED BY <br />DEMOLITION OR EXISTING DAMAGED CONDITION, AS NECESSARY, FOR <br />APPLICATION OF NEW SPECIFIED WALL FINISH. THIS INCLUDES SKIM <br />COATING OF EXISTING SURFACES WHERE ROUGH PLASTER EXISTS. THERE <br />SHALL BE NO VISIBLE JOINTS AND ALL SURFACES SHALL BE ALIGNED AND <br />SANDED SMOOTH. <br />5. ALL PARTITIONS TO BE BUILT AS PER BUILDING STANDARD <br />SPECIFICATIONS AND DETAILS. <br />6. METAL STUD/GYPSUM BOARD WALLS ARE DIMENSIONED TO FINISHED <br />FACE OF GYPSUM BOARD, U.N.O. <br />7. DIMENSIONS NOTED "CLEAR," "CLR," OR "MIN" MUST BE ACCURATELY <br />MAINTAINED, SHALL ALLOW FOR THICKNESS OF ALL WALL FINISHES AND <br />SHALL NOT VARY MORE THAN +/- 1/8" WITHOUT WRITTEN INSTRUCTION <br />FROM ARCHITECT. <br />8. DIMENSIONS MARKED +/- MEAN A TOLERANCE NOT GREATER NORE <br />SMALLER THAN 2" FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD <br />DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE <br />ARCHITECT'S APPROVAL. <br />9. ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE INSIDE <br />FACE OF THE KNEE WALL, U.N.O. <br />10. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN <br />THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF <br />PARTITION LAYOUT, NOTIFY THE ARCHITECT. VERIFICATION OF THE <br />LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION <br />INSTALLATION. <br />11. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM. <br />12. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE <br />AND TRUE, AND IN PROPER ALIGNMENT. <br />13. ALL BUILDING WINDOW MULLIONS, SILLS AND OTHER INTERIOR METAL <br />TRIM IS TO BE CLEAN AND FREE OF ALL CONSTRUCTION MATERIAL. <br />14. REFER TO MILLWORK SHOP DRAWINGS FOR SPECIFIC DETAILS OF <br />COORDINATION BETWEEN DRYWALL/MILLWORK CONDITIONS. <br />15. REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND <br />PLENUM BARRIER LOCATIONS. <br />16. REFER TO COVER SHEET FOR ADDITIONAL NOTES, LEGENDS, SYMBOLS, <br />ABBREVIATIONS AND SCHEDULES. <br />17. REFER TO POWER PLANS FOR LOCATIONS OF SWITCHES, OUTLETS AND <br />THE LIKE TO BE REMOVED. PATCH AND REPAIR PARTITION TO MATCH <br />ADJACENT SURFACE AND FINISH. <br />19. ALL THERMOSTATS TO BE LOCATED 69" A.F.F. (TO BOTTOM OF DEVICE). <br />LOCATIONS TO BE REVIEWED BY ARCHITECT, PRIOR TO INSTALLATION <br />AND COORDINATED WITH THE FURNITURE PLAN. <br />20. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR PIPING SHALL <br />BE FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE <br />BUILDING AND FIRE CODES. <br />21. TRIM THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED <br />FLOOR. AS APPLICABLE, BY 1/4" MAXIMUM. VERIFY SLAB CONDITIONS. <br />TRIM EACH DOOR TO FIT CONDITION. WHERE RADICAL VARIATIONS IN <br />FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH BOTTOM <br />STILE SIZED TO ACCOMODATE THESE UNDERCUT CONDITIONS. <br />22. PATCH EXISTING SLAB AS NECESSARY FOR INSTALLATION OF NEW <br />FLOORING. FLOOR SLAB THROUGHOUT TO BE PREPPED FOR NEW <br />FLOORING INSTALLATION U.N.O. AS PART OF BASE CONSTRUCTION, <br />INCLUDING REMOVAL OF EXISTING ADHESIVES, AS DEEMED <br />NECESSARY. <br />23. PROVIDE BUILDING STANDARD, WALL MOUNTED DOOR STOPS AT ALL <br />DOOR LOCATIONS WHERE DOOR SWINGS AGAINST WALL WHERE <br />LAYOUT DICTATES, SUBSTITUTE FLOOR MOUNTED STOP. <br />24. OFFSET ALL DOORS 4" FROM ADJACENT CORNER, U.N.O. <br />25. ALL DOORS SHALL HAVE V-6" CLEAR ON THE STRIKE/PULL SIDE OF THE <br />DOOR. VERIFY AND REPORT TO ARCHITECT OF EXCEPTIONS PRIOR TO <br />CLOSING OUT PARTITIONS. <br />26. TOUCH-UP EXISTING AND RELOCATED DOORS AND FRAMES AS <br />NECESSARY. <br />27. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB, <br />U.N.O. <br />28. ALL GLASS SHALL BE CLEAR TEMPERED GLASS U.N.O. GLAZING TONG <br />MARKS SHALL NOT BE VISIBLE. CLEAN AND POLISH ALL GLASS PRIOR <br />TO PROJECT DELIVERY. <br />29. CEILING HEIGHT PARTITIONS SHALL BE INSTALLED TIGHT TO FINISHED <br />CEILING: WITH NO JOINTS VARYING MORE THAN 1/8" OVER 6-0" AND <br />NO JOINTS GREATER THAN 3/16", U.N.O. <br />30. "ALIGN" MEANS TO ACCURATELY LOCATED FINISHED FACES IN THE <br />SAME PLANE. <br />31. ALL NEW PARTITIONS TO BE 3-5/8" METAL STUD 16" O.C. WITH ONE <br />LAYER OF 5/8" TYPE 'X' GYP. BD. EACH SIDE, U.N.O. WALL HEIGHT TO <br />BE TO CEILING, U.N.O. <br />32. PROVIDE AUDIO/VISUAL FIRE STROBES AND FIRE EXTINGUISHERS AS <br />NECESSARY FOR CODE COMPLIANCE. <br />33. PROVIDE PIPE INSULATION UNDER ACCESSIBLE SINKS WHERE <br />APPLICABLE. <br />34. CONTRACTOR SHALL ADD SOLID WALL BLOCKING PER MANUFACTURER'S <br />RECOMMENDATION FOR THE INSTALLATION OF WALL HUNG SINKS AND <br />TOILETS. <br />Florida Certificate of Authorization Number: AA26001403 <br />1349 West Peachtree Street, NE, Ste. 1300 <br />Atlanta, GA 30309 <br />Phone: (404) 873-3697 <br />Fax: (678) 904-1510 <br />Frederick Geheber <br />Seal: <br />Consultant: <br />CBRE BANK OF AMERICA <br />CB RICHARD ELLIS <br />Bank of America 6700 Lakeview Center <br />rive <br />Second Floor <br />Client: Tampa, Florida 33619 <br />Permit Set <br />Client Review Set <br />Description: <br />11-25-2009 <br />SER <br />SER <br />11-13-2009 <br />1 No: 1 <br />BY: <br />1 Date: <br />BANK OF AMERICA ADA REMEDIATION <br />Zephyrhills Location <br />5632 Gall Boulevard <br />Zephyrhills, Florida 33539 <br />Project Title & Address: <br />Construction Plan <br />Sheet Title: <br />Proj. No.: <br />09.00683.00 <br />Drawn By: <br />Checke <br />___ d By: Al-1 <br />P.M.. - -- - <br />SARAN ROLAND <br />ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON <br />SITE BY THE CONTRACTOR AND SUB -CONTRACTORS. THE PROJECT <br />MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR <br />TO PROCEEDING WITH THE WORK. <br />© NELSON ALL RIGHTS RESERVED <br />