Li <br />CONSTRUCTION NOTES: <br />1. THE PROJECT IS AN INTERIOR REMODEL. ONLY MINOR EXTERIOR (SHELL) WORK <br />IS PROPOSED. NO SITE WORK IS PROPOSED. <br />2. ALL WORK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH ALL <br />MANUFACTURER'S SPECIFICATIONS, GUIDELINES, AND RECOMMENDATIONS; AS <br />WELL AS ALL PERTINENT FEDERAL, STATE, AND LOCAL CODES AND ORDINACES <br />INCLUDING BUT NOT LIMITED TO: <br />* FLORIDA BUILDING CODE, (2007) W/ 2009 SUPPLEMENTS <br />3. PRIOR TO START OF WORK, GENERAL CONTRACTOR, (G.C.), SHALL REVIEW THESE <br />CONSTRUCTION DOCUMENTS AND THE PRINTED SCOPE OF WORK TO BE <br />PERFORMED UNDER THE CONSTRUCTION CONTRACT WITH A DULY AUTHORIZED <br />REPRESENTATIVE OF THE TENANT, THE ARCHITECT DOES NOT REPRESENT THESE <br />DOCUMENTS AS APPROVED BY THE TENANT. SCOPE OF WORK IS AVAILABLE <br />FROM TENANT'S REPRESENTATIVE. <br />4. THE CONTRACTOR FOR THIS PROJECT SHALL INCLUDE ALL MATERIALS AND <br />LABOR REQUIRED TO COMPLETE THE TOTAL PROJECT. THE CONTRACTOR SHALL <br />FURNISH AND PAY FOR ALL MATERIALS, TOOLS, EQUIPMENT, LABOR, MACHINERY, <br />TRANSPORTATION, HEAT, WATER, UTILITIES, AND ALL OTHER FACILITIES AND <br />SERVICES REQUIRED FOR THE SAFE AND PROPER EXECUTION AND COMPLETION <br />OF THE WORK. <br />5. ALL FINAL COLOR AND FINISH SELECTIONS SHALL BE APPROVED, IN WRITING, BY <br />THE TENANT. IN GENERAL, NEW CONSTRUCTION SHALL MATCH EXISTING AND <br />CONTIGUOUS CONSTRUCTION IN COLOR, FINISH, MANUFACTURER, AND INSTALLATION <br />METHOD. <br />6. G.C. SHALL FIELD VERIFY KEY DIMENSIONS AND CONDITIONS PRIOR TO <br />ORDERING MATERIALS, FINISHES, EQUIPMENT, AND FIXTURES. THESE <br />CONSTRUCTION DOCUMENTS ARE BASED, IN LARGE PART, ON TENANT -SUPPLIED <br />RECORD CONSTRUCTION DOCUMENTS ("AS BUILTS"). THE ARCHITECT DOES NOT <br />REPRESENT THAT HE HAS FIELD -VERIFIED THE RECORD CONSTRUCTION <br />DOCUMENTS AND HE DOES NOT CERTIFY THEIR ACCURACY. <br />7. NOT ALL AREAS OF THE PROJECT LOCATION WERE AVAILABLE FOR <br />OBSERVATION AND VERIFICATION AT THE TIME THESE CONSTRUCTION DOCUMENTS <br />WERE PREPARED. CONSEQUENTLY, THE ARCHITECT DOES NOT CERTIFY THEIR <br />ACCURACY. THESE CONSTRUCTION DOCUMENTS SHALL NOT BE REFERENCED AS <br />A LEASE EXHIBIT. <br />8. GENERAL CONTRACTOR REMAINS SOLELY LIABLE AND RESPONSIBLE FOR THE <br />FOLLOWING: <br />- VERIFICATION OF ALL EXISTING CONDITIONS, UNIT LOCATIONS AND DIMENSIONS <br />COORDINATING W/ TRADES AND TENANT PRIOR TO CONSTRUCTION <br />- IDENTIFICATION AND REMOVAL OF ANY AND ALL HAZARDOUS MATERIALS, <br />INCLUDING, BUT NOT LIMITED TO, ABESTOS-LADEN MATERIALS. (NOTIFY <br />TENANT BEFORE REMOVAL, IN WRITING, IF ANY HAZARDOUS MATERIALS ARE <br />DISCOVERED.) <br />- THE VERIFICATION AND MAINTENANCE OF ALL EXISTING SETBACKS, EASEMENTS, <br />AND ANY DEED RESTRICTIONS. <br />- COORDINATION OF WORKING HOURS, DELIVERIES, TRASH REMOVAL, STORAGE, <br />ETC. WITH LANDLORD. <br />- ERECTION PROCEDURE AND SEQUENCE TO ENSURE THE INTEGRITY OF THE <br />BUILDING AND IT'S COMPONENT PARTS DURING CONSTRUCTION. <br />- COORDINATION OF ARCHITECTURAL, STRUCTURAL, MECHANICAL AND <br />ELECTRICAL DETAILS AND DIMENSIONS. ANY DISCREPANCIES BETWEEN SUCH <br />DETAILS AND DIMENSIONS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO <br />PROCEEDING W/ THE WORK. <br />- ACCESS PANELS WHERE REQUIRED AS PER PLANS, SPECIFICATIONS, OR <br />INSTRUCTIONS. <br />9. THE CONTRACTOR SHALL PROVIDE THE OWNER W/ A SWORN LIST OF <br />SUBCONTRACTORS AND MATERIAL PROVIDED PRIOR TO CONSTRUCTION. THE <br />SAID LIST SHALL BE UPDATED EACH MONTH THEREAFTER. <br />10. FOR ALL INTENTS AND PURPOSES, THE CERTIFICATE OF OCCUPANCY SHALL <br />SERVE AS "SUBSTANTIAL COMPLETION". <br />11. IF THE DRAWINGS AND THE FIELD CONDITIONS ARE NOT IN AGREEMENT, THE <br />CONTRACTOR TO NOTIFY THE G.C. AND/OR ARCHITECT/ENGINEER BEFORE STARTING <br />ANY WORK. ANY INCONSISTENCIES NEED TO BE CORRECTED BEFORE INSTALLATION <br />BEGINS. IF THE CONTRACTOR STARTS INSTALLATION WITHOUT THE CORRECTED <br />DRAWINGS, HE/SHE WILL BE RESPONSIBLE FOR ANY AND ALL COSTS (BEYOND THE <br />ORIGINAL CONTRACTED AMOUNT) INCURRED BY NECESSARY CHANGES TO CORRECT <br />THE INCONSISTENCIES. <br />12. CLEAN INTERIOR AND EXTERIOR OF ALL WINDOW GLASS PRIOR TO TURNING SPACE <br />OVER TO F.D.S. REMOVE ALL TAPE & OTHER ITEMS ATTACHED TO GLASS OR FRAMES. <br />13. G.C. WILL TEST ALL HVAC UNITS FOR HEAT AND COOLING PRIOR TO FDS POSSESSION <br />OF SPACE. <br />DEMOLITION NOTES.- <br />14. ALL EXISTING STRUCTURAL MEMBERS AND ANY EXTERIOR OPENINGS (ALL <br />EXISTING JOB -SITE CONDITIONS) SHALL BE VERIFIED BY THE CONTRACTOR <br />PRIOR TO ANY MODIFICATION. <br />15. ALL NEW INTERIOR CONCRETE SLABS AND FOUNDATION WALLS AND FOOTINGS <br />SHALL HAVE SOIL POISONING UNDER NEW WORK AND SHALL BE INSTALLED BY A <br />LICENSED CONTRACTOR. ALL WORK SHALL BE COMPLETED IN ACCORDANCE <br />WITH ALL STATE AND DEPARTMENT OF AGRICULTURE, STRUCTURAL PEST CONTROL <br />DIVISION REGULATIONS RULES DEFINITIONS AND REQUIREMENTS. <br />16. ALL DIMENSIONAL LUMBER, PLYWOOD, PARTICLE BOARDS, ETC. USED IN <br />CONTRUCTION SHALL BE FIRE RETARDANT (F.R.T.), U/L CERTIFIED NOW <br />COMBUSTIBLE WHENEVER REQUIRED ALL NEW INTERIOR CONCRETE SLABS AND <br />FOUNDATION WALLS AND FOOTINGS SHALL HAVE SOIL POISONING UNDER NEW <br />WORK AND SHALL BE INSTALLED BY A LICENSED CONTRACTOR. <br />17. NO COMBUSTIBLE MATERIALS ARE PERMITTED ABOVE CEILING, INCLUDING F.R.T. <br />LUMBER. <br />18. ALL FIRE RATED WALLS MUST HAVE RATING STENCILED IN A READILY VIEWABLE <br />AREA, PER THE 2006 I.B.C. & NORTH CAROLINA STATE BUILDING CODE (2009). <br />19. THERE SHALL BE NO CHANGES TO OR DEVIATIONS FROM THE REQUIREMENTS OF <br />F.D.'S EXHIBITS OR FROM THE DRAWINGS UNLESS SUCH CHANGES OR DEVIATIONS <br />ARE APPROVED IN WRITING BY TENANT PRIOR TO THE WORK BEING DONE. <br />20. GC TO FIELD VERIFY AND CONFIRM ANY ROOF WORK W/ LANDLORD ON WARRANTY <br />PRIOR TO CONSTRUCTION OR ALTERATIONS. <br />21. ALL PLYWOOD BACKING AND ANY IMPERFECTIONS SHALL BE FILLED AND <br />SANDED SMOOTH TO PROVIDE A CONTINUOUS SMOOTH SURFACE FOR <br />APPLICATION OF FINISH (PAINT OR LAMINATE). <br />22. ALL WOOD PARTITIONS WITH DOORS TO HAVE NON-COMBUSTIBLE WOOD JACK STUDS <br />AND HEADERS. <br />23. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AND <br />MAINTAINING ALL EXISTING SETBACKS, EASEMENTS, AND ANY DEED RESTRICTIONS. <br />24. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CLEANUP AND <br />SHALL INCLUDE THE SITE, AND THE BUILDING. THE ENTIRE PROJECT SHALL BE <br />LEFT IN A NEW, CLEAN CONDITION. <br />25. THE GENERAL CONTRACTOR SHALL MEET WITH THE PLUMBING CONTRACTOR ON <br />SITE PRIOR TO CONSTRUCTION TO VERIFY ANY AND ALL EXISTING PLUMBING <br />CONDITIONS PERTAINING TO THIS PROJECT. MINUTES FROM THIS MEETING AND <br />FINDINGS IN THE FIELD SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO <br />CONSTRUCTION. <br />26. THE GENERAL CONTRACTOR SHALL MEET WITH THE MECHANICAL CONTRACTOR ON <br />SITE PRIOR TO CONSTRUCTION TO VERIFY ANY AND ALL EXISTING HVAC EQUIPMENT <br />PERTAINING TO THIS PROJECT. INCLUDING EXIST. ROOF CURBS, ROOF TOP UNITS, <br />DUCTWORK, REGISTERS, AND ANY AND ALL OTHER ON SITE MECHANICAL <br />EQUIPMENT. MINUTES FROM THIS MEETING AND FINDINGS IN TEH FIELD SHALL BE <br />SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION. <br />27. THE GENERAL CONTRACTOR SHALL MEET WITH THE ELECTRICAL CONTRACTOR ON <br />SITE PRIOR TO CONSTRUCTION TO VERIFY ANY AND ALL EXISTING ELECTRICAL <br />EQUIPMENT PERTAINING TO THIS PROJECT. INCLUDING ELECTRIC PANELS, CONDUIT, <br />AND ANY/ALL OTHER ON -SITE ELECTRICAL EQUIPMENT, ETC. MINUTES FROM THIS <br />MEETING AND FINDINGS <br />IN THE FIELD SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION. <br />28. CLAIMS FOR CONSEQUENTIAL DAMAGES. THE ARCHITECT AND THE OWNER WAIVE <br />CONSEQUENTAIL DAMAGES FOR CLAIMS, DISPUTES OR OTEHR MATTERS IN QUESTION <br />ARISING OUT OF OR RELATING TO THIS PROJECT. THIS MUTAL WAIVER IS <br />APPLICABLE, WITHOUT LIMITATION, TO ALL CONSEQUENTIAL DAMAGES. <br />29. LANDLORD OR GC SHALL PERFORM ANY/ALL WORK REQUIRED TO CAUSE THE ENTIRE <br />DEMISED PREMISES TO COMPLY WITH LAWS PERTAINING TO ACCESSIBILITY BY <br />DISABLED PERSONS (ADA) AND WILL OBTAIN AND INSTALL A CERTIFICATE OF <br />OCCUPANCY AND HEALTH CERTIFICATE (IF REQUIRED). CERTIFICATE(S) SHALL BE <br />INSTALLED IN AN 8-1/2"X11" FRAME ON THE OUTSIDE OF THE OFFICE WALL IN A <br />CONSPICUOUS LOCATION. THIS SHALL BE DONE PRIOR TO DELIVERING THE <br />DEMISED PREMISES TO TENANT. <br />30. ALL STRUCTURAL MEMBERS AND ANY EXTERIOR OPENINGS SHALL BE VERIFIED BY <br />THE CONTRACTOR PRIOR TO CONSTRUCTION OR ALTERATIONS. <br />31. INFILL ALL HOLES, CRACKS AND PENETRATIONS IN THE EXTERIOR WALLS. <br />32. PROVIDE AND FACILITATE A THIRD PART INSPECTION OF ROOF W/ WRITTEN REPORT. <br />1. THESE DRAWINGS HAVE BEEN DEVELOPED FROM <br />6. THE CONTRACTOR SHALL VERIFY THAT EXIT EGRESS <br />14. REMOVE EXISTING CERAMIC TILE FLOOR AND REWORK <br />EXISTING DRAWINGS WHICH MAY NOT REFLECT <br />IS MAINTAINED FOR ALL OCCUPIED AREAS OF THE <br />FLOOR SLAB TO MAKE SMOOTH AND LEVEL. <br />ACTUAL FIELD CONDITIONS. THE CONTRACTOR <br />BUILDING THROUGHOUT ALL PHASES OF <br />15. REMOVE EXISTING FLOORING IN SALES AREA AND <br />SHALL VERIFY THESE DRAWINGS WITH EXISTING <br />CONSTRUCTION. <br />REPAIR SUB -FLOOR AS NECESSARY TO PROVIDE A <br />FIELD CONDITIONS AND NOTIFY THE ARCHITECT <br />IMMEDIATELY OF INCONSISTENCIES BETWEEN THESE <br />7. DEMOLITION WORK SHALL BE EXECUTED IN <br />SMOOTH, LEVEL SURFACE. <br />DRAWINGS AND ACTUAL CONDITIONS BEFORE <br />CONFORMANCE WITH ALL CODES AND ORDINANCES <br />16. REMOVE EXISTING WALL FINISHES AND PREPARE <br />PROCEEDING WITH CONSTRUCTION. <br />AS SET FORTH BY ALL GOVERNING AUTHORITIES. <br />WALLS FOR NEW WORK/FINISHES. <br />2. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT <br />8. THE CONTRACTOR SHALL BRACE ALL EXISTING <br />17. CAP OFF ALL PLUMBING LINES WHICH ARE NOT TO BE <br />IMMEDIATELY IF ANY WORK INDICATED IN THE <br />STRUCTURES AND ALL STRUCTURAL ELEMENTS AS <br />RE -USED FLUSH WITH ADJACENT SURFACES. <br />CONTRACT DOCUMENTS CANNOT BE PERFORMED <br />NECESSARY DURING DEMOLITION. <br />18. CAP OFF OR TERMINATE ALL ELECTRICAL DISTRIBUTION <br />DUE TO EXISTING FIELD CONDITIONS. <br />9. THE CONTRACTOR SHALL NOT CUT STRUCTURAL WORK <br />LINES WHICH ARE NOT TO BE RE -USED FLUSH W/ <br />3. IF ANY EXISTING FIREPROOFING OR FIRE ASSEMBLIES <br />IN A MANNER RESULTING IN A REDUCTION OF LOAD <br />ADJACENT SURFACES. <br />WHICH ARE SUPPOSED TO REMAIN ARE DAMAGED <br />CARRYING CAPACITY OR LOAD/DEFLECTION RATIO. <br />DURING DEMOLITION, THEY SHALL BE REPAIRED TO <br />THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF <br />19. REMOVE ALL LIGHTING FIXTURES THROUGHOUT THE <br />CONFORM TO ORIGINAL FIRE PROTECTION <br />ALL STRUCTURAL CUTS PRIOR TO EXECUTION SO THAT <br />DEMISED PREMISES IN PREPARATION FOR <br />REQUIREMENTS. CONTACT ARCHITECT TO VERIFY U.L. <br />APPROVAL CAN BE OBTAINED FROM THE ARCHITECT <br />INSTALLATION OF NEW F.D.S. SPECIFIED LIGHTING AS <br />ASSEMBLIES TO BE USED FOR REPAIRS. <br />AND STRUCTURAL ENGINEER. <br />INDICATED IN LIGHTING SECTION. <br />4. REMOVE EXISTING CONSTRUCTION AS INDICATED. <br />10. THE EXISTING BUILDING ENVELOPE SHALL BE <br />20. DEMO EXISTING HVAC IN EXISTING DEMISED PREMISES. <br />TYPICAL WALL REMOVAL INCLUDES MECHANICAL, <br />PLUMBING, COMMUNICATIONS, INFORMATION SYSTEMS, <br />MAINTAINED IN WATER TIGHT CONDITION AT ALL TIMES <br />THROUGHOUT ALL PHASES OF CONSTRUCTION. <br />21. REMOVE ALARM PANEL AND COMPONENTS. REMOVE <br />AND ELECTRICAL SYSTEMS CONTAINED THERE IN. <br />EXCESS PHONE EQUIPMENT AND RELATED WIRING. <br />REMOVE DOORS, FRAMES, FINISHES, AND OTHER <br />11. IF THE EXISTING CONSTRUCTION IS FOUND TO CONTAIN <br />CONTACT F.D.S. PROJ. MGR. PROJECT MANAGER TO <br />FIXTURES AS REQUIRED. AFTER REMOVAL OF PIPE <br />ASBESTOS, NOTIFY OWNER AND THE ARCHITECT IN <br />DISCUSS POSSIBLE USE. <br />CHASES, PATCH HOLES IN EXISTING FLOORS, WALLS OR <br />WRITING. REMOVAL, DISPOSAL, AND THE <br />ROOF. PATCH ADJOINING WALLS, FLOOR <br />REPLACEMENT OF THE ASBESTOS MATERIAL SHALL BE <br />IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL <br />22 G.C. TO REMOVE EXISTING AISLE TAPE AND STRIP <br />AND DECK. PREPARE SURFACES TO RECEIVE NEW <br />REGULATIONS. (REPLACE THE ASBESTOS MATERIAL <br />EXISTING FLOOR WAX. <br />FINISH PER FINISH SCHEDULE OR PER INTERIOR <br />DESIGNER'S FINISH PLANS. (WHERE NEW FINISHES <br />WITH NEW MATERIAL AS APPROVED BY THE <br />ARE CALLED FOR ON EXISTING SURFACES, REMOVE <br />ARCHITECT.) <br />THE EXISTING FINISH AND PREPARE SURFACE TO <br />12. THE CONTRACTOR SHALL REPLACE OR REPAIR ANY <br />RECEIVE THE NEW FINISH. <br />EXISTING TO REMAIN FINISHES, ETC., WHICH ARE <br />5. FOR EXTENT AND LOCATION OF CHANNELING OF <br />DAMAGED DURING DEMOLITION (I.E. - CEILING TILE, <br />EXISTING FLOOR SLABS REFER TO MECHANICAL, <br />WALL COVERINGS, FLOOR COVERINGS, CORNER GRID, <br />PLUMBING, FIRE PROTECTION, COMMUNICATIONS, <br />GUARDS, WALL GUARDS, HANDRAILS, CHAIR RAILS, <br />INFORMATION SYSTEMS, AND ELECTRICAL DRAWINGS. <br />MOLDINGS, ETC.). <br />IF EXISTING PIPING OR CONDUIT WORK (OTHER THAN <br />13. REMOVE EXISTING TOILET ROOM(S) SHOWN ON THE <br />THE DESIRED CONNECTION) IS ENCOUNTERED WHILE <br />FLOOR PLAN AND STUB OFF ALL PLUMBING. PATCH <br />CHANNELING, THE CONTRACTOR SHALL NOTIFY THE <br />HOLES IN FLOOR SLAB W/ CONCRETE LEAVING A SMOOTH, <br />ARCHITECT BEFORE CONTINUING. <br />LEVEL SURFACE. REPAIR FLOOR COVERING TO MATCH <br />SURROUNDING FINISH. <br />PROJECT NOTES: <br />1. IN -FILL HOLES/PITS IN CONCRETE SLAB TO MATCH EXISTING. G.C. TO VERIFY IN FIELD <br />FOR LOCATION, DEPTH, AND NECESSARY IN -FILL MATERIALS/SPECIFICATIONS. <br />2. ERECT NEW METAL STUD WALLS AND INSTALL NEW SOLID WOOD DOORS AS <br />INDICATED ON PLAN AND IN DETAILS AND DOOR SCHEDULE. <br />3. REPLACE FLOORING AS INDICATED ON PLAN AND IN FINISH SCHEDULE. <br />4. INSTALL NEW DISPLAY WALL PANEL SYSTEM IN SALES AREA AS INDICATED ON PLAN <br />AND ELEVATIONS. <br />5. ANY AND ALL ALTERATIONS TO THE BUILDING ENVELOPE INCLUDING WALL OPENINGS, <br />CONCRETE SLAB WORK, ROOF PENETRATIONS, ETC. SHALL BE APPROVED BY THE <br />LANDLORD AND PERFORMED BY LANDLORD APPROVED CONTRACTOR. <br />6. VERIFY ALL DIMENSIONS IN FIELD. NOTIFY ARCHITECT OF ANY MAJOR DEVIATIONS <br />FROM THESE PLANS. ALL DIMENSIONS BASED ON EXISTING CONSTRUCTION ARE <br />APPROXIMATE. <br />7. FILL IN ANY MISSING GYP. BOARD OR PEG BOARD FROM FLOOR TO 10'-0" A.F.F. & <br />PREP FOR NEW FINISH. <br />8. ROOF IS EXISTING. G.C. TO FIELD VERIFY AND CONFIRM W/ LANDLORD ON WARRANTY <br />ISSUES PRIOR TO CONSTRUCTION. NO NEW ROOF IN THIS SCOPE OF WORK. <br />PREFERRED VENDORS: <br />COMPANY: <br />CONTACT: <br />EXTERIOR & INTERIOR PAINTS: <br />217-566-2000 <br />SHERWIN WILLIAMS <br />EXTERIOR LIGHTS: <br />800-933-9831 OR <br />LITHONIA, THRU GRAYBAR ELECTRIC <br />704-392-1804 <br />SITE LIGHTING: <br />305-437-7975 <br />LUMINAIRE <br />VINYL COMP. TILE: <br />800-233-3823 ARMSTRONG) <br />SEE FINISH SCHEDULE <br />SEE FINISH SCHEDULE FOR ALT'S <br />TOILET FIXTURES: <br />800-442-1902 <br />AMERICAN STANDARD <br />TOILET ACCESSORIES: <br />BRADLEY (ELEC. HAND DRYER- <br />800-272-3539 <br />"ELECTRIC-AIRE") <br />LOCKS: <br />SCHLAGE <br />800-847-1864 <br />SCOPE OF WORK: <br />CARPENTRY/ETC. <br />STOREFRONT GLASS AND DOORS <br />INTERIOR & EXTERIOR RENOVATION OF FORMER MERCANTILE BUSINESS <br />VERIFY THAT EXISTING EXTERIOR DOORS (ENTRANCE AND RECEIVING) ARE IN PROPER <br />KEY THIS SHEET). <br />OPERATIONAL CONDITION. MAKE ANY REPAIRS NECESSARY T MAKE OPERATIONAL. <br />INCLUDE CRASH BARS ON THE INTERIOR AND EXTERIOR OF EACH DOOR, EXTERIOR KEY <br />IN TOILET ROOM; PROVIDE AND INSTALL T-0 WIDE SOLID CORE WOOD DOORS IN MTL. <br />LOCK WITH INTERIOR THUMB TURN. INSTALL BRUSH STYLE DOOR SWEEPS <br />FRAMES WITH CLOSER (YALE 4020-PAINTED) CLOSURE SHOULD NOT EXCEED ADA <br />MANUFACTURED BY SEALEZE C380CLA06BL (X) WIDTH OF DOOR (OR APPROVED EQUAL). <br />CODE OF 5# OPENING FORCE AND PRIVACY LOCK (SCHLAGE A40S-LEV 626), GYP. <br />THE SHOULD BE NO LIGHT VISIBLE FROM UNDER THE DOOR OR ON THE SIDES. <br />BOARD CEILING AND 3/4n PLYWOOD DECK ABOVE IN THE LOCATION SHOWN ON ON THE <br />FLOOR PLAN. FURNISH ALL SCHEDULED TOILET ROOM ACCESSORIES. ALL WORK <br />SHALL BE IN COMPLIANCE W/ LOCAL AND STATE CODES CODES. INCL. (2) TWO 3'-0 LX8"D <br />INSTALL F.D.S. SPECIFIED WINDOW FILM PER F.D.S. FIXTURE PLAN NOTES 'OPAQUE'. <br />(MIN.) WHITE ADJ. SHELVES OVER EA. TOILET. PROVIDE C.T. AND/OR FRP BOARD. <br />BUDGET TO COVER ALL GLASS EXCEPT FOR 24'-0 WIDE. INSTALL TINT ON STOREFRONT <br />GLASS UP TO 8' AFF IF THE REMAINING EXPOSED GLASS IS 11" OR MORE. OTHERWISE <br />ALL NEW INTERIOR PARTITIONS SHALL BE CONSTRUCTED OF ONE (1) LAYER 5/8" <br />TINT THE ENTIRE HEIGHT OF THE GLASS. <br />GYPSUM WALL BOARD (NON -RATED) ON EACH SIDE OF 3-5/8" (20 GAUGE) <br />PUNCHED-CEE, METAL STUD FRAMING AT 16" ON CENTER (MAXIMUM) UNLESS <br />CLEAN ALL STOREFRONT GLASS INTERIOR AND EXTERIOR. REMOVE DECALS, LABELS <br />NOTED OTHERWISE (FINISH AND PREPARE FOR PAINT). ALL NEW PARTITIONS <br />AND SIGNAGE WHICH ARE NOT TO BE USED. <br />SHALL TERMINATE 6" (MINIMUM) ABOVE HIGHEST CONTIGUOUS CEILING ASSEMBLY <br />CEILING SYSTEMS <br />UNLESS NOTED OTHERWISE. ALL NEW INTERIOR PARTITIONS SHALL BE <br />NONCOMBUSTIBLE. <br />PATCH CEILING GRID AND TILE TO PROVIDE AN UNIFORM CEILING WHERE WALLS WERE <br />CONSTRUCT MANAGER'S OFFICE (IN RECEIVING ROOM) COMPLETE WITH WALLS (3 5/" <br />REMOVED OR ADDED. <br />METAL STUD FRAMING W/ 5/8" METAL STUD FRAMING W/ 5/8" FIRE RATED GYPSUM <br />BOARD), T-O WIDE SOLID CORE WOOD DOOR W/ 180 DEGREE PEEPSITE AT 5'-0 AFF, DOOR <br />REPLACE ALL BROKEN OR DAMAGED CEILING GRID AND ALL MISSING, STAINED OR <br />CLOSER (YALE 4020-PAINTED) CLOSURE SHOULD NOT EXCEED ADA FORCE CODES, <br />DMAGED CEILING TILES W/ NEW MATCHING GRID AND TILES. PAINT ENTIRE CEILING <br />KEYED DEADBOLT W/ INSIDE THUMB TURN PROVIDE LOCK GUARD, STOREROOM <br />'CEILING WHITE' TO PRESENT AN UNIFORM APPEARANCE.. <br />FUNCTION LEVER TYPE DOOR SET (SCHLAGE A80PD-LEV-626). <br />REMOVE ANY EXCESS WIRES, STRINGS, CLIPS, BRACKETS, ETC. FROM CEILING. <br />PATCH AND POINT UP EXISTING DRYWALL FINISH TO MAKE READY FOR PAINT. <br />FLOORING <br />FRAME AND FINISH NEW 6'X7' CASED OPENING IN RECEIVING ROOM WALL FOR NEW <br />DOUBLE SWING DOOR. <br />PROVIDE AND INSTALL NEW VINYL COMPOSITION TILE IN THE MAIN SALES AREA WITH <br />ARMSTRONG #52506'RODEO FAWN' 1/8" TILE OR MANNINGTON #107 BISQUE (PROVIDE <br />PROVIDE BLOCKING IN WALLS FOR ELECTRIC HAND DRYER AND SHELVING IN <br />TRANSITION STRIP AS REQUIRED TO ASSURE SMOOTH TRANSITION). ENSURE THAT A <br />BATHROOMS. LOCATION TO BE DETERMINED BY TENANT CONSTRUCTION <br />SMOOTH SUB FLOOR IS PROVIDED. CLEAN, SEAL, WAX, AND BUFF NEW TILE IN <br />REPRESENTATIVE. <br />ACCORDANCE WITH TILE MANUFACTURER'S SPECIFICATIONS. ENSURE SUBFLOOR IS <br />LEVEL, PATCHED, AND READY FOR TILE. <br />INSTALL MONITOR BRACKET (F.D.S. SUPPLIED) VERIFY LOCATION W/ FDS <br />REPRESENTATIVE. MOUNTING SHOULD MEET ALL STATE AND LOCAL CODES. SEE <br />PROVIDE AND INSTALL NEW VINYL COMPOSITION FLOOR TILE IN MANAGER'S OFFICE W/ <br />ATTACHED CUT SHEET AND INSTRUCTION AND INSTRUCTION MANUAL FOR FURTHER <br />ARMSTRONG #52506, 'RODEO FAWN' 1/8" TILE OR MANNINGTON #107 'BISQUE' (PROVIDE <br />INFORMATION. <br />TRANSITION STRIP AS REQUIRED TO ENSURE SMOOTH TRANSITION AT ALL OPENINGS). <br />CLEAN, SEAL, AND BUFF. <br />SUPPLY AND INSTALL A 96"X48"X3/4" CDX COMMUNICATIONS BOARD FOR USE BY <br />DEMARC CONNECTION AND OUTSIDE INSTALLER. MOUNT AND SECURE BOTTOM OF <br />PROVIDE AND INSTALL NEW VINYL COMPOSITION FLOOR TILE IN TOILET ROOMS W/ <br />BOARD AT 8'-0 AFF. BOARD SHOULD BE ABLE TO CARRY A MIN. OF 225 LBS. SEE PLANS <br />ARMSTRONG #52506, 'RODEO FAWN' 1/8" TILE OR MANNINGTON #107'BISQUE' (PROVIDE <br />FOR EXACT HEIGHT AND LOCATION. <br />TRANSITION STRIP AS REQUIRED TO ENSURE SMOOTH TRANSITION AT ALL OPENINGS). <br />CLEAN, SEAL, AND BUFF. <br />INSTALL FRP (KELMLITE-LASCOBOARD #419 WHITE W/ EMBOSSED FINISH OR APPROVED <br />EQUAL) ON ALL RESTROOM WALLS. INSTALL FRP BEHIND MOP SINK AND WATER COOLER <br />PROVIDE AND INSTALL 4" ARMSTRONG #60 JET BLACK OR MANNINGTON #901 NIGHT <br />AREAS. ALL AREAS OF FRP TO BE INSTALLED UP TO 4' ABOVE FLOOR WITH TRIM CAP ON <br />BLACK COVE BASE ON ALL WALL SURFACES TO RECEIVE PAINT FROM FLOOR TO <br />ALL EDGES. USE MANUFACTURED TRIM FOR JOINTS, CORNERS, AND CAPS. INCLUDE <br />CEILING, INCLUDING ALL INTERIOR SALES FLOOR COLUMNS. CAULK AROUND EACH <br />CAULKING AS REQUIRED. EXTEND FRP MINIMUM OF 1' BEYOND SIDES OF MOP SINK AND <br />COLUMN ON SALES FLOOR. <br />WATER COOLER. <br />PROVIDE AND REPLACE STAINED, CRACKED, CHIPPED, DAMAGE OR MISSING FLOOR <br />PROVIDE AND INSTALL 1"X4" WOOD FURRING STRIPS AT ALL SALES AREA WALLS. <br />TILES THROUGHOUT THE DEMISED PREMISES WITH MATCHING TILES. PROVIDE <br />FURRING STRIPS SHALL BE INSTALLED AT 6'-0 AFF AROUND THE PERIMETER OF THE <br />MATCHING TILE SAMPLE FOR APPROVAL TO THE FDS CONTT. MANAGER. CLEAN, STRIP, <br />SALES AREA WALLS. PAINT WOOD FURRING STRIPS TO MATCH SALES AREA WALL. <br />SEAL, WAX AND BUFF ENTIRE FLOOR. <br />PROVIDE 10 ADDITIONAL 1 "X4"X8'PAINTED FURRING STRIPS. FURRING STRIPS ARE TO <br />REMAIN IN STORE FOR FUTURE USE. <br />REMOVE EXIST, WALL FINISHES AND PREPARE WALL FOR NEW FINISHES. <br />DOORS AND HARDWARE <br />CLEAN, STRIP, SEAL, WAX AND BUFF ALL FLOOR TILE IN SALES AREA, MANAGER'S <br />OFFICE, AND RESTROOMS. <br />PROVIDE AND INSTALL A NEW TXT ELIASON DOUBLE SWING RECEIVING ROOM DOOR <br />(MODEL #LWP3-PR72X84FD). <br />REPAIR AND RE -SEAL CONCRETE FLOOR W/ CLEAR ACRYLIC SEALER. <br />INSTALL ARM-A-DOR-MODEL #A10X-XXX (X-XXX DETERMINED BY WIDTH OF DOOR AND <br />SEAL RECEIVING ROOM FLOOR WITH CLEAR ACRYLIC SEALER. <br />DOOR JAM) SECURITY ALARM AND BAR (F.D.S. SUPPLIED) ON EXISTING EXTERIOR <br />FREIGHT RECEIVING DOOR (CONTACT 704-334-8683 FOR INFORMATION). <br />FILL ANY EXTING COOLER/FREEZER TRENCHES AND MOUNTING POINTS IN SALES FLOOR <br />AND PROVIDE A SMOOTH LEVEL SURFACE. <br />WALLS/PAINTING <br />SPECIFICATIONS <br />GENERAL <br />MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND ARE <br />NOT BASED ON A SITE VISIT. CONTRACTOR TO FURNISH AND INSTALL ALL ITEMS <br />AIPf`PCCADV =r)D A r nRAD1 I=TG GIRCT r`I ACC IAICTAI I ATir)KI r)P TWAT ARP PCCPAITIAI <br />.----- ------ .-- -------------. - -- - -- - - - <br />-- <br />FOR PROPER OPERATION OF WORK INDICATED. <br />ALL WORK ON THIS PROJECT SHALL CONFORM TO THE REQUIREMENTS OF THE <br />'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION DOCUMENT A201 <br />FIFTEENTH ED, 1997 AND ARE HEREBY MADE A PART OF THESES SPECIFICATIONS SD <br />IF BOUND HEREIN AND SHALL APPLY TO ALL DIVISIONS AS THOUGH COPIES IN EACH. <br />CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION TO <br />ENSURE THE SAFETY OF THE BUILDING UNTIL STRUCTURAL SYSTEM IS COMPLETED. <br />THIS INCLUDES BUT NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY <br />BRACING, SHORING, GUYS OR TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL <br />SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER <br />THE COMPLETION OF THE PROJECT. <br />SHOP DRAWINGS AND SAMPLES <br />CONTRACTOR TO PROVIDE OWNER SAMPLES FOR APPROVAL OR PRODUCT <br />LITERATURE PRIOR TO ORDERING AND OR FABRICATION OF THE FOLLOWING: <br />A. DOORS AND DOOR HARDWARE. <br />B. WIDOWS, STOREFRONT, AND FINISHES. <br />C. ELECTRICAL EQUIPMENT. <br />D. HVAC EQUIPMENT. <br />E. PLUMBING FIXTURES. <br />VERIFICATION OF FIELD MEASUREMENTS OR CONDITIONS SHALL REMAIN THE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />PROJECT CLOSE-OUT <br />UPON COMPLETION OF THE WORK UNDER THIS CONTRACT AND BEFORE FINAL PAYMENT <br />WILL BE MADE, SUBMIT THE FOLLOWING ITEMS TO THE OWNER: <br />A. SUBMIT ONE COPY OF PROJECT RECORD DOCUMENTS TO OWNER REDLINING <br />SIGNIFICANT CHANGES NOT SHOWN ON THE ORIGINAL DOCUMENTS ONTO A SET <br />OF REPRODUCTIONS. <br />B. SUBMIT PROPERLY EXECUTED RELEASE OF LIEN FROM ALL SUBCONTRACTORS <br />AND MATERIAL SUPPLIERS CONTAINING ORIGINAL SIGNATURES AND RAISED <br />NOTARY SEAL. <br />C. CERTIFICATE OF OCCUPANCY FROM APPLICABLE GOVERNMENT AGENCY. <br />D. WARRANTY CERTIFICATES AS CALLED FOR IN INDIVIDUAL SECTIONS <br />OF SPECIFICATIONS. <br />E. LETTER CERTIFYING THE DELIVERY OF ALL KEYS TO THE OWNER. <br />F. LETTER CERTIFYING THAL ALL ITEMS ON THE FINAL PUNCH LIST HAVE BEEN <br />COMPLETED OR CORRECTED. <br />G. LIST OF ALL SUBCONTRACTORS INCLUDING ADDRESSES AND TELEPHONE <br />NUMBERS. <br />H. CLOSEOUT/MAINTENANCE MANUAL DETAILING THE PROCEDUDURES REQUIRED <br />FOR PROPER CARE AND MAINTENANCE OF ALL EQUIPMENT FURNISHED UNDER <br />THE CONTRACT. <br />PAINT A 1'-0 WIDE WHITE STRIPE ON PERIMETER FLOOR IN THE RECEIVING ROOM A <br />MINIMUM OF 2 COATS OF SHERWIN WILLIAMS #7006'EXTRA WHITE' PROGREEN 200 S/G <br />B31 W651 SEMI -GLOSS. <br />SHEETROCK AND FINISH ANY MISSING AREAS BEHIND THE COOLERS ON THE SALES <br />FLOOR. <br />EXTERIOR/ROOF <br />PRESSURE WASH THE FRONT OF THE BUILDING REMOVING ALL DEBRIS. <br />PROVIDE AND FACILITATE A THIRD PARTY INSPECTION OF THE ROOF W/ A WRITTEN <br />REPORT. <br />SEAL ALL HOLES LEADING FROM THE OUTSIDE TO THE INSIDE OF THE SPACE. INCLUDING <br />AROUND ALL PIPES AND WIRE RUNS CAP OFF AND SEAL ANY OPEN PIPES. <br />PROJECT RECORD DOCUMENTS <br />MAINTAIN AT THE JOB SITE ONE COPY OF ALL CONTRACT DOCUMENTS, 'IMPROVEMENTS <br />BY FAMILY DOLLAR', AND 'IMPROVEMENTS BY LANDLORD' DOCUMENTS. <br />SUBMIT PROJECT RECORD DOCUMENTS TO THE ARCHITECT UPON COMPLETION OF THE <br />PROJECT AND PRIOR TO FINAL PAYMENT. <br />FINISHES (PAINT) <br />UNLESS OTHERWISE INDICATED ON THE DRAWINGS, PAINTED SURFACES SHALL RECEIVE <br />THE FOLLOWING COATS AND TYPE OF PAINT. APPLY PAINT BY BRUSH, ROLLER, OR <br />SPRAY, EXCEPT MASONRY SURFACES, CEMENT, PLASTER, OR CONCRETE BLOCK SHALL <br />BE APPLIED BY BRUSH OR APPLIED BY BRUSH OR AIRLESS SPRAY ONLY. <br />A. GYPSUM WALLBOARD (SMOOTH FINISH) <br />ONE (1) COAT SHERWIN WILLIAMS UNDERCOAT <br />TWO (2) COATS PAINT. <br />PRE -PAINTING AND DECORATING: <br />MEET AT THE PROJECT SITE WITH ALL TRADES AND F.D.S. PROJ. MGR. REVIEW <br />CONDITIONS OF SUBSTRATES WITH DRYWALL INSTALLERS PRIOR TO APPLICATION OF <br />ANY PAINTS. <br />REVIEW WITH F.D.S. PROJ. MGR. TO DISCUSS DECORATIVE PAINTING AND ANY <br />CONDITIONS WHICH WOULD POSSIBLY INTERFERE WITH SUCCESSFUL PAINTING AND <br />DECORATING OF THE AREA AS WORK OF THIS SECTION. <br />CLOSED SPEC PROVIDERS: <br />COMPANY: <br />CONTACT: <br />EMS - LIGHTING CONTROL SYSTEM: <br />H.P. 800-518-6630 EXT. 3258 <br />HILL PHOENIX & LIGHTSAT <br />L.S. 800-292-2444 EXT. 221 <br />HVAC UNITS: <br />615-986-1533 (BOB FURSTENBERG) <br />CARRIER <br />HVAC UNITS: <br />405-419-6535 (LISA KUHNS) <br />YORK <br />MOTION SENSOR SYSTEM EXTERIORS: <br />800-933-9831 OR <br />GRAYBAR <br />704-392-1804 <br />SALES FLOOR DOOR: <br />800-828-3655 <br />ELIASON DOORS <br />SECURITY DOOR HARDWARE: <br />704-334-8683 COOK & BOARDMAN <br />ARM -A -DOOR <br />FLOOR PRODUCT FIXTURES: <br />FLOOR PRODUCT FIXTURES <br />LOZIER BY FDS <br />LOZIER BY FDS <br />CHECK OUT FIXTURES: <br />CHECK OUT FIXTURE <br />LYONS BY FDS <br />LYONS BY FDS <br />POWER POLE CONNECTIONS: <br />800-251-2200 OR <br />D & P CUSTOM LIGHTS <br />615-350-7800 <br />INTERIOR LIGHTS: <br />800-933-9831 OR <br />LITHONIA, THRU GRAYBAR ELECTRIC <br />704-392-1804 <br />VINYL COMP. TILE: <br />800-233-3823 (ARMSTRONG) <br />SEE FINISH SCHEDULE <br />SEE FINISH SCHEDULE FOR ALT'S <br />PRO TINT INC: <br />800-553-8693 (CHRIS LUECK) <br />SEE FINISH SCHEDULE <br />POWER POLE LIST: <br />TYPE <br />ITEM # <br />QTY. <br />CHECKOUT -12 <br />8010130 <br />2 <br />UNICRU -16 <br />8529433 <br />1 <br />EAS -16 <br />8520242 <br />1 <br />AISLE - 8' <br />8529487 <br />1 <br />COKE -12' <br />8010130 <br />1 <br />COOLERS -15' <br />8529498 <br />1 <br />SEC. MONITOR <br />8529498 <br />1 <br />NOTE: <br />POWER POLE SHALL BE ORDERED AND <br />INSTALLED FOR STORES THAT OPEN <br />WITH COOLERS & READY FOR COOLERS. <br />PIGTAIL LIST: <br />QTY & ITEM # OF D & P PLUGS <br />2 GREEN (ID4-IG) & 2 BROWN (ID3) <br />1 GREEN (ID44G) <br />1 GREEN (I1344G) <br />1 BROWN (ID3) <br />1 BROWN (ID3) <br />FREEZER & COOLER - BROWN (642FDS005) <br />ADD FOR SINGLE PHASE WHIP IDB-35FT. (624FDS007) <br />MONITOR PLUG BROWN WITH DUPLEX (000MW054F) <br />NOTE: <br />1. ALL POWER IS TO BE DROPPED FROM CEILNG AT LOCATION <br />SPECIFIED ON PLAN. <br />2. ELECTRICAL LOCATIONS MUST BE VERIFIED BY FDS PROJECT <br />MANAGER PRIOR TO INSTALLATION. <br />FIXTURE NOTES: <br />-------------------- <br />RISERS & 6" EXTENDERS <br />PERMITTED THIS AREA <br />L J <br />WALLS RECEIVE 12" <br />EXTENDERS & PEG <br />STORE OPENER TO INSTALL EXTENDERS <br />FOR HBA GONDOLAS. RISER SHELVES <br />TO BE INSTALLED ONLY IF SPECIFIED IN <br />THE INSTRUCTIONS FOUND IN THE STORE <br />OPENING PACKAGE. <br />NOTE: <br />LOCATION OF MAIN CIRCULATION AISLES IS APPROXIMATE <br />AND SUBJECT TO APPROVAL BY TENANT REPRESENTATIVE. <br />PLACEMENT, NUMBER, & TYPE OF FIXTURES ALSO SUBJECT <br />TO APPROVAL BY TENANT REPRESENTATIVE. REFERENCE <br />FIXTURE PLAN FROM FAMILY DOLLAR STORE OFFICE FOR <br />ACTUAL FIXTURE LOCATIONS. <br />ALL FIXTURES ARE SUPPLIED BY TENANT & INSTALLED BY <br />G.C. <br />FLOOR FINISH NOTES: <br />1. G.C. SHALL REMOVE EXISTING AISLE TAPE. <br />2. G.C. SHALL STRIP EXISTING FLOOR WAX. <br />3. G.C. SHALL APPLY 3 COATS OF FLOOR WAX <br />UPON COMPLETION. COORD. SCHEDULE <br />W/ FDS REPRESENTATIVE. <br />UTILITIES <br />NOTE: <br />GC TO PROVIDE TEMPORARY UTILITIES TO SPACE. F.D.S. WILL <br />PROVIDE PERMANENT POWER FOR TRANSFER AT COMPLETION <br />OF CONSTRUCTION AND POSSESSION OF SPACE BY FDS. <br />LANDLORD WORK/NOTES: <br />1. REFER TO 'IMPROVEMENTS BY LANDLORD' SPECS - SEE F.D.S. PROJECT MANAGER <br />2. ANY AND ALL ALTERATIONS TO THE BUILDING ENVELOPE INCLUDING WALL OPENINGS <br />CONCRETE SLAB WORK, ROOF PENETRATIONS, ETC. SHALL BE APPROVED BY THE <br />LANDLORD AND PERFORMED BY LANDLORD APPROVED CONTRACTOR. <br />3. NO STRUCTURAL WORK OF ANY KIND (INCLUDING, BUT NOT LIMITED TO: CUTTING, <br />PATCHING, SPLICING, WELDING, OR SUSPENDING MATERIALS OR ITEMS OF <br />CONSTRUCTION FROM EXISTING STRUCTURAL COMPONENTS) SHALL BE <br />UNDERTAKEN BY GENERAL CONTRACTOR OR HIS SUBCONTRACTORS WITHOUT <br />EXPRESS WRITTEN APPROVAL OF LANDLORD. <br />4. LANDLORD TO INSURE ALL UTILITIES ARE SEPARATELY METERED TO THE F.D.S. <br />DEMISED SPACE. <br />5. REMOVE ALL ASBESTOS CONTAINING MATERIALS AS REQ'D BY CODE. PROVIDE TO <br />FAMILY DOLLAR A CLOSURE LETTER STATING THAT TO THE BEST OF YOUR KNOW- <br />LEDGE THE SPACE IS FREE OF ASBESTOS. <br />6. PLACE EXIST. STOREFRONT, CANOPY/MANSARD IN GOOD REPAIR. MAKE REPAIRS TO <br />ROOF, FLASHING, GUTTERS & DOWNSPOUTS AS REQ'D TO PUT IN WATERTIGHT CONDITION. <br />o <br />o a <br />a) N 0) <br />rn EE <br />.0 <br />� <br />� N 8 <br />\./ co I' v <br />c <br />�Lj W 75 16 <br />a) a) <br />�-- =3 U c <br />�O <br />> <br />OMi N <br />4zrn c <br />,w <br />•�-�i <br />c cD <br />U o0 <br />o -- <br />r- <br />ISSUED FOR REVIEW <br />DATE: <br />ISSUED FOR PERMIT <br />DATE: <br />ISSUED FOR CONSTRUCTION <br />DATE: <br />z <br />0 <br />a <br />U <br />w <br />0 <br />w <br />w <br />a <br />CV <br />0 � <br />U- M <br />u- <br />J <br />m <br />J <br />J � <br />o04 a <br />z coo N <br />DATE: 1.6.11 <br />DRAWN BY: <br />PDL <br />CHECKED BY: <br />PDL <br />SHEET <br />Gwl <br />Imo- u a _ uu 1.1,iE J tJ 11111;1. A i.. _i 1s I I <br />