Laserfiche WebLink
LIGHTING NOTES: <br />1. LOCATION OF EXISTING EMERGENCY BACK-UP LIGHTS AND EXIT SIGNS TO <br />BE VERIFIED IN FIELD. G.C. TO INSPECT ALL EXISTING EMERGENCY <br />BACK-UP AND EXIT SIGNS/LIGHTS AND REPLACE AS NECESSARY. <br />2. LED INCANDESCENT EXIT SIGNS W/ NI -CAD BATTERY BACK-UP (LITHONIA, <br />CAT. # LQMSW3Rl20ELN OR EQUAL). <br />3. EMERGENCY LIGHTING UNITS W/ 6V BATTERY BACK-UP AND FULL RANGE <br />ADJUSTABLE HEAD -LAMPS (LITHONIA, CAT. # ELM2 OR EQUAL). <br />4. 5AW WEDGE -BASE TUNGSTEN LAMP EMERGENCY LIGHTS ("QUANTUM" <br />CONTEMPORARY POLYCARBONATE EMERGENCY LIGHTING UNITS) W/ 6V <br />BATTERY BACK-UP IN OFFICES, LOUNGE, AND REST ROOMS AS INDICATED <br />ON PLANS. (LITHONIA, CAT. # HQMSMR120 OR EQUAL). <br />5. EXIT SIGN / EMERGENCY LIGHT COMBO. W/ NI -CAD / 6V BATTERY BACK-UP <br />AND FIXED HEAD -LAMPS. (LITHONIA CAT. # HQMSW2R120 OR EQUAL). <br />6. ALL NEW LIGHT FIXTURES TO UTILIZE EXISTING WHIPS, JUNCTION BOXES, & <br />CIRCUITS. FIXTURES ARE ONLY TO BE REPLACED. <br />7. CONNECT NEW EMERGENCY LIGHTS/EXIT SIGNS TO NEAREST CIRCUIT. <br />8. LIGHT FIXTURES DESIGNATED WITH NL TO BE DIRECT -WIRED FOR NIGHT <br />LIGHT (TYPICAL). <br />SCOPE OF WORK (CEILING) : <br />1. PATCH CEILING GRID AND TILE TO PROVIDE A UNIFORM CEILING WHERE <br />WALLS WERE REMOVED. <br />2. PATCH CEILING GRID AND TILE TO PROVIDE A UNIFORM CEILING WHERE <br />NEW WALLS WERE CONSTRUCTED. <br />3. SPOT REPLACE DAMAGED OR STAINED CEILING TILES. <br />4. REMOVE ANY EXCESS WIRES, STRINGS, CLIPS, ETC. FROM CEILING. <br />5. REPLACE ALL SAGGING CEILING TILES. <br />(AFTER FIELD SURVEY, REPLACE ALL CEILING TILES) <br />SPRINKLER (IF SO EQUIPPED) NOTES: <br />ALL MODIFICATIONS, ADDITIONS, REPAIRS, OR RELOCATION OF THE EXISTING <br />SPRINKLER SYSTEM SHALL BE PERFORMED BY LANDLORD APPROVED <br />(AND LICENSED CONTRACTOR. SAID <br />CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING SHOP DRAWINGS TO <br />LANDLORD AND BUILDING DEPARTMENT FOR APPROVAL. <br />SPRINKLER CONTRACTOR TO ADD, MOVE OR RELOCATE HEADS AS REQUIRED. <br />REFER TO ORIGINAL PERMITTED CONSTRUCTION DRAWINGS FOR LOCATION OF EXISTING <br />SPRINKLER HEADS (OR VERIFY IN FIELD) <br />CEILING OPEN TO ROOF NOTE: <br />1. THE CEILING AREA ABOVE THE FIELD COLOR TILE HAS THE CEILING TILE AND GRID <br />REMOVED TO EXPOSE MECHANICAL DUCTWORK AND ROOF INSULATION AND ALL <br />EXPOSED ELEMENTS ABOVE THE TYPICAL CEILING GRID. THE MECHANICAL ENGINEER <br />WILL CALCULATE THE ENERGY LOAD REQUIRED TO HEAT AND COOL THE VOLUME, AND <br />RECOMMEND R-VALUES TO PASS THE COM-CHECK FORM REQUIREMENTS OF EACH <br />LOCATIONS. <br />ROOM FINISH SCHEDULE: <br />CEILING LEGEND: <br />A <br />B <br />O <br />r---------� <br />rr--------�� <br />I!` <br />"144, <br />LANDLORD NOTES: <br />EXIST. GYP BOARD CEILING @ 8'-0" +/- <br />AFF TO BE REMOVED <br />EXISTING 2' X 4' SUSPENDED CEILING <br />GRID - TO BE REMOVED <br />EXISTING GYP BOARD SOFFIT <br />TO BE REMOVED <br />SURFACE -MOUNT STRIP AND RECESSED <br />FLUORESCENT LIGHT FIXTURES <br />EXISTING LIGHT FIXTURE <br />TO BE REMOVED <br />RETURN AIR HVAC DIFFUSERS <br />SUPPLY AIR HVAC DIFFUSERS <br />1. ANY AND ALL ALTERATIONS TO THE BUILDING ENVELOPE INCLUDING WALL <br />OPENINGS, CONCRETE SLAB WORK, ROOF PENETRATIONS, ETC. SHALL BE <br />APPROVED BY THE LANDLORD AND PERFORMED BY LANDLORD APPROVED <br />CONTRACTOR. <br />2. NO STRUCTURAL WORK OF ANY KIND (INCLUDING, BUT NOT LIMITED TO: CUTTING, <br />PATCHING, SPLICING, WELDING, OR SUSPENDING MATERIALS OR ITEMS OF <br />CONSTRUCTION FROM EXISTING STRUCTURAL COMPONENTS) SHALL BE UNDERTAKEN <br />BY GENERAL CONTRACTOR OR HIS SUBCONTRACTORS WITHOUT EXPRESS WRITTEN <br />APPROVAL OF THE LANDLORD. <br />3. ALL CUTTING, PATCHING, AND MAINTENANCE/REPAIR OF EXISTING ROOF SHALL BE <br />APPROVED BY LANDLORD AND EXECUTED BY LANDLORD'S GENERAL <br />CONTRACTOR (PRIOR TO CONSTRUCTION) AND SHALL MATCH BUILDING STANDARD <br />ROOFING DETAILS. <br />ROOM NAME <br />FLOOR <br />BASE <br />WALL <br />CEILING <br />REMARKS <br />MATERIAL <br />MATERIAL <br />MATERIAL <br />MATERIAL <br />FIN. <br />HEIGHT <br />co <br />w <br />coZ <br />z <br />O O <br />w M <br />z <br />w <br />rr <br />t <br />- <br />O O <br />aZ <br />wm <br />~ <br />z <br />s <br />oU- <br />z <br />z <br />U <br />a <br />m <br />O <br />a <br />-a\o <br />z <br />H wp <br />Q <br />z z <br />an d <br />C9 <br />m <br />N o <br />rr� <br />O <br />w w <br />ri o <br />O <br />X <br />rl <br />o <br />z <br />Qco <br />ww <br />z <br />0U <br />z <br />a <br />O <br />d <br />p <br />w <br />> <br />W <br />Lo <br />LL <br />u� <br />cwn to <br />1 <br />2 <br />13 <br />4 <br />1 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />1 <br />SALES AREA <br />• <br />OPEN <br />CLG OPEN TO STRUCTURE ABOVE. VERIFY NEW FINISHES WITH TENANT. <br />STOCK <br />• <br />• <br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT. <br />WOMENS <br />• <br />8'-0" +/- <br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT. <br />MENS <br />• <br />T-0" +/- <br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT. <br />OFFICE <br />• <br />8'-0" +/- <br />VERIFY CLG HEIGHT IN FIELD. VERIFY NEW FINISHES WITH TENANT. <br />ELECTRIC <br />• <br />• <br />OPEN <br />CLG OPEN TO STRUCTURE ABOVE. VERIFY NEW FINISHES WITH TENANT. <br />BREAK <br />VERIFY LOCATION, FIXTURES, AND FINISHES W/ F.D.S. PM <br />*** <br />COLUMNS/MEZZANINE BEAM <br />ALL FINAL COLOR AND FINISH SELECTIONS SHALL BE APPROVED, <br />IN WRITING, BY THE TENANT REPRESENTATIVE PRIOR TO PURCHASE AND INSTALLATION. <br />GC TO REFER TO'THE SCOPE OF WORK' ON THE DRAWINGS <br />AND F.D.S.'S HANDOUTS <br />GC TO VERIFY/CONFIRM QUANTITY AND LOCATION OF ALL <br />FINISHES TO INCLUDE BASE <br />J-BOX MOUNTED BY E.C. <br />TO BOTTOM OF BAR <br />JOIST/PURLIN. <br />ELECTRICAL WHIP W/ <br />PIGTAIL CONNECTOR <br />PROVIDED BY E.C. SEE <br />SCHEDULE, THIS DRAWING. <br />2 CHANNEL POWER POLE SUPPLIED <br />AND INSTALLED BY FDS STORE <br />OPENING TEAM. FDS CABLING <br />CONTRACTOR SHALL RUN CAT-5 <br />CABLES DOWN DATA CHANNEL <br />OF POWER POLE. <br />CHECKOUT <br />COUNTER <br />ELECTRICAL WHIP W/ PIG TAIL <br />CONNECTOR FACTORY INSTALLED <br />AS PART OF POWER POLE <br />ASSEMBLY. FDS OPENING TEAM <br />SHALL MAKE FINAL CONNECTION <br />OF PIGTAIL CONNECTORS. <br />ALL THREAD ROD <br />UNI-STRUT AS REQUIRED <br />ATTACHED TO STRUCTURE. <br />"U" BOLT <br />ATTACH POWER POLE BOTTOM <br />BRACKET TO COUNTER (OR <br />FLOOR). <br />POVNER POLE I NSTALLAT I ON SETA I L <br />SCALE : NTS <br />ROOF STRUCTURE BY METAL BUILDING <br />MANUFACTURER <br />(4) ALL TREAD RODS ATTACHED TO (2) <br />PARALLEL UNISTRUT SUPPORTS (NOT <br />SHOWN) BOLTED TO STRUCTURE <br />ABOVE. BY G.C. <br />2 X 2 X A" TUBE STEEL THROUGH BOLTED <br />AT MIN. TWO ROOF PURLINS <br />DOOR SCHEDULE: <br />DOORS <br />z <br />FRAMES <br />m <br />o Q w <br />m <br />=W <br />oD <br />z <br />m <br />m Q w <br />I- m <br />' W <br />❑D <br />z <br />o m <br />= Q w <br />m m <br />W W� <br />Ir0D <br />m z <br />HD.WARE <br />REMARKS <br />DOOR <br />NO. <br />SIZE <br />nw <br />¢ <br />W <br />= <br />cn <br />z <br />Q <br />-J <br />w <br />m <br />: <br />OVERALL SIZE <br />a <br />z <br />Q <br />w <br />WIDTH <br />HEIGHT <br />TH. <br />WIDTH <br />HEIGHT <br />DEPTH <br />- <br />- <br />, <br />2 <br />3'-0" <br />7'-0" <br />1 3/8" <br />1 <br />WD <br />PAIN <br />" <br />Y-4" <br />7'-2" <br />1 <br />PAINT <br />HC MTL <br />7 <br />DOOR UNDERCUT 1" (TYP), CLOSURE DEVICE <br />3 <br />(2) X-0" <br />7'-0" <br />3 <br />MTL <br />PAIN <br />" <br />6'-4" <br />7'-2" <br />2 <br />PAINT <br />HC MTL <br />3 <br />ELIASON DOOR MODEL #LWP3-PR72X84FD <br />4 <br />X-0 <br />7'-0" <br />1 3/8" <br />MTL <br />PAIN <br />3-3 <br />'-4" <br />7'-2" <br />PAINT <br />HC MTL <br />5 <br />180 DEGREE PEEPSITE AT 5'-0 AFF <br />DOOR NOTES: <br />1. DOORS TO COMPLY W/ NCSBC ACCESSIBILITY CODE. <br />2. ALL WOOD (WD) DOORS TO BE SOLID CORE, BIRCH VENEER. <br />3. IC MET = INSULATED CORE, METAL DOOR. <br />4. FIRE RATED DOORS SHALL HAVE RATED FRAMES AND HARDWARE <br />TO MATCH. ALL SHALL CARRY REQUIRED UL RATING LABEL. <br />5. VERIFY ALL DOOR FINISHES WITH OWNER. <br />GRAPHIC LEGEND: <br />IMMOM NEW WALL (MATERIAL INDICATION MAY VARY) <br />EXISTING CONSTRUCTION <br />TO BE REMOVED <br />EXISTING WALL TO REMAIN <br />OPARTITION TYPE -SEE KEY <br />0 PLAN NOTE <br />NOTE: <br />SEE ELECTRICAL DRAWINGS BY SABER ENGINEERING FOR POWER AND <br />LIGHTING DETAILS. <br />LIGHT FIXTURE SCHEDULE <br />LTR <br />MANUFACTURER <br />LAMPS <br />MOUNTING <br />DESCRIPTION <br />A <br />BY OWNER <br />4-32W T8 <br />CHAIN <br />4-LAMP 8' <br />B <br />BY OWNER <br />2-32W T8 <br />CHAIN <br />2-LAMP 4' <br />C <br />BY OWNER <br />1-175W-MH <br />WALL <br />175W MH WALLPAK <br />EXEM <br />BY OWNER <br />INCLUDED <br />WALL <br />EXIT/EMERGENCY LIGHT <br />EX <br />BY OWNER <br />INCLUDED <br />WALL <br />EXIT LIGHT <br />EM <br />BY OWNER <br />INCLUDED <br />WALL <br />EMERGENCY LIGHT <br />RESTROOM NOTES: <br />1. LAYOUT OF RESTROOM FACILITIES SHALL COMPLY WITH ALL APPLICABLE <br />STATE AND LOCAL CODES, INCLUDING ALL ADA REQUIREMENTS. SUBMIT <br />ANY MODIFIED LAYOUTS TO FAMILY DOLLAR FOR THEIR REVIEW AND <br />APPROVAL. <br />2. TOILETS SHALL BE EQUIPPED W/ THE FOLLOWING ACCESSIBLE FOR EACH. <br />1 EA. 18" X 24" FRAMED WALL MIRROR CONCEALED MOUNTING OVER EACH <br />LAVATORY. INSTALL W/ BASE @ 40" AFF. <br />1 EA. TOILET TISSUE HOLDER - BRADLEY MODEL "5054" 18 GA CHROME PLATED <br />STEEL OR APPROVED EQUAL. INSTALL W/ CENTER LINE @ 24" AFF. <br />1 EA. HOOK - BRADLEY MODEL 931 MOUNTED TO DOOR FACE OR APPROVED <br />EQUAL. INSTALL HOOK @ 4'-6" AFF. <br />1 EA. 1-1/4" X 36" & 42" S.S. CODE APPROVED GRAB BARS WALL (OR FLOOR <br />MOUNTED) AS REQUIRED. INSTALL GRAB BARS @ 34" - 36" AFF. <br />1 EA. ELEC. HAND DRYER - INSTALL WITH OPERATING MECHANISM @ 48" AFF. <br />BY ELECTRIC AIRE MODEL LE-1. DRYER LOCATED ON SIDE WALL TO LAV. <br />1 EA. CODE APPROVED ROOM IDENTIFICATION SIGN INSTALLED ADJACENT TO <br />STRIKE JAMB/LATCH SIDE OF DOOR W/ HORIZONTAL CENTERLINE @ 60" AFF. <br />2 EA. TOILET SHELF - 24" L X 8" D - WHITE - INSTALL W/ SHELF @ 46" AFF. <br />USE PREFINISHED WHITE ADJUSTABLE SHELF STANDARDS AND SUPPORTS. <br />3. INSTALL CONTINUOUS FIRE RETARDANT TREATED 2 X 6 BLOCKING BETWEEN STUDS FOR <br />ALL HANDRAILS, GRAB BARS, FIXTURES, BRACKETS, ACCESSORIES, CABINETRY, AND MISC. <br />SPECIAL TIES AS REQURIED, UNLESS NOTED OTHERWISE. <br />4. USE 1/2" MOISTURE RESISTANT GWB (GREENBOARD) FOR RESTROOM WALLS AND TYP <br />FOR GWB CEILINGS. <br />5. DOOR HARDWARE MUST BE MOUNTED BETWEEN 34" (MIN.) AND 48" (MAX.) <br />NOTE: <br />MONITOR NOT INSTALLED IN <br />ALL STORE LOCATIONS. LL OR G.C. <br />TO VERIFY WITH FAMILY DOLLAR <br />PROJECT MANAGER IF MONITOR WILL <br />BE REQUIRED PER LOCAL CRIME <br />FACTORS. MONITOR TO BE INSTALLED <br />BY OTHERS. <br />STEEL PLATES PROVIDED BY BRACKET <br />MANUFACTURER. THROUGH BOLTED TO EA. SIDE OF <br />TUBE STEEL AS SHOWN. USE LOCK WASHERS TOP AND <br />BOTTOM, RETAINING COLLAR TOP AND BOTTOM - <br />LOCATE 18' +/- BACK FROM FRONT OF STORE ON <br />CENTERLINE OF ENTRY DOORS. SEE FIXTURE PLAN <br />FOR EXACT LOCATION. <br />SAFETY CABLE ATTACHED TO ROOF STRUCTURE <br />ABOVE. VERIFY W/ MFR. APPROPRIATE CABLE <br />STRENGTH FOR MONITOR ASSEMBLY WEIGHT. BY G.C. <br />LCD CEILING MOUNT MONITOR BRACKET BY CLINTON <br />ELECTRONICS - MODEL #CE-CM-8-6 FOR MAX 5'-6" <br />EXTENSION AND CE-CM-L-12 FOR MAX 1 V-6" <br />EXTENSION. VERIFY FINAL FIXTURE PLAN PRIOR TO <br />ORDERING. CALL 800-873-2580 EXT. 1404 FOR INFO - <br />BOTTOM OF MONITOR TO BE 8'-6" A.F.F. MONITOR <br />SUPPLIED BY FDS. INSTALL SAFETY CABLE AS <br />INSTRUCTED BY MANUFACTURER. <br />MONITOR HANGING nr:TA I L <br />SCALE: NTS <br />3/4" FIRE TREATED PLYWOOD <br />1/2" MR GWB <br />3-5/8 MTL. STUD <br />CONT. 22 MSG GALV. <br />STEEL TOP TRACK <br />FRP TO 4'-0 AFF <br />FRP TO 4'-0 AFF <br />1/2" MR GWB EA. SIDE <br />20 MSG. 3-5/8 MTL. STUD @ 16" O.C. <br />CONT. 22 MSG GALV. STEEL BASE <br />TRACK FASTENED TO SLAB W/ <br />STEEL FASTENERS 24" O.C. MAX <br />SECTION <br />SCALE: 3/4" - 1'-0" <br />HARDWARE NOTES: <br />A. ALL EXIT DOORS (EXCEPT STOREFRONT) SHALL HAVE ARM -A -DOOR HDWARE <br />B. PROVIDE STOPS ON ALL DOORS, USE WALL STOPS WHERE AVAILABLE, <br />& FLOOR STOPS WHERE NECESSARY. <br />C. ALL HARDWARE SHALL MEET THE REQUIREMENTS OF THE ADA, ANSI 117.1, AND VOL. 1-C <br />D. CLOSERS SHALL BE COMMERCIAL GRADE. <br />E. VERIFY HARDWARE AND DOOR TYPES W/ F.D.S. PRIOR TO PLACING ORDER. <br />HARDWARE SCHEDULE: <br />CONTRACTOR TO INSPECT EXISTING DOORS & VERIFY W/ TENANT POSSIBLE REUSE BEFORE ORDERING HARDWARE <br />HARDWARE GROUP <br />DESCRIPTION <br />FINISH <br />MANUFACTURER <br />HARDWARE # 1 (-) <br />DOORS (-) STOREFRONT <br />(1) LOCKSET EACH <br />EXT KEY LOCK W/ INTERIOR THUMB TURN <br />PER TENANT <br />PER TENANT <br />(3) HINGES EACH <br />CONTINUOUS HINGES IN LIEU OF PIVOTS <br />PER TENANT <br />PER TENANT <br />(1) THRESHOLD EACH <br />BRUSH STYLE DOOR SWEEP C380CLA06BL <br />" " <br />SEALEZE (OR EQUAL) <br />(1) CLOSURE EACH <br />KAWNEER "HUSKY 11" W/ 105 DEGREE HOLD OPEN <br />PER TENANT <br />KAWNEER (OR EQUAL) <br />HARDWARE # 2 (-) <br />DOORS (-) EXT/FRIEGHT RECEIVING <br />NO EXTERIOR KNOBS OR HANDLES <br />(1) LOCKSET EACH <br />"ARM -A -DOOR" A101-030 <br />ARM -A -DOOR (OR EQUAL) <br />CONTACT: 407-291-1443 FOR INFO <br />(3) HINGES EACH <br />11291 1/2" PR (4 1/2" X 41/2" USP) <br />US26D <br />HAGER (OR EQUAL) <br />(1) FLOOR STOP EACH <br />" " <br />" " (OR EQUAL) <br />(1) CLOSER EACH <br />YALE 4020 <br />PER TENANT <br />YALE (OR EQUAL) <br />(1) WEATHERSTRIP EACH <br />303ASW/S3 <br />" " <br />PEMKO (OR EQUAL) <br />(1) THRESHOLD EACH <br />BRUSH STYLE DOOR SWEEP C380SLA06BL <br />" " <br />SEALEZE (OR EQUAL) <br />(1) DOOR VIEWER EACH <br />180 DEGREE @ 5' AFF <br />PER TENANT <br />PER TENANT (OR EQUAL) <br />(1) KICK PLATE EACH <br />PER TENANT <br />PER TENANT <br />PER TENANT (OR EQUAL) <br />HARDWARE # 3 (1) <br />DOORS (D) SALES SUPPORT <br />"ELIASON" (OR EQUAL) <br />DBL SWING IMPACT RESISTANT DOORS <br />HARDWARE PER MANUFACTURER <br />MODEL LWP-3 FOR INFOR & PRICE <br />CONTACT MANUR AT 800-828-3655 <br />HARDWARE # 4 (1) <br />DOORS (A) STOCKISALES <br />(1) LOCKSET EACH <br />A105-LEV-626 (KEYED DEADBOLT W/ THUMB TURN) <br />SCHLAGE A10S-LEV-626 <br />PER TENANT <br />SCHLAGE (OR EQUAL) <br />(3) HINGES EACH <br />1129 1 1/2" PR (4 1/2" X 41/2" USP) <br />US26D <br />HAGER (OR EQUAL) <br />(1) CLOSER EACH <br />YALE 4020 <br />PAINT TO MATCH FRAME <br />YALE (OR EQUAL) <br />(2) KICK PLATE EACH <br />BOTH SIDES <br />PAINT TO MATCH FRAME <br />HAGER (OR EQUAL) <br />(1) FLOOR STOP <br />243F 26D <br />HAGER (OR EQUAL) <br />HARDWARE # 5 (1) <br />DOOR (B) OFFICE <br />(1) LOCKSET EACH <br />A10S-LEV-626 <br />PER TENANT <br />HAGER (OR EQUAL) <br />(1) CLOSER EACH <br />YALE 4020 <br />US26D <br />YALE (OR EQUAL) <br />(1) KICK PLATE EACH <br />EACH SIDE <br />PAINT TO MATCH FRAME <br />HAGER (OR EQUAL) <br />(1) DOOR VIEWER <br />DS-1000 <br />PER TENANT <br />PER TENANT (OR EQUAL) <br />(3) HINGES EACH <br />11291 1/2" PR (4 1/2" X 41/2" USP) <br />US26D <br />HAGER (OR EQUAL) <br />HARDWARE # 6 (1) <br />DOOR (B) OFFICE <br />(1) LOCKSET EACH <br />CLASSRM. SET FINISH TO MATCH OTHER HD.WARE <br />PER TENANT <br />HAGER (OR EQUAL) <br />(3) HINGES EACH <br />1129 1 1/2" PR (4 1/2" X 41/2" USP) <br />US26D <br />HAGER (OR EQUAL) <br />HARDWARE # 7 (2) <br />DOOR (C) RESTROOM <br />(1) LOCKSET EACH <br />SCHLAGE A40S-LEV-626 <br />" " <br />HAGER (OR EQUAL) <br />(3) HINGES EACH <br />1129 1 1/2" PR (4 1/2" X 41/2" USP) <br />US26D <br />HAGER (OR EQUAL) <br />(1) FLOOR STOP EACH <br />243F 26D <br />' " <br />HAGER (OR EQUAL) <br />(1) CLOSER EACH <br />YALE 4020 <br />PAINT TO MATCH FRAME <br />YALE (OR EQUAL) <br />HARDWARE # 8 (-) <br />DOOR (-) SALES AREA EM. EXIT <br />(1) LOCKSET EACH <br />"ARM -A -DOOR" A101-030 <br />�� <br />ARM -A -DOOR �OR EQUAL) <br />CONTACT: 407-291-1443 OR INFO <br />(3) HINGES EACH <br />1129 1 1/2" PR (4 1/2" X 41/2" USP) <br />US26D <br />HAGER (OR EQUAL) <br />(1) THRESHOLD EACH <br />BRUSH STYLE DOOR SWEEP C380CLA06BL <br />" " <br />SEALEZE (OR EQUAL) <br />(1) CLOSER EACH <br />YALE 4020 <br />PAINT TO MATCH FRAME <br />YALE (OR EQUAL) <br />HARDWARE NOTES: <br />1. VERIFY EXISTING HARDWARE W/ TENANT REP. & SUPPLEMENT WITH NEW HARDWARE AS SPECIFIED. VERIFY HARDWARE REQUIREMENTS WITH TENANT. <br />2. ALL SELECTED HARDWARE AND THRESHOLDS TO COMPLY WITH ALL NATIONAL, STATE AND LOCAL ADA CODES AND REQUIREMENTS. <br />VERIFY ACCESSIBILITY COMPLIANCE WITH MANUFACTURER. <br />3. G.C. TO INSPECT EXISTING EXIT DOORS FOR PANIC/ALARM HARDWARE. INSTALL NEW ALARM DEVICE (ARM -A -DOOR MODEL NO. A101-030), <br />PANIC ALARM W/ LOCK AS NECESSARY. <br />4. EXISTING RECEIVING/EXIT DOOR TO HAVE A DOOR TO HAVE A DOOR VIEWER BY DOORSCOPE INSTALLED AS WELL AS PANIC HARDWARE (VERIFY W/ LANDLORD). <br />5. REUSE ANY EXISTING DOORS THAT MEET W/ THE TENANT REPRESENTATIVE'S APPROVAL. <br />6. ALL EXTERIOR DOORS SHOULD BE BETWEEN 10 TO 15 LBS. OF FORCE. <br />7. ALL INTERIOR DOORS SHOULD BEAT 5 LBS. OF FORCE. <br />o <br />ocj o <br />(� NN0 pp <br />U) N S U <br />J n Gc <br />W oti-6 <br />(Dcv�a3 <br />=Ucf) <br />ca <br />� Q'S � <br />( j co <br />^V Lvrn o <br />cu <br />O .0ci <br />Uco 0 <br />C:) <br />ISSUED FOR REVIEW <br />DATE: <br />ISSUED FOR PERMIT <br />DATE: <br />IISSUED FOR CONSTRUCTION' <br />DATE: <br />w <br />Q <br />0 <br />z <br />O <br />a <br />U <br />U) <br />w <br />0 <br />w <br />Vt' ,, �" w <br />0 <br />. Z J_ <br />e <br />Y <br />Z <br />�� <br />lwm <br />_V <br />® _j <br />ci <br />Q <br />U) <br />J <br />Q <br />W <br />04 Q <br />0 Lo 'n <br />LL cMM U ) <br />ou W <br />LJL J J <br />00 J <br />D Q= <br />3: o_ <br />o CN <br />Z � N U) <br />DATE: 1.6.11 <br />DRAWN BY: PDL <br />CHECKED BY: PDL <br />SHEET <br />A�3 <br />ice- r ri 77 <br />