Laserfiche WebLink
e <br />GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2011 FLORIDA BUILDING CODE <br />SOIL TERMITE TREATMENT: <br />6TH EDITION AND THE 2011 FLORIDA BUILDING CODE -RESIDENTIAL 6TH EDITION, <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />ARKAY ENGINEERING, INC,: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />ENGINEERING COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />OF THIS STRUCTURE. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE <br />SHALL STATE <br />FOLLOWING SUPERIMPOSED LOADS: <br />SLAB: <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />LIVE LOAD - 50 P.S,F, <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEAD LOAD - 10 P.S.F. <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES," <br />ROOF: <br />F A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F. <br />ABOVE DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.9,F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED) <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S,F, <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S,F, <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />WIND: <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31: PER 2011 FLORIDA <br />$gGKFILLING t COMPACTION ARE COMPLETE <br />BUILDING CODE, RESIDENTIAL 6TH ADDITION - SECTION R301.2,1,1, AND 2011 FLORIDA BUILDING <br />GORE 6TH ADDITION SECTION 1609 <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />COMPONENT t CLADDING WIND LOADS <br />WIND DESIGN ASSUMPTIONS: <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />BUILDING EXPOSURE - B <br />BUILDING <br />ROOF OVERHANG <br />ALL OTHER <br />WITH PERMANENT METAL OR PLASTIC FORMS, PERMANENT FORMS MUST BE OF AN <br />BUILDING RISK CATEGORY - II <br />ZONE <br />LOADS <br />COMPONENT <br />ADEQUATE SIZE t DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />MEAN ROOF HEIGHT 30' OR LESS <br />LOADS <br />INITIAL TREATMENT, <br />HEIGHT t EXPOSURE ADJUSTMENT <br />COEFFICIENT - IA <br />1 <br />N/A <br />+32,3/-35,3 <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />ENCLOSED BUILDING <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />INTERNAL PRESSURE COEFFICIENT = +/- 0,18 <br />2 <br />-65,1 <br />+32,3/-56,2 <br />SHALL BE REQUIRED <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />3 <br />-110,6 <br />+32,3/-8S.0 <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />4 <br />N/A <br />+353/-38,2 <br />WALLS AND INTERIOR WALLS SHALL BE <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />TYPE V CONSTRUCTION PER FBC 602,5 <br />5 <br />N/A <br />+35.3/-41,2 <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />SOIL BEARING d COMPACTION: <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION), ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S,F, <br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />ON THE SITE IS PROPERLY PREPARED t COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F. <br />BUILDING SIDEWALLS <br />FOUNDATION LOADING. <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />ARKAY ENGINEERING, INC,: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />AND WITHIN 12 INCHES OF THE BUILDING, THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />NOR PERFORMING ANY SOIL TESTING, <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />ARKAY ENGINEERING, INC. SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />THE BUILDING LOADS. <br />FOR FUTURE TERMITE INFESTATIONS <br />FOUNDATIONS 4 SLAB -ON -GRADE: <br />TRUSSES: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA, <br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS ARKAY ENGINEERING, INC, IS <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING, <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT. <br />COMPACTED AND TERMITE POISONED SOIL. <br />EXTERIOR WINDOWS DOOR ASSEMBLIES: <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.L <br />ALL EXTERIOR WINDOW t GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/152 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR "6 REBAR t 35" FOR 01 REBAR, <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1,5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER <br />INSTALL ALL WINDOW t DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />FINAL SITE GRADING), THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />TO ACHEIvE THE DESIGN PRESSURES SPECIFIED. <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />ELECTRICAL, PLUMBING d MECHANICAL: <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />IN ACCORDANCE WITH CHAPTER 411,003(2)(1) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS. <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />MASONRY WALLS: <br />ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN 6 FEET OF SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT. <br />EXTERIOR <br />CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-SO <br />ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />AND SHALL HAVE A MINIMUM F'M OF 1,500 P.S.I. <br />"AFI" CIRCUIT, <br />MORTAR SHALL CONFORM TO ASTM C-210 AND SHALL BE EITHER TYPE M OR S. <br />SAFETY GLAZING: <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />WITH ASTM A-615, LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />FOR "5 REBAR, 30" FOR Oro REBAR t 35" FOR 01 REBAR, <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE <br />ASSEMBLIES, <br />OF 3/8", PLACED AT AN 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />OF 2,500 P.S.I. (WHEN TESTED PER ASTM C-1019). <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN INCHES ABOVE THE DRAIN INLET. <br />PROVIDE CLEAN -OUT OPENINGS (12 SQ, IN,) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN <br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT, <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />N <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />TIMBER MATERIALS: <br />FINISHED FLOOR OR WALKING SURFACE. <br />IF DESIRED, EQUIVALENT CONNECTORS MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />"USP" OR "SIMPSON" CONNECTORS SHOWN. <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN S SQ, FT, <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T. <br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR, <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />MAXIMUM 24 OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />PLANE OF THE GLAZING. <br />GARAGE: <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R305 FOR ADDITIONAL AREAS <br />CHAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING, <br />NO OPENINGS SHALL BE PERMITTED FROM A GARAGE INTO A SLEEPING ROOM, OTHER OPENINGS <br />BETWEEN THE GARAGE AND RESIDENCE SHALL HAVE A DOOR (MIN. 1 3/8" THICK), OF SOLID WOOD, <br />SOLID OR HONEYCOMB CORE STEEL, OR 20-MINUTE FIRE -RATED WITH SELF CLOSING HINGES. <br />DRAFTSTOPPING: <br />WALLS SEPARATING THE GARAGE AND RESIDENCE SHALL HAVE MIN, 1/2" GYPSUM 50ARD <br />APPLIED TO THE GARAGE SIDE. THE CEILING SHALL HAVE MIN. 1/2" GYPSUM BOARD APPLIED <br />I <br />N SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN <br />FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING <br />TO THE GARAGE SIDE, GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY ALL <br />SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY IS BROKEN UP INTO TWO OR <br />HABITABLE ROOMS ABOVE WITH MIN, 5/8" 'TYPE-X' GYPSUM BOARD IN COMPLIANCE WITH THE <br />MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SQ, FT, <br />FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R305 <br />PRODUCT CATEGORY <br />APPROVED PRODUCT LIST <br />SUB CATEGORY MANUFACTURER <br />STATE OF FL. <br />APPROVAL " <br />STRUCTURAL COMPONET <br />LCE4 <br />SIMPSON <br />FL 10446 <br />STRUCTURAL COMPONET <br />A5U66, A15U44 <br />SIMPSON <br />FL 10860 <br />AC4, AC6 <br />STRUCTURAL COMPONET <br />HIO <br />SIMPSON <br />FL 10456 <br />STRUCTURAL COMPONET <br />HETA20 <br />SIMPSON <br />FL 11413 <br />STRUCTURAL COMPONET <br />MBHA HANGERS <br />SIMPSON <br />FL 10852 <br />STRUCTURAL COMPONET <br />LINTEL HEADER <br />CAST CRETE CORP <br />FL 158,1 <br />ROOFING <br />ASPHALT <br />GAF SINGLES ALL <br />FL 10124.1 <br />ROOFING <br />UNDERLAYMENT <br />GAF <br />FL 10626,1 <br />SINGLE HUNG <br />WINDOWS <br />NON IMPACT <br />PLYGEM 1500 <br />FL 16103,1 <br />SOFFIT t FASCIA TRIM <br />SOFFIT AMERICAN CONSTRUCTION METALS <br />FL 12019,1 <br />EXTERIOR DOORS <br />SWINGING <br />PLAST PRO <br />FL 11341,1 <br />EXTERIOR DOORS <br />GARAGE 91211 TO 1612" <br />CLOPNY <br />FL 5684,3 <br />WALL SIDING <br />EXTERIOR <br />HARDI BOARD <br />FL 13IS2.1 <br />LAP SIDING <br />LCLIENTNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />E DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />UT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />DELAY TO THE CONSTRUCTION <br />ATTACH MINIMUM 3/411 P.T, BUCK STRIP <br />THAT IS THE MINIMUM WIDTH OF YOUR <br />WINDOW FRAME USING ,OS1 X 1 3/811 <br />T- NAILS MAXIMUM 10" OC <br />CAULKED WINDOW PEF <br />WINDOW MANUFACTURE <br />RECOMMENDATIONS T <br />LOAD AND COMPRES <br />FOR YOUR JOB LOCA <br />1/2" CDX OR 1/16" 085 ROOF SHEATHING <br />NAILED PER ROOF SHEETING DETAIL WITH _ <br />8D NAILS, USE STEEL PLYCLIPS ,APPROVED <br />UNDERLAYMENT WITH SHINGLES, <br />SEE ROOF TRUSS PLAN <br />2X4 OR 2X6 WOOD SUB WITH <br />ALUMINUM SOFFIT AND FASCI, <br />TRIM <br />SEE LINTEL CHART <br />VINYL FRAME SH WINDOWS <br />MASONRY S <br />GRADE 6"1 <br />GROUND WIRE TO <br />FOOTING REBAR <br />IX4 "2 PINE ATTACHi <br />CORD OF TRUSS WIT <br />INSTALL VINYL UNVE <br />CEILING <br />SECURING WINDOW TO BUCK STRIPS PER <br />YOUR MANUFACTURES INSTRUCTION TO MEET <br />WIND LOAD AND COMPRESSION RATINGS FOR <br />YOUR JOB LOCATION. ALL ANCHOR SCREWS <br />MUST PENETRATE BLOCK WALL A MINIMUM OF <br />1 1/4" AND THERE SHALL BE A MAXIMUM 1/4" <br />AND WINDOW FRAME <br />BLOCK WINDOW ATTACHMENT DETAIL <br />NOT TO SCALE <br />1211 <br />ENGINEERED ROOF <br />TRUSSES 24" OC <br />R-30 INSULATION <br />IN ALL ATTIC AREAS <br />1/2" CEILING TYPE <br />GYPSUM BOARD <br />SINGLE BOND BEAM WITH (1) •5 <br />REBAR CONTINUOUS TIED TO ALL <br />VERTICAL RODS <br />3/4" P.T. FURING WITH 3/4" TUFF R (R4,5) <br />INSULATION BOARD AND 1/2" GYPSUM <br />TYPICAL 411 CONCRETE SLAB WITH WIRE MESH <br />OR FIBER MESH AND 6 MILL VISQUEEN OVER <br />CLEAN COMPACT TERMITE TREATED SOIL <br />105 VERTICAL RODS FROM <br />OLI o'FOOTINGS TO BOND BEAM <br />WITH 25" LAP MINIMUM <br />.1' 16" X 12" FOOTINGS WITH <br />12 (2) 05 REBAR ON CHAIRS <br />BOTTOM OF FOUNDATION <br />MINIMUM 12" BELOW GRADE <br />SI O'I BLOCK WALL DETAIL <br />NOT TO SCALE <br />RU55ES <br />SIMPSON HIO, FILL NAIL <br />HOLES WITH 10DX 1 1/2" NAILS <br />FLOOR PLAN <br />PSON LCE4 AT CORNER POST <br />AC6 AT ALL INTERMEDIATE <br />5T TO BEAM CONNECTIONS, FILL <br />L HOLES WITH IODXI 1/2" NAILS <br />6 X 6 P,T, WOOD POST <br />SIMPSON ABU66 WITH 3/4"X5" EXPANSION <br />BOLT IN SLAB AND FILL NAIL HOLES WITH <br />IODXI 1/2" NAILS <br />PORCH SLAB <br />[, 411 GRADE <br />H 1211 <br />1611X12" MONO FOOTING WITH O O <br />2 •5 REBAR ON CHAIRS <br />1211 <br />REAR PORCH POST 4 5EAM DETAIL <br />NOT TO SCALE <br />GARAGE DOOR TO BE REINFORCED <br />TO MEET WIND LOAD AND COMPRESSION <br />RATINGS FOR YOUR JOB LOCATION. CEILING RAFTER <br />I� ALL TRACK AND HARDWARE SECURED <br />PER MANUFACTURE SPECIFICATIONS TO <br />MEET WIND LOAD AND COMPRESSION <br />RATINGS FOR YOUR JOB LOCATION <br />MINIMUM 2X6 P.T, SIDE PLATE ATTACHED <br />TO BLOCK WALL USING 1/2"X8" ANCHOR <br />BOLTS OR 5/8"Xl" EXPANSION BOLTS <br />4 EACH SIDE. ATTACH TOP 2X6 WITH <br />2 3/8" T NAILS 16" OC <br />GARAGE DOOR ATTACHMENT DETAIL <br />NOT TO SCALE <br />IX4 02 PINE ATTACHED TO BOTTOM <br />CORD OF TRUSS WITH (2) IOD NAILS. <br />INSTALL VINYL UNVENTED SOFFIT AS <br />CEILING <br />SECURE BEAM TO TOP OF 4X4 POST WITH <br />(1) SIMPSON AC4 POST CAP AND FILL ALL <br />NAIL HOLES WITH IODXI 1/2" NAILS, SECURE <br />POST TO BLOCK BASE WITH SIMPSON A51.144 <br />POST BASE WITH 5/8"X6" EXPANSION BOLT <br />AND FILL NAIL HOLES WITH IODXI 1/2" NAILS <br />iv <br />SEE ROOF TRUSS PLAN FOR <br />TRUSS TO BEAM CONNECTION <br />SEE FLOOR PLAN <br />FRAME AROUND POST WITH 2X4 P.T. <br />FRAMING AND COVER WITH HARDI <br />TEXTURE SHEET SIDING <br />16"X16" BLOCK BASE 30" ABOVE PORCH <br />HIGH FLOOR WITH (4) •5 VERTICAL REBAR <br />FROM PAD BELOW, POUR ALL CELLS OF <br />COLUMN WITH 2500 PSI CONCRETE <br />O <br />BOTTOM OF FOUNDATION 24"X24"XI2" CONCRETE PAD WITH (3) <br />MINIMUM 12" BELOW GRADE 21011 05 REBAR EACH WAY, CENTER PAD <br />ON COLUMN LOCATION <br />FRONT PORCH COLUMN < BEAM DETAIL <br />NOT TO SCALE <br />rJ' -Ou <br />51-0u <br />ROOF EDGE <br />O <br />tll <br />O <br />tQ <br />GABLE END <br />1 I 1 I <br />5 -o PARTIAL ROOF PLAN ' -0 <br />ZONE Oj ad RING SHANK NAILS AT 6" O,C, AT EDGES <br />ad RING SHANK NAILS AT 6" O.C. INTERMEDIATE <br />ZONES 2O 3� ad RINGSHANK NAILS AT 6" O,C,, 4" O.C. AT <br />ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL <br />NOTE: END JOINTS FOR SHEATHING SHALL BE STAGGERED <br />AND OCCUR OVER A FRAMING MEMBER. <br />ROOF SHEATHING NAILING <br />ATTACH MINIMUM 3/4" P.T, BUCK <br />STRIP THAT IS THE MINIMUM WIDTH <br />OF DOOR FRAME USING ,091XI 3/8" <br />T- NAILS MAXIMUM 10" OC, <br />CAULK DOOR FRAME <br />MANUFACTURES RECC <br />NOT TO SCALE <br />SECURING PREHUNG TO BUCK STRIPS <br />PER YOUR MANUFACTURES INSTRUCTIONS <br />TO MEET WIND LOADS AND COMPRESSIONS <br />RATINGS FOR YOUR JOB LOCATION, ALL <br />ANCHOR SCREWS MUST PENETRATE BLOCK <br />WALL A MINIMUM OF 1 1/4" AND THERE SHALL <br />BE A MAXIMUM 1/4" SPACE BETWEEN BUCK <br />AND DOOR JAMB <br />BLOCK DOOR ATTACHMENT DETAIL <br />NOT TO SCALE <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERS ` <br />RICHARD L. KID Y P. <br />FLORIDA LICEN E NUMBER 31236 <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2011 6TH EDITION AND ASCE 1-10 <br />FOR 13S MPH WIND ZONE RISK CATEGORY 11 AND THE ENTIRE <br />2011 BUILDING CODE RESIDENTIAL 6TH EDITION <br />co <br />zu " <br />LO <br />ch <br />Z c') <br />Q <br />O r-I <br />O o <br />tnJ N <br />L}L>0 � <br />F— � <br />z Il <br />N <br />Q U ul <br />� Z W xMx <br />1-1 U) Q Q <br />Z cn Wow <br />fzl F� � <br />A z a N <br />m N <br />u? <br />Cofy CO 04 <br />M <br />W <br />2 U_ <br />U_ <br />U_ <br />Z) O <br />CV <br />00 <br />C'M <br />rr <br />ccl <br />� MN <br />�Wm <br />m NQs 9) <br />o I C <br />`p <br />ccq��� <br />m CO <br />Z u- xfa N <br />LL 0 cu <br />*�.13 <br />z Qi -4-9 <br />Q) ILL <br />0 <br />z <br />ui n Q O -0 <br />V -13 9T <br />Y43 0 -13 <br />`° Q) <br />70CoY <br />W '4 u- <br />CO c- <br />w �o-0 <br />C Q) <br />00 <br />� QN� <br />01 <br />3 <br />fV <br />04 <br />1 <br />z <br />N <br />O <br />Q <br />Q <br />z <br />1!1 <br />O <br />nu <br />l--t <br />n <br />la-1 O <br />IL <br />V <br />3 <br />UJ <br />N <br />l <br />4OF1 <br />ARKAY 18683 <br />