Laserfiche WebLink
Y <br />A <br />THE CLIENT UNDERSTANDS TWAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, L055ES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />GENERAL LOADS / UNIT 01 <br />TYPE OF LOAD <br />LIGHTING LOAD 2023 SQ FT X 3VA 6069 <br />SMALL APPLIANCE LOAD 2 CIRCUITS X 1500VA 3000 <br />LAUNDRY LOAD 1 CIRCUITS X 1500VA 1500 <br />LOAD <br />LIGHTING, SMALL APPLIANCE, <br />LAUNDRY FIRST 3000VA X 100 q <br />LIGHTING, SMALL APPLIANCE <br />LAUNDRY REMAINING 1569 VA X 35 q <br />LARGE APPLIANCE LOADS <br />ELECTRIC RANGE NOT OVER 12 KVA <br />CLOTHES DRYER <br />WATER HEATER <br />HVAC HEAT <br />TOTAL VA 10569 <br />TOTAL 3000 VA <br />TOTAL 2650 VA <br />TOTAL 5650 VA <br />8000 VA <br />5500 VA <br />4500 vA <br />6000 vA <br />TOTAL 24000 VA <br />TOTAL vA 28650 VA <br />CONVERT VA TO AMPS <br />29650 DIVIDED BY 240 VOLTS 124 AMPS <br />GENERAL LOADS / UNIT "2 <br />TYPE OF LOAD <br />LIGHTING LOAD <br />1881 SQ FT X 3VA 5661 <br />SMALL APPLIANCE LOAD <br />2 CIRCUITS X 1500VA 3000 <br />LAUNDRY LOAD <br />I CIRCUITS X 1500VA 1500 <br />TOTAL VA 10161 <br />LOAD <br />LIGHTING, SMALL APPLIANCE, <br />LAUNDRY FIRST 3000VA X 100 q <br />TOTAL 3000 VA <br />LIGHTING, SMALL APPLIANCE <br />LAUNDRY REMAINING 1161 VA X 35 3, <br />TOTAL 2506 VA <br />TOTAL 5560 VA <br />LARGE APPLIANCE LOADS <br />ELECTRIC RANGE NOT OVER 12 KVA 8000 VA <br />CLOTHES DRYER <br />5500 vA <br />WATER HEATER <br />4500 VA <br />HVAC HEAT <br />6000 VA <br />TOTAL 24000 VA <br />TOTAL VA 2S560 VA <br />CONVERT VA TO AMPS <br />20560 DIVIDED BY 240 VOLTS 124 AMPS <br />ELECTRICAL LEGEND <br />220 V <br />G.F.I. 110 V <br />110V LIGHT <br />GROUND FAULT <br />RECEPTACLE <br />CAN BE CEILING <br />SWITCH <br />OR WALL (TYP) <br />IIOV 50 CFM'S <br />BATH FAN <br />CEILING FAN <br />110 V <br />WP <br />110 V <br />SMOKE <br />WATERPROOF <br />DETECTOR <br />OUTLET <br />CEILING <br />CARBON <br />FAN W/ LIGHT <br />O MONOXIDE <br />O <br />RECESS CAN LIGHT <br />UNIT <br />c7D EXTERIOR 05L FLOOD <br />ELECTRICAL PANEL <br />VV VV <br />TELEVISION <br />FLUORESCENT <br />FIXTURE G.O.O. <br />® <br />PHONE <br />(rn <br />(� WALL SCONCE <br />� <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT <br />ALL REMAINING OUTLETS IN HOME TO WIRED INTO A ARC -FAULT INTERRUPTER "AFI" CIRCUIT <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS <br />CARBON MONOXIDE ALARM MUST BE INSTALL WITHIN IOb" OF EACH ROOM USED FOR SLEEPING PURPOSES <br />WHEN BUILDING HAS A FOSSIL FUEL BURNING HEATER OR APPLIANCE, A FIREPLACE OR AN ATTACHED <br />GARAGE. <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. <br />VERIFY FLOOD LIGHT <br />SWITCH LOCATION WITH <br />ONWER <br />T® <br />U <br />Cs1=NTf V <br />,/ \ <br />I [ I LEI] <br />i <br />z <br />r V / <br />/ <br />/ <br />/ <br />/ <br />(LLL / <br />PH. <br />TYPICAL ELECTRICAL RISER DIAGRAM <br />3 - 2/0 THHN CU FEEDERS <br />2" GALV RISER <br />I METER <br />GROUND PER N.E.C. <br />16 GROUND <br />NIPPLE <br />CONCRETE ENCASED "LIFER" <br />ELECTRODE REQUIRED PER <br />CURRENT N.E.G. AND MUST <br />BE INSPECTED PRIOR TO <br />CONCRETE PLACEMENT <br />I <br />I <br />I <br />I <br />I' <br />1 <br />1 <br />I , WP'' LLtt <br />I GFVI11 <br />GF GF PH_ <br />/ 1 <br />°"--°----------1$-- <br />I / <br />1 O O <br />I / <br />I <br />1 , <br />1 <br />LL 1 0, n , TV. <br />U I J{,7l JGJo <br />1 <br />I <br />1 I F - - - - - i <br />1 I VJJ�/ I <br />1 \ I (I I� 1 O O <br />, LL <br />wa�wa� <br />M <br />VERIFY FLOOD LIGHT <br />SWITCH LOCATION WITH <br />ONWER <br />IL <br />F id <br />I 6 <br />l7 <br />/ <br />TTICf STAIRS <br />I <br />/ <br />I <br />1 <br />3 LL ' <br />I <br />1 <br />I <br />I <br />1 <br />I <br />1 <br />1 <br />PH. <br />1 <br />o <br />TV. <br />PH. <br />TT <br />1, ,l <br />I <br />I <br />I <br />oL — — — — — — — <br />PH. <br />O �` <br />J <br />------ <br />I LL <br />I <br />1 <br />I \---------- <br />'-w --------------- <br />LL <br />/ <br />I <br />PH. <br />® <br />- \ <br />1 <br />WEFT--- <br />P <br />�\ <br />- --- -- -- - - - - - - - I <br />ELECTRICAL FLAN 1/4 = III oil <br />I <br />1 <br />1 <br />I <br />1 <br />I <br />1 <br />1 <br />/ <br />i <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERO <br />RICHARD L. KI /EYP�.E, <br />FLORIDA LICENSE NUMBER 31296 <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION I6O9 OF THE <br />FLORIDA BUILDINGS CODE 2011 6TH EDITION AND ASCE 1-10 <br />FOR 13S MPH WIND ZONE RISK CATEGORY II AND THE ENTIRE <br />2011 BUILDING CODE RESIDENTIAL 6TH EDITION <br />M <br />Z u " <br />Lo <br />M <br />z M <br />OIx F- <br />O <br />J CV <br />z LL L9 <br />CO <br />�Lo <br />>m — N <br />Q <br />Lo <br />� Z w w <br />'-' Q <br />Z m w— <br />W (f) ~ <br />A Z a N <br />m N <br />I <br />04 <br />m O <br />cM <br />2 U_ <br />LL <br />LL <br />�O <br />N <br />cotn <br />M <br />r. r <br />�Mcr�V <br />dJ to cil <br />Mvo <br />�• <br />to U <br />z U- to IN <br />L ., <br />uom <br />: i <br />z Q) - -4 0 <br />W � U Ll <br />Z Q) Z <br />ca <br />0 � U ' <br />iu n 0 �-UJ <br />�(L <br />L <br />O Q) <br />W <br />c <br />0 rta <br />W <br />.Q <br />Q <br />z <br />0 <br />c <br />} <br />W <br />ff <br />O <br />i� <br />tV <br />(V <br />N <br />6 <br />Q <br />1-- <br />Q <br />ca <br />0 <br />&pf=-I <br />ARKAY N 18683 <br />