IN <br />GENERAL NOTES: <br />THIS BUILDING HAS BEEN DESIGNED TO CONFORM TO THE 2011 FLORIDA BUILDING CODE <br />6TH EDITION AND THE 2011 FLORIDA BUILDING CODE - RESIDENTIAL 6TH EDITION, <br />T.L. HANSON A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL ENGINEERING <br />COMPANY: HAS APPLIED "RATIONAL ANALYSIS" FOR THE STRUCTURAL DESIGN OF THIS STRUCTURE. <br />THE BUILDING (INCLUDING ALL COMPONENTS AND CLADDINGS) SHALL BE DESIGNED FOR THE <br />FOLLOWING SUPERIMPOSED LOADS: <br />SLAB: <br />LIVE LOAD - 50 P.S.F. <br />DEAD LOAD - 10 P.S.F. <br />ROOF: <br />LIVE LOAD (TRUSS TOP CHORD) - 20 <br />DEAD LOAD (TRUSS TOP CHORD) - 10 P.S.F. (15 P.S.F. WHEN TILE ROOFING IS INSTALLED) <br />DEAD LOAD (TRUSS BOTTOM CHORD) - 10 P.S.F. <br />ASSUMED TRUSS SELF WEIGHT (DEAD LOAD) - 1 P.S.F. <br />WIND: <br />BUILDING IS DESIGNED TO CONFORM TO ASCE 1-10, CHAPTERS 26 THRU 31: PER 2011 FLORIDA <br />BUILDING CODE, RESIDENTIAL 6TH EDITION- SECTION R301.2.1.1. AND 2011 FLORIDA BUILDING CODE <br />6TH EDITION SECTION 1609 <br />COMPONENT 4 CLADDING WIND LOADS <br />WIND DESIGN ASSUMPTIONS: <br />BUILDING EXPOSURE - B <br />BUILDING RISK CATEGORY - II <br />MEAN ROOF HEIGHT 30' OR LESS <br />HEIGHT 4 EXPOSURE ADJUSTMENT <br />COEFFICIENT - 1.0 <br />ENCLOSED BUILDING <br />INTERNAL PRESSURE COEFFICIENT - +/- 0.18 <br />WIND SPEED SHOWN AT THE BOTTOM RIGHT <br />CORNER OF THIS SHEET <br />ALL STRUCTURAL ELEMENTS, EXTERIOR <br />WALLS AND INTERIOR WALLS SHALL BE <br />TYPE V CONSTRUCTION PER FBC 602.5 <br />ALL OTHERCOMPONENT <br />BUILDING <br />ROOF OVERHANG <br />ZONE <br />LOADS <br />LOADS <br />1 <br />N/A <br />+32.3/-353 <br />2 <br />-65.1 <br />+32.3/-56.2 <br />3 <br />-110.6 <br />4 <br />N/A <br />+35.3/-38,2 <br />5 <br />N/A <br />+35.3/-41.2 <br />SOIL BEARING 4 COMPACTION: <br />THESE PLANS WERE DRAWN BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF 2,000 P.S.F. <br />(MINIMUM), THE CONTRACTOR/PROPERTY OWNER ARE RESPONSIBLE FOR VERIFYING THAT THE SOIL <br />ON THE SITE IS PROPERLY PREPARED 4 COMPACTED SUCH THAT IT CAN SUPPORT A 2,000 P,S,F, <br />FOUNDATION LOADING. <br />T.L. HANSON: A REGISTERED, LICENSED, FLORIDA PROFESSIONAL STRUCTURAL <br />ENGINEERING COMPANY: DESIGNED THESE FOUNDATIONS WITHOUT VISITING THE CONSTRUCTION SITE <br />NOR PERFORMING ANY SOIL TESTING. <br />T,L, HANSON SHALL NOT BE RESPONIS15LE FOR THE SITE SOILS ABILITY TO SUPPORT <br />THE BUILDING LOADS, <br />FOUNDATIONS 4 SLAB -ON -GRADE: <br />BUILDING SITE SHALL BE SCRAPED TO REMOVE ALL ORGANIC MATERIALS WITHIN THE BUILDING AREA, <br />ANY ADDITIONAL FILL PLACED ON THE BUILDING PAD AREA, SHALL BE COMPACTED <br />SUCH THAT IT CAN ADEQUATELY SUPPORT A 2,000 P.S.F. FOUNDATION LOADING. <br />SLAB SHALL BE PLACED OVER A 6 MIL VAPOR BARRIER ON CLEAN, ADEQUATELY <br />COMPACTED AND TERMITE POISONED SOIL, <br />CONCRETE UTILIZED IN THE FOUNDATIONS AND SLABS SHALL HAVE A MINIMUM 26 DAY <br />COMPRESSIVE STRENGTH OF 2,500 P.S.I. <br />REINFORCING STEEL SHALL BE GRADE 40 MINIMUM AND IDENTIFIED IN ACCORDANCE <br />WITH ASTM A-615. LAP SPLICES, WHERE REQUIRED, SHALL BE A MINIMUM OF 25" <br />FOR 05 REBAR, 30" FOR "6 REBAR 4 35" FOR 01 REBAR, <br />PLANS ARE ENGINEERED FOR A MAXIMUM STEMWALL HEIGHT OF 4 COURSES (AFTER <br />FINAL SITE GRADING). THE CONTRACTOR OR BUILDING OWNER SHALL DETERMINE THE <br />EXACT STEMWALL HEIGHT BASED UPON SITE CONDITIONS PRIOR TO POURING THE FOUNDATION <br />AND CONTACT ARKAY ENGINEERING WHEN MORE THAN 4 COURSES ARE REQUIRED. <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE <br />SITE FOR THE BUILDING INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE EXPOSED AND <br />A STRING STRETCHED FROM MARKER TO MARKER TO VERIFY THE REQUIRED BUILDING SETBACKS, <br />TIMBER MATERIALS: <br />ALL TIMBER MATERIALS SHALL BE AS FOLLOWS: <br />ALL PLUMBING, ELECTRICAL AND MECHANICAL ROUGH -INS MUST BE COMPLETE, INSPECTED AND APPROVED <br />PRIOR TO REQUESTING THE FRAMING INSPECTION. <br />IF DESIRED, EQUIVALENT CONNECTORS MADE BY ANOTHER SUPPLIER MAY BE USED IN PLACE OF THE <br />"USP" OR "SIMPSON" CONNECTORS SHOWN. <br />ALL LUMBER IN CONTACT WITH MASONRY WILL BE PRESSURE TREATED <br />MATERIALS <br />INTERIOR STUD WALLS TO BE OF 2 X 4 02 SPRUCE OR SETTER WITH SINGLE 2 X 4 P.T. <br />PINE BOTTOM PLATE AND SINGLE 2 X 4 02 SPRUCE TOP PLATE WITH STUDS SPACED <br />MAXIMUM 24" OC. WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE, WITH WALLS AT <br />GARAGE TO HAVE MINIMUM R-11 INSULATION <br />ATTIC ACCESS: <br />ATTIC ACCESS SHALL BE PROVIDED TO ATTIC AREAS EXCEEDING 30 SQ, FT, AND HAVING MINIMUM <br />30 INCHES OF VERTICAL HEIGHT, ROUGH -FRAMED OPENING NOT TO BE LESS THAN 22 X 30 INCHES, <br />WHEN MECHANICAL EQUIPMENT IS LOCATED IN THE ATTIC, IT SHALL BE INSTALLED IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION M1305.1.3 <br />SOIL TERMITE TREATMENT: <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING PESTICIDES <br />APPLIED TO SOIL, OR WOOD, BAITING SYSTEMS, OR OTHER APPROVED PROTECTION LABELED FOR <br />USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. <br />2x4 CROSS -BRACING 6 RIDGE <br />20'-0" MAX I 7 <br />lip <br />I <br />pm <br />00 <br />ON <br />11 <br />mmo <br />1 <br />a <br />0 <br />10 <br />INN <br />MUNI <br />SEE TRUSS SYSTEM ENGINEERING DRAWINGS FOR ANY ADDITIONAL <br />BRACING OR CROSS BRACING REQUIREMENTS <br />REQ. MINIMUM I TRUSS 5RACING <br />THE CLIENT UNDERSTANDS THAT THE DESIGNER CARRIES NO LIABILITY INSURANCE AND THEREFORE <br />AGREES TO HOLD HARMLESS, IDEMNIFY, AND DEFEND DESIGNER FROM ALL CLAIMS, LOSSES AND <br />EXPENSES (INCLUDING REASONABLE ATTORNEY FEES) ARISING OUT OF OR RESULTING FROM THE <br />PROJECT. THE DESIGNER WILL IN GOOD FAITH ATTEMPT TO PROVIDE ERROR FREE CONSTRUCTION <br />DRAWINGS, BUT IN THE EVENT ERRORS OCCUR THE DESIGNER WILL NOT BE LIABLE FOR COST OF <br />REPAIRS OR DELAY TO THE CONSTRUCTION <br />TOP/BOTTOM CHORD GABLE <br />% END BRACING v 48" O.C. MAX <br />FOR THE FIRST 4 ROWS OF <br />TRUSSES (MIN 2X4 ) <br />lU <br />J <br />4 <br />CONT. BOTTOM CHORD <br />BRACING 0'x4" MIN.) o <br />10'-O" MAX. <br />A "CERTIFICATE OF COMPLIANCE" SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY A LICENSED <br />PEST CONTROL COMPANY BEFORE A "CERTIFICATE OF OCCUPANCY" WILL BE ISSUED, THE CERTIFICATE <br />SHALL STATE <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE FLORIDA <br />DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES," <br />IF A REGISTERED TERMITICIDE BAIT SYSTEM IS TO BE USED FOR SUBTERRANEAN TERMITE PREVENTION, <br />DO NOT APPLY. A SIGNED FIVE YEAR CONTRACT FROM THE ISSUE <br />OF THE CERTIFICATE OF OCCUPANCY ASSURING INSTALLATION, MAINTENANCE AND MONITORING OF THE <br />BAITING SYSTEM SHALL BE PROVIDED TO THE BUILDING OFFICIAL PRIOR TO THE SLAB POUR. THE SYSTEM <br />MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. <br />INITIAL SOIL POISONING TREATMENT SHALL BE DONE AFTER ALL EXCAVATION, <br />BACKFILLING 4 COMPACTION ARE COMPLETE <br />ANY SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RE -TREATED <br />(INCLUDING ANY BOXED OR FORMED AREAS) - <br />BOXED AREAS IN THE CONCRETE SLAB FOR INSTALLATION OF TRAPS SHALL BE MADE <br />WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF AN <br />ADEQUATE SIZE 4 DEPTH TO ELIMINATE ANY DISTURBANCE OF THE SOIL AFTER THE <br />INITIAL TREATMENT. <br />A MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR BARRIER PLACEMENT, RE -TREATMENT <br />SHALL BE REQUIRED <br />ANY CONCRETE OVERPOUR, MORTAR OR STUCCO MATERIALS ALONG THE FOUNDATION PERIMETER <br />MUST BE REMOVED PRIOR TO EXTERIOR SOIL TREATMENT <br />EXTERIOR SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 12 INCHES OF THE STRUCTURE SIDE WALLS <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER CONSTRUCTION IS <br />COMPLETE (INCLUDING LANDSCAPING AND IRRIGATION), ANY SOILS DISTURBED AFTER THE <br />VERTICAL BARRIER IS APPLIED, SHALL BE RE -TREATED. <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 12 INCHES AWAY FROM THE <br />BUILDING SIDEWALLS (PER FBC R318). <br />AFTER ALL WORK IS COMPLETED, ANY LOOSE WOOD AND FILL MUST BE REMOVED FROM BELOW <br />AND WITHIN 12 INCHES OF THE BUILDING. THIS SHALL INCLUDE ALL GRADE STAKES, TUB TRAP BOXES <br />FORMS, SHORING AND ANY OTHER CELLULOSE CONTAINING MATERIALS. <br />THE DISTANCE FROM THE EXTERIOR WALL COVERING (EXCEPTIONS: PAINT AND DECORATIVE <br />CEMENTITIOUS FINISHES LESS THAN 5/8 INCH THICK ADHERED DIRECTLY ONTO THE FOUNDATION <br />WALL) AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES TO ALLOW FOR INSPECTION <br />FOR FUTURE TERMITE INFESTATIONS <br />TRUSSES: <br />IF THE CONTRACTOR, TRUSS MANUFACTURER OR ANY OTHER DESIGN PROFESSIONALS REVISE THE <br />TRUSS SYSTEM LAYOUT FROM THOSE SHOWN ON THESE PLANS T. L. HANSON 4 ASSOCIATES IS <br />REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT, <br />EXTERIOR WINDOWS 4 DOOR ASSEMBLIES: <br />ALL EXTERIOR WINDOW 4 GLASS DOORS SHALL BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA <br />101/162 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, <br />PERFORMANCE CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY. <br />ALL MULLIONS AND ADJACENT DOOR/WINDOW ASSEMBLIES SHALL BE TESTED OR ENGINEERED TO <br />TRANSFER 1.5 TIMES THE DESIGN LOADS TO THE ROUGH OPENING SUBSTRATE. <br />INSTALL ALL WINDOW 4 DOOR ASSEMBLIES PER THE MANUFACTURERS ANCHORING RECOMMENDATIONS <br />TO ACHEIVE THE DESIGN PRESSURES SPECIFIED, <br />ELECTRICAL, PLUMBING 4 MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 411.003(2)(1) OF THE FLORIDA ADMINISTRATIVE CODE: ELECTRICAL, <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTORS TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN (WITHIN 6 FEET OF SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND -FAULT INTERRUPTER "GFI" CIRCUIT. <br />ALL ELECTRICAL OUTLETS IN BEDROOMS SHALL BE WIRED INTO AN ARC -FAULT INTERRUPTER <br />"Am" CIRCUIT. <br />SAFETY GLAZING: <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSES OF <br />GLAZING PER THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R308: <br />(1) GLAZING IN SWINGING DOORS, FIXED AND SLIDING PANELS OF SLIDING DOOR <br />ASSEMBLIES. <br />(2) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br />ROOMS, BATHTUBS, AND SHOWERS. GLAZING IN ANY PORTION OF A BUILDING WALL <br />ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS <br />THAN 60 INCHES ABOVE THE DRAIN INLET. <br />(3) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT A DOOR WHERE <br />THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH RADIUS OF THE DOOR IN A <br />CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE <br />FINISHED FLOOR OR WALKING SURFACE. <br />(4) GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS <br />DESCRIBED IN ITEMS (2) AND (3) ABOVE. THAT MEETS ALL OF THE FOLLOWING <br />CONDITIONS: <br />A) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQ. FT, <br />B) BOTTOM EDGE LESS THAN IS INCHES ABOVE THE FLOOR. <br />C) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />D) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE <br />PLANE OF THE GLAZING. <br />REFER TO THE FLORIDA BUILDING CODE, RESIDENTIAL - SECTION R3O8 FOR ADDITIONAL AREAS <br />THAT MAY BE CONSIDERED .4 HAZARDOUS LOCATION FOR THE PURPOSE OF GLAZING. <br />5'-O" <br />ROOF EDGE <br />4� <br />1„ <br />4� <br />E <br />O 9) <br />O <br />0 <br />O <br />2" X 8" RIDGE BOARD <br />CONT, 2"X4'L-� <br />USP "RT3" OR - <br />SIMPSON "H3" <br />HURR. STRAP m <br />48" O.C. TYP, <br />2"X4" HAILERS <br />(TYP.) <br />2"X4" VERTICAL SCAB im 46" O.C. <br />(MAX.) CONN. W/ 4-16D NAILS m <br />TOP 4 USP "RT3" OR SIMPSON "H3" <br />HURRICANE CLIP AT BOTTOM, <br />2" X 6" (02 YELLOW PINE) <br />RAFTERS m 24" O.C, <br />USP "RT3" OR <br />SIMPSON 11H3" <br />PURR. STRAP <br />EACH END <br />2" X 8" RIDGE BOARD <br />SIMPSON H3 FRAMING <br />ANCHOR TYP. <br />ROOF SHEATHING <br />VERT. SCAB <br />BEVEL CUT <br />TYP, <br />CONT, 2"X4" <br />NAILER TYP. <br />(2-16D NAILS <br />PER TRUSS) <br />USP "RT3" OR <br />SIMPSON "143" <br />PURR, STRAP m SECTION IIA11-IIAII <br />48" O.G. TYP. <br />BUSSES BELOW SHEATHED <br />RIOR TO VALLEY FRAMING <br />ISTALLATION. <br />X ro" ("2 YELLOW PINE) <br />VALLEY FRAMING (TYP.) <br />COMMON TRUSS <br />END NOT EXPOSED TO WIND <br />ROOF VALLEY DETAIL - <br />NOT -TO -SCALE <br />0 <br />PROVIDE MINIMUM 16" 26 GA VALLEY FLASHING o <br />AT ALL ROOF CHANGES AND SIDE WALL AREAS ° <br />0 <br />PER FBC 1012,5 /R103,15, 103,8., 903.2 AND SO5 <br />PLACE ROOF CEMENT COATING AT ROOF DECKS 0 0 <br />EDGES OF FLASHING AND ALL LAPS. NAIL FLASHING ° ° <br />WITH 1 1/2" ROOF NAILS 12" OC 0 0 <br />0 ° <br />o ° <br />0 ° <br />° ° ° <br />0 ° <br />0 <br />0 <br />0 <br />° SIDE WALLS OR CHIMNE` <br />0 0 0 <br />0 <br />° o MINIMUM 8"X8" 26 GA ANGLE FL <br />0 OR STEP FLASHING, SEE NOTE < <br />0 ROOF DECK AT SIDE WALLS <br />TYPICAL ROOF FLASHING DETAIL <br />NOT TO SCALE <br />STUD SPACING <br />L- BRACING <br />NO <br />L-BRACING <br />(1) 2 X 4 <br />L BRACING <br />(2) 2 X 4 <br />L BRACING <br />(2) 2 X 6 <br />L BRACING <br />16" <br />0'-0" TO 4'5" <br />4'-5" TO 8'0" <br />8'011- 12-0" <br />12'0" TO 16'O" <br />24" <br />0'-0" TO 4'0" <br />4'0" TO TO" <br />1'0" TO 10'0" <br />10'0" TO 14'0" <br />p NO ANGLE BRACING REQUIRED WHEN <br />GABLE IS NO MORE THAN 24" TALL IN <br />CENTER <br />4 <br />l7 <br />BACKNAIL W/ (2) I&D NAILS <br />4 <br />GABLE END <br />5 -o PARTIAL ROOF PLAN 5 -0 <br />ZONE O 8d RING SHANK NAILS AT 6" O.C. AT EDGES <br />8d RING SHANK NAILS AT 6" O.C. INTERMEDIATE <br />ZONES 2O 3O ad RING SHANK NAILS AT 6" O.C., 4" O.C. AT <br />ROOF EDGES, RIDGE LINE, OR GABLE ENDWALL <br />NOTE: END JOINTS FOR SHEATHING SHALL BE STAGGERED <br />AND OCCUR OVER A FRAMING MEMBER. <br />ROOF SHEATHING NAILINC-s <br />NOT TO SCALE <br />O <br />O <br />NOTE: NO L BRACING REQUIRED WHEN <br />PEAK OF GABLE IS 4'0" OR LESS <br />BRACING TO EXTEND AT LEAST 90 <br />45 DEGREES OF WEB LENGTH ( SEE TABLE ABOVE) <br />MAXIMUM <br />STEP DOWN GABLE TRUSS WITH ONE LAYER <br />I/2" CDX SHEATHING OR 1/I6" OSB NAILED <br />WITH 8D COMMON NAILS 4" OC <br />SIMPSON LSTA24 OR EQUAL <br />AT 2'0" OC ( TYP) <br />2X4 ANGLE BRACING AT 48" OC ALONG <br />GABLE END NAIL ENDS TO 2 X 4 BLOCKING <br />WEB BLOCKING WITH (2) 160 TOE NAILS <br />WOOD BEAM OR <br />WALL BELOW <br />1/2" EXTERIOR <br />CEILING BOARD 2 J( 4 NAILER ATTACHED TO BOTTOM <br />CORD OF GABLE TRUSS AND COMMON <br />TRUSS WITH 2 EACH 120 COMMON NAILS <br />AT EACH UPRIGHT MEMBER ON GABLE <br />GABLE END BRACING DETAIL <br />NOT TO SCALE <br />2 X 4 WEB BLOCKS NAILED IN BETWEEN <br />WEBS WITH (2) 16D NAILS EACH END WITH <br />(6) 16D NAILS AT EACH END NAIL TO 2X1 <br />4-16D TOE NAILS tv <br />RIDGE BOARD END <br />USE lU SIMPSON HIO CLIP AT A <br />TRUSSES TO WOOD WALLS, FILL <br />NAIL HOLES WITH IODXI 1/2" NAI <br />1NG 8b" BLOCK WALL <br />ROOF TRU88 PLAN 1/4II _ 11 OII <br />HVAC PLAN 1/4 = 11 OII <br />—T.L. VAN -SON FEE, LICENrE NO 38654 <br />1110 <br />PVO S fAi ADE CI F r33526 <br />I HERBY CE1�11 �,1%42-� ESE 'LA,t*C C" NDT SPECIFICATIONS <br />WERE PREPAI"I"-t j i0 DIa%,�T,,DIRECT SUPERVISION <br />ARE IN COMPLIA E tUlT�l"CF�A�T.FlI� SECTION 1609 OF THE <br />FLORIDA BUILDIN g�,2IiT LtiDDITION AND ASCE 1-10 <br />FOR 139 MPH WIND Z� 14 A#7EGORY II AND THE ENTIRE <br />2011 BUILDING CODE RESIDENTIAL 6TH ADDITION <br />W <br />.Q <br />Q <br />z <br />10 <br />N <br />W <br />U <br />cM <br />N <br />LO <br />z <br />co <br />M <br />Of F- <br />O o <br />J N <br />tL ti <br />In <br />z <br />co <br />I? <br />— <br />N <br />U L0 <br />XX <br />0 Q Q <br />m <br />W — W <br />W <br />0 cn <br />cA r <br />r4 <br />Q <br />Z d N <br />FS } <br />m N U-) <br />00 m 0) LO <br />M <br />W <br />2 U_ <br />LL <br />IL <br />�O <br />00 <br />— <br />co <br />0 <br />m <br />11.1 <br />" N U�) <br />6 rm ro <br />z m m <br />N � m -0 (Lu <br />L <br />e <br />a <br />ww °LLz <br />Z� <br />Zo� z <br />�z aQ d <br />0 <br />Nz <br />z� <br />0 <br />n� <br />F' <br />O <br />Q1 <br />Q <br />Q <br />w <br />Q <br />0 <br />z <br />O <br />re <br />Owwnn <br />z <br />V/ <br />� <br />ul <br />�• 1 <br />u <br />z <br />O <br />Q� <br />� <br />fin: <br />!� <br />Q <br />� <br />---Qyyy <br />N <br />It <br />l <br />Ln <br />N <br />d) <br />m <br />LIVING AREA <br />124 SCQ, FT, <br />FIG <br />2OF2 <br />