LIGHTING NOTES:
<br />1. LOCATION OF EXISTING EMERGENCY BACK-UP LIGHTS AND EXIT SIGNS TO
<br />BE VERIFIED IN FIELD. G.C. TO INSPECT ALL EXISTING EMERGENCY
<br />BACK-UP AND EXIT SIGNS/LIGHTS AND REPLACE AS NECESSARY.
<br />2. LED INCANDESCENT EXIT SIGNS W/ NI -CAD BATTERY BACK-UP (LITHONIA,
<br />CAT. # LQMSW3Rl20ELN OR EQUAL).
<br />3. EMERGENCY LIGHTING UNITS W/ 6V BATTERY BACK-UP AND FULL RANGE
<br />ADJUSTABLE HEAD -LAMPS (LITHONIA, CAT. # ELM2 OR EQUAL).
<br />4. 5AW WEDGE -BASE TUNGSTEN LAMP EMERGENCY LIGHTS ("QUANTUM"
<br />CONTEMPORARY POLYCARBONATE EMERGENCY LIGHTING UNITS) W/ 6V
<br />BATTERY BACK-UP IN OFFICES, LOUNGE, AND REST ROOMS AS INDICATED
<br />ON PLANS. (LITHONIA, CAT. # HQMSMR120 OR EQUAL).
<br />5. EXIT SIGN / EMERGENCY LIGHT COMBO. W/ NI -CAD / 6V BATTERY BACK-UP
<br />AND FIXED HEAD -LAMPS. (LITHONIA CAT. # HQMSW2R120 OR EQUAL).
<br />6. ALL NEW LIGHT FIXTURES TO UTILIZE EXISTING WHIPS, JUNCTION BOXES, &
<br />CIRCUITS. FIXTURES ARE ONLY TO BE REPLACED.
<br />7. CONNECT NEW EMERGENCY LIGHTS/EXIT SIGNS TO NEAREST CIRCUIT.
<br />8. LIGHT FIXTURES DESIGNATED WITH NL TO BE DIRECT -WIRED FOR NIGHT
<br />LIGHT (TYPICAL).
<br />SCOPE OF WORK (CEILING) :
<br />1. PATCH CEILING GRID AND TILE TO PROVIDE A UNIFORM CEILING WHERE
<br />WALLS WERE REMOVED.
<br />2. PATCH CEILING GRID AND TILE TO PROVIDE A UNIFORM CEILING WHERE
<br />NEW WALLS WERE CONSTRUCTED.
<br />3. SPOT REPLACE DAMAGED OR STAINED CEILING TILES.
<br />4. REMOVE ANY EXCESS WIRES, STRINGS, CLIPS, ETC. FROM CEILING.
<br />5. REPLACE ALL SAGGING CEILING TILES.
<br />(AFTER FIELD SURVEY, REPLACE ALL CEILING TILES)
<br />SPRINKLER (IF SO EQUIPPED) NOTES:
<br />ALL MODIFICATIONS, ADDITIONS, REPAIRS, OR RELOCATION OF THE EXISTING
<br />SPRINKLER SYSTEM SHALL BE PERFORMED BY LANDLORD APPROVED
<br />(AND LICENSED CONTRACTOR. SAID
<br />CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING SHOP DRAWINGS TO
<br />LANDLORD AND BUILDING DEPARTMENT FOR APPROVAL.
<br />SPRINKLER CONTRACTOR TO ADD, MOVE OR RELOCATE HEADS AS REQUIRED.
<br />REFER TO ORIGINAL PERMITTED CONSTRUCTION DRAWINGS FOR LOCATION OF EXISTING
<br />SPRINKLER HEADS (OR VERIFY IN FIELD)
<br />CEILING OPEN TO ROOF NOTE:
<br />1. THE CEILING AREA ABOVE THE FIELD COLOR TILE HAS THE CEILING TILE AND GRID
<br />REMOVED TO EXPOSE MECHANICAL DUCTWORK AND ROOF INSULATION AND ALL
<br />EXPOSED ELEMENTS ABOVE THE TYPICAL CEILING GRID. THE MECHANICAL ENGINEER
<br />WILL CALCULATE THE ENERGY LOAD REQUIRED TO HEAT AND COOL THE VOLUME, AND
<br />RECOMMEND R-VALUES TO PASS THE COM-CHECK FORM REQUIREMENTS OF EACH
<br />LOCATIONS.
<br />ROOM FINISH SCHEDULE:
<br />CEILING LEGEND:
<br />A
<br />B
<br />O
<br />r---------�
<br />rr--------��
<br />I!`
<br />"144,
<br />LANDLORD NOTES:
<br />EXIST. GYP BOARD CEILING @ 8'-0" +/-
<br />AFF TO BE REMOVED
<br />EXISTING 2' X 4' SUSPENDED CEILING
<br />GRID - TO BE REMOVED
<br />EXISTING GYP BOARD SOFFIT
<br />TO BE REMOVED
<br />SURFACE -MOUNT STRIP AND RECESSED
<br />FLUORESCENT LIGHT FIXTURES
<br />EXISTING LIGHT FIXTURE
<br />TO BE REMOVED
<br />RETURN AIR HVAC DIFFUSERS
<br />SUPPLY AIR HVAC DIFFUSERS
<br />1. ANY AND ALL ALTERATIONS TO THE BUILDING ENVELOPE INCLUDING WALL
<br />OPENINGS, CONCRETE SLAB WORK, ROOF PENETRATIONS, ETC. SHALL BE
<br />APPROVED BY THE LANDLORD AND PERFORMED BY LANDLORD APPROVED
<br />CONTRACTOR.
<br />2. NO STRUCTURAL WORK OF ANY KIND (INCLUDING, BUT NOT LIMITED TO: CUTTING,
<br />PATCHING, SPLICING, WELDING, OR SUSPENDING MATERIALS OR ITEMS OF
<br />CONSTRUCTION FROM EXISTING STRUCTURAL COMPONENTS) SHALL BE UNDERTAKEN
<br />BY GENERAL CONTRACTOR OR HIS SUBCONTRACTORS WITHOUT EXPRESS WRITTEN
<br />APPROVAL OF THE LANDLORD.
<br />3. ALL CUTTING, PATCHING, AND MAINTENANCE/REPAIR OF EXISTING ROOF SHALL BE
<br />APPROVED BY LANDLORD AND EXECUTED BY LANDLORD'S GENERAL
<br />CONTRACTOR (PRIOR TO CONSTRUCTION) AND SHALL MATCH BUILDING STANDARD
<br />ROOFING DETAILS.
<br />ROOM NAME
<br />FLOOR
<br />BASE
<br />WALL
<br />CEILING
<br />REMARKS
<br />MATERIAL
<br />MATERIAL
<br />MATERIAL
<br />MATERIAL
<br />FIN.
<br />HEIGHT
<br />co
<br />w
<br />coZ
<br />z
<br />O O
<br />w M
<br />z
<br />w
<br />rr
<br />t
<br />-
<br />O O
<br />aZ
<br />wm
<br />~
<br />z
<br />s
<br />oU-
<br />z
<br />z
<br />U
<br />a
<br />m
<br />O
<br />a
<br />-a\o
<br />z
<br />H wp
<br />Q
<br />z z
<br />an d
<br />C9
<br />m
<br />N o
<br />rr�
<br />O
<br />w w
<br />ri o
<br />O
<br />X
<br />rl
<br />o
<br />z
<br />Qco
<br />ww
<br />z
<br />0U
<br />z
<br />a
<br />O
<br />d
<br />p
<br />w
<br />>
<br />W
<br />Lo
<br />LL
<br />u�
<br />cwn to
<br />1
<br />2
<br />13
<br />4
<br />1
<br />1
<br />2
<br />3
<br />4
<br />5
<br />6
<br />1
<br />SALES AREA
<br />•
<br />OPEN
<br />CLG OPEN TO STRUCTURE ABOVE. VERIFY NEW FINISHES WITH TENANT.
<br />STOCK
<br />•
<br />•
<br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT.
<br />WOMENS
<br />•
<br />8'-0" +/-
<br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT.
<br />MENS
<br />•
<br />T-0" +/-
<br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT.
<br />OFFICE
<br />•
<br />8'-0" +/-
<br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT.
<br />ELECTRIC
<br />•
<br />•
<br />OPEN
<br />CLG OPEN TO STRUCTURE ABOVE. VERIFY NEW FINISHES WITH TENANT.
<br />BREAK
<br />VERIFY LOCATION, FIXTURES, AND FINISHES W/ F.D.S. PM
<br />***
<br />COLUMNS/MEZZANINE BEAM
<br />ALL FINAL COLOR AND FINISH SELECTIONS SHALL BE APPROVED,
<br />IN WRITING, BY THE TENANT REPRESENTATIVE PRIOR TO PURCHASE AND INSTALLATION.
<br />GC TO REFER TO'THE SCOPE OF WORK' ON THE DRAWINGS
<br />AND F.D.S.'S HANDOUTS
<br />GC TO VERIFY/CONFIRM QUANTITY AND LOCATION OF ALL
<br />FINISHES TO INCLUDE BASE
<br />J-BOX MOUNTED BY E.C.
<br />TO BOTTOM OF BAR
<br />JOIST/PURLIN.
<br />ELECTRICAL WHIP W/
<br />PIGTAIL CONNECTOR
<br />PROVIDED BY E.C. SEE
<br />SCHEDULE, THIS DRAWING.
<br />2 CHANNEL POWER POLE SUPPLIED
<br />AND INSTALLED BY FDS STORE
<br />OPENING TEAM. FDS CABLING
<br />CONTRACTOR SHALL RUN CAT-5
<br />CABLES DOWN DATA CHANNEL
<br />OF POWER POLE.
<br />CHECKOUT
<br />COUNTER
<br />ELECTRICAL WHIP W/ PIG TAIL
<br />CONNECTOR FACTORY INSTALLED
<br />AS PART OF POWER POLE
<br />ASSEMBLY. FDS OPENING TEAM
<br />SHALL MAKE FINAL CONNECTION
<br />OF PIGTAIL CONNECTORS.
<br />ALL THREAD ROD
<br />UNI-STRUT AS REQUIRED
<br />ATTACHED TO STRUCTURE.
<br />"U" BOLT
<br />ATTACH POWER POLE BOTTOM
<br />BRACKET TO COUNTER (OR
<br />FLOOR).
<br />POVNER POLE I NSTALLAT I ON SETA I L
<br />SCALE : NTS
<br />ROOF STRUCTURE BY METAL BUILDING
<br />MANUFACTURER
<br />(4) ALL TREAD RODS ATTACHED TO (2)
<br />PARALLEL UNISTRUT SUPPORTS (NOT
<br />SHOWN) BOLTED TO STRUCTURE
<br />ABOVE. BY G.C.
<br />2 X 2 X A" TUBE STEEL THROUGH BOLTED
<br />AT MIN. TWO ROOF PURLINS
<br />DOOR SCHEDULE:
<br />DOORS
<br />z
<br />FRAMES
<br />m
<br />o Q w
<br />m
<br />=W
<br />oD
<br />z
<br />m
<br />m Q w
<br />I- m
<br />' W
<br />❑D
<br />z
<br />o m
<br />= Q w
<br />m m
<br />W W�
<br />Ir0D
<br />m z
<br />HD.WARE
<br />REMARKS
<br />DOOR
<br />NO.
<br />SIZE
<br />nw
<br />¢
<br />W
<br />=
<br />cn
<br />z
<br />Q
<br />-J
<br />w
<br />m
<br />:
<br />OVERALL SIZE
<br />a
<br />z
<br />Q
<br />w
<br />WIDTH
<br />HEIGHT
<br />TH.
<br />WIDTH
<br />HEIGHT
<br />DEPTH
<br />-
<br />-
<br />,
<br />2
<br />3'-0"
<br />7'-0"
<br />1 3/8"
<br />1
<br />WD
<br />PAIN
<br />"
<br />Y-4"
<br />7'-2"
<br />1
<br />PAINT
<br />HC MTL
<br />7
<br />DOOR UNDERCUT 1" (TYP), CLOSURE DEVICE
<br />3
<br />(2) X-0"
<br />7'-0"
<br />3
<br />MTL
<br />PAIN
<br />"
<br />6'-4"
<br />7'-2"
<br />2
<br />PAINT
<br />HC MTL
<br />3
<br />ELIASON DOOR MODEL #LWP3-PR72X84FD
<br />4
<br />X-0
<br />7'-0"
<br />1 3/8"
<br />MTL
<br />PAIN
<br />3-3
<br />'-4"
<br />7'-2"
<br />PAINT
<br />HC MTL
<br />5
<br />180 DEGREE PEEPSITE AT 5'-0 AFF
<br />DOOR NOTES:
<br />1. DOORS TO COMPLY W/ NCSBC ACCESSIBILITY CODE.
<br />2. ALL WOOD (WD) DOORS TO BE SOLID CORE, BIRCH VENEER.
<br />3. IC MET = INSULATED CORE, METAL DOOR.
<br />4. FIRE RATED DOORS SHALL HAVE RATED FRAMES AND HARDWARE
<br />TO MATCH. ALL SHALL CARRY REQUIRED UL RATING LABEL.
<br />5. VERIFY ALL DOOR FINISHES WITH OWNER.
<br />GRAPHIC LEGEND:
<br />IMMOM NEW WALL (MATERIAL INDICATION MAY VARY)
<br />EXISTING CONSTRUCTION
<br />TO BE REMOVED
<br />EXISTING WALL TO REMAIN
<br />OPARTITION TYPE -SEE KEY
<br />0 PLAN NOTE
<br />NOTE:
<br />SEE ELECTRICAL DRAWINGS BY SABER ENGINEERING FOR POWER AND
<br />LIGHTING DETAILS.
<br />LIGHT FIXTURE SCHEDULE
<br />LTR
<br />MANUFACTURER
<br />LAMPS
<br />MOUNTING
<br />DESCRIPTION
<br />A
<br />BY OWNER
<br />4-32W T8
<br />CHAIN
<br />4-LAMP 8'
<br />B
<br />BY OWNER
<br />2-32W T8
<br />CHAIN
<br />2-LAMP 4'
<br />C
<br />BY OWNER
<br />1-175W-MH
<br />WALL
<br />175W MH WALLPAK
<br />EXEM
<br />BY OWNER
<br />INCLUDED
<br />WALL
<br />EXIT/EMERGENCY LIGHT
<br />EX
<br />BY OWNER
<br />INCLUDED
<br />WALL
<br />EXIT LIGHT
<br />EM
<br />BY OWNER
<br />INCLUDED
<br />WALL
<br />EMERGENCY LIGHT
<br />RESTROOM NOTES:
<br />1. LAYOUT OF RESTROOM FACILITIES SHALL COMPLY WITH ALL APPLICABLE
<br />STATE AND LOCAL CODES, INCLUDING ALL ADA REQUIREMENTS. SUBMIT
<br />ANY MODIFIED LAYOUTS TO FAMILY DOLLAR FOR THEIR REVIEW AND
<br />APPROVAL.
<br />2. TOILETS SHALL BE EQUIPPED W/ THE FOLLOWING ACCESSIBLE FOR EACH.
<br />1 EA. 18" X 24" FRAMED WALL MIRROR CONCEALED MOUNTING OVER EACH
<br />LAVATORY. INSTALL W/ BASE @ 40" AFF.
<br />1 EA. TOILET TISSUE HOLDER - BRADLEY MODEL "5054" 18 GA CHROME PLATED
<br />STEEL OR APPROVED EQUAL. INSTALL W/ CENTER LINE @ 24" AFF.
<br />1 EA. HOOK - BRADLEY MODEL 931 MOUNTED TO DOOR FACE OR APPROVED
<br />EQUAL. INSTALL HOOK @ 4'-6" AFF.
<br />1 EA. 1-1/4" X 36" & 42" S.S. CODE APPROVED GRAB BARS WALL (OR FLOOR
<br />MOUNTED) AS REQUIRED. INSTALL GRAB BARS @ 34" - 36" AFF.
<br />1 EA. ELEC. HAND DRYER - INSTALL WITH OPERATING MECHANISM @ 48" AFF.
<br />BY ELECTRIC AIRE MODEL LE-1. DRYER LOCATED ON SIDE WALL TO LAV.
<br />1 EA. CODE APPROVED ROOM IDENTIFICATION SIGN INSTALLED ADJACENT TO
<br />STRIKE JAMB/LATCH SIDE OF DOOR W/ HORIZONTAL CENTERLINE @ 60" AFF.
<br />2 EA. TOILET SHELF - 24" L X 8" D - WHITE - INSTALL W/ SHELF @ 46" AFF.
<br />USE PREFINISHED WHITE ADJUSTABLE SHELF STANDARDS AND SUPPORTS.
<br />3. INSTALL CONTINUOUS FIRE RETARDANT TREATED 2 X 6 BLOCKING BETWEEN STUDS FOR
<br />ALL HANDRAILS, GRAB BARS, FIXTURES, BRACKETS, ACCESSORIES, CABINETRY, AND MISC.
<br />SPECIAL TIES AS REQURIED, UNLESS NOTED OTHERWISE.
<br />4. USE 1/2" MOISTURE RESISTANT GWB (GREENBOARD) FOR RESTROOM WALLS AND TYP
<br />FOR GWB CEILINGS.
<br />5. DOOR HARDWARE MUST BE MOUNTED BETWEEN 34" (MIN.) AND 48" (MAX.)
<br />NOTE:
<br />MONITOR NOT INSTALLED IN
<br />ALL STORE LOCATIONS. LL OR G.C.
<br />TO VERIFY WITH FAMILY DOLLAR
<br />PROJECT MANAGER IF MONITOR WILL
<br />BE REQUIRED PER LOCAL CRIME
<br />FACTORS. MONITOR TO BE INSTALLED
<br />BY OTHERS.
<br />STEEL PLATES PROVIDED BY BRACKET
<br />MANUFACTURER. THROUGH BOLTED TO EA. SIDE OF
<br />TUBE STEEL AS SHOWN. USE LOCK WASHERS TOP AND
<br />BOTTOM, RETAINING COLLAR TOP AND BOTTOM -
<br />LOCATE 18' +/- BACK FROM FRONT OF STORE ON
<br />CENTERLINE OF ENTRY DOORS. SEE FIXTURE PLAN
<br />FOR EXACT LOCATION.
<br />SAFETY CABLE ATTACHED TO ROOF STRUCTURE
<br />ABOVE. VERIFY W/ MFR. APPROPRIATE CABLE
<br />STRENGTH FOR MONITOR ASSEMBLY WEIGHT. BY G.C.
<br />LCD CEILING MOUNT MONITOR BRACKET BY CLINTON
<br />ELECTRONICS - MODEL #CE-CM-8-6 FOR MAX 5'-6"
<br />EXTENSION AND CE-CM-L-12 FOR MAX 1 V-6"
<br />EXTENSION. VERIFY FINAL FIXTURE PLAN PRIOR TO
<br />ORDERING. CALL 800-873-2580 EXT. 1404 FOR INFO -
<br />BOTTOM OF MONITOR TO BE 8'-6" A.F.F. MONITOR
<br />SUPPLIED BY FDS. INSTALL SAFETY CABLE AS
<br />INSTRUCTED BY MANUFACTURER.
<br />MONITOR HANGING nr:TA I L
<br />SCALE: NTS
<br />3/4" FIRE TREATED PLYWOOD
<br />1/2" MR GWB
<br />3-5/8 MTL. STUD
<br />CONT. 22 MSG GALV.
<br />STEEL TOP TRACK
<br />FRP TO 4'-0 AFF
<br />FRP TO 4'-0 AFF
<br />1/2" MR GWB EA. SIDE
<br />20 MSG. 3-5/8 MTL. STUD @ 16" O.C.
<br />CONT. 22 MSG GALV. STEEL BASE
<br />TRACK FASTENED TO SLAB W/
<br />STEEL FASTENERS 24" O.C. MAX
<br />SECTION
<br />SCALE: 3/4" - 1'-0"
<br />HARDWARE NOTES:
<br />A. ALL EXIT DOORS (EXCEPT STOREFRONT) SHALL HAVE ARM -A -DOOR HDWARE
<br />B. PROVIDE STOPS ON ALL DOORS, USE WALL STOPS WHERE AVAILABLE,
<br />& FLOOR STOPS WHERE NECESSARY.
<br />C. ALL HARDWARE SHALL MEET THE REQUIREMENTS OF THE ADA, ANSI 117.1, AND VOL. 1-C
<br />D. CLOSERS SHALL BE COMMERCIAL GRADE.
<br />E. VERIFY HARDWARE AND DOOR TYPES W/ F.D.S. PRIOR TO PLACING ORDER.
<br />HARDWARE SCHEDULE:
<br />CONTRACTOR TO INSPECT EXISTING DOORS & VERIFY W/ TENANT POSSIBLE REUSE BEFORE ORDERING HARDWARE
<br />HARDWARE GROUP
<br />DESCRIPTION
<br />FINISH
<br />MANUFACTURER
<br />HARDWARE # 1 (-)
<br />DOORS (-) STOREFRONT
<br />(1) LOCKSET EACH
<br />EXT KEY LOCK W/ INTERIOR THUMB TURN
<br />PER TENANT
<br />PER TENANT
<br />(3) HINGES EACH
<br />CONTINUOUS HINGES IN LIEU OF PIVOTS
<br />PER TENANT
<br />PER TENANT
<br />(1) THRESHOLD EACH
<br />BRUSH STYLE DOOR SWEEP C380CLA06BL
<br />" "
<br />SEALEZE (OR EQUAL)
<br />(1) CLOSURE EACH
<br />KAWNEER "HUSKY 11" W/ 105 DEGREE HOLD OPEN
<br />PER TENANT
<br />KAWNEER (OR EQUAL)
<br />HARDWARE # 2 (-)
<br />DOORS (-) EXT/FRIEGHT RECEIVING
<br />NO EXTERIOR KNOBS OR HANDLES
<br />(1) LOCKSET EACH
<br />"ARM -A -DOOR" A101-030
<br />ARM -A -DOOR (OR EQUAL)
<br />CONTACT: 407-291-1443 FOR INFO
<br />(3) HINGES EACH
<br />11291 1/2" PR (4 1/2" X 41/2" USP)
<br />US26D
<br />HAGER (OR EQUAL)
<br />(1) FLOOR STOP EACH
<br />" "
<br />" " (OR EQUAL)
<br />(1) CLOSER EACH
<br />YALE 4020
<br />PER TENANT
<br />YALE (OR EQUAL)
<br />(1) WEATHERSTRIP EACH
<br />303ASW/S3
<br />" "
<br />PEMKO (OR EQUAL)
<br />(1) THRESHOLD EACH
<br />BRUSH STYLE DOOR SWEEP C380SLA06BL
<br />" "
<br />SEALEZE (OR EQUAL)
<br />(1) DOOR VIEWER EACH
<br />180 DEGREE @ 5' AFF
<br />PER TENANT
<br />PER TENANT (OR EQUAL)
<br />(1) KICK PLATE EACH
<br />PER TENANT
<br />PER TENANT
<br />PER TENANT (OR EQUAL)
<br />HARDWARE # 3 (1)
<br />DOORS (D) SALES SUPPORT
<br />"ELIASON" (OR EQUAL)
<br />DBL SWING IMPACT RESISTANT DOORS
<br />HARDWARE PER MANUFACTURER
<br />MODEL LWP-3 FOR INFOR & PRICE
<br />CONTACT MANUR AT 800-828-3655
<br />HARDWARE # 4 (1)
<br />DOORS (A) STOCKISALES
<br />(1) LOCKSET EACH
<br />A105-LEV-626 (KEYED DEADBOLT W/ THUMB TURN)
<br />SCHLAGE A10S-LEV-626
<br />PER TENANT
<br />SCHLAGE (OR EQUAL)
<br />(3) HINGES EACH
<br />1129 1 1/2" PR (4 1/2" X 41/2" USP)
<br />US26D
<br />HAGER (OR EQUAL)
<br />(1) CLOSER EACH
<br />YALE 4020
<br />PAINT TO MATCH FRAME
<br />YALE (OR EQUAL)
<br />(2) KICK PLATE EACH
<br />BOTH SIDES
<br />PAINT TO MATCH FRAME
<br />HAGER (OR EQUAL)
<br />(1) FLOOR STOP
<br />243F 26D
<br />HAGER (OR EQUAL)
<br />HARDWARE # 5 (1)
<br />DOOR (B) OFFICE
<br />(1) LOCKSET EACH
<br />A10S-LEV-626
<br />PER TENANT
<br />HAGER (OR EQUAL)
<br />(1) CLOSER EACH
<br />YALE 4020
<br />US26D
<br />YALE (OR EQUAL)
<br />(1) KICK PLATE EACH
<br />EACH SIDE
<br />PAINT TO MATCH FRAME
<br />HAGER (OR EQUAL)
<br />(1) DOOR VIEWER
<br />DS-1000
<br />PER TENANT
<br />PER TENANT (OR EQUAL)
<br />(3) HINGES EACH
<br />11291 1/2" PR (4 1/2" X 41/2" USP)
<br />US26D
<br />HAGER (OR EQUAL)
<br />HARDWARE # 6 (1)
<br />DOOR (B) OFFICE
<br />(1) LOCKSET EACH
<br />CLASSRM. SET FINISH TO MATCH OTHER HD.WARE
<br />PER TENANT
<br />HAGER (OR EQUAL)
<br />(3) HINGES EACH
<br />1129 1 1/2" PR (4 1/2" X 41/2" USP)
<br />US26D
<br />HAGER (OR EQUAL)
<br />HARDWARE # 7 (2)
<br />DOOR (C) RESTROOM
<br />(1) LOCKSET EACH
<br />SCHLAGE A40S-LEV-626
<br />" "
<br />HAGER (OR EQUAL)
<br />(3) HINGES EACH
<br />1129 1 1/2" PR (4 1/2" X 41/2" USP)
<br />US26D
<br />HAGER (OR EQUAL)
<br />(1) FLOOR STOP EACH
<br />243F 26D
<br />' "
<br />HAGER (OR EQUAL)
<br />(1) CLOSER EACH
<br />YALE 4020
<br />PAINT TO MATCH FRAME
<br />YALE (OR EQUAL)
<br />HARDWARE # 8 (-)
<br />DOOR (-) SALES AREA EM. EXIT
<br />(1) LOCKSET EACH
<br />"ARM -A -DOOR" A101-030
<br />��
<br />ARM -A -DOOR �OR EQUAL)
<br />CONTACT: 407-291-1443 OR INFO
<br />(3) HINGES EACH
<br />1129 1 1/2" PR (4 1/2" X 41/2" USP)
<br />US26D
<br />HAGER (OR EQUAL)
<br />(1) THRESHOLD EACH
<br />BRUSH STYLE DOOR SWEEP C380CLA06BL
<br />" "
<br />SEALEZE (OR EQUAL)
<br />(1) CLOSER EACH
<br />YALE 4020
<br />PAINT TO MATCH FRAME
<br />YALE (OR EQUAL)
<br />HARDWARE NOTES:
<br />1. VERIFY EXISTING HARDWARE W/ TENANT REP. & SUPPLEMENT WITH NEW HARDWARE AS SPECIFIED. VERIFY HARDWARE REQUIREMENTS WITH TENANT.
<br />2. ALL SELECTED HARDWARE AND THRESHOLDS TO COMPLY WITH ALL NATIONAL, STATE AND LOCAL ADA CODES AND REQUIREMENTS.
<br />VERIFY ACCESSIBILITY COMPLIANCE WITH MANUFACTURER.
<br />3. G.C. TO INSPECT EXISTING EXIT DOORS FOR PANIC/ALARM HARDWARE. INSTALL NEW ALARM DEVICE (ARM -A -DOOR MODEL NO. A101-030),
<br />PANIC ALARM W/ LOCK AS NECESSARY.
<br />4. EXISTING RECEIVING/EXIT DOOR TO HAVE A DOOR TO HAVE A DOOR VIEWER BY DOORSCOPE INSTALLED AS WELL AS PANIC HARDWARE (VERIFY W/ LANDLORD).
<br />5. REUSE ANY EXISTING DOORS THAT MEET W/ THE TENANT REPRESENTATIVE'S APPROVAL.
<br />6. ALL EXTERIOR DOORS SHOULD BE BETWEEN 10 TO 15 LBS. OF FORCE.
<br />7. ALL INTERIOR DOORS SHOULD BEAT 5 LBS. OF FORCE.
<br />o
<br />ocj o
<br />(� NN0 pp
<br />U) N S U
<br />J n Gc
<br />W oti-6
<br />(Dcv�a3
<br />=Ucf)
<br />ca
<br />� Q'S �
<br />( j co
<br />^V Lvrn o
<br />cu
<br />O .0ci
<br />Uco 0
<br />C:)
<br />ISSUED FOR REVIEW
<br />DATE:
<br />ISSUED FOR PERMIT
<br />DATE:
<br />IISSUED FOR CONSTRUCTION'
<br />DATE:
<br />w
<br />Q
<br />0
<br />z
<br />O
<br />a
<br />U
<br />U)
<br />w
<br />0
<br />w
<br />Vt' ,, �" w
<br />0
<br />. Z J_
<br />e
<br />Y
<br />Z
<br />��
<br />lwm
<br />_V
<br />® _j
<br />ci
<br />Q
<br />U)
<br />J
<br />Q
<br />W
<br />04 Q
<br />0 Lo 'n
<br />LL cMM U )
<br />ou W
<br />LJL J J
<br />00 J
<br />D Q=
<br />3: o_
<br />o CN
<br />Z � N U)
<br />DATE: 1.6.11
<br />DRAWN BY: PDL
<br />CHECKED BY: PDL
<br />SHEET
<br />A�3
<br />ice- r ri 77