GENERAL NOTES:
<br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2017 FLORIDA BUILDING CODE
<br />6TH EDITION
<br />T.L. HANSON A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING
<br />COMPANY; HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE.
<br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE
<br />FOLLOWING SUPERIMPOSED LOADS:
<br />SLAB:
<br />LIVE LOAD - 50 P.S.F.
<br />DEAD LOAD - 10 P.S.F.
<br />ROOF:
<br />LIVE LOAD (TRUSS TOP CHORD) - 20 P.S.F.
<br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED)
<br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F.
<br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 7 P.S.F.
<br />WIND:
<br />BUILDING IS DESIGNED TO CONFORM TO ASCE 7-10, CHAPTERS 26 THRU 31; PER 2017 FLORIDA
<br />BUILDING CODE, RESIDENTIAL 6TH EDITION- SECTION R301.2.1.1. AND 2017 FLORIDA BUILDING CODE
<br />6TH EDITION SECTION 1609.1.1.
<br />COMPONENT & CLADDING WIND LOADS
<br />WIND DESIGN ASSUMPTIONS:
<br />BUILDING EXPOSURE - B
<br />BUILDING RISK CATEGORY - II
<br />MEAN ROOF HEIGHT 30' OR LESS
<br />HEIGHT & EXPOSURE ADJUSTMENT
<br />COEFFICIENT = 1.0
<br />ENCLOSED BUILDING
<br />INTERNAL PRESSURE COEFFICIENT = +/- 0.18
<br />WIND SPEED SHOWN AT THE BOTTOM RIGHT
<br />CORNER OF THIS SHEET
<br />ALL STRUCTURAL ELEMENTS, EXTERIOR
<br />WALLS AND INTERIOR WALLS SHALL BE
<br />TYPE V CONSTRUCTION PER FBC 602.5
<br />SOIL BEARING & COMPACTION:
<br />ALL OTHER
<br />BUILDING
<br />ROOF OVERHANG
<br />COMPONENT
<br />ZONE
<br />LOADS
<br />LOADS
<br />1
<br />N/A
<br />+32.3/-35.3
<br />2
<br />-65.7
<br />+32.3/-56.2
<br />3
<br />-110.6
<br />+32.3/-89.0
<br />4
<br />N/A
<br />+35.3/-38.2
<br />5
<br />N/A
<br />+35.31-47.2
<br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F.
<br />(MINIMUM). THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL
<br />ON THE SITE IS PROPERLY PREPARED & COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P.S.F.
<br />FOUNDATION LOADING.
<br />T.L. HANSON, A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL
<br />ENGINEERING COMPANY; DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE
<br />NOR PERFORMING ANY SOIL TESTING.
<br />T.L. HANSON SHALL NOT BE RESPONISIBLE FOR THE SITE SOILS ABILITY TO SUPPORT
<br />THE BUILDING LOADS.
<br />FOUNDATIONS & SLAB -ON -GRADE:
<br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA
<br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED
<br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING.
<br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY
<br />COMPACTED AND TERMITE POISONED SOIL.
<br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 28 DAY
<br />COMPRESSIVE STRENGTH OF 2,500 P.S.I.
<br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE
<br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25"
<br />FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR.
<br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER
<br />FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE
<br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION
<br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED.
<br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE
<br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND
<br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS.
<br />MASONRY WALLS:
<br />CONCRETE MASONRY UNITS SHALL BE HOLLOW UNIT MASONRY IN ACCORDANCE WITH ASTM C-90
<br />AND SHALL HAVE A MINIMUM FM OF 1,500 P.S.I.
<br />MORTAR SHALL CONFORM TO ASTM C-270 AND SHALL BE EITHER TYPE M OR S.
<br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE
<br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25"
<br />FOR #5 REBAR, 30" FOR #6 REBAR & 35" FOR #7 REBAR.
<br />GROUT FOR THE POURED CELLS AND LINTELS SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE
<br />OF 3/8", PLACED AT AN 8 TO 11 INCH SLUMP AND HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH
<br />OF 2,500 P.S.I. (WHEN TESTED PER ASTM C-1019).
<br />PROVIDE CLEAN -OUT OPENINGS (12 SQ. IN.) IN CELLS CONTAINING SPLICED REINFORCEMENT, WHEN
<br />THE GROUT POUR EXCEEDS 5 FEET IN HEIGHT.
<br />TIMBER MATERIALS:
<br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED
<br />MATERIALS
<br />INTERIOR STUD WALLS TO BE OF 2 X 4 #2 SPRUCE OR BETTER WITH SINGLE 2 X 4 P.T.
<br />PINE BOTTOM PLATE AND SINGLE 2 X 4 #2 SPRUCE TOP PLATE WITH STUDS SPACED
<br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT
<br />GARAGE TO HAVE MINIMUM R-11 INSULATION
<br />DRAFTSTOPPING:
<br />IN SINGLE FAMILY DWELLINGS, DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN
<br />FRAMIMG MEMBERS) IN FLOOR/CEILING ASSEMBLIES SEPARATING USEABLE SPACES. DRAFTSTOPPING
<br />SHALL BE CONSTUCTED SUCH THAT THE FLOOR/CEILING ASSEMBLY IS BROKEN UP INTO TWO OR
<br />MORE APPROXIMATE AREAS WITH NO AREA GREATER THAN 1000 SO. FT.
<br />SOIL TERMITE TREATMENT:
<br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES
<br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR
<br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION.
<br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED
<br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED. THE CERTIFICATE
<br />SHALL STATE
<br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
<br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA
<br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES."
<br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE
<br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE
<br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM
<br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL.
<br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION,
<br />BACKFILLING & COMPACTION ARE COMPLETE
<br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED
<br />(INCLUDING ANY BOXED OR FORMED AREAS) -
<br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE
<br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN
<br />ADEQUATE SIZE & DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE
<br />INITIAL TREATMENT.
<br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL
<br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT
<br />SHALL BE REQUIRED
<br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER
<br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT
<br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE
<br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS
<br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS
<br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION). ANY SOILS DISTURBED AFTER THE
<br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED.
<br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE
<br />BUILDING SIDEWALLS (PER FBC R318).
<br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW
<br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES
<br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS.
<br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE
<br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION
<br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION
<br />FOR FUTURE TERMITE INFESTATIONS
<br />TRUSSES:
<br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE
<br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T. L. HANSON & ASSOCIATES IS
<br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN
<br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT.
<br />EXTERIOR WINDOWS & DOOR ASSEMBLIES:
<br />ALL EXTERIOR WINDOW & GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA
<br />101/IS2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER,
<br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY,
<br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO
<br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE.
<br />INSTALL ALL WINDOW & DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS
<br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED.
<br />ELECTRICAL, PLUMBING & MECHANICAL:
<br />IN ACCORDANCE WITH CHAPTER 471.003(2)(1) OF THE FLORIDA ADMINISTRATIVE CODE; ELECTRICAL,
<br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO
<br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON
<br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS,
<br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN 6 FEET OF SINKS), GARAGE AND AT
<br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT.
<br />ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER
<br />"AR" CIRCUIT.
<br />SAFETY GLAZING:
<br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF
<br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308:
<br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR
<br />ASSEMBLIES.
<br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM
<br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL
<br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS
<br />THAN 60 INCHES ABOVE THE DRAIN INLET.
<br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE
<br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A
<br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE
<br />FINISHED FLOOR OR WALKING SURFACE.
<br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS
<br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING
<br />CONDITIONS:
<br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT.
<br />B) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.
<br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.
<br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE
<br />PLANE OF THE GLAZING.
<br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308 FOR ADDITIONAL AREAS
<br />THAT MAY BE CONSIDERED A HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING.
<br />BUILDING DATA:
<br />USE AND OCCUPANCY: BUSINESS GROUP B
<br />TYPE CONSTRUCTION: VB
<br />FIRE PRO i ECTION: NON SPRINKLED
<br />OCCUPANT LOAD CAPACITY:
<br />BUSINESS 492 SQ. FT. 100 GROSS PER SQUARE FOOT = 5 PEOPLE
<br />STORAGE 296 SQ. FT. 300 GROSS PER SQUARE FOOT = 1 PEOPLE
<br />TOTAL OCCUPANCY = 6 PEOPLE
<br />EXISTING PLUMBING FIXTURES MEET REQUIREMENT PER TABLE 403.1
<br />■� A IL ■ A %k ff
<br />rV D E S I G N S I N C
<br />BUILDING DESIGNS
<br />13821 U.S. HWY 98 BY PASS DADE CITY, FLORIDA 33523
<br />OFFICE 352-523-2077 FAX 352-567-2070
<br />OFFICE AND STORAGE ADDITION FOR
<br />ZEPHYRHILLS CHRISTIAN CHRUCH
<br />5940 DOGWOOD STREET
<br />ZEPHYRHILLS, FLORIDA
<br />SITE JOB SITE LOCATION MAP
<br />1
<br />L
<br />6TH EDITION FLORIDA FIRE PREVENTION
<br />6TH EDITION 2017 FLORIDA BUILDING CODE
<br />6TH EDITION 2017 FLORIDA ACCESSIBILITY CODE
<br />6TH EDITION 2017 FLORIDA ENERGY CONSERVATION CODE
<br />6TH EDITION 2017 FLORIDA MECHANICAL CODE
<br />6TH EDITION 2017 FLORIDA PLUMBING CODE
<br />2017 NFPA 10 (STANDARD FOR PORTABLE FIRE EXTINGUISHERS)
<br />2014 NATIONAL ELECTRICAL CODE (NFPA 70)
<br />CONTRACTOR TO PROVIDE TACTICAL SIGNS AS REQUIRED
<br />CONTRACTOR TO PROVIDE SIGNS DESIGNATING TYPE OF ROOF CONSTRUCTION
<br />BUILDING HAS WOOD ROOF SYSTEM
<br />LIGHT FRAME CONSTRUCTION SIGN REQUIRED
<br />INTERIOR FINISHES
<br />TABLE 803.11
<br />INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY'
<br />SPRINKLERED'
<br />NONSPRINKLERED
<br />GROUP
<br />Interior exit stairways and ramps
<br />„
<br />and exit passageways"
<br />Corridors and
<br />enclosure for exit
<br />access stairways
<br />ra
<br />Rooms and
<br />enclosed
<br />spaces`
<br />Interfor exit stairways
<br />ramps and exit
<br />passageways''
<br />Corridors and
<br />enclosure for exit
<br />access stairways
<br />nd s
<br />Rooms and
<br />enclosed
<br />spaces`
<br />A —I & A-2
<br />B
<br />B
<br />C
<br />-- A ---
<br />Air —
<br />— Bs.
<br />—A
<br />B, F,, N1, R—I
<br />B
<br />C
<br />C
<br />B
<br />--
<br />C
<br />R-4 --
<br />B
<br />C
<br />C
<br />A
<br />B
<br />— B
<br />lI
<br />B ----
<br />B
<br />C
<br />A
<br />A
<br />B
<br />i-1
<br />B
<br />C
<br />C
<br />A
<br />B
<br />B
<br />1-2
<br />__.._..._...__.
<br />B- -- -- —
<br />_
<br />— -- B
<br />Bh. '
<br />—
<br />A
<br />A
<br />B
<br />13
<br />4
<br />A'
<br />C
<br />A
<br />A
<br />B
<br />---I-4
<br />--- — B
<br />B
<br />B" '
<br />A
<br />A
<br />B
<br />R-2
<br />_ C
<br />C
<br />C
<br />B
<br />B
<br />C
<br />R-3
<br />C--
<br />- C --
<br />C
<br />C
<br />C
<br />C
<br />S
<br />C
<br />C
<br />C
<br />B
<br />B
<br />c:
<br />17
<br />_.-____ ------
<br />No restrictions
<br />No restrictions
<br />For Si: 1 inch = 25A nun, 1 square foot = 0.0929m2.
<br />a. Class C'. interior finish materials shall he permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby
<br />where applied directly to a noncombustible base or over furring strips applied to a noncombustible base tmdfireblockedas required by Section 803.13.1.
<br />b. In other than Group I-3 occupancies in buildin gs less than three stories above grade plane, Class B interior finish for nonsprinklered bu ldings and Ctrs C
<br />interiorfinish for .spriuklcred buildings shall be permitted iir interior exit sttwe°ays and ramps.
<br />c. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire -resistance rating is required for structural
<br />elements, the enclosing pai titions shrill extend from the floor co the ceiling. Partitions that do not comply with this shall be corm;idered enclosing spaces and the
<br />rooms or spaces on both sides shrill be considered one. In determining the applic ibie icquiremcnts foi ronrns and enclosed spaces, the specific occupancy,
<br />thereuf shall be the govcinin,g, factor regardless of the group classification of the building or stricture.
<br />d_ Lobby areas in Group A-1, A-2 and A-3 occupancies shall not be less than Class B materials.
<br />c. Class C interior finish materials shall be permitted in places of assembly with an occupant load of 300 persons or less.
<br />f. For places of religious worship, wood used for ornamental purposes, trusses, pan.elina or chancel furnishing shah be permitted.
<br />g. Class B material is required where the building exceeds two stories.
<br />h. Class C interior finish materials shall be permitted in administrative spaces.
<br />i. Class C interior finish materials shall be permitted in rooms with a capacity offourpetsons or less.
<br />j. Class B materials shall be permitted as wainscotting extending not more that) 48 inches above the finished floor in corridors and exit access stairways and
<br />ramps.
<br />k. Finish materials as provided for in other sections of this code.
<br />L, Applies when protected Mr an automatic sprinkler system installed in accordance. with Section 903.3.1.1 or 903.3-1.2.
<br />D
<br />PLAN INDEX:
<br />SHEET B 1 : EXISTING FLOOR PLAN
<br />SHEET B 2: PROPOSED FLOOR PLAN
<br />FLORIDA APPROVAL CHART
<br />DOOR AND WINDOW SCHEDULE
<br />SHEET B 3: ELEVATIONS
<br />ROOF SHEATHING DETAIL
<br />EXTERIOR WALL SECTION
<br />INTERIOR WAL SECTION
<br />SHEET B 4: FOUNDATION PLAN
<br />LINTEL DETAIL
<br />LINTEL CHART
<br />SHEET B 5: ROOF TRUSS PLAN
<br />GABLE BRACE DETAIL
<br />MINIMUM TRUSS BRACE DETAIL
<br />VALLEY FRAMING DETAIL
<br />FLASHING DETAIL
<br />SHEET E M : POWER & MECHANICAL PLAN
<br />DROP CEILING & LIGHTING PLAN
<br />FIXTURE LEGEND
<br />Pt
<br />(352) 521i.
<br />-5848
<br />V
<br />oft � �TZ:���v
<br />C +. f Z�H'YR�11I,1.�t
<br />tUlt'M6 OMCIA L t,�i —
<br />T, L. HAN50N
<br />4 ASSOCIATES, INC,
<br />CONSULTING ENGINEERS
<br />ENGINEERING eUSINES5 NO, E5583O
<br />Post Office Box 1128
<br />Dade Cit�i, Florida 33526
<br />THOMAS L, HANSON, PE 38ro54
<br />
|